{"id":12366,"date":"2022-01-20T00:01:55","date_gmt":"2022-01-20T06:01:55","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/materials\/?p=12366"},"modified":"2023-06-12T16:35:01","modified_gmt":"2023-06-12T21:35:01","slug":"cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/","title":{"rendered":"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM"},"content":{"rendered":"<h2><\/h2>\n<h2><a href=\"https:\/\/ter.li\/w1vn6t\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-13483\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/11\/Join-the-conversation-banner-in-blogs-social-graphic-1143250-779x134-2.png\" alt=\"\" width=\"779\" height=\"134\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/11\/Join-the-conversation-banner-in-blogs-social-graphic-1143250-779x134-2.png 779w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/11\/Join-the-conversation-banner-in-blogs-social-graphic-1143250-779x134-2-300x52.png 300w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2019\/11\/Join-the-conversation-banner-in-blogs-social-graphic-1143250-779x134-2-768x132.png 768w\" sizes=\"auto, (max-width: 779px) 100vw, 779px\" \/><\/a><\/h2>\n<h2 style=\"font-size: 100%\"><strong>Atomic-scale high-resolution TEM<\/strong><\/h2>\n<p>As scientists in industry and academia increasingly require sub-nanometer information to better understand new materials\u2019 properties, transmission electron microscopy (TEM) has developed to deliver spatial and chemical information at the nanoscale in a wide variety of fields such as catalysis, metals, batteries, and polymers as well as novel materials to accelerate development of next-gen technology. Researchers want high-resolution TEM to produce the highest quality images and most detailed information with the least amount of effort.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Cold field-emission electron gun<\/strong><\/h2>\n<p>Adding our new ultra-high brightness Cold Field Emission Gun (X-CFEG) to the Thermo Scientific Talos TEM enables fast high-resolution scanning transmission electron microscopy (STEM) imaging, Energy Dispersive X-Ray (EDXS), and Electron Energy Loss (EELS) analytics. Developed for use with our <a href=\"https:\/\/ter.li\/adt3wr\">Talos F200i<\/a> and <a href=\"https:\/\/ter.li\/n7t47x\">Talos F200X G2<\/a> TEM\/STEM platforms, the X-CFEG produces the high-resolution STEM images and analytical information needed to accurately analyze materials at sub-nanometer and atomic resolution.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Faster high-resolution TEM results with less effort<\/strong><\/h2>\n<p>With its unprecedented ultra-high brightness, small source size, and low energy spread, the X-CFEG improves the signal-to-noise ratio, providing the higher quality STEM images and EDS and EELS data needed to resolve previously imperceptible structures.<\/p>\n<p>Used together with the advanced optics and automation of the Talos TEM, it produces faster results with less effort than conventional field emission guns. Thanks to the X-CFEG\u2019s sharp tip, Talos users can capture STEM images at least 30 percent faster than with conventional field emission guns while achieving improved STEM resolutions as high as 0.136 nanometer with high probe currents.<\/p>\n<h2 style=\"font-size: 100%\"><strong>A wide range of materials research applications<\/strong><\/h2>\n<p>These faster, higher-quality results enable researchers with various levels of experience to advance many areas of materials science including battery development, catalysis and biomedical applications.<\/p>\n<p>As researchers work to develop safer, environmentally friendly batteries with better safety, for example, they need to analyze the chemistry and performance correlation of rechargeable battery materials at better signal-to-noise ratios with high energy resolution to resolve the chemical details with EELS.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-12369 aligncenter\" title=\"High-resolution TEM for the analysis of rechargeable battery materials\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/XCFEG-rechargeable-battery-materials.jpg\" alt=\"High-resolution TEM for the analysis of rechargeable battery materials\" width=\"421\" height=\"168\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/XCFEG-rechargeable-battery-materials.jpg 648w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/XCFEG-rechargeable-battery-materials-300x120.jpg 300w\" sizes=\"auto, (max-width: 421px) 100vw, 421px\" \/><\/p>\n<p style=\"text-align: center\"><em>Using an X-CFEG together with a Talos TEM, researchers can analyze the fine structures and chemistry of rechargeable battery materials at high energy resolutions as they study the design of environmentally friendly batteries. Sample courtesy: Dr. Chongmin Wang, at Pacific Northwest National Laboratory (PNNL).