{"id":13194,"date":"2022-09-01T09:00:40","date_gmt":"2022-09-01T14:00:40","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/materials\/?p=13194"},"modified":"2022-09-01T10:59:43","modified_gmt":"2022-09-01T15:59:43","slug":"total-materia-database-verify-metal-grades-optical-emission-spectroscopy","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/","title":{"rendered":"Total Materia Database Helps Users Quickly Verify Metal Grades"},"content":{"rendered":"<h2 style=\"font-size: 100%\"><strong>New metal grades for novel materials<\/strong><\/h2>\n<p>As materials scientists work to develop more durable and lighter materials, new metal grades are being introduced at an unprecedented rate. Today, the steel industry defines more than 3,500 different materials differentiated by their chemical, mechanical, and physical properties, according to the World Steel Association. Moreover, approximately 75% of today\u2019s steel grades have been developed in just the last 20 years.<\/p>\n<p>For steel plans and metal processing industries ranging from automotive to petrochemical to energy materials analysis, identifying the grade of specific metals and alloys is critical\u2014both when verifying the quality of incoming materials and confirming the composition of finished products.<\/p>\n<p>Yet the verification process is often complicated. For the many different metals and alloys sold today, a plethora of classification systems exist to keep all the standards regulated within the industry. Wading through these classification systems can take hours, and the information obtained can be out-of-date.<\/p>\n<h2 style=\"font-size: 100%\"><strong>A comprehensive metals database<\/strong><\/h2>\n<p>To help users of our<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/x-ray-fluorescence-xrf.html?cid=fl-cad-xray&amp;CID=7014z000001YDYtAAO&amp;utm_source=Comms-PR&amp;utm_medium=AM+Blog&amp;utm_campaign=7014z000001YDYtAAO\"> X-ray fluorescence (XRF)<\/a> and <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/optical-emission-spectrometry-oes.html?cid=fl-cad-oes&amp;CID=7014z000001YDYtAAO&amp;utm_source=Comms-PR&amp;utm_medium=AM+Blog&amp;utm_campaign=7014z000001YDYtAAO\">optical emission spectrometers<\/a> get the quick and up-to-date information they need, Thermo Fisher Scientific offers Total Materia, the most comprehensive metals database on the market.<\/p>\n<p style=\"text-align: center\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-13196\" src=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/SpectrometerGraph-300x265.jpg\" alt=\"Total Materia\" width=\"334\" height=\"295\" srcset=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/SpectrometerGraph-300x265.jpg 300w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/SpectrometerGraph-1024x906.jpg 1024w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/SpectrometerGraph-768x679.jpg 768w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/SpectrometerGraph-310x274.jpg 310w, https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/SpectrometerGraph.jpg 1400w\" sizes=\"auto, (max-width: 334px) 100vw, 334px\" \/><br \/>\n<em>The world\u2019s most comprehensive metals database, Total Materia helps users quickly and accurately identify the metal grades of raw materials and finished products\u2014right from their OES and XRF spectrometers.<\/em><\/p>\n<p>With Total Materia, users can access more than 15 million metal property records for iron and steel, ferrous alloys, aluminum, copper, titanium, magnesium, tin, zinc, lead, nickel, and more\u2014without accessing the Internet. Instead, they can directly export this data to their <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/oxsas-software.html?CID=7014z000001YDYtAAO&amp;utm_source=Comms-PR&amp;utm_medium=AM+Blog&amp;utm_campaign=7014z000001YDYtAAO\">OXSAS Software<\/a> for use with their OES and XRF spectrometers\u2014replacing hours of tedious research with just a few clicks.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Access to more than 350,000 material grades with Total Materia<\/strong><\/h2>\n<p>Total Materia provides more than 350,000 material grades from all major organizations and associations in 74 countries. It offers a wide range of information including chemical composition, standard reference, application guidelines, mechanical properties, heat treatment details, properties at elevated temperatures, fatigue properties, and more. It also includes tables with equivalent materials worldwide and applied artificial intelligence within the SmartCross module for cross-referencing.<\/p>\n<p>Users can search by material, standard, properties, and several other advanced search methods to find information in seconds. Global information from thousands of standards is routinely updated\u2014ensuring it is always up-to-date. In addition, users can obtain free technical support from Total Materia specialists. To learn more and get a 60-day free trial, please see our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/products-and-services\/promotions\/industrial\/analyzing-grades-of-metals.html?CID=7014z000001YDYtAAO&amp;utm_source=Comms-PR&amp;utm_medium=AM+Blog&amp;utm_campaign=7014z000001YDYtAAO\">Analyzing Grades of Metals<\/a> webpage.