{"id":12845,"date":"2019-05-23T17:20:44","date_gmt":"2019-05-23T22:20:44","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/materials\/?p=12845"},"modified":"2022-07-12T13:35:05","modified_gmt":"2022-07-12T18:35:05","slug":"improving-the-additive-manufacturing-process-with-microct","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/improving-the-additive-manufacturing-process-with-microct\/","title":{"rendered":"Improving the Additive Manufacturing Process with MicroCT"},"content":{"rendered":"<p>Micro-computer tomography (microCT) is a powerful, non-destructive tomography technique that enables researchers to see the interior of objects at microscale. One area where it\u2019s gaining traction is in the world of additive manufacturing.<\/p>\n<p>While additive manufacturing has experienced rapid growth in recent years, the complex parts produced must be carefully designed, tested, and manufactured, and then inspected for quality control. With microCT, components are kept intact while examined, making it a desirable process for verifying the quality of parts in a variety of industries ranging from aerospace to automotive to medicine.<\/p>\n<p>Using tools such as the <a href=\"https:\/\/ter.li\/2e1n9f\">Thermo Scientific HeliScan<\/a>, engineers can scan large volumes of data in the regions they want to explore using a helical trajectory and iterative reconstruction technology. The process uses one continuous helical scan to avoid stitching together images, producing high-resolution 3D models of samples up to 200 millimeters wide.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/quantitative-analysis.jpg\" \/><\/p>\n<p><em>Using microCT, engineers identify non-uniformities in the diameter of the cell wall of a titanium scaffolding prototype created using additive manufacturing. The measurements do not match those indicated by the CAD drawing. <\/em><\/p>\n<p>With microCT, engineers are able to discover defects in the internal structure of components produced through additive manufacturing at below 400 nanometer resolutions. \u00a0By measuring the dimensions of complex parts down to the nanometer scale, for example, microCT can pinpoint internal surfaces, lattice parts and other areas of a component that haven\u2019t been uniformly produced (see Figure 1).<\/p>\n<p>MicroCT can also be used to visualize and quantify pores or voids created during the additive manufacturing process. By comparing different areas of a component, for example, engineers can ascertain whether the pores are unequally distributed on the top and bottom and use this information to strengthen the structure.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle.png\" \/><\/p>\n<p><em>Using microCT in combination with <a href=\"https:\/\/ter.li\/pp3kjf\">Thermo Fisher Avizo software<\/a>, engineers developed a high-resolution 3D model of a titanium nozzle used for gas-mixing injection. Examining a cross section of the rendering, they were able to identify defects such as broken inner-channel walls and surface roughness. <\/em><\/p>\n<p>Using microCT, engineers can also uncover impurities in the 3D printing process such as broken interior walls caused by non-melted powder particles and surface roughness due to sintered powder particles (see Figure 2).<\/p>\n<p>Oftentimes, HeliScan MicroCT is used as part of a multi-scale workflow in which engineers combine microCT with other techniques such as <a href=\"https:\/\/ter.li\/wsizlm\">focused ion beam-scanning electron microscopes<\/a>, <a href=\"https:\/\/ter.li\/6lhoby\">scanning transmission electron microscopes<\/a> to obtain information about an additive manufacturing component at different scales. Images from the various techniques can be correlated with the complementary information overlaid to obtain very detailed information.<\/p>\n<p>Using microCT in additive manufacturing, engineers can dramatically improve their production processes. As more technicians integrate microCT into the additive manufacturing process, the technique will lead to stronger, more durable components that advance a wide range of industries.<\/p>\n<p><a href=\"https:\/\/ter.li\/51387t\" target=\"_blank\" rel=\"noopener noreferrer\"><img decoding=\"async\" style=\"margin-left: auto;margin-right: auto\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/microct-additive-manufacturing.jpg\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/microscopy\/subscribe-to-accelerating-microscopy\/\" target=\"_blank\" rel=\"noopener noreferrer\"><em>Subscribe now<\/em><\/a><em> to receive new Accelerating Microscopy posts straight to your inbox. For more information about Thermo Scientific microscopy instruments, visit <\/em><a href=\"https:\/\/ter.li\/m3uq6f\"><em>thermofisher.com\/em<\/em><\/a><em>.<\/em><\/p>\n<p>Dirk Laeveren is a product marketing manager at Thermo Fisher Scientific.<\/p>\n<p>&nbsp;<\/p>\n<p>To learn more about microCT, <a href=\"https:\/\/ter.li\/wdmpoj\">fill out this form<\/a> to speak with an expert.