<\/em><\/p>\n<p>Using the X-CFEG together with the Talos TEM, scientists can explore the presence of battery materials such as manganese, lithium, and titanium at high energy resolutions. Examining the fine structures of these materials with such detail enables researchers to make batteries more environmentally friendly and improve their performance and safety.<\/p>\n<p style=\"text-align: center\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-12370\" title=\"Graph comparing FEG performance of a conventional and X-CFEG\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph.png\" alt=\"Graph comparing FEG performance of a conventional and X-CFEG\" width=\"731\" height=\"457\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph.png 2106w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph-300x187.png 300w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph-1024x640.png 1024w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph-768x480.png 768w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph-1536x960.png 1536w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/Talos-XCFEG-blog-image-graph-2048x1280.png 2048w\" sizes=\"auto, (max-width: 731px) 100vw, 731px\" \/><\/p>\n<p style=\"text-align: center\"><em>The X-CFEG is superior to other guns with respect to brightness, source size, and energy spread. Here the titanium edges of the environmentally friendly Li Battery are shown from the same area. The difference is shown between 0.28 eV (X-CFEG, red) and 1.0 eV (conventional FEG, green) energy resolution. More peaks and more details are visible in the X-CFEG spectrum (red) which provides insights in the chemical structure that are not visible with the conventional FEGs.<\/em><\/p>\n<p>Surface plasmon resonances are found within a wide range of biomedical applications, like cellular imaging, molecular diagnosis, and targeted therapy. Moreover, also in photonic applications, in semiconductor and for polymeric applications these surface resonances are used. Noble metal nanoparticles and nanorods are the most visualized systems. The electron beam of the X-CFEG can excite the surface plasmon resonances so it is possible to measure and image them with high resolution using EELS. With the high energy resolution and high brightness that X-CFEG provides, the Talos can accurately measure the diameter of gold nanorods and show how their resonance mode shifts with diameter, bringing researchers closer to understanding how these nanorods behave.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-12378 aligncenter\" title=\"High-resolution TEM imaging of plasmon excitation in a catalytic reaction\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/au_plasmon-gif.gif\" alt=\"High-resolution TEM imaging of plasmon excitation in a catalytic reaction\" width=\"800\" height=\"233\" \/><\/p>\n<p style=\"text-align: center\"><em>In the video, different energy filtered TEM images were compiled from the spectrum images dataset collected from our Talos TEM, equipped with X-CFEG with 0.3 eV energy resolution. The colors in the video indicate the strength of surface plasmon excitation. For example, the yellow\/red color indicates a higher amount of energy loss that was absorbed by the localized surface plasmon resonance at the surface. In this example we observe localized surface plasmon resonances, eigen modes and coupling with each other within different Au nanorods. This is not visible with a conventional FEG. Sample courtesy Prof. Sara Bals From University of Antwerp<\/em><\/p>\n<p>Additionally, as the world moves toward low-carbon energy sources, scientists are exploring the usefulness of the chemical compound cobalt oxide as a catalyst for producing carbon oxide-free hydrogen gas as a future energy source. The combination of our X-CFEG with the Talos TEM makes it possible to understand these catalytic reactions with greater precision to improve the overall activity and make the world cleaner.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Accelerating materials development<\/strong><\/h2>\n<p>These are just a few of the ways the X-CFEG and Talos TEM can advance materials research and make the world cleaner, healthier and safer. Using these tools together, scientists can quickly and effortlessly obtain sharp, sub-nanometer resolution STEM images with high beam currents, leading to higher-quality EDXS and EELS analyses. With greater insight into the structure and chemistry of their samples, researchers are poised to speed up innovation as they tackle some of today\u2019s toughest materials science challenges.<\/p>\n<p>For more details and application examples using our Thermo Scientific X-CFEG, read our e-book, <a href=\"https:\/\/ter.li\/6tdr4f\">Unprecedented X-CFEG for the Talos TEM<\/a>. Also, visit our <a href=\"https:\/\/ter.li\/adt3wr\">Talos F200i<\/a> and <a href=\"https:\/\/ter.li\/n7t47x\">Talos F200X G2<\/a> webpages.<\/p>\n<p>\/\/<\/p>\n<p><em>Yuri Rikers is a Product Marketing Manager at Thermo Fisher Scientific.