{"id":3479,"date":"2015-01-02T08:00:22","date_gmt":"2015-01-02T13:00:22","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=3479"},"modified":"2026-02-02T13:23:24","modified_gmt":"2026-02-02T19:23:24","slug":"analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/","title":{"rendered":"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers"},"content":{"rendered":"\n<p>Most polymerisation processes used to create modern plastic materials need the assistance of catalytic substances containing <a href=\"http:\/\/www.thermoscientific.com\/content\/dam\/tfs\/ATG\/CAD\/CAD%20Documents\/Application%20&amp;%20Technical%20Notes\/Elemental%20Analysis\/XRF\/CAD-Niton-Periodictable-fxl.pdf\" target=\"_blank\" rel=\"noopener\">elements<\/a> such as aluminum (Al), titanium (Ti), or zinc (Zn). Yet, it is vital to minimize the presence of catalysts in the finished product, in order to maintain its desirable properties.<\/p>\n\n\n\n<p>In addition to catalysts, a number of other charges and additives \u2013 plasticisers, lubricants, stabilizing agents, neutralisers, antioxidants, pigments \u2013 are used in the production process. These products contain elements such as magnesium (Mg), iron (Fe), Al, phosphorous (P), chlorine (Cl), calcium (Ca), chromium (Cr) or Ti.<\/p>\n\n\n\n<p>It is therefore necessary to conduct elemental analyses on the finished <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/materials-science-research\/polymer-analysis.html?icid=CAD_blog_materials_2015Jan\" target=\"_blank\" rel=\"noreferrer noopener\">polymer<\/a> in order to optimize control over processing. Plastics are generally electrical insulators, resistant to acids and therefore difficult to put into solution. This makes X-ray fluorescence (XRF) the preferred method to obtain rapid and precise analyses for most of the elements of the Mendeleev table. XRF occurs when a fluorescent (or secondary) x-ray is emitted from a sample that is being excited by a primary x-ray source. Because this fluorescence is unique to the elemental composition of the sample, XRF is an excellent technology for qualitative and quantitative analysis of the material composition.<\/p>\n\n\n\n<p><span style=\"font-size: 18pt\">Testing with a Sequential XRF Spectrometer<\/span><\/p>\n\n\n\n<p>The performance of a <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/arl-perform-x-sequential-x-ray-fluorescence-spectrometer.html\">Sequential X-Ray Fluorescence Spectrometer<\/a> for the analysis of trace elements in polymers was tested by measurement of a series of polypropylene (PP) standard samples. &nbsp;A Sequential XRF Spectrometer utilizing WDXRF is a standard test method for analytical laboratories serving diverse applications, including polymers.&nbsp; With this type of spectrometer, analysis of materials in varied sizes, coatings, layers, heterogeneities and inclusions or requiring wide elemental coverage, wide concentration ranges and varied samples matrices is achieved with desired precision and limits of detection. Sample types include conductive or non-conductive solids, liquids, loose powders, pressed pellets, fusion beads, pastes, granules and coatings.<\/p>\n\n\n\n<p>The results of the test show that an <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAHGABMFALXMAZE?icid=CAD_blog_materials_2026Jan\">XRF spectrometer<\/a> is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples. Similar performance would be obtained on polyethylene samples.<\/p>\n\n\n\n<p>Read the <em><a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/MSD\/Application-Notes\/AN41658-analysis-traces-polymer.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">Analysis of Traces in Polymers<\/a>\u00a0<\/em>application note to learn about the test procedure, the limits of detection and the repeatability for trace analysis in polymers (at both 2500 W and 4200 W power levels).<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Most polymerisation processes used to create modern plastic materials need the assistance of catalytic substances containing elements such as aluminum (Al), titanium (Ti), or zinc (Zn). Yet, it is vital to minimize the presence of catalysts in the finished product, in order to maintain its desirable properties. In addition to catalysts, a number of other<\/p>\n","protected":false},"author":43,"featured_media":14976,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","footnotes":""},"categories":[978,959,21,968],"tags":[937,955],"division":[],"class_list":{"0":"post-3479","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-fluorescence","8":"category-fundamental-materials-research","9":"category-quality-control-and-assurance-verification","10":"category-spectroscopy-spectrometry","11":"tag-chemical","12":"tag-polymer-plastics","13":"entry"},"_selected_authors":[806],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers<\/title>\n<meta