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Micro-computer tomography (microCT) is a powerful, non-destructive tomography technique that enables researchers to see the interior of objects at microscale. One area where it\u2019s gaining traction is in the world of additive manufacturing. While additive manufacturing has experienced rapid growth in recent years, the complex parts produced must be carefully designed, tested, and manufactured, and<\/p>\n","protected":false},"author":887,"featured_media":12849,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[998,1052],"tags":[985,930,1093,1025,1040,1023,1104,1027,1105,997,1106],"division":[],"class_list":["post-12845","post","type-post","status-publish","format-standard","has-post-thumbnail","category-breakthroughs-in-materials-science","category-general","tag-3d","tag-additive-manufacturing","tag-avizo","tag-heliscan","tag-materials-research","tag-materials-science","tag-micro-comuter-tomography","tag-microct","tag-microscale","tag-microscopy2022","tag-tomography","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Improving the Additive Manufacturing Process with MicroCT<\/title>\n<meta name=\"description\" content=\"Micro-computer tomography (microCT), a technique that enables researchers to see inside objects at microscale, is gaining traction in additive manufacturing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/improving-the-additive-manufacturing-process-with-microct\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Improving the Additive Manufacturing Process with MicroCT\" \/>\n<meta property=\"og:description\" content=\"Micro-computer tomography (microCT), a technique that enables researchers to see inside objects at microscale, is gaining traction in additive manufacturing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2019-05-23T22:20:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-12T18:35:05+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1401\" \/>\n\t<meta property=\"og:image:height\" content=\"957\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Dirk Laeveren\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Dirk Laeveren\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/\"},\"author\":{\"name\":\"Dirk Laeveren\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/881d1d12b688948abf8fb192572ba1e2\"},\"headline\":\"Improving the Additive Manufacturing Process with MicroCT\",\"datePublished\":\"2019-05-23T22:20:44+00:00\",\"dateModified\":\"2022-07-12T18:35:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/\"},\"wordCount\":513,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/04\\\/nozzle-1.png\",\"keywords\":[\"3D\",\"Additive Manufacturing\",\"Avizo\",\"heliscan\",\"Materials Research\",\"Materials Science\",\"micro-comuter tomography\",\"microct\",\"microscale\",\"Microscopy2022\",\"tomography\"],\"articleSection\":[\"Breakthroughs in Materials Science\",\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/\",\"name\":\"Improving the Additive Manufacturing Process with MicroCT\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/04\\\/nozzle-1.png\",\"datePublished\":\"2019-05-23T22:20:44+00:00\",\"dateModified\":\"2022-07-12T18:35:05+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/881d1d12b688948abf8fb192572ba1e2\"},\"description\":\"Micro-computer tomography (microCT), a technique that enables researchers to see inside objects at microscale, is gaining traction in additive manufacturing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/04\\\/nozzle-1.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/04\\\/nozzle-1.png\",\"width\":1401,\"height\":957},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/improving-the-additive-manufacturing-process-with-microct\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Improving the Additive Manufacturing Process with MicroCT\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/881d1d12b688948abf8fb192572ba1e2\",\"name\":\"Dirk Laeveren\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9cd9c7289e4d37347f48375c5280f78fa7673c5436ff286d10b7bedaa56b94cf?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9cd9c7289e4d37347f48375c5280f78fa7673c5436ff286d10b7bedaa56b94cf?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/9cd9c7289e4d37347f48375c5280f78fa7673c5436ff286d10b7bedaa56b94cf?s=96&d=mm&r=g\",\"caption\":\"Dirk Laeveren\"},\"sameAs\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/microscopy\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/dirklaeveren\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Improving the Additive Manufacturing Process with MicroCT","description":"Micro-computer tomography (microCT), a technique that enables researchers to see inside objects at microscale, is gaining traction in additive manufacturing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/improving-the-additive-manufacturing-process-with-microct\/","og_locale":"en_US","og_type":"article","og_title":"Improving the Additive Manufacturing Process with MicroCT","og_description":"Micro-computer tomography (microCT), a technique that enables researchers to see inside objects at microscale, is gaining traction in additive manufacturing.","og_url":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2019-05-23T22:20:44+00:00","article_modified_time":"2022-07-12T18:35:05+00:00","og_image":[{"width":1401,"height":957,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1.png","type":"image\/png"}],"author":"Dirk Laeveren","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Dirk Laeveren","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#article","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/"},"author":{"name":"Dirk Laeveren","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/881d1d12b688948abf8fb192572ba1e2"},"headline":"Improving the Additive Manufacturing Process with MicroCT","datePublished":"2019-05-23T22:20:44+00:00","dateModified":"2022-07-12T18:35:05+00:00","mainEntityOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/"},"wordCount":513,"commentCount":0,"image":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1.png","keywords":["3D","Additive