{"id":2291,"date":"2023-02-28T08:00:03","date_gmt":"2023-02-28T08:00:03","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=2291"},"modified":"2026-03-03T16:42:30","modified_gmt":"2026-03-03T16:42:30","slug":"platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/","title":{"rendered":"Are There Precious Metals in Catalytic Converters?"},"content":{"rendered":"<p><strong>Scrap Metal Recyclers use XRF analysis to help recover valuable platinum group metals from spent catalytic converters\u00a0<\/strong><\/p>\n<p>A catalytic converter is a device used to convert <a href=\"https:\/\/www.epa.gov\/transportation-air-pollution-and-climate-change\/overview-air-pollution-transportation\">toxic vehicle emissions<\/a> to less harmful substances by way of catalyzed, or accelerated, chemical reactions. Most present-day vehicles that run on gasoline, including automobiles, trucks, buses, trains, motorcycles, and planes, have exhaust systems employing a catalytic converter.<\/p>\n<p>The catalyst component of a catalytic converter is usually platinum (Pt), along with palladium (Pd), and rhodium (Rh). All three of these platinum group metals, or PGMs, are extremely rare but have a broad range of applications in addition to catalytic converters. Platinum, for example, is used in laboratory and dental equipment, electrical contacts and electrodes, and jewelry, while palladium plays a key role in fuel cell technology. With numerous applications and limited supply, these valuable metals are an attractive target by scrap metal recycling facilities for recovery and reuse from spent catalytic converters.<\/p>\n<p>In 2020, the demand for Pt, Pd, and Rh totaled respectively 215, 308, and 31.2 tons. About 32% of the total Pt, 85% of the total Pd, and 90% of the total Rh were consumed by the automotive catalyst industry(1) . The same year 33.7 tons of Pt, 41.2 tons of Pd, and 7.3 tons of Rh(1) were recovered from <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/portable-scrap-metal-recycling-analysis.html?icid=CAD_blog_metals_2023Feb\" target=\"_blank\" rel=\"noopener\">scrap recycling<\/a> activities, mainly from spent catalytic converters, representing at the 2020 cumulative average price of fine metals a total value of about $12 Billion.<\/p>\n<h2>Finding The Value of Catalytic Converter PGMs<\/h2>\n<p>Determining the recovery value of the PGMs in a catalytic converter begins with knowing the composition and ratios of the metals used.\u00a0 Automotive catalyst material is made either of a ceramic substrate, mostly cordierite coated with a precious metal containing a wash coat, or of a metallic substrate with an aluminum oxide wash coat also containing precious metals.\u00a0 The average concentration and the ratio of Pt and Rh were more or less constant 20 years ago, so a simple weighting was sufficient to arrive at a good estimation of the precious metal content. However, the price of these three elements has fluctuated strongly over the last 20 years, depending on the supply, demand, and speculation. These variations, as well as the tightening of emission legislation, have had a direct correlation on the composition of the catalysts, which themselves have had a strong influence on demand.<\/p>\n<p>Currently, the composition, which depends on the engine displacement and the type of fuel used, varies dramatically. The formulation can consist of only Pt, or various ratios of Pt-Pd-Rh, Pt-Rh, and Pd-Rh. Most of today\u2019s recycled catalytic converters come from cars manufactured, on average, 10 to 15 years ago. The recoverable amounts of Pt, Pd, and Rh in each can range from 1-2 grams for a small car to 12-15 grams for a big truck in the US.<\/p>\n<p>The value of the PGM composition of a single catalytic converter can vary from less than $100 to more than $1000.\u00a0 Moreover, the trade of ground-up material sold as catalysts can be very dangerous because of possible alterations, which can mean inclusion of lead or spent nickel-cadmium batteries.<\/p>\n<h2>Tools to Help Analyze Catalytic Converter Material<\/h2>\n<p>To avoid considerable financial losses, recycling companies need to quickly and accurately determine the contents of Pt, Pd, and Rh in spent catalytic converters at the collector\u2019s site or in the refineries. In order to analyze non-homogeneous materials like catalytic converters, the collected catalysts with ceramic substrate usually undergo a \u201cde-canning\u201d operation, which is the extraction of the honeycomb-structured ceramic material from the steel case. All of the ceramic is then sorted crushed, milled, and mostly blended with other catalysts. In contrast, converters with a metallic substrate are first shredded or milled, and then the metallic parts are separated using magnets and winnowing from the wash coat powder containing precious metals. Because of this enrichment, the PGM content of these wash coat samples is usually much higher than that for milled ceramics. In both cases, the materials are pulverized to a maximum 250\u00b5m and loaded into sample cups or sample bags for analysis, and then analyzed using <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/spectroscopy-elemental-isotope-analysis-learning-center\/elemental-analysis-information\/xrf-technology.html?icid=CAD_blog_metals_2023Feb\" target=\"_blank\" rel=\"noopener\">x-ray fluorescence (XRF) technology<\/a><a href=\"http:\/\/www.niton.com\/en\/metal-and-alloy-analysis\/applications\/goldanalysis\">.