{"id":11444,"date":"2021-07-27T12:00:16","date_gmt":"2021-07-27T12:00:16","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/metals\/?p=11444"},"modified":"2026-07-28T20:29:40","modified_gmt":"2026-07-28T20:29:40","slug":"an-ideal-galvanized-steel-sample-collection-process","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/","title":{"rendered":"An Ideal Galvanized Steel Sample Collection Process"},"content":{"rendered":"<p>Galvanized (GI) steel is flat sheet steel which has been coated in a layer of zinc to help the metal resist corrosion. The <a href=\"https:\/\/www.gsa.gov\/real-estate\/historic-preservation\/historic-preservation-policy-tools\/preservation-tools-resources\/technical-documents?Form_Load=88553?bypassAkamaiCache=1507917842\">US General Services Administration<\/a> notes that galvanized sheet steel is typically used for flashing, gutters and downspouts, as well as for hot-dipped galvanized steel nails, roof and wall ornaments, and other building materials.<\/p>\n<p>Manufacturers of GI must meet certain specifications for the finished product to meet customer requirements.\u00a0 That can be a difficult task, as we outlined in previous articles.<\/p>\n<p>Part of the process of manufacturing quality galvanized sheet steel is to build a set of certified GI reference samples.<\/p>\n<p>When planning to build a set of certified GI reference samples, it is critical to consider the product mix of the production line.\u00a0 In order to prevent production measurements that are extrapolated from the base calibration curve, candidate samples should be collected at least 10% above and below the typical production range.<\/p>\n<p>Candidate samples should be collected following the ASTM A 754 \/ A754 M procedure, where full 9in. x 9in. panels are taken from the line. However, instead of immediately destroying the four satellite samples with W-S-W analysis, each of the five individual candidate samples (central sample and 4 satellite samples) should be measured on the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/online-non-contact-measurement-gauges\/metals-online-coating-weight-thickness-measurement\/metals-thickness-coating-weight-measurement-applications\/non-contact-coating-weight-gauges-metallic-coil-coating-lines.html?icid=CAD_blog_metals_2021July\">XRF coating weight gauge<\/a> that is being used.<\/p>\n<p>As the samples are measured, the fluorescence signals should be stored in a data file. With this approach it is possible to establish a calibration curve, post XRF-measurement, that is based on all 5 samples, four of which will have traceable values determined via the destructive ASTM A90 process.<\/p>\n<p>This method was proposed in the 1995 paper by M. Deka.<sup>1<\/sup>\u00a0 Including all the samples in the development of the calibration curve will increase the statistics of any least squares regression, because as pointed out above, there is some uncertainty in both the W-S-W process and the XRF measurement.\u00a0 For some <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/online-non-contact-measurement-gauges\/metals-online-coating-weight-thickness-measurement\/metals-thickness-coating-weight-measurement-applications\/non-contact-coating-weight-gauges-metallic-coil-coating-lines.html?icid=CAD_blog_metals_2021July\" target=\"_blank\" rel=\"noopener\">coating weight gauges<\/a>, the reproducibility of the XRF measurement, as defined by IEC 1336, is stated as +\/- 0.15% of the nominal coating weight or +\/- 0.1 gsm whichever is higher.\u00a0 When the human element is added, errors in sample placement can occur leading to a larger value, as much as 3.8 % as indicated in the 1992 paper from J. Leeker et al.<sup>2<\/sup>\u00a0 Additionally, there may also be a benefit of extending the calibration range with samples above and below the production range with the outlying satellite samples.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" style=\"border: 0;margin: 10px\" title=\"Ideal calibration curve using and developing traceable GI reference samples for galvanized steel\" src=\"http:\/\/www.thermofisher.com\/blog\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/galvsteelzincsample.jpg\" alt=\"Ideal calibration curve using and developing traceable GI reference samples for galvanized steel\" width=\"650\" height=\"348\" \/><\/p>\n<p><em>\u00a0<\/em><em>Ideal calibration curve using and developing traceable GI reference samples<\/em><\/p>\n<p>Taking full advantage of the ability to store XRF voltages from GI samples, this method of developing GI reference samples can help minimize the observed error in online coating weight calibration curves.