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Atomic-scale high-resolution TEM As scientists in industry and academia increasingly require sub-nanometer information to better understand new materials\u2019 properties, transmission electron microscopy (TEM) has developed to deliver spatial and chemical information at the nanoscale in a wide variety of fields such as catalysis, metals, batteries, and polymers as well as novel materials to accelerate development<\/p>\n","protected":false},"author":960,"featured_media":12368,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[959,965],"tags":[937,942,950,955],"division":[],"class_list":{"0":"post-12366","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-fundamental-materials-research","8":"category-transmission-electron-microscopy","9":"tag-chemical","10":"tag-energy-materials","11":"tag-metals","12":"tag-polymer-plastics","13":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Field Emission Electron Gun - High-Resolution TEM - Advancing Materials<\/title>\n<meta name=\"description\" content=\"A cold field-emission electron gun enables atomic-scale high-resolution TEM for catalysis, metals, batteries, and polymers research.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM\" \/>\n<meta property=\"og:description\" content=\"A cold field-emission electron gun enables atomic-scale high-resolution TEM for catalysis, metals, batteries, and polymers research.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-01-20T06:01:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-12T21:35:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png\" \/>\n\t<meta property=\"og:image:width\" content=\"601\" \/>\n\t<meta property=\"og:image:height\" content=\"220\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Yuri Rikers\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Yuri Rikers\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/\"},\"author\":{\"name\":\"Yuri Rikers\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/f92a185423899e665421222d6b550565\"},\"headline\":\"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM\",\"datePublished\":\"2022-01-20T06:01:55+00:00\",\"dateModified\":\"2023-06-12T21:35:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/\"},\"wordCount\":914,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/01\\\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png\",\"keywords\":[\"Chemical\",\"Energy Materials\",\"Metals\",\"Polymer\\\/Plastics\"],\"articleSection\":[\"Fundamental Materials Research\",\"Transmission Electron Microscopy\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/\",\"name\":\"Field Emission Electron Gun - High-Resolution TEM - Advancing Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/01\\\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png\",\"datePublished\":\"2022-01-20T06:01:55+00:00\",\"dateModified\":\"2023-06-12T21:35:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/f92a185423899e665421222d6b550565\"},\"description\":\"A cold field-emission electron gun enables atomic-scale high-resolution TEM for catalysis, metals, batteries, and polymers research.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/01\\\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/01\\\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png\",\"width\":601,\"height\":220},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/f92a185423899e665421222d6b550565\",\"name\":\"Yuri Rikers\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/875970ce94eccaacc01c421b451b3572628a13b2d064a1fc51dc263cc8675886?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/875970ce94eccaacc01c421b451b3572628a13b2d064a1fc51dc263cc8675886?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/875970ce94eccaacc01c421b451b3572628a13b2d064a1fc51dc263cc8675886?s=96&d=mm&r=g\",\"caption\":\"Yuri Rikers\"},\"sameAs\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/microscopy\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/yuririkers\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Field Emission Electron Gun - High-Resolution TEM - Advancing Materials","description":"A cold field-emission electron gun enables atomic-scale high-resolution TEM for catalysis, metals, batteries, and polymers research.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/","og_locale":"en_US","og_type":"article","og_title":"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM","og_description":"A cold field-emission electron gun enables atomic-scale high-resolution TEM for catalysis, metals, batteries, and polymers research.