name=\"description\" content=\"Learn why an XRF spectrometer is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers\" \/>\n<meta property=\"og:description\" content=\"Learn why an XRF spectrometer is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Materials\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-01-02T13:00:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-02T19:23:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"1500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Didier Bonvin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Didier Bonvin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/\"},\"author\":{\"name\":\"Didier Bonvin\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/d844b9e45f5bdbd51f019c8951036410\"},\"headline\":\"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers\",\"datePublished\":\"2015-01-02T13:00:22+00:00\",\"dateModified\":\"2026-02-02T19:23:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/\"},\"wordCount\":392,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2015\\\/01\\\/iStock-511190196.jpg\",\"keywords\":[\"Chemical\",\"Polymer\\\/Plastics\"],\"articleSection\":[\"Fluorescence\",\"Fundamental Materials Research\",\"QA\\\/QC Verification\",\"Spectroscopy and Spectrometry\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/\",\"name\":\"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2015\\\/01\\\/iStock-511190196.jpg\",\"datePublished\":\"2015-01-02T13:00:22+00:00\",\"dateModified\":\"2026-02-02T19:23:24+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/d844b9e45f5bdbd51f019c8951036410\"},\"description\":\"Learn why an XRF spectrometer is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2015\\\/01\\\/iStock-511190196.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/wp-content\\\/uploads\\\/sites\\\/7\\\/2015\\\/01\\\/iStock-511190196.jpg\",\"width\":2000,\"height\":1500,\"caption\":\"Laboratory test tubes and flasks with colored liquids on the periodic table of elements. Science chemistry concept. 3d\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/materials\\\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/\",\"name\":\"Advancing Materials\",\"description\":\"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/materials\\\/#\\\/schema\\\/person\\\/d844b9e45f5bdbd51f019c8951036410\",\"name\":\"Didier Bonvin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1e91408b8e51caf5094c5af5f0f6f7e897e4d241e31d06a5eeacb36ef50d735e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1e91408b8e51caf5094c5af5f0f6f7e897e4d241e31d06a5eeacb36ef50d735e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1e91408b8e51caf5094c5af5f0f6f7e897e4d241e31d06a5eeacb36ef50d735e?s=96&d=mm&r=g\",\"caption\":\"Didier Bonvin\"},\"description\":\"X-ray Product Manager at Thermo Fisher Scientific, Ecublens, Switzerland\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/didier-bonvinthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers","description":"Learn why an XRF spectrometer is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/","og_locale":"en_US","og_type":"article","og_title":"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers","og_description":"Learn why an XRF spectrometer is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples.","og_url":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/","og_site_name":"Advancing Materials","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-01-02T13:00:22+00:00","article_modified_time":"2026-02-02T19:23:24+00:00","og_image":[{"width":2000,"height":1500,"url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196.jpg","type":"image\/jpeg"}],"author":"Didier Bonvin","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Didier Bonvin","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/"},"author":{"name":"Didier Bonvin","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/d844b9e45f5bdbd51f019c8951036410"},"headline":"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers","datePublished":"2015-01-02T13:00:22+00:00","dateModified":"2026-02-02T19:23:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/"},"wordCount":392,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196.jpg","keywords":["Chemical","Polymer\/Plastics"],"articleSection":["Fluorescence","Fundamental Materials Research","QA\/QC Verification","Spectroscopy and Spectrometry"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/","url":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/","name":"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196.jpg","datePublished":"2015-01-02T13:00:22+00:00","dateModified":"2026-02-02T19:23:24+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/d844b9e45f5bdbd51f019c8951036410"},"description":"Learn why an XRF spectrometer is well suited to produce high precision results for the determination of Mg, Al, P, Cl, Fe, Ca and Ti in polymer samples.