{"id":2646,"date":"2014-06-05T08:30:17","date_gmt":"2014-06-05T12:30:17","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=2646"},"modified":"2026-02-05T20:05:14","modified_gmt":"2026-02-05T20:05:14","slug":"video-oes-provides-reliable-metal-analysis-for-contract-laboratory","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/","title":{"rendered":"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory"},"content":{"rendered":"<p><a href=\"http:\/\/www.degerforslab.se\/en\/\" target=\"_blank\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" style=\"float: right;border: 0;margin: 10px\" title=\"D-Lab VideoImage\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2014\/05\/dlabvideo.jpg\" alt=\"D-Lab VideoImage\" width=\"315\" height=\"176\" \/>Degerfors Laboratory (D-Lab) <\/a>in Degerfors, Sweden, is an independent contract laboratory specializing in elemental analysis of metals, raw materials and minerals.\u00a0 As a contract laboratory, D-Lab needs high-accuracy and performance, very flexible and long term stable instruments for metal analysis.<\/p>\n<p><a href=\"http:\/\/www.thermoscientific.com\/en\/products\/optical-emission-spectrometry.html\" target=\"_blank\">Optical Emission Spectrometry<\/a> (OES) instruments are the overwhelming choice for steel and non-ferrous metals. These instruments provide fast, on-line elemental analysis with quantitative determination of most of the elements from trace to percentage levels.\u00a0 With OES spectrometers, companies like D-Lab can be confident that they are providing their customers with most reliable analytical results.<\/p>\n<p>We visited with Mr. Svenerik B\u00e4ckman, General Lab Manager at D-Lab to ask him about the results of various evaluations of an <a href=\"http:\/\/www.thermoscientific.com\/ecomm\/servlet\/newsdetail_11152_56658_-1\">OES spectrometer<\/a> the company performed over a 3 month period, from October 2012 to January 2013. To hear his conclusions, watch the full <a href=\"http:\/\/www.thermoscientific.com\/en\/about-us\/videos\/thermo-scientific-arl-ispark-series-related-videos.html\" target=\"_blank\">D-Lab Customer Testimonial<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Degerfors Laboratory (D-Lab) in Degerfors, Sweden, is an independent contract laboratory specializing in elemental analysis of metals, raw materials and minerals.\u00a0 As a contract laboratory, D-Lab needs high-accuracy and performance, very flexible and long term stable instruments for metal analysis. Optical Emission Spectrometry (OES) instruments are the overwhelming choice for steel and non-ferrous metals. These<\/p>\n","protected":false},"author":53,"featured_media":2645,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[7,4],"tags":[157,158,62,8,32,26,27],"division":[],"class_list":{"0":"post-2646","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-metals-and-alloys","8":"category-positive-material-identification","9":"tag-control-labs","10":"tag-degerfors-laboratory","11":"tag-elemental-analysis-2","12":"tag-metals-2","13":"tag-optical-emission-spectrometry","14":"tag-steel","15":"tag-x-ray-fluorescence","16":"entry"},"_selected_authors":[1336],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>VIDEO: OES Provides Reliable Metal Analysis for Contract Lab<\/title>\n<meta name=\"description\" content=\"See elemental analysis of metals, raw materials and minerals using Optical Emission Spectrometry (OES) instruments\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory\" \/>\n<meta property=\"og:description\" content=\"See elemental analysis of metals, raw materials and minerals using Optical Emission Spectrometry (OES) instruments\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2014-06-05T12:30:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-05T20:05:14+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"478\" \/>\n\t<meta property=\"og:image:height\" content=\"266\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Eric Hovsepian\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Eric Hovsepian\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/\"},\"author\":{\"name\":\"Eric Hovsepian\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/f162a5bd108ec475cfa794c96b2757df\"},\"headline\":\"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory\",\"datePublished\":\"2014-06-05T12:30:17+00:00\",\"dateModified\":\"2026-02-05T20:05:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/\"},\"wordCount\":149,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/05\\\/dlabvideo.jpg\",\"keywords\":[\"control labs\",\"Degerfors Laboratory\",\"elemental analysis\",\"metals\",\"optical emission spectrometry\",\"steel\",\"x-ray fluorescence\"],\"articleSection\":[\"Metals &amp; Alloys\",\"Positive Material Identification\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/\",\"name\":\"VIDEO: OES Provides Reliable Metal Analysis for Contract Lab\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/05\\\/dlabvideo.jpg\",\"datePublished\":\"2014-06-05T12:30:17+00:00\",\"dateModified\":\"2026-02-05T20:05:14+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/f162a5bd108ec475cfa794c96b2757df\"},\"description\":\"See elemental analysis of metals, raw materials and minerals using Optical Emission Spectrometry (OES) instruments\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/05\\\/dlabvideo.