<\/p>\n<p>For more details, read the white paper <em><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/challenges-associated-with-developing-xrf-coating-weight-standards-white-paper-registration-form.html?icid=CAD_blog_metals_202Juily\">Challenges Associated with Developing XRF Coating Weight Standards<\/a><\/em> that includes a review of XRF coating weight gauges, the measuring principles behind the systems, calibration methods, and more.<\/p>\n<p><em>References<\/em><\/p>\n<p><span style=\"font-size: 8pt\"><sup>1<\/sup>M Deka, \u201cProcedure for Generating Calibration Standards for Galvanized and Galvanneal Product\u201d, Proceedings of the Galvanizers Association, 1995.<\/span><\/p>\n<p><span style=\"font-size: 8pt\"><sup>2<\/sup>J W Leeker, D Kleimeyer, G S Burgess, \u201cCalibration Program \u2013 Coating Weight Standards for On-line Gages\u201d, Proceedings of the Galvanizers Association, 1992.<\/span><\/p>\n<p><em>Additional Resources:<\/em><\/p>\n<ul>\n<li>Download our free <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/steel-manufacturing-ebook-registration-form.html?icid=CAD_blog_metals_2023\">eBook: A Practical Guide to Improving Steel Manufacturing Processes and Production Methods<\/a><\/li>\n<li><em>Visit our center for <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/steel-manufacturing.html?icid=CAD_blog_metals_bottomsteelresourcelink\">Improving Steel Manufacturing Processes and Production<\/a><\/em><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Galvanized (GI) steel is flat sheet steel which has been coated in a layer of zinc to help the metal resist corrosion. The US General Services Administration notes that galvanized sheet steel is typically used for flashing, gutters and downspouts, as well as for hot-dipped galvanized steel nails, roof and wall ornaments, and other building<\/p>\n","protected":false},"author":71,"featured_media":11490,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[3,105,206],"tags":[129,211,26],"division":[],"class_list":{"0":"post-11444","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-manufacturing-quality-assurance","8":"category-metals-measurement","9":"category-steel","10":"tag-galvanized-steel","11":"tag-metal-coating","12":"tag-steel","13":"entry"},"_selected_authors":[807],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>An Ideal Galvanized Steel Sample Collection Process - Analyzing Metals<\/title>\n<meta name=\"description\" content=\"Discover best practices for galvanized steel sample collection to improve coating analysis, ensure accurate results, and support consistent quality control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"An Ideal Galvanized Steel Sample Collection Process\" \/>\n<meta property=\"og:description\" content=\"Discover best practices for galvanized steel sample collection to improve coating analysis, ensure accurate results, and support consistent quality control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2021-07-27T12:00:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-28T20:29:40+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"748\" \/>\n\t<meta property=\"og:image:height\" content=\"467\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chris Burnett\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chris Burnett\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/\"},\"author\":{\"name\":\"Chris Burnett\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/280309c7805555140a8672b9fbffea86\"},\"headline\":\"An Ideal Galvanized Steel Sample Collection Process\",\"datePublished\":\"2021-07-27T12:00:16+00:00\",\"dateModified\":\"2026-07-28T20:29:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/\"},\"wordCount\":544,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2021\\\/07\\\/istock-1179402036_galvanizezincbath.jpg\",\"keywords\":[\"galvanized steel\",\"metal coating\",\"steel\"],\"articleSection\":[\"Manufacturing Quality Assurance\",\"Metals Measurement\",\"Steel\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/\",\"name\":\"An Ideal Galvanized Steel Sample Collection Process - Analyzing Metals\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2021\\\/07\\\/istock-1179402036_galvanizezincbath.jpg\",\"datePublished\":\"2021-07-27T12:00:16+00:00\",\"dateModified\":\"2026-07-28T20:29:40+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/280309c7805555140a8672b9fbffea86\"},\"description\":\"Discover best practices for galvanized steel sample collection to improve coating analysis, ensure accurate results, and support consistent quality control.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2021\\\/07\\\/istock-1179402036_galvanizezincbath.