{"id":5696,"date":"2015-09-15T08:00:48","date_gmt":"2015-09-15T12:00:48","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=5696"},"modified":"2026-02-24T20:39:07","modified_gmt":"2026-02-24T20:39:07","slug":"edxrf-how-does-it-work","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/","title":{"rendered":"EDXRF: How Does It Work?"},"content":{"rendered":"<p>The first post in this series, <em><a href=\"http:\/\/admin.acceleratingscience.com\/metals\/laboratory-based-xrf-vs-handheld-xrf-whats-the-difference\/\">Laboratory-based XRF vs. Handheld XRF: What&rsquo;s the Difference?<\/a><\/em> explained that handheld XRF analyzers are designed for situations where immediate feedback is needed, whereas <a href=\"http:\/\/www.thermoscientific.com\/en\/products\/elemental-analysis.html\">lab-based XRF analysis<\/a> has a wider analytical range and is suited for more applications. The two primary types of lab-based XRF systems are <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/arl-quant-x-edxrf-spectrometer.html\">Energy Dispersive X-ray Fluorescence (EDXRF)<\/a> and Wavelength Dispersive X-ray Fluorescence (WDXRF). In this post, we&rsquo;ll provide an overview of EDXRF.<\/p>\n<p>EDXRF is a convenient technology to screen all kinds of materials for quick identification and quantification of elements with little or no sample preparation. Low cost of ownership and rapid elemental analysis of regular or irregular samples make EDXRF an attractive front-end analysis tool.<\/p>\n<p><span style=\"font-size: 18pt\">How EDXRF Works<\/span><\/p>\n<p>EDXRF is designed to analyze groups of elements simultaneously. This type of XRF instrumentation separates the characteristic x-rays of different elements into a complete fluorescence energy spectrum which is then processed for qualitative or quantitative analysis. Filters positioned between sample and detector are used to improve signal, background reduction, and focus on certain regions of the spectra.<\/p>\n<p><span style=\"font-size: 18pt\">Direct Excitation vs. Indirect Excitation<\/span><\/p>\n<p>EDXRF instruments can have one of two types of excitation geometry; direct excitation, or 2D optics, and indirect excitation, also called 3D optics. The purpose of these geometries is to remove the background below the characteristic element lines in the spectrum and to increase the peak-to-background ratio (peak-to-noise). Both types rely on an energy dispersive detector and an x-ray tube; the difference is in the optic path.<\/p>\n<p><strong><span style=\"font-size: 12pt\">Direct Excitation Geometry (2D optics)<\/span><\/strong><\/p>\n<p>In direct excitation geometry, the detector, sample and x-ray tube are positioned in the same plane. Primary x-rays from the tube are filtered according to which elements are being detected. The filtered primary radiation excites the sample elements and the resulting secondary radiation is detected by the detector.<\/p>\n<p><strong><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2015\/09\/opticsdigram5.jpg\" style=\"margin-left: auto;margin-right: auto\" \/><\/strong><\/p>\n<p><strong><span style=\"font-size: 12pt\">Indirect Excitation (3D optics)<\/span><\/strong><\/p>\n<p>Indirect excitation features a 3D geometry with the x-ray tube, secondary target and sample in one plane, and the detector in a perpendicular plane. Instruments with 3D optics direct the primary x-rays first to a secondary target in the sample-target-tube plane, and then to the sample outside the plane. If reflections happen at exactly 90&deg;, the primary radiation coming from the tube, which produces the background in the spectrum, is completely eliminated. However, irradiating the secondary target produces almost monochromatic radiation which is used to excite the sample elements. For EDXRF instruments with a tube power up to 50 Watts, the analytical performance of 2D and 3D are very similar.<\/p>\n<p><span style=\"font-size: 18pt\">Detectors<\/span><\/p>\n<p>The resolution and elemental range achieved by EDXRF analyzers depends on the type of detector used.<\/p>\n<p><strong><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2015\/09\/detectors5.jpg\" style=\"margin-left: auto;margin-right: auto\" \/><\/strong><\/p>\n<p>&nbsp;<\/p>\n<p><span style=\"font-size: 12pt\">Want to learn more about lab-based XRF?&nbsp;&nbsp;<\/span><span style=\"font-size: 12pt\">Download our free eBook:&nbsp;<em><a href=\"http:\/\/info3.thermoscientific.com\/LP=520?wt.mc_id=cad_xrf_LabeBook_banner_blog_0515_metals\" target=\"_blank\">XRF in the Lab&nbsp;for the Non-Scientist<\/a>.<\/em><\/span><em>&nbsp;<\/em><\/p>\n<p><span style=\"font-size: 18pt\"><span style=\"font-size: 12pt\"><em><span>Stay tuned for &nbsp;<strong>WDXRF: How Does It Work?