<\/p>\n<p>&nbsp;<\/p>\n<hr \/>\n<p><em>Wilhelm Sanders is a Product Manager for Spark OES at Thermo Fisher Scientific<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>New metal grades for novel materials As materials scientists work to develop more durable and lighter materials, new metal grades are being introduced at an unprecedented rate. Today, the steel industry defines more than 3,500 different materials differentiated by their chemical, mechanical, and physical properties, according to the World Steel Association. Moreover, approximately 75% of<\/p>\n","protected":false},"author":1678,"featured_media":13195,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[1145,968],"tags":[950,1146],"division":[],"class_list":{"0":"post-13194","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-optical-emission-spectroscopy","8":"category-spectroscopy-spectrometry","9":"tag-metals","10":"tag-total-materia","11":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.4 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Total Materia - Optical Emission Spectroscopy - Advancing Materials<\/title>\n<meta name=\"description\" content=\"Total Materia helps users quickly and accurately identify the metal grades of raw materials right from their OES and XRF spectrometers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Total Materia Database Helps Users Quickly Verify Metal Grades\" \/>\n<meta property=\"og:description\" content=\"Total Materia helps users quickly and accurately identify the metal grades of raw materials right from their OES and XRF spectrometers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2022-09-01T14:00:40+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-01T15:59:43+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"800\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Wilhelm Sanders\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Wilhelm Sanders\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/\"},\"author\":{\"name\":\"Wilhelm Sanders\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/14e506c5e28fc8f1425bc1568e7dc4bf\"},\"headline\":\"Total Materia Database Helps Users Quickly Verify Metal Grades\",\"datePublished\":\"2022-09-01T14:00:40+00:00\",\"dateModified\":\"2022-09-01T15:59:43+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/\"},\"wordCount\":435,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/08\\\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg\",\"keywords\":[\"Metals\",\"Total Materia\"],\"articleSection\":[\"Optical emission spectroscopy\",\"Spectroscopy and Spectrometry\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/\",\"name\":\"Total Materia - Optical Emission Spectroscopy - Advancing Materials\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/08\\\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg\",\"datePublished\":\"2022-09-01T14:00:40+00:00\",\"dateModified\":\"2022-09-01T15:59:43+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/14e506c5e28fc8f1425bc1568e7dc4bf\"},\"description\":\"Total Materia helps users quickly and accurately identify the metal grades of raw materials right from their OES and XRF spectrometers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/08\\\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2022\\\/08\\\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg\",\"width\":1200,\"height\":800,\"caption\":\"Total Materia\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Total Materia Database Helps Users Quickly Verify Metal Grades\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/14e506c5e28fc8f1425bc1568e7dc4bf\",\"name\":\"Wilhelm Sanders\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b543648bccabcac3aeb5363dd369a980e7e32bf59813f34b04e480d36aa538ee?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b543648bccabcac3aeb5363dd369a980e7e32bf59813f34b04e480d36aa538ee?