{"id":12429,"date":"2023-12-05T08:00:26","date_gmt":"2023-12-05T08:00:26","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/metals\/?p=12429"},"modified":"2026-02-03T20:46:23","modified_gmt":"2026-02-03T20:46:23","slug":"reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/","title":{"rendered":"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry"},"content":{"rendered":"<p><span data-contrast=\"none\">Every measurement comes with uncertainty. If you\u2019re measuring with a ruler that is only marked to the millimeter, or a with balance using only one-gram standard weights, there is going to be some point at which that measurement becomes inexact. You can get pretty close to exact, but the question is, how close? How certain can you be that your measurement is correct? This calculation of the uncertainty in measurement is where reference materials play a key role, especially in a field as specific as spark spectrometry.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/optical-emission-spectrometry\/instruments.html?icid=CAD_blog_metals_2023Dec\">Spark spectrometers<\/a> <span data-contrast=\"none\">(also referred to as spark emission spectrometers or spark OES) analyze metallic samples through the application of an electric arc or spark, causing analytes to emit light and thereby reveal their presence and concentration via distinctive wavelength signatures. Spark spectrometers are relatively easy to use and maintain, and they provide the fastest determination of present elements with high accuracy and precision. But <\/span><i><span data-contrast=\"none\">how<\/span><\/i><span data-contrast=\"none\"> accurate and precise they are, is a question that needs to be answered, for each and every measurement performed.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">With <\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/optical-emission-spectrometry.html?icid=CAD_blog_metals_2023Dec\">spark spectrometry of metals<\/a><span data-contrast=\"none\">\u00a0knowledge of the level of uncertainty in measurement is hugely important, and is necessary to properly validate measurement results. According to DIN EN ISO 17025,<\/span> <span data-contrast=\"none\">the worldwide standard for laboratory accreditation in the area of testing and calibration, it is necessary to calculate the measurement uncertainty for each measurement result.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<h2><span data-contrast=\"none\">Uncertainty in measurement for reference materials<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"none\">Uncertainty is generally defined as a range of values centered on the measurement value, and it includes an asserted true value with the stated probability. [To put it in more technical terms, according to the Guide to the Expression of Uncertainty in Measurement (GUM) and the International Vocabulary of Metrology (VIM), the uncertainty of measurement is a measure of the dispersion of values that can reasonably be attributed to a measurement result. The parameter of uncertainty is specifically associated with the result of a measurement.]\u00a0<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<p><span data-contrast=\"none\">Like most analytical instrumentation, spark spectrometry is comparative, meaning that it requires a sample of a known composition for accurate calibration. These known samples are called reference materials, and measurements of unknown samples can be compared to them. Uncertainty in measurement for reference materials needs to be accounted for and applied to measurements of unknowns. For this reason, it is important to understand what type of reference materials might be in use for any given experiment.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<h2><span data-contrast=\"none\">Spark spectrometry reference materials<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/h2>\n<p><span data-contrast=\"none\">Four types of reference materials can be used for spark spectrometry: Setting Up samples, reference materials (RMs), Certified reference materials (CRMs), and Traceable CRMs.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"1\" data-aria-level=\"1\"><span data-contrast=\"none\">Setting Up Samples are homogeneous but do not have certified exact concentration values. These samples can be used for control cards, instrument recalibration, or homogeneity testing. Setting up samples, such as RE12, do not have assigned concentration values for all elements in the certificate and do not provide information about measurement uncertainties. These samples cannot be used for calculating measurement uncertainties.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"2\" data-aria-level=\"1\"><span data-contrast=\"none\">Reference materials (RMs) is often the term used for a group of either pure substances or matrix materials which are used for calibration, method validation, method development, and for various quality control purposes. RMs have assigned concentration values and information about the uncertainty of each element. RM certificates also list the specific use of the sample in each laboratory and the names of the participants in the characterization study.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"3\" data-aria-level=\"1\"><span data-contrast=\"none\">Certified reference materials (CRMs) are produced according to relevant standards and have their concentrations calculated through a round-robin test. A CRM fulfils numerous requirements including proven homogeneity and stability. CRMs provide average concentration values and the uncertainty of each element, as well as information about the method of preparation, sampling, chemical analysis, estimation of uncertainties, and traceability. CRM certificates also describe the details of production and certification according to relevant standards (such as ISO Guide 31, 35 and ISO 17034) and the Guide to the Expression of Uncertainty in Measurement (GUM) requirements.