<\/strong>&nbsp;<\/span><\/em><\/span><\/span><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The first post in this series, Laboratory-based XRF vs. Handheld XRF: What&rsquo;s the Difference? explained that handheld XRF analyzers are designed for situations where immediate feedback is needed, whereas lab-based XRF analysis has a wider analytical range and is suited for more applications. The two primary types of lab-based XRF systems are Energy Dispersive X-ray<\/p>\n","protected":false},"author":65,"featured_media":5694,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[154],"tags":[],"division":[],"class_list":{"0":"post-5696","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general-industry-metals","8":"entry"},"_selected_authors":[1451],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>EDXRF: How Does It Work?<\/title>\n<meta name=\"description\" content=\"See how EDXRF can screen metals and materials for quick identification and quantification of elements with little or no sample preparation. Download free ebook.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"EDXRF: How Does It Work?\" \/>\n<meta property=\"og:description\" content=\"See how EDXRF can screen metals and materials for quick identification and quantification of elements with little or no sample preparation. Download free ebook.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-09-15T12:00:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-24T20:39:07+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"553\" \/>\n\t<meta property=\"og:image:height\" content=\"422\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Nathalie Keng\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Nathalie Keng\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/\"},\"author\":{\"name\":\"Nathalie Keng\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/9e2d22a71754e7cdb1413867cb7d87ee\"},\"headline\":\"EDXRF: How Does It Work?\",\"datePublished\":\"2015-09-15T12:00:48+00:00\",\"dateModified\":\"2026-02-24T20:39:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/\"},\"wordCount\":477,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2015\\\/09\\\/opticsdigram.jpg\",\"articleSection\":[\"General\\\/Industry\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/\",\"name\":\"EDXRF: How Does It Work?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2015\\\/09\\\/opticsdigram.jpg\",\"datePublished\":\"2015-09-15T12:00:48+00:00\",\"dateModified\":\"2026-02-24T20:39:07+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/9e2d22a71754e7cdb1413867cb7d87ee\"},\"description\":\"See how EDXRF can screen metals and materials for quick identification and quantification of elements with little or no sample preparation. Download free ebook.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2015\\\/09\\\/opticsdigram.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2015\\\/09\\\/opticsdigram.jpg\",\"width\":553,\"height\":422},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/edxrf-how-does-it-work\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"EDXRF: How Does It Work?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/9e2d22a71754e7cdb1413867cb7d87ee\",\"name\":\"Nathalie Keng\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d55218f1e412432088d586b355783ba4403d40585655cf8ee5eb8049b6bdb8e0?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d55218f1e412432088d586b355783ba4403d40585655cf8ee5eb8049b6bdb8e0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d55218f1e412432088d586b355783ba4403d40585655cf8ee5eb8049b6bdb8e0?s=96&d=mm&r=g\",\"caption\":\"Nathalie Keng\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/nathaliekeng\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"EDXRF: How Does It Work?","description":"See how EDXRF can screen metals and materials for quick identification and quantification of elements with little or no sample preparation. Download free ebook.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/","og_locale":"en_US","og_type":"article","og_title":"EDXRF: How Does It Work?","og_description":"See how EDXRF can screen metals and materials for quick identification and quantification of elements with little or no sample preparation. Download free ebook.