<\/a><\/p>\n<p>XRF is a non-destructive analytical technique used to determine the elemental composition of materials. <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/NITONXL5E?icid=CAD_blog_metals_2023Feb\" target=\"_blank\" rel=\"noopener\">Handheld XRF analyzers<\/a> work by measuring the fluorescent (or secondary) X-rays emitted from a sample when excited by a primary X-ray source. Each of the elements present in a sample produces a set of characteristic fluorescent X-rays, or \u201cunique fingerprints\u201d. These \u201cfingerprints\u201d are distinct for each element, making handheld XRF analysis an excellent tool for quantitative and qualitative measurements.<\/p>\n<p>A recent study evaluated x-ray fluorescence (XRF) analysis as compared to lab assays for achieving this objective. To see the results, including the correlation curves, repeatability data, methodology, and comments, read \u00a0<a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/AutoCatalyticConverter-AppNote.pdf?icid=CAD_blog_metals_2023Feb\" target=\"_blank\" rel=\"noopener\">Automotive Catalytic Converters application summary<\/a>.<\/p>\n<h2>Additional Resources and References<\/h2>\n<ul>\n<li>Application Note: <a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/AutoCatalyticConverter-AppNote.pdf?icid=CAD_blog_metals_2023Feb\" target=\"_blank\" rel=\"noopener\">Determination of platinum, palladium, and rhodium in spent automotive catalytic converters<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/portable-scrap-metal-recycling-analysis.html?icid=CAD_blog_metals_2023Feb\" target=\"_blank\" rel=\"noopener\">Thermo Scientific scrap metal recycling technologies and instruments<\/a>.<\/li>\n<\/ul>\n<p>(1) Johnson Matthey, Pgm market report February 2021 &#8211; http:\/\/www.platinum.matthey.com\/<\/p>\n<p><em>Editor&#8217;s Note:\u00a0 This article was originally published 03.20.2014 by Stephen Dietz but has been updated and refreshed.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Scrap Metal Recyclers use XRF analysis to help recover valuable platinum group metals from spent catalytic converters\u00a0 A catalytic converter is a device used to convert toxic vehicle emissions to less harmful substances by way of catalyzed, or accelerated, chemical reactions. Most present-day vehicles that run on gasoline, including automobiles, trucks, buses, trains, motorcycles, and<\/p>\n","protected":false},"author":212,"featured_media":2290,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[7,5,6],"tags":[56,40,57,58,9,28],"division":[],"class_list":["post-2291","post","type-post","status-publish","format-standard","has-post-thumbnail","category-metals-and-alloys","category-precious-metals","category-scrap-metal-recycling","tag-catalytic-converter","tag-metal","tag-metal-recycling","tag-platinum","tag-precious-metals-2","tag-xrf","entry"],"_selected_authors":[754],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Are There Precious Metals in Catalytic Converters?<\/title>\n<meta name=\"description\" content=\"Discover how XRF analysis helps recover valuable platinum group metals from spent catalytic converters for recycling and reuse.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Are There Precious Metals in Catalytic Converters?\" \/>\n<meta property=\"og:description\" content=\"Discover how XRF analysis helps recover valuable platinum group metals from spent catalytic converters for recycling and reuse.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-28T08:00:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-03T16:42:30+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"3072\" \/>\n\t<meta property=\"og:image:height\" content=\"2048\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marlene Gasdia-Cochrane, Editor\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marlene Gasdia-Cochrane, Editor\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/\"},\"author\":{\"name\":\"Marlene Gasdia-Cochrane, Editor\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/08460e2e0ea5224ef7286295b4c76e8e\"},\"headline\":\"Are There Precious Metals in Catalytic Converters?\",\"datePublished\":\"2023-02-28T08:00:03+00:00\",\"dateModified\":\"2026-03-03T16:42:30+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/\"},\"wordCount\":841,\"commentCount\":28,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/02\\\/crw_7696.jpg\",\"keywords\":[\"catalytic converter\",\"metal\",\"metal recycling\",\"platinum\",\"precious metals\",\"xrf\"],\"articleSection\":[\"Metals &amp; Alloys\",\"Precious Metals\",\"Scrap Metal Recycling\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/\",\"name\":\"Are There Precious Metals in Catalytic Converters?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/02\\\/crw_7696.jpg\",\"datePublished\":\"2023-02-28T08:00:03+00:00\",\"dateModified\":\"2026-03-03T16:42:30+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/08460e2e0ea5224ef7286295b4c76e8e\"},\"description\":\"Discover how XRF analysis helps recover valuable platinum group metals from spent catalytic converters for recycling and reuse.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/02\\\/crw_7696.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/02\\\/crw_7696.jpg\",\"width\":3072,\"height\":2048,\"caption\":\"spent catalytic converters\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Are There Precious Metals in Catalytic Converters?