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196.jpg","width":2000,"height":1500,"caption":"Laboratory test tubes and flasks with colored liquids on the periodic table of elements. Science chemistry concept. 3d"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/materials\/analysis-of-traces-in-polymers-using-sequential-x-ray-fluorescence-spectrometers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/materials\/"},{"@type":"ListItem","position":2,"name":"Analysis of Traces in Polymers Using Sequential X-Ray Fluorescence Spectrometers"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#website","url":"https:\/\/admin.acceleratingscience.com\/materials\/","name":"Advancing Materials","description":"Spectroscopy, spectrometry, and materials science stories and solutions about advancing research and improving product development","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/materials\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/materials\/#\/schema\/person\/d844b9e45f5bdbd51f019c8951036410","name":"Didier Bonvin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1e91408b8e51caf5094c5af5f0f6f7e897e4d241e31d06a5eeacb36ef50d735e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1e91408b8e51caf5094c5af5f0f6f7e897e4d241e31d06a5eeacb36ef50d735e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1e91408b8e51caf5094c5af5f0f6f7e897e4d241e31d06a5eeacb36ef50d735e?s=96&d=mm&r=g","caption":"Didier Bonvin"},"description":"X-ray Product Manager at Thermo Fisher Scientific, Ecublens, Switzerland","url":"https:\/\/admin.acceleratingscience.com\/author\/didier-bonvinthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":978,"label":"Fluorescence"},{"value":959,"label":"Fundamental Materials Research"},{"value":21,"label":"QA\/QC Verification"},{"value":968,"label":"Spectroscopy and Spectrometry"}],"post_tag":[{"value":937,"label":"Chemical"},{"value":955,"label":"Polymer\/Plastics"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/materials\/wp-content\/uploads\/sites\/7\/2015\/01\/iStock-511190196-1024x768.jpg",760,570,true],"author_info":{"display_name":"Didier Bonvin","author_link":"https:\/\/admin.acceleratingscience.com\/author\/didier-bonvinthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":978,"name":"Fluorescence","slug":"fluorescence","term_group":0,"term_taxonomy_id":978,"taxonomy":"category","description":"","parent":968,"count":28,"filter":"raw","meta":[],"cat_ID":978,"category_count":28,"category_description":"","cat_name":"Fluorescence","category_nicename":"fluorescence","category_parent":968},{"term_id":959,"name":"Fundamental Materials Research","slug":"fundamental-materials-research","term_group":0,"term_taxonomy_id":959,"taxonomy":"category","description":"","parent":0,"count":80,"filter":"raw","meta":[],"cat_ID":959,"category_count":80,"category_description":"","cat_name":"Fundamental Materials Research","category_nicename":"fundamental-materials-research","category_parent":0},{"term_id":21,"name":"QA\/QC Verification","slug":"quality-control-and-assurance-verification","term_group":0,"term_taxonomy_id":21,"taxonomy":"category","description":"","parent":0,"count":132,"filter":"raw","meta":[],"cat_ID":21,"category_count":132,"category_description":"","cat_name":"QA\/QC Verification","category_nicename":"quality-control-and-assurance-verification","category_parent":0},{"term_id":968,"name":"Spectroscopy and Spectrometry","slug":"spectroscopy-spectrometry","term_group":0,"term_taxonomy_id":968,"taxonomy":"category","description":"","parent":0,"count":222,"filter":"raw","meta":[],"cat_ID":968,"category_count":222,"category_description":"","cat_name":"Spectroscopy and Spectrometry","category_nicename":"spectroscopy-spectrometry","category_parent":0}],"tag_info":[{"term_id":937,"name":"Chemical","slug":"chemical","term_group":0,"term_taxonomy_id":937,"taxonomy":"post_tag","description":"","parent":0,"count":20,"filter":"raw","meta":[]},{"term_id":955,"name":"Polymer\/Plastics","slug":"polymer-plastics","term_group":0,"term_taxonomy_id":955,"taxonomy":"post_tag","description":"","parent":0,"count":220,"filter":"raw","meta":[]}],"_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/3479","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/users\/43"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/comments?post=3479"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/posts\/3479\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media\/14976"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/media?parent=3479"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/categories?post=3479"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/tags?post=3479"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/materials\/wp-json\/wp\/v2\/division?post=3479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}