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b543648bccabcac3aeb5363dd369a980e7e32bf59813f34b04e480d36aa538ee?s=96&d=mm&r=g\",\"caption\":\"Wilhelm Sanders\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/wsanders\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Total Materia - Optical Emission Spectroscopy - Advancing Materials","description":"Total Materia helps users quickly and accurately identify the metal grades of raw materials right from their OES and XRF spectrometers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/","og_locale":"en_US","og_type":"article","og_title":"Total Materia Database Helps Users Quickly Verify Metal Grades","og_description":"Total Materia helps users quickly and accurately identify the metal grades of raw materials right from their OES and XRF spectrometers.","og_url":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2022-09-01T14:00:40+00:00","article_modified_time":"2022-09-01T15:59:43+00:00","og_image":[{"width":1200,"height":800,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg","type":"image\/jpeg"}],"author":"Wilhelm Sanders","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Wilhelm Sanders","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#article","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/"},"author":{"name":"Wilhelm Sanders","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/14e506c5e28fc8f1425bc1568e7dc4bf"},"headline":"Total Materia Database Helps Users Quickly Verify Metal Grades","datePublished":"2022-09-01T14:00:40+00:00","dateModified":"2022-09-01T15:59:43+00:00","mainEntityOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/"},"wordCount":435,"commentCount":0,"image":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg","keywords":["Metals","Total Materia"],"articleSection":["Optical emission spectroscopy","Spectroscopy and Spectrometry"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/","url":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/","name":"Total Materia - Optical Emission Spectroscopy - Advancing Materials","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#primaryimage"},"image":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg","datePublished":"2022-09-01T14:00:40+00:00","dateModified":"2022-09-01T15:59:43+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/14e506c5e28fc8f1425bc1568e7dc4bf"},"description":"Total Materia helps users quickly and accurately identify the metal grades of raw materials right from their OES and XRF spectrometers.","breadcrumb":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2.jpg","width":1200,"height":800,"caption":"Total Materia"},{"@type":"BreadcrumbList","@id":"https:\/\/admin.acceleratingscience.com\/materials\/total-materia-database-verify-metal-grades-optical-emission-spectroscopy\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"Total Materia Database Helps Users Quickly Verify Metal Grades"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/14e506c5e28fc8f1425bc1568e7dc4bf","name":"Wilhelm Sanders","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b543648bccabcac3aeb5363dd369a980e7e32bf59813f34b04e480d36aa538ee?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b543648bccabcac3aeb5363dd369a980e7e32bf59813f34b04e480d36aa538ee?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b543648bccabcac3aeb5363dd369a980e7e32bf59813f34b04e480d36aa538ee?s=96&d=mm&r=g","caption":"Wilhelm Sanders"},"url":"https:\/\/admin.acceleratingscience.com\/author\/wsanders\/"}]}},"taxonomy_info":{"category":[{"value":1145,"label":"Optical emission spectroscopy"},{"value":968,"label":"Spectroscopy and Spectrometry"}],"post_tag":[{"value":950,"label":"Metals"},{"value":1146,"label":"Total Materia"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2022\/08\/BEA-Total-Materia-Blog-Post-header_1200x800-2-1024x683.jpg",760,507,true],"author_info":{"display_name":"Wilhelm Sanders","author_link":"https:\/\/admin.acceleratingscience.com\/author\/wsanders\/"},"comment_info":0,"category_info":[{"term_id":1145,"name":"Optical emission spectroscopy","slug":"optical-emission-spectroscopy","term_group":0,"term_taxonomy_id":1145,"taxonomy":"category","description":"","parent":968,"count":2,"filter":"raw","meta":[],"cat_ID":1145,"category_count":2,"category_description":"","cat_name":"Optical emission spectroscopy","category_nicename":"optical-emission-spectroscopy","category_parent":968},{"term_id":968,"name":"Spectroscopy and Spectrometry","slug":"spectroscopy-spectrometry","term_group":0,"term_taxonomy_id":968,"taxonomy":"category","description":"","parent":0,"count":221,"filter":"raw","meta":[],"cat_ID":968,"category_count":221,"category_description":"","cat_name":"Spectroscopy and Spectrometry","category_nicename":"spectroscopy-spectrometry","category_parent":0}],"tag_info":[{"term_id":950,"name":"Metals","slug":"metals","term_group":0,"term_taxonomy_id":950,"taxonomy":"post_tag","description":"","parent":0,"count":23,"filter":"raw","meta":[]},{"term_id":1146,"name":"Total Materia","slug":"total-materia","term_group":0,"term_taxonomy_id":1146,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/13194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/1678"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=13194"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/13194\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/13195"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=13194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=13194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=13194"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=13194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}