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/08460e2e0ea5224ef7286295b4c76e8e\",\"name\":\"Marlene Gasdia-Cochrane, Editor\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/fa832b89b4e287e5a07e31831fe541b7e03238a5954890829f70b84ef661b66c?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/fa832b89b4e287e5a07e31831fe541b7e03238a5954890829f70b84ef661b66c?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/fa832b89b4e287e5a07e31831fe541b7e03238a5954890829f70b84ef661b66c?s=96&d=mm&r=g\",\"caption\":\"Marlene Gasdia-Cochrane, Editor\"},\"sameAs\":[\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/marlenegasdiacochrane-0\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Are There Precious Metals in Catalytic Converters?","description":"Discover how XRF analysis helps recover valuable platinum group metals from spent catalytic converters for recycling and reuse.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/","og_locale":"en_US","og_type":"article","og_title":"Are There Precious Metals in Catalytic Converters?","og_description":"Discover how XRF analysis helps recover valuable platinum group metals from spent catalytic converters for recycling and reuse.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2023-02-28T08:00:03+00:00","article_modified_time":"2026-03-03T16:42:30+00:00","og_image":[{"width":3072,"height":2048,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg","type":"image\/jpeg"}],"author":"Marlene Gasdia-Cochrane, Editor","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Marlene Gasdia-Cochrane, Editor","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/"},"author":{"name":"Marlene Gasdia-Cochrane, Editor","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/08460e2e0ea5224ef7286295b4c76e8e"},"headline":"Are There Precious Metals in Catalytic Converters?","datePublished":"2023-02-28T08:00:03+00:00","dateModified":"2026-03-03T16:42:30+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/"},"wordCount":841,"commentCount":28,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg","keywords":["catalytic converter","metal","metal recycling","platinum","precious metals","xrf"],"articleSection":["Metals &amp; Alloys","Precious Metals","Scrap Metal Recycling"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/","name":"Are There Precious Metals in Catalytic Converters?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg","datePublished":"2023-02-28T08:00:03+00:00","dateModified":"2026-03-03T16:42:30+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/08460e2e0ea5224ef7286295b4c76e8e"},"description":"Discover how XRF analysis helps recover valuable platinum group metals from spent catalytic converters for recycling and reuse.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg","width":3072,"height":2048,"caption":"spent catalytic converters"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/platinum-group-metal-recovery-from-spent-catalytic-converters-using-xrf\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"Are There Precious Metals in Catalytic Converters?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/08460e2e0ea5224ef7286295b4c76e8e","name":"Marlene Gasdia-Cochrane, Editor","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/fa832b89b4e287e5a07e31831fe541b7e03238a5954890829f70b84ef661b66c?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/fa832b89b4e287e5a07e31831fe541b7e03238a5954890829f70b84ef661b66c?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/fa832b89b4e287e5a07e31831fe541b7e03238a5954890829f70b84ef661b66c?s=96&d=mm&r=g","caption":"Marlene Gasdia-Cochrane, Editor"},"sameAs":["https:\/\/admin.acceleratingscience.com\/metals"],"url":"https:\/\/admin.acceleratingscience.com\/author\/marlenegasdiacochrane-0\/"}]}},"taxonomy_info":{"category":[{"value":7,"label":"Metals &amp; Alloys"},{"value":5,"label":"Precious Metals"},{"value":6,"label":"Scrap Metal Recycling"}],"post_tag":[{"value":56,"label":"catalytic converter"},{"value":40,"label":"metal"},{"value":57,"label":"metal recycling"},{"value":58,"label":"platinum"},{"value":9,"label":"precious metals"},{"value":28,"label":"xrf"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696-1024x683.jpg",760,507,true],"author_info":{"display_name":"Marlene Gasdia-Cochrane, Editor","author_link":"https:\/\/admin.acceleratingscience.com\/author\/marlenegasdiacochrane-0\/"},"comment_info":32,"category_info":[{"term_id":7,"name":"Metals &amp; Alloys","slug":"metals-and-alloys","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":225,"filter":"raw","meta":[],"cat_ID":7,"category_count":225,"category_description":"","cat_name":"Metals &amp; Alloys","category_nicename":"metals-and-alloys","category_parent":0},{"term_id":5,"name":"Precious Metals","slug":"precious-metals","term_group":0,"term_taxonomy_id":5,"taxonomy":"category","description":"","parent":0,"count":111,"filter":"raw","meta":[],"cat_ID":5,"category_count":111,"category_description":"","cat_name":"Precious Metals","category_nicename":"precious-metals","category_parent":0},{"term_id":6,"name":"Scrap Metal Recycling","slug":"scrap-metal-recycling","term_group":0,"term_taxonomy_id":6,"taxonomy":"category","description":"","parent":0,"count":92,"filter":"raw","meta":[],"cat_ID":6,"category_count":92,"category_description":"","cat_name":"Scrap Metal Recycling","category_nicename":"scrap-metal-recycling","category_parent":0}],"tag_info":[{"term_id":56,"name":"catalytic