Manufacturing","Avizo","heliscan","Materials Research","Materials Science","micro-comuter tomography","microct","microscale","Microscopy2022","tomography"],"articleSection":["Breakthroughs in Materials Science","General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/","url":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/","name":"Improving the Additive Manufacturing Process with MicroCT","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#primaryimage"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1.png","datePublished":"2019-05-23T22:20:44+00:00","dateModified":"2022-07-12T18:35:05+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/881d1d12b688948abf8fb192572ba1e2"},"description":"Micro-computer tomography (microCT), a technique that enables researchers to see inside objects at microscale, is gaining traction in additive manufacturing.","breadcrumb":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1.png","width":1401,"height":957},{"@type":"BreadcrumbList","@id":"https:\/\/admin.acceleratingscience.com\/materials\/improving-the-additive-manufacturing-process-with-microct\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"Improving the Additive Manufacturing Process with MicroCT"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/881d1d12b688948abf8fb192572ba1e2","name":"Dirk Laeveren","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/9cd9c7289e4d37347f48375c5280f78fa7673c5436ff286d10b7bedaa56b94cf?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/9cd9c7289e4d37347f48375c5280f78fa7673c5436ff286d10b7bedaa56b94cf?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/9cd9c7289e4d37347f48375c5280f78fa7673c5436ff286d10b7bedaa56b94cf?s=96&d=mm&r=g","caption":"Dirk Laeveren"},"sameAs":["https:\/\/admin.acceleratingscience.com\/microscopy"],"url":"https:\/\/admin.acceleratingscience.com\/author\/dirklaeveren\/"}]}},"taxonomy_info":{"category":[{"value":998,"label":"Breakthroughs in Materials Science"},{"value":1052,"label":"General"}],"post_tag":[{"value":985,"label":"3D"},{"value":930,"label":"Additive Manufacturing"},{"value":1093,"label":"Avizo"},{"value":1025,"label":"heliscan"},{"value":1040,"label":"Materials Research"},{"value":1023,"label":"Materials Science"},{"value":1104,"label":"micro-comuter tomography"},{"value":1027,"label":"microct"},{"value":1105,"label":"microscale"},{"value":997,"label":"Microscopy2022"},{"value":1106,"label":"tomography"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/04\/nozzle-1-1024x699.png",760,519,true],"author_info":{"display_name":"Dirk Laeveren","author_link":"https:\/\/admin.acceleratingscience.com\/author\/dirklaeveren\/"},"comment_info":0,"category_info":[{"term_id":998,"name":"Breakthroughs in Materials Science","slug":"breakthroughs-in-materials-science","term_group":0,"term_taxonomy_id":998,"taxonomy":"category","description":"","parent":0,"count":25,"filter":"raw","meta":[],"cat_ID":998,"category_count":25,"category_description":"","cat_name":"Breakthroughs in Materials Science","category_nicename":"breakthroughs-in-materials-science","category_parent":0},{"term_id":1052,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":1052,"taxonomy":"category","description":"","parent":0,"count":46,"filter":"raw","meta":[],"cat_ID":1052,"category_count":46,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":[{"term_id":985,"name":"3D","slug":"3d","term_group":0,"term_taxonomy_id":985,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":930,"name":"Additive Manufacturing","slug":"additive-manufacturing","term_group":0,"term_taxonomy_id":930,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw","meta":[]},{"term_id":1093,"name":"Avizo","slug":"avizo","term_group":0,"term_taxonomy_id":1093,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]},{"term_id":1025,"name":"heliscan","slug":"heliscan","term_group":0,"term_taxonomy_id":1025,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":1040,"name":"Materials Research","slug":"materials-research","term_group":0,"term_taxonomy_id":1040,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":1023,"name":"Materials Science","slug":"materials-science","term_group":0,"term_taxonomy_id":1023,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]},{"term_id":1104,"name":"micro-comuter tomography","slug":"micro-comuter-tomography","term_group":0,"term_taxonomy_id":1104,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":1027,"name":"microct","slug":"microct","term_group":0,"term_taxonomy_id":1027,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":1105,"name":"microscale","slug":"microscale","term_group":0,"term_taxonomy_id":1105,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":997,"name":"Microscopy2022","slug":"microscopy2022","term_group":0,"term_taxonomy_id":997,"taxonomy":"post_tag","description":"","parent":0,"count":52,"filter":"raw","meta":[]},{"term_id":1106,"name":"tomography","slug":"tomography","term_group":0,"term_taxonomy_id":1106,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/12845","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/887"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=12845"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/12845\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/12849"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=12845"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=12845"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=12845"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=12845"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}