{"id":15402,"date":"2026-04-07T10:11:31","date_gmt":"2026-04-07T15:11:31","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/materials\/?p=15402"},"modified":"2026-04-10T09:35:06","modified_gmt":"2026-04-10T14:35:06","slug":"detecting-microscopic-contaminants-on-aerospace-production-components","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/","title":{"rendered":"Detecting Microscopic Contaminants on Aerospace Production Components"},"content":{"rendered":"\n<h2 style=\"font-size: 100%\"><strong>How advanced SEM, EDS, and ToF-SIMS techniques ensure cleanliness, quality, and reliability in aerospace manufacturing<\/strong><\/h2>\n\n\n\n<p>In aerospace production,&nbsp;contamination detection and&nbsp;surface cleanliness directly&nbsp;impact&nbsp;performance, safety, and yield. Even microscopic contaminants\u2014undetectable to the naked eye\u2014can lead to&nbsp;adhesion&nbsp;failure, corrosion, or electrical malfunction, compromising both part quality and downstream manufacturing processes.<\/p>\n\n\n\n<p>Contaminants may originate from multiple sources:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Environmental exposure (dust, oils, or atmospheric deposits)<\/li>\n\n\n\n<li>Process residues from machining, coatings, or etching steps<\/li>\n\n\n\n<li>Accidental handling or transfer during assembly or packaging<\/li>\n<\/ul>\n\n\n\n<p>Because these contaminants are often non-metallic, overlapping, or carbon-rich, automated inspection systems frequently miss them or generate false positives. Without precise identification and source tracing, manufacturers face delays, rework, or costly scrappage, particularly in aerospace and defense industries, where cleanliness standards are among the most stringent in manufacturing.<\/p>\n\n\n\n<h2 style=\"font-size: 100%\"><strong>Advanced analytical techniques for contamination detection<\/strong><\/h2>\n\n\n\n<p>To help ensure contamination control and maintain process integrity, aerospace manufacturers are turning to advanced microscopy and surface analysis workflows that combine SEM imaging, EDS elemental analysis, and ToF-SIMS chemical mapping.<\/p>\n\n\n\n<h3 style=\"font-size: 100%\"><strong>SEM and backscatter imaging: Locating micron-scale contaminants<\/strong><\/h3>\n\n\n\n<p>Scanning electron microscopy (SEM) enables visualization of particles, films, or residues at the micron and sub-micron level. In particular, backscatter electron imaging enhances contrast between contaminants and base materials, helping isolate non-metallic inclusions or foreign debris.<\/p>\n\n\n\n<p>This approach reveals morphological and spatial information showing whether contamination is particulate, film-like, or embedded in the surface. By mapping the distribution of these contaminants, engineers can determine whether they result from processing, environment, or handling.<\/p>\n\n\n\n<h3 style=\"font-size: 100%\"><strong>EDS: Rapidly identifying elemental composition of contaminants<\/strong><\/h3>\n\n\n\n<p>Once contaminants are located, energy dispersive spectroscopy (EDS) provides immediate elemental composition data, identifying what the contaminant is and where it may have originated. Typical findings may include:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Silicon or aluminum particles from abrasive media<\/li>\n\n\n\n<li>Chlorine or sulfur residues from cleaning agents<\/li>\n\n\n\n<li>Sodium, calcium, or potassium salts from environmental exposure<\/li>\n<\/ul>\n\n\n\n<p>EDS allows rapid differentiation between organic, inorganic, and metallic contaminants, which is essential for root-cause analysis and corrective action.<\/p>\n\n\n\n<h3 style=\"font-size: 100%\"><strong>ToF-SIMS: Detecting organic and trace-level contaminants<\/strong><\/h3>\n\n\n\n<p>For organic residues and trace-level contamination, time-of-flight secondary ion mass spectrometry (ToF-SIMS) offers unmatched sensitivity. ToF-SIMS can detect light elements (H, C, N, O) and complex organics at the nanometer scale, provide molecular fingerprinting to confirm specific contamination sources, such as silicone films, hydrocarbon residues, or lubricants, and support depth profiling to determine whether contamination is superficial or embedded.<\/p>\n\n\n\n<p>Together,&nbsp;<a href=\"https:\/\/www.thermofisher.com\/global\/en\/home\/materials-science\/scanning-electron-microscopy-materials-science.html\">SEM, EDS, and ToF-SIMS systems<\/a>&nbsp;form a&nbsp;powerful&nbsp;complementary toolkit for comprehensive aerospace contamination detection and analysis.