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<ul>\n<li data-leveltext=\"\uf0b7\" data-font=\"Symbol\" data-listid=\"1\" data-list-defn-props=\"{&quot;335552541&quot;:1,&quot;335559684&quot;:-2,&quot;335559685&quot;:720,&quot;335559991&quot;:360,&quot;469769226&quot;:&quot;Symbol&quot;,&quot;469769242&quot;:[8226],&quot;469777803&quot;:&quot;left&quot;,&quot;469777804&quot;:&quot;\uf0b7&quot;,&quot;469777815&quot;:&quot;hybridMultilevel&quot;}\" data-aria-posinset=\"4\" data-aria-level=\"1\"><span data-contrast=\"none\">Traceable CRMs are the highest quality reference materials, produced by national institutes such as PTB and BAM in Germany or NIST in the USA. The competence of CRM producers can also be proven by accreditation according to ISO 17034.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/li>\n<\/ul>\n<p><span data-contrast=\"none\">Regardless of the system operator or the sample preparation method, or what your exact <\/span><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/optical-emission-spectrometry\/applications.html\">application of spark OES<\/a><span data-contrast=\"none\"> spectrometry may be <\/span><span data-contrast=\"none\">having the right reference materials for the job is essential to calculate the measurement uncertainty for each result and keep compliant with laboratory accreditation standards.<\/span><span data-ccp-props=\"{&quot;201341983&quot;:0,&quot;335559740&quot;:259}\">\u00a0<\/span><\/p>\n<h2>Additional Resources<\/h2>\n<ul>\n<li>\n<p role=\"heading\" data-uw-rm-heading=\"level\">On-Demand Webinar:\u00a0<a href=\"https:\/\/www.thermofisher.com\/ch\/en\/home\/global\/forms\/industrial\/oes-uncertainty-of-measurement.html?icid=CAD_blog_metals_2023Dec\"><em>Laboratory measurement uncertainty using optical emission spectroscopy<\/em><\/a><\/p>\n<\/li>\n<li>\n<p role=\"heading\" data-uw-rm-heading=\"level\"><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/oes-xrd-xrf-analysis\/optical-emission-spectrometry\/instruments.html?icid=CAD_blog_metals_2023Dec\">Optical Emission Spectrometers<\/a><\/p>\n<\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAHGABDFAOOMBOF%20?icid=CAD_blog_metals_2023Dec\">ARL iSpark Plus Series OES Metal Analyzer\u00a0<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Every measurement comes with uncertainty. If you\u2019re measuring with a ruler that is only marked to the millimeter, or a with balance using only one-gram standard weights, there is going to be some point at which that measurement becomes inexact. You can get pretty close to exact, but the question is, how close? How certain<\/p>\n","protected":false},"author":1730,"featured_media":12430,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[3,7,4],"tags":[248,249,37,32,247,250],"division":[],"class_list":{"0":"post-12429","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-manufacturing-quality-assurance","8":"category-metals-and-alloys","9":"category-positive-material-identification","10":"tag-certified-reference-materials","11":"tag-measurement","12":"tag-metal-analysis","13":"tag-optical-emission-spectrometry","14":"tag-spark-spectrometry","15":"tag-uncertainty-in-measurement","16":"entry"},"_selected_authors":[784],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry - Analyzing Metals<\/title>\n<meta name=\"description\" content=\"Learn why reference materials play a key role in the calculation of uncertainty in measurement, especially in spark spectrometry.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry\" \/>\n<meta property=\"og:description\" content=\"Learn why reference materials play a key role in the calculation of uncertainty in measurement, especially in spark spectrometry.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-05T08:00:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-03T20:46:23+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"717\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Wilhelm Sanders\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Wilhelm Sanders\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/\"},\"author\":{\"name\":\"Wilhelm Sanders\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/424569b20b39c9dc3be873691c5930fd\"},\"headline\":\"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry\",\"datePublished\":\"2023-12-05T08:00:26+00:00\",\"dateModified\":\"2026-02-03T20:46:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/\"},\"wordCount\":757,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/12\\\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg\",\"keywords\":[\"certified reference materials\",\"measurement\",\"metal analysis\",\"optical emission spectrometry\",\"spark spectrometry\",\"uncertainty in measurement\"],\"articleSection\":[\"Manufacturing Quality Assurance\",\"Metals &amp; Alloys\",\"Positive Material Identification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/\",\"name\":\"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry - Analyzing Metals\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/12\\\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg\",\"datePublished\":\"2023-12-05T08:00:26+00:00\",\"dateModified\":\"2026-02-03T20:46:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/424569b20b39c9dc3be873691c5930fd\"},\"description\":\"Learn why reference materials play a key role in the calculation of uncertainty in measurement, especially in spark spectrometry.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/12\\\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2023\\\/12\\\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg\",\"width\":1024,\"height\":717,\"caption\":\"diagram of car chassis made of metal\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/424569b20b39c9dc3be873691c5930fd\",\"name\":\"Wilhelm Sanders\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/17285680c18d1a0bd99513bd14d0f88fdea3fafc0d4549677eb7dc3618fa6fc1?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/17285680c18d1a0bd99513bd14d0f88fdea3fafc0d4549677eb7dc3618fa6fc1?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/17285680c18d1a0bd99513bd14d0f88fdea3fafc0d4549677eb7dc3618fa6fc1?s=96&d=mm&r=g\",\"caption\":\"Wilhelm Sanders\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/wilhelmsanders\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry - Analyzing Metals","description":"Learn why reference materials play a key role in the calculation of uncertainty in measurement, especially in spark spectrometry.