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2021\\\/07\\\/istock-1179402036_galvanizezincbath.jpg\",\"width\":748,\"height\":467,\"caption\":\"Metallic pieces galvanized on zinc bath\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/an-ideal-galvanized-steel-sample-collection-process\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"An Ideal Galvanized Steel Sample Collection Process\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/280309c7805555140a8672b9fbffea86\",\"name\":\"Chris Burnett\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/70df68b242286899f69cef2802dd26420a55cd8990310d09f615f77bcbe01064?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/70df68b242286899f69cef2802dd26420a55cd8990310d09f615f77bcbe01064?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/70df68b242286899f69cef2802dd26420a55cd8990310d09f615f77bcbe01064?s=96&d=mm&r=g\",\"caption\":\"Chris Burnett\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/chrisburnett\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"An Ideal Galvanized Steel Sample Collection Process - Analyzing Metals","description":"Discover best practices for galvanized steel sample collection to improve coating analysis, ensure accurate results, and support consistent quality control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/","og_locale":"en_US","og_type":"article","og_title":"An Ideal Galvanized Steel Sample Collection Process","og_description":"Discover best practices for galvanized steel sample collection to improve coating analysis, ensure accurate results, and support consistent quality control.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2021-07-27T12:00:16+00:00","article_modified_time":"2026-07-28T20:29:40+00:00","og_image":[{"width":748,"height":467,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg","type":"image\/jpeg"}],"author":"Chris Burnett","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Chris Burnett","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/"},"author":{"name":"Chris Burnett","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/280309c7805555140a8672b9fbffea86"},"headline":"An Ideal Galvanized Steel Sample Collection Process","datePublished":"2021-07-27T12:00:16+00:00","dateModified":"2026-07-28T20:29:40+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/"},"wordCount":544,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg","keywords":["galvanized steel","metal coating","steel"],"articleSection":["Manufacturing Quality Assurance","Metals Measurement","Steel"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/","name":"An Ideal Galvanized Steel Sample Collection Process - Analyzing Metals","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg","datePublished":"2021-07-27T12:00:16+00:00","dateModified":"2026-07-28T20:29:40+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/280309c7805555140a8672b9fbffea86"},"description":"Discover best practices for galvanized steel sample collection to improve coating analysis, ensure accurate results, and support consistent quality control.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg","width":748,"height":467,"caption":"Metallic pieces galvanized on zinc bath"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/an-ideal-galvanized-steel-sample-collection-process\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"An Ideal Galvanized Steel Sample Collection Process"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/280309c7805555140a8672b9fbffea86","name":"Chris Burnett","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/70df68b242286899f69cef2802dd26420a55cd8990310d09f615f77bcbe01064?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/70df68b242286899f69cef2802dd26420a55cd8990310d09f615f77bcbe01064?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/70df68b242286899f69cef2802dd26420a55cd8990310d09f615f77bcbe01064?s=96&d=mm&r=g","caption":"Chris Burnett"},"url":"https:\/\/admin.acceleratingscience.com\/author\/chrisburnett\/"}]}},"taxonomy_info":{"category":[{"value":3,"label":"Manufacturing Quality Assurance"},{"value":105,"label":"Metals Measurement"},{"value":206,"label":"Steel"}],"post_tag":[{"value":129,"label":"galvanized steel"},{"value":211,"label":"metal coating"},{"value":26,"label":"steel"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg",748,467,false],"author_info":{"display_name":"Chris Burnett","author_link":"https:\/\/admin.acceleratingscience.com\/author\/chrisburnett\/"},"comment_info":1,"category_info":[{"term_id":3,"name":"Manufacturing Quality Assurance","slug":"manufacturing-quality-assurance","term_group":0,"term_taxonomy_id":3,"taxonomy":"category","description":"","parent":0,"count":155,"filter":"raw","meta":[],"cat_ID":3,"category_count":155,"category_description":"","cat_name":"Manufacturing Quality Assurance","category_nicename":"manufacturing-quality-assurance","category_parent":0},{"term_id":105,"name":"Metals