<\/p>\n\n\n\n<h2 style=\"font-size: 100%\"><strong>Integrating manual and automated inspection for reliable aerospace contamination detection<\/strong><\/h2>\n\n\n\n<p>While automation accelerates inspection, manual review remains essential for verifying contamination data and preventing false positives. For example, automated systems can mistake overlapping surface textures or carbon-rich regions for contaminants. Operator-guided confirmation using SEM and EDS ensures accuracy and reliability.<\/p>\n\n\n\n<p>Combining manual microscopy expertise with automated mapping tools delivers the best balance between throughput and diagnostic precision, particularly in MRO and production environments where speed and accuracy are critical.<\/p>\n\n\n\n<h2 style=\"font-size: 100%\"><strong>Benefits of aerospace contamination detection for production quality<\/strong><\/h2>\n\n\n\n<p>Implementing SEM, EDS, and ToF-SIMS in contamination analysis workflows helps aerospace manufacturers gain:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Rapid contamination detection and chemical source tracking<\/li>\n\n\n\n<li>Reduced production downtime through faster root-cause identification<\/li>\n\n\n\n<li>Improved process control and cleanliness verification<\/li>\n\n\n\n<li>Compliance with aerospace and defense cleanliness standards (e.g., MIL, ISO, and ASTM)<\/li>\n<\/ul>\n\n\n\n<p>These tools help ensure that&nbsp;every&nbsp;component&nbsp;leaving the production line meets performance and reliability standards,&nbsp;safeguarding mission-critical systems from the ground to orbit.<\/p>\n\n\n\n<p>As part of Thermo Fisher Scientific\u2019s contamination analysis workflows, these techniques support aerospace manufacturing quality assurance.<\/p>\n\n\n\n<h2 style=\"font-size: 100%\"><strong>Building confidence through surface cleanliness<\/strong><\/h2>\n\n\n\n<p>In high-stakes industries like aerospace manufacturing, even a microscopic contaminant can have macroscopic consequences. Thermo Fisher Scientific\u2019s suite of surface and microanalytical solutions help manufacturers detect, identify, and eliminate contamination before it impacts quality.<\/p>\n\n\n\n<p>With advanced techniques like SEM, EDS, and ToF-SIMS, engineers can ensure every production component meets the highest standards of cleanliness, safety, and performance.<\/p>\n\n\n\n<h2 style=\"font-size: 100%\"><strong>Learn more about how advanced materials characterization supports aerospace innovation in the eBook\u202f<em>Engineering confidence<\/em>.<\/strong><\/h2>\n\n\n\n<p>The eBook highlights a series of application examples demonstrating how Thermo Scientific\u2122 electron microscopy and surface analysis technologies help researchers and engineers investigate microstructures, evaluate coatings, analyze failure mechanisms, and optimize advanced materials used in aerospace and defense systems.<\/p>\n\n\n\n<p><a href=\"https:\/\/www.thermofisher.com\/global\/en\/home\/global\/forms\/industrial\/em-xps-analysis-for-aerospace-and-defense-innovation.html\"><strong>Read more &gt;<\/strong><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>How advanced SEM, EDS, and ToF-SIMS techniques ensure cleanliness, quality, and reliability in aerospace manufacturing In aerospace production,&nbsp;contamination detection and&nbsp;surface cleanliness directly&nbsp;impact&nbsp;performance, safety, and yield. Even microscopic contaminants\u2014undetectable to the naked eye\u2014can lead to&nbsp;adhesion&nbsp;failure, corrosion, or electrical malfunction, compromising both part quality and downstream manufacturing processes. Contaminants may originate from multiple sources: Because these contaminants<\/p>\n","protected":false},"author":1866,"featured_media":15405,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[1052,28,960,961,21],"tags":[],"division":[],"class_list":{"0":"post-15402","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general","8":"category-general-news-tips-trends","9":"category-manufacturing-processing","10":"category-process-control","11":"category-quality-control-and-assurance-verification","12":"entry"},"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Aerospace Contamination Detection Using SEM, EDS, ToF-SIMS<\/title>\n<meta name=\"description\" content=\"Learn how SEM, EDS, and ToF-SIMS enable precise aerospace contamination analysis to improve cleanliness, quality, and reliability.