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-01-20T06:01:55+00:00","article_modified_time":"2023-06-12T21:35:01+00:00","og_image":[{"width":601,"height":220,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png","type":"image\/png"}],"author":"Yuri Rikers","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Yuri Rikers","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/"},"author":{"name":"Yuri Rikers","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/f92a185423899e665421222d6b550565"},"headline":"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM","datePublished":"2022-01-20T06:01:55+00:00","dateModified":"2023-06-12T21:35:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/"},"wordCount":914,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png","keywords":["Chemical","Energy Materials","Metals","Polymer\/Plastics"],"articleSection":["Fundamental Materials Research","Transmission Electron Microscopy"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/","name":"Field Emission Electron Gun - High-Resolution TEM - Advancing Materials","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png","datePublished":"2022-01-20T06:01:55+00:00","dateModified":"2023-06-12T21:35:01+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/f92a185423899e665421222d6b550565"},"description":"A cold field-emission electron gun enables atomic-scale high-resolution TEM for catalysis, metals, batteries, and polymers research.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png","width":601,"height":220},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/cold-field-emission-electron-gun-for-atomic-scale-high-resolution-tem\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"Accelerate Materials Insights with Our New Cold Field Emission Electron Gun for Atomic-Scale High-Resolution TEM"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/f92a185423899e665421222d6b550565","name":"Yuri Rikers","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/875970ce94eccaacc01c421b451b3572628a13b2d064a1fc51dc263cc8675886?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/875970ce94eccaacc01c421b451b3572628a13b2d064a1fc51dc263cc8675886?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/875970ce94eccaacc01c421b451b3572628a13b2d064a1fc51dc263cc8675886?s=96&d=mm&r=g","caption":"Yuri Rikers"},"sameAs":["https:\/\/admin.acceleratingscience.com\/microscopy"],"url":"https:\/\/admin.acceleratingscience.com\/author\/yuririkers\/"}]}},"taxonomy_info":{"category":[{"value":959,"label":"Fundamental Materials Research"},{"value":965,"label":"Transmission Electron Microscopy"}],"post_tag":[{"value":937,"label":"Chemical"},{"value":942,"label":"Energy Materials"},{"value":950,"label":"Metals"},{"value":955,"label":"Polymer\/Plastics"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/01\/2022-MS-Cold-FEG-on-Talos-Internal-announcement-email-515117-600x220-ExShade.png",601,220,false],"author_info":{"display_name":"Yuri Rikers","author_link":"https:\/\/admin.acceleratingscience.com\/author\/yuririkers\/"},"comment_info":1,"category_info":[{"term_id":959,"name":"Fundamental Materials Research","slug":"fundamental-materials-research","term_group":0,"term_taxonomy_id":959,"taxonomy":"category","description":"","parent":0,"count":80,"filter":"raw","meta":[],"cat_ID":959,"category_count":80,"category_description":"","cat_name":"Fundamental Materials Research","category_nicename":"fundamental-materials-research","category_parent":0},{"term_id":965,"name":"Transmission Electron Microscopy","slug":"transmission-electron-microscopy","term_group":0,"term_taxonomy_id":965,"taxonomy":"category","description":"","parent":0,"count":17,"filter":"raw","meta":[],"cat_ID":965,"category_count":17,"category_description":"","cat_name":"Transmission Electron Microscopy","category_nicename":"transmission-electron-microscopy","category_parent":0}],"tag_info":[{"term_id":937,"name":"Chemical","slug":"chemical","term_group":0,"term_taxonomy_id":937,"taxonomy":"post_tag","description":"","parent":0,"count":20,"filter":"raw","meta":[]},{"term_id":942,"name":"Energy Materials","slug":"energy-materials","term_group":0,"term_taxonomy_id":942,"taxonomy":"post_tag","description":"","parent":0,"count":29,"filter":"raw","meta":[]},{"term_id":950,"name":"Metals","slug":"metals","term_group":0,"term_taxonomy_id":950,"taxonomy":"post_tag","description":"","parent":0,"count":23,"filter":"raw","meta":[]},{"term_id":955,"name":"Polymer\/Plastics","slug":"polymer-plastics","term_group":0,"term_taxonomy_id":955,"taxonomy":"post_tag","description":"","parent":0,"count":220,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/12366","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/960"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=12366"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/12366\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/12368"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=12366"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=12366"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=12366"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=12366"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}