converter","slug":"catalytic-converter","term_group":0,"term_taxonomy_id":56,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]},{"term_id":40,"name":"metal","slug":"metal","term_group":0,"term_taxonomy_id":40,"taxonomy":"post_tag","description":"","parent":0,"count":47,"filter":"raw","meta":[]},{"term_id":57,"name":"metal recycling","slug":"metal-recycling","term_group":0,"term_taxonomy_id":57,"taxonomy":"post_tag","description":"","parent":0,"count":9,"filter":"raw","meta":[]},{"term_id":58,"name":"platinum","slug":"platinum","term_group":0,"term_taxonomy_id":58,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw","meta":[]},{"term_id":9,"name":"precious metals","slug":"precious-metals-2","term_group":0,"term_taxonomy_id":9,"taxonomy":"post_tag","description":"","parent":0,"count":33,"filter":"raw","meta":[]},{"term_id":28,"name":"xrf","slug":"xrf","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":32,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":10286,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/a-valentines-special-best-metal-elements-for-a-sturdy-piece-of-jewelry\/","url_meta":{"origin":2291,"position":0},"title":"A Valentine\u2019s Special: Best Metal Elements for a Sturdy Piece of Jewelry","author":"Mark Lessard","date":"February 10, 2026","format":false,"excerpt":"A Pleasant Garden article noted that \"from a global perspective, nearly 6 million couples get engaged on February 14th.\"\u00a0It\u2019s no surprise that many of those who \u2018pop the question\u2019 choose to do it on the day known for its message of love and affection. Those who have bought an engagement\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"ring in box with Valentine heart decorations","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":13568,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-handheld-xrf-technology-exposed-counterfeit-silver-coins-sold-online\/","url_meta":{"origin":2291,"position":1},"title":"How Handheld XRF Technology Exposed Counterfeit Silver Coins Sold Online","author":"Marlene Gasdia-Cochrane","date":"May 28, 2026","format":false,"excerpt":"Summary Counterfeit silver coins are becoming a growing problem in online marketplaces, putting coin collectors, precious metal investors, pawn shops, and bullion buyers at financial risk. A recent \u00a0NBC Connecticut investigation uncovered fake American Eagle silver bullion coins being sold online at prices far below market value. Although the coins\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Silver coins and silver bullion","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13584,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/why-fall-jewelry-trade-shows-matter-for-holiday-inventory-planning\/","url_meta":{"origin":2291,"position":2},"title":"Why Fall Jewelry Trade Shows Matter for Holiday Inventory Planning","author":"Marlene Gasdia-Cochrane","date":"October 13, 2026","format":false,"excerpt":"Introduction Fall is a critical inventory-planning period for jewelry retailers, wholesalers, designers, and professional buyers. A major trade-only jewelry event taking place October 16\u201319, 2026, in Miami Beach, Florida, is JIS Fall, which gives industry professionals an opportunity to replenish inventory, discover jewelry trends, explore gold analysis technology, and connect\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Golden chain hanging on a black frame with bokeh lights and expo blur, matching VIP access, premium presentation, and business event concepts","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-2265657012_goldshow.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-2265657012_goldshow.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-2265657012_goldshow.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-2265657012_goldshow.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-2265657012_goldshow.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-2265657012_goldshow.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13857,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/eight-reasons-jewelers-should-not-use-acid-to-test-jewelry\/","url_meta":{"origin":2291,"position":3},"title":"Eight Reasons Jewelers Should NOT Use Acid to Test Jewelry","author":"Marlene Gasdia-Cochrane","date":"October 16, 2026","format":false,"excerpt":"Introduction Traditional acid testing can provide a useful initial indication of precious metal purity, but authoritative sources recognize its limitations when more precise analysis is needed. The Convention on the Control and Marking of Articles of Precious Metals describes touch acid testing as providing a \u201cgood early indication of fineness\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Jeweller's workshop","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":2291,"position":4},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":2291,"position":5},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/02\/crw_7696.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/2291","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/212"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=2291"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/2291\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/2290"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=2291"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=2291"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=2291"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=2291"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}