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Detecting Microscopic Contaminants on Aerospace Production Components\" \/>\n<meta property=\"og:description\" content=\"Learn how SEM, EDS, and ToF-SIMS enable precise aerospace contamination analysis to improve cleanliness, quality, and reliability.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-04-07T15:11:31+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-10T14:35:06+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Salom\u00e9 Larmier\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Salom\u00e9 Larmier\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/\"},\"author\":{\"name\":\"Salom\u00e9 Larmier\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/58feb04de390a39b557d536dbee0c5f3\"},\"headline\":\"Detecting Microscopic Contaminants on Aerospace Production Components\",\"datePublished\":\"2026-04-07T15:11:31+00:00\",\"dateModified\":\"2026-04-10T14:35:06+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/\"},\"wordCount\":721,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2026\\\/04\\\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg\",\"articleSection\":[\"General\",\"General News, Tips, and Trends\",\"Manufacturing and Processing\",\"Process Control\",\"QA\\\/QC Verification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/\",\"name\":\"Aerospace Contamination Detection Using SEM, EDS, ToF-SIMS\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2026\\\/04\\\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg\",\"datePublished\":\"2026-04-07T15:11:31+00:00\",\"dateModified\":\"2026-04-10T14:35:06+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/58feb04de390a39b557d536dbee0c5f3\"},\"description\":\"Learn how SEM, EDS, and ToF-SIMS enable precise aerospace contamination analysis to improve cleanliness, quality, and reliability.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2026\\\/04\\\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2026\\\/04\\\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg\",\"width\":1920,\"height\":450,\"caption\":\"Detecting Microscopic Contaminants on Aerospace Production Components\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/detecting-microscopic-contaminants-on-aerospace-production-components\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Detecting Microscopic Contaminants on Aerospace Production Components\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/58feb04de390a39b557d536dbee0c5f3\",\"name\":\"Salom\u00e9 Larmier\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5238e70e404185710afa31a44958dc3706181a03f0ff9ec3cba100553b97a763?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5238e70e404185710afa31a44958dc3706181a03f0ff9ec3cba100553b97a763?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/5238e70e404185710afa31a44958dc3706181a03f0ff9ec3cba100553b97a763?s=96&d=mm&r=g\",\"caption\":\"Salom\u00e9 Larmier\"},\"jobTitle\":\"Sales Development Representative III, Analytical Instruments Group\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/salomelarmier\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Aerospace Contamination Detection Using SEM, EDS, ToF-SIMS","description":"Learn how SEM, EDS, and ToF-SIMS enable precise aerospace contamination analysis to improve cleanliness, quality, and reliability.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/","og_locale":"en_US","og_type":"article","og_title":"Detecting Microscopic Contaminants on Aerospace Production Components","og_description":"Learn how SEM, EDS, and ToF-SIMS enable precise aerospace contamination analysis to improve cleanliness, quality, and reliability.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-04-07T15:11:31+00:00","article_modified_time":"2026-04-10T14:35:06+00:00","og_image":[{"width":1920,"height":450,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg","type":"image\/jpeg"}],"author":"Salom\u00e9 Larmier","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Salom\u00e9 Larmier","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/"},"author":{"name":"Salom\u00e9 Larmier","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/58feb04de390a39b557d536dbee0c5f3"},"headline":"Detecting Microscopic Contaminants on Aerospace Production Components","datePublished":"2026-04-07T15:11:31+00:00","dateModified":"2026-04-10T14:35:06+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/"},"wordCount":721,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg","articleSection":["General","General News, Tips, and Trends","Manufacturing and Processing","Process Control","QA\/QC Verification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/","name":"Aerospace Contamination Detection Using SEM, EDS, ToF-SIMS","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg","datePublished":"2026-04-07T15:11:31+00:00","dateModified":"2026-04-10T14:35:06+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/58feb04de390a39b557d536dbee0c5f3"},"description":"Learn how SEM, EDS, and ToF-SIMS enable precise aerospace contamination analysis to improve cleanliness, quality, and reliability.