Measurement","slug":"metals-measurement","term_group":0,"term_taxonomy_id":105,"taxonomy":"category","description":"","parent":0,"count":20,"filter":"raw","meta":[],"cat_ID":105,"category_count":20,"category_description":"","cat_name":"Metals Measurement","category_nicename":"metals-measurement","category_parent":0},{"term_id":206,"name":"Steel","slug":"steel","term_group":0,"term_taxonomy_id":206,"taxonomy":"category","description":"steel manufacturing","parent":0,"count":187,"filter":"raw","meta":[],"cat_ID":206,"category_count":187,"category_description":"steel manufacturing","cat_name":"Steel","category_nicename":"steel","category_parent":0}],"tag_info":[{"term_id":129,"name":"galvanized steel","slug":"galvanized-steel","term_group":0,"term_taxonomy_id":129,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":211,"name":"metal coating","slug":"metal-coating","term_group":0,"term_taxonomy_id":211,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":26,"name":"steel","slug":"steel","term_group":0,"term_taxonomy_id":26,"taxonomy":"post_tag","description":"","parent":0,"count":67,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":13557,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-improve-inspection-of-small-metal-parts\/","url_meta":{"origin":11444,"position":0},"title":"How to Improve Inspection of Small Metal Parts","author":"Marlene Gasdia-Cochrane","date":"May 26, 2026","format":false,"excerpt":"Article Summary Manufacturers, quality control teams, and field inspectors face a growing challenge when verifying the composition of small metal parts. Components such as fasteners, weld wire, tubing, bolts, and machined pieces are often difficult to analyze accurately. These parts are critical to operational safety and product integrity, yet their\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"small metal fasteners","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1733,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/heres-a-free-periodic-table-for-your-halloween-goody-bag\/","url_meta":{"origin":11444,"position":1},"title":"Here&#8217;s a Free Periodic Table for Your Halloween Goody-Bag","author":"Marlene Gasdia-Cochrane, Editor","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your metals samples. \u00a0It's our treat. Then visit our Steel Manufacturing and Precious Metals Analysis\u00a0 pages for more goodies. Download Periodic Table.\u00a0","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Halloween pumpkin with goodies","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":11444,"position":2},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":11444,"position":3},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":10286,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/a-valentines-special-best-metal-elements-for-a-sturdy-piece-of-jewelry\/","url_meta":{"origin":11444,"position":4},"title":"A Valentine\u2019s Special: Best Metal Elements for a Sturdy Piece of Jewelry","author":"Mark Lessard","date":"February 10, 2026","format":false,"excerpt":"A Pleasant Garden article noted that \"from a global perspective, nearly 6 million couples get engaged on February 14th.\"\u00a0It\u2019s no surprise that many of those who \u2018pop the question\u2019 choose to do it on the day known for its message of love and affection. Those who have bought an engagement\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"ring in box with Valentine heart decorations","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":12889,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/diwali-sparks-gold-buying-frenzy\/","url_meta":{"origin":11444,"position":5},"title":"Diwali Sparks Gold-Buying Frenzy","author":"Marlene Gasdia-Cochrane","date":"October 28, 2025","format":false,"excerpt":"Forty tons of gold, worth $11 billion, was purchased by India in the first two days of Diwali. About 8,000 miles away in New York City, there was a gold buying rush and a cash-for-gold frenzy. Buyers and sellers are banking on the hope that the gold in the pieces\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Diwali Puja Thali With Flowers, Diya, And Gifts","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2021\/07\/istock-1179402036_galvanizezincbath.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/11444","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/71"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=11444"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/11444\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/11490"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=11444"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=11444"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=11444"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=11444"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}