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2014\\\/05\\\/dlabvideo.jpg\",\"width\":478,\"height\":266,\"caption\":\"D-Lab VideoImage\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/f162a5bd108ec475cfa794c96b2757df\",\"name\":\"Eric Hovsepian\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3b17d46e2a8edc53c6e47fb52f74e8cb23f3ad69c4577efb8805add26d1a2c21?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3b17d46e2a8edc53c6e47fb52f74e8cb23f3ad69c4577efb8805add26d1a2c21?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/3b17d46e2a8edc53c6e47fb52f74e8cb23f3ad69c4577efb8805add26d1a2c21?s=96&d=mm&r=g\",\"caption\":\"Eric Hovsepian\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/eric-hovsepianthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"VIDEO: OES Provides Reliable Metal Analysis for Contract Lab","description":"See elemental analysis of metals, raw materials and minerals using Optical Emission Spectrometry (OES) instruments","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/","og_locale":"en_US","og_type":"article","og_title":"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory","og_description":"See elemental analysis of metals, raw materials and minerals using Optical Emission Spectrometry (OES) instruments","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2014-06-05T12:30:17+00:00","article_modified_time":"2026-02-05T20:05:14+00:00","og_image":[{"width":478,"height":266,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg","type":"image\/jpeg"}],"author":"Eric Hovsepian","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Eric Hovsepian","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/"},"author":{"name":"Eric Hovsepian","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/f162a5bd108ec475cfa794c96b2757df"},"headline":"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory","datePublished":"2014-06-05T12:30:17+00:00","dateModified":"2026-02-05T20:05:14+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/"},"wordCount":149,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg","keywords":["control labs","Degerfors Laboratory","elemental analysis","metals","optical emission spectrometry","steel","x-ray fluorescence"],"articleSection":["Metals &amp; Alloys","Positive Material Identification"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/","name":"VIDEO: OES Provides Reliable Metal Analysis for Contract Lab","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg","datePublished":"2014-06-05T12:30:17+00:00","dateModified":"2026-02-05T20:05:14+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/f162a5bd108ec475cfa794c96b2757df"},"description":"See elemental analysis of metals, raw materials and minerals using Optical Emission Spectrometry (OES) instruments","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg","width":478,"height":266,"caption":"D-Lab VideoImage"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/video-oes-provides-reliable-metal-analysis-for-contract-laboratory\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"VIDEO: OES Provides Reliable Metal Analysis for Contract Laboratory"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/f162a5bd108ec475cfa794c96b2757df","name":"Eric Hovsepian","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/3b17d46e2a8edc53c6e47fb52f74e8cb23f3ad69c4577efb8805add26d1a2c21?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/3b17d46e2a8edc53c6e47fb52f74e8cb23f3ad69c4577efb8805add26d1a2c21?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/3b17d46e2a8edc53c6e47fb52f74e8cb23f3ad69c4577efb8805add26d1a2c21?s=96&d=mm&r=g","caption":"Eric Hovsepian"},"url":"https:\/\/admin.acceleratingscience.com\/author\/eric-hovsepianthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":7,"label":"Metals &amp; Alloys"},{"value":4,"label":"Positive Material Identification"}],"post_tag":[{"value":157,"label":"control labs"},{"value":158,"label":"Degerfors Laboratory"},{"value":62,"label":"elemental analysis"},{"value":8,"label":"metals"},{"value":32,"label":"optical emission spectrometry"},{"value":26,"label":"steel"},{"value":27,"label":"x-ray fluorescence"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg",478,266,false],"author_info":{"display_name":"Eric Hovsepian","author_link":"https:\/\/admin.acceleratingscience.com\/author\/eric-hovsepianthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":7,"name":"Metals &amp; Alloys","slug":"metals-and-alloys","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":224,"filter":"raw","meta":[],"cat_ID":7,"category_count":224,"category_description":"","cat_name":"Metals &amp; Alloys","category_nicename":"metals-and-alloys","category_parent":0},{"term_id":4,"name":"Positive Material Identification","slug":"positive-material-identification","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":123,"filter":"raw","meta":[],"cat_ID":4,"category_count":123,"category_description":"","cat_name":"Positive Material Identification","category_nicename":"positive-material-identification","category_parent":0}],"tag_info":[{"term_id":157,"name":"control