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1.jpg","width":1920,"height":450,"caption":"Detecting Microscopic Contaminants on Aerospace Production Components"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/detecting-microscopic-contaminants-on-aerospace-production-components\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"Detecting Microscopic Contaminants on Aerospace Production Components"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/58feb04de390a39b557d536dbee0c5f3","name":"Salom\u00e9 Larmier","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/5238e70e404185710afa31a44958dc3706181a03f0ff9ec3cba100553b97a763?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/5238e70e404185710afa31a44958dc3706181a03f0ff9ec3cba100553b97a763?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/5238e70e404185710afa31a44958dc3706181a03f0ff9ec3cba100553b97a763?s=96&d=mm&r=g","caption":"Salom\u00e9 Larmier"},"jobTitle":"Sales Development Representative III, Analytical Instruments Group","url":"https:\/\/admin.acceleratingscience.com\/author\/salomelarmier\/"}]}},"taxonomy_info":{"category":[{"value":1052,"label":"General"},{"value":28,"label":"General News, Tips, and Trends"},{"value":960,"label":"Manufacturing and Processing"},{"value":961,"label":"Process Control"},{"value":21,"label":"QA\/QC Verification"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2026\/04\/aerospace-a3-industrial-blog-large-banner-1920x450-1-1024x240.jpg",760,178,true],"author_info":{"display_name":"Salom\u00e9 Larmier","author_link":"https:\/\/admin.acceleratingscience.com\/author\/salomelarmier\/"},"comment_info":4,"category_info":[{"term_id":1052,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":1052,"taxonomy":"category","description":"","parent":0,"count":46,"filter":"raw","meta":[],"cat_ID":1052,"category_count":46,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":28,"name":"General News, Tips, and Trends","slug":"general-news-tips-trends","term_group":0,"term_taxonomy_id":28,"taxonomy":"category","description":"","parent":0,"count":72,"filter":"raw","meta":[],"cat_ID":28,"category_count":72,"category_description":"","cat_name":"General News, Tips, and Trends","category_nicename":"general-news-tips-trends","category_parent":0},{"term_id":960,"name":"Manufacturing and Processing","slug":"manufacturing-processing","term_group":0,"term_taxonomy_id":960,"taxonomy":"category","description":"","parent":0,"count":115,"filter":"raw","meta":[],"cat_ID":960,"category_count":115,"category_description":"","cat_name":"Manufacturing and Processing","category_nicename":"manufacturing-processing","category_parent":0},{"term_id":961,"name":"Process Control","slug":"process-control","term_group":0,"term_taxonomy_id":961,"taxonomy":"category","description":"","parent":0,"count":91,"filter":"raw","meta":[],"cat_ID":961,"category_count":91,"category_description":"","cat_name":"Process Control","category_nicename":"process-control","category_parent":0},{"term_id":21,"name":"QA\/QC Verification","slug":"quality-control-and-assurance-verification","term_group":0,"term_taxonomy_id":21,"taxonomy":"category","description":"","parent":0,"count":132,"filter":"raw","meta":[],"cat_ID":21,"category_count":132,"category_description":"","cat_name":"QA\/QC Verification","category_nicename":"quality-control-and-assurance-verification","category_parent":0}],"tag_info":false,"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/15402","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/1866"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=15402"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/15402\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/15405"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=15402"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=15402"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=15402"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=15402"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}