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/","og_locale":"en_US","og_type":"article","og_title":"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry","og_description":"Learn why reference materials play a key role in the calculation of uncertainty in measurement, especially in spark spectrometry.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2023-12-05T08:00:26+00:00","article_modified_time":"2026-02-03T20:46:23+00:00","og_image":[{"width":1024,"height":717,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg","type":"image\/jpeg"}],"author":"Wilhelm Sanders","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Wilhelm Sanders","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/"},"author":{"name":"Wilhelm Sanders","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/424569b20b39c9dc3be873691c5930fd"},"headline":"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry","datePublished":"2023-12-05T08:00:26+00:00","dateModified":"2026-02-03T20:46:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/"},"wordCount":757,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg","keywords":["certified reference materials","measurement","metal analysis","optical emission spectrometry","spark spectrometry","uncertainty in measurement"],"articleSection":["Manufacturing Quality Assurance","Metals &amp; Alloys","Positive Material Identification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/","name":"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry - Analyzing Metals","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg","datePublished":"2023-12-05T08:00:26+00:00","dateModified":"2026-02-03T20:46:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/424569b20b39c9dc3be873691c5930fd"},"description":"Learn why reference materials play a key role in the calculation of uncertainty in measurement, especially in spark spectrometry.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg","width":1024,"height":717,"caption":"diagram of car chassis made of metal"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/reference-materials-are-essential-to-determine-uncertainty-in-measurement-for-spark-spectrometry\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"Reference Materials Are Essential to Determine Uncertainty in Measurement for Spark Spectrometry"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/424569b20b39c9dc3be873691c5930fd","name":"Wilhelm Sanders","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/17285680c18d1a0bd99513bd14d0f88fdea3fafc0d4549677eb7dc3618fa6fc1?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/17285680c18d1a0bd99513bd14d0f88fdea3fafc0d4549677eb7dc3618fa6fc1?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/17285680c18d1a0bd99513bd14d0f88fdea3fafc0d4549677eb7dc3618fa6fc1?s=96&d=mm&r=g","caption":"Wilhelm Sanders"},"url":"https:\/\/admin.acceleratingscience.com\/author\/wilhelmsanders\/"}]}},"taxonomy_info":{"category":[{"value":3,"label":"Manufacturing Quality Assurance"},{"value":7,"label":"Metals &amp; Alloys"},{"value":4,"label":"Positive Material Identification"}],"post_tag":[{"value":248,"label":"certified reference materials"},{"value":249,"label":"measurement"},{"value":37,"label":"metal analysis"},{"value":32,"label":"optical emission spectrometry"},{"value":247,"label":"spark spectrometry"},{"value":250,"label":"uncertainty in measurement"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg",760,532,false],"author_info":{"display_name":"Wilhelm Sanders","author_link":"https:\/\/admin.acceleratingscience.com\/author\/wilhelmsanders\/"},"comment_info":2,"category_info":[{"term_id":3,"name":"Manufacturing Quality Assurance","slug":"manufacturing-quality-assurance","term_group":0,"term_taxonomy_id":3,"taxonomy":"category","description":"","parent":0,"count":155,"filter":"raw","meta":[],"cat_ID":3,"category_count":155,"category_description":"","cat_name":"Manufacturing Quality Assurance","category_nicename":"manufacturing-quality-assurance","category_parent":0},{"term_id":7,"name":"Metals &amp; Alloys","slug":"metals-and-alloys","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":224,"filter":"raw","meta":[],"cat_ID":7,"category_count":224,"category_description":"","cat_name":"Metals &amp; Alloys","category_nicename":"metals-and-alloys","category_parent":0},{"term_id":4,"name":"Positive Material Identification","slug":"positive-material-identification","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":123,"filter":"raw","meta":[],"cat_ID":4,"category_count":123,"category_description":"","cat_name":"Positive Material Identification","category_nicename":"positive-material-identification","category_parent":0}],"tag_info":[{"term_id":248,"name":"certified reference materials","slug":"certified-reference-materials","term_group":0,"term_taxonomy_id":248,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":249,"name":"measurement","slug":"measurement","term_group":0,"term_taxonomy_id":249,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":37,"name":"metal analysis","slug":"metal-analysis","term_group":0,"term_taxonomy_id":37,"taxonomy":"post_tag","description":"","parent":0,"count":83,"filter":"raw","meta":[]},{"term_id":32,"name":"optical emission spectrometry","slug":"optical-emission-spectrometry","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":247,"name":"spark spectrometry","slug":"spark-spectrometry","term_group":0,"term_taxonomy_id":247,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":250,"name":"uncertainty in measurement","slug":"uncertainty-in-measurement","term_group":0,"term_taxonomy_id":250,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/12\/unibody-car-chassis.jpg_s1024x1024wisk20c98YHcwoj3-LcgCF3Chr53PG-ugV2tSzKCS1ujb4e8fc.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/12429","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/1730"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=12429"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/12429\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/12430"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=12429"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=12429"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=12429"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=12429"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}