labs","slug":"control-labs","term_group":0,"term_taxonomy_id":157,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":158,"name":"Degerfors Laboratory","slug":"degerfors-laboratory","term_group":0,"term_taxonomy_id":158,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":62,"name":"elemental analysis","slug":"elemental-analysis-2","term_group":0,"term_taxonomy_id":62,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw","meta":[]},{"term_id":8,"name":"metals","slug":"metals-2","term_group":0,"term_taxonomy_id":8,"taxonomy":"post_tag","description":"","parent":0,"count":93,"filter":"raw","meta":[]},{"term_id":32,"name":"optical emission spectrometry","slug":"optical-emission-spectrometry","term_group":0,"term_taxonomy_id":32,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":26,"name":"steel","slug":"steel","term_group":0,"term_taxonomy_id":26,"taxonomy":"post_tag","description":"","parent":0,"count":67,"filter":"raw","meta":[]},{"term_id":27,"name":"x-ray fluorescence","slug":"x-ray-fluorescence","term_group":0,"term_taxonomy_id":27,"taxonomy":"post_tag","description":"","parent":0,"count":10,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":13557,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-improve-inspection-of-small-metal-parts\/","url_meta":{"origin":2646,"position":0},"title":"How to Improve Inspection of Small Metal Parts","author":"Marlene Gasdia-Cochrane","date":"May 26, 2026","format":false,"excerpt":"Article Summary Manufacturers, quality control teams, and field inspectors face a growing challenge when verifying the composition of small metal parts. Components such as fasteners, weld wire, tubing, bolts, and machined pieces are often difficult to analyze accurately. These parts are critical to operational safety and product integrity, yet their\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"small metal fasteners","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13568,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-handheld-xrf-technology-exposed-counterfeit-silver-coins-sold-online\/","url_meta":{"origin":2646,"position":1},"title":"How Handheld XRF Technology Exposed Counterfeit Silver Coins Sold Online","author":"Marlene Gasdia-Cochrane","date":"May 28, 2026","format":false,"excerpt":"Summary Counterfeit silver coins are becoming a growing problem in online marketplaces, putting coin collectors, precious metal investors, pawn shops, and bullion buyers at financial risk. A recent \u00a0NBC Connecticut investigation uncovered fake American Eagle silver bullion coins being sold online at prices far below market value. Although the coins\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Silver coins and silver bullion","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":12889,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/diwali-sparks-gold-buying-frenzy\/","url_meta":{"origin":2646,"position":2},"title":"Diwali Sparks Gold-Buying Frenzy","author":"Marlene Gasdia-Cochrane","date":"October 28, 2025","format":false,"excerpt":"Forty tons of gold, worth $11 billion, was purchased by India in the first two days of Diwali. About 8,000 miles away in New York City, there was a gold buying rush and a cash-for-gold frenzy. Buyers and sellers are banking on the hope that the gold in the pieces\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Diwali Puja Thali With Flowers, Diya, And Gifts","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/iStock-2240362443-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":2646,"position":3},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":2646,"position":4},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13598,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-rhodium-plating-impacts-gold-xrf-analysis-and-karat-verification\/","url_meta":{"origin":2646,"position":5},"title":"How Rhodium Plating Impacts Gold XRF Analysis and Karat Verification","author":"Marlene Gasdia-Cochrane","date":"July 28, 2026","format":false,"excerpt":"Summary Accurate gold analysis is essential for jewelry verification, precious metals trading, refining, and quality control. One of the most widely used methods for determining gold content is X-ray fluorescence (XRF) analysis, a non-destructive testing technique that quickly evaluates metal composition. However, rhodium plating\u2014a common surface treatment used on white\u2026","rel":"","context":"In &quot;Metals &amp; Alloys&quot;","block_context":{"text":"Metals &amp; Alloys","link":"https:\/\/admin.acceleratingscience.com\/metals\/metals-and-alloys\/"},"img":{"alt_text":"Banner of a cube symbolizing element number 45 of the periodic table. Rhodium. (Rh)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2014\/05\/dlabvideo.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/2646","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/53"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=2646"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/2646\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/2645"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=2646"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=2646"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=2646"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=2646"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}