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-09-15T12:00:48+00:00","article_modified_time":"2026-02-24T20:39:07+00:00","og_image":[{"width":553,"height":422,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg","type":"image\/jpeg"}],"author":"Nathalie Keng","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Nathalie Keng","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/"},"author":{"name":"Nathalie Keng","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/9e2d22a71754e7cdb1413867cb7d87ee"},"headline":"EDXRF: How Does It Work?","datePublished":"2015-09-15T12:00:48+00:00","dateModified":"2026-02-24T20:39:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/"},"wordCount":477,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg","articleSection":["General\/Industry"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/","name":"EDXRF: How Does It Work?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg","datePublished":"2015-09-15T12:00:48+00:00","dateModified":"2026-02-24T20:39:07+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/9e2d22a71754e7cdb1413867cb7d87ee"},"description":"See how EDXRF can screen metals and materials for quick identification and quantification of elements with little or no sample preparation. Download free ebook.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg","width":553,"height":422},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/edxrf-how-does-it-work\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"EDXRF: How Does It Work?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/9e2d22a71754e7cdb1413867cb7d87ee","name":"Nathalie Keng","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d55218f1e412432088d586b355783ba4403d40585655cf8ee5eb8049b6bdb8e0?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d55218f1e412432088d586b355783ba4403d40585655cf8ee5eb8049b6bdb8e0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d55218f1e412432088d586b355783ba4403d40585655cf8ee5eb8049b6bdb8e0?s=96&d=mm&r=g","caption":"Nathalie Keng"},"url":"https:\/\/admin.acceleratingscience.com\/author\/nathaliekeng\/"}]}},"taxonomy_info":{"category":[{"value":154,"label":"General\/Industry"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg",553,422,false],"author_info":{"display_name":"Nathalie Keng","author_link":"https:\/\/admin.acceleratingscience.com\/author\/nathaliekeng\/"},"comment_info":2,"category_info":[{"term_id":154,"name":"General\/Industry","slug":"general-industry-metals","term_group":0,"term_taxonomy_id":154,"taxonomy":"category","description":"","parent":0,"count":181,"filter":"raw","meta":[],"cat_ID":154,"category_count":181,"category_description":"","cat_name":"General\/Industry","category_nicename":"general-industry-metals","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13568,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-handheld-xrf-technology-exposed-counterfeit-silver-coins-sold-online\/","url_meta":{"origin":5696,"position":0},"title":"How Handheld XRF Technology Exposed Counterfeit Silver Coins Sold Online","author":"Marlene Gasdia-Cochrane","date":"May 28, 2026","format":false,"excerpt":"Summary Counterfeit silver coins are becoming a growing problem in online marketplaces, putting coin collectors, precious metal investors, pawn shops, and bullion buyers at financial risk. A recent \u00a0NBC Connecticut investigation uncovered fake American Eagle silver bullion coins being sold online at prices far below market value. Although the coins\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Silver coins and silver bullion","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":5696,"position":1},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13545,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-maximize-productivity-in-lightweight-metal-scrap-sorting-at-recycling-facilities\/","url_meta":{"origin":5696,"position":2},"title":"How to Maximize Productivity in Lightweight Metal Scrap Sorting at Recycling Facilities","author":"Marlene Gasdia-Cochrane","date":"May 18, 2026","format":false,"excerpt":"Addressing the Challenge of Lightweight Alloy Identification Lightweight metal scrap sorting\u2014especially for aluminum and magnesium alloys\u2014presents a unique operational challenge. While these materials are essential to modern manufacturing and recycling streams, their similar compositions make them difficult to distinguish quickly and accurately. Traditional sorting methods often force a trade-off between\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Compacted aluminum scraps","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":5696,"position":3},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13598,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-rhodium-plating-impacts-gold-xrf-analysis-and-karat-verification\/","url_meta":{"origin":5696,"position":4},"title":"How Rhodium Plating Impacts Gold XRF Analysis and Karat Verification","author":"Marlene Gasdia-Cochrane","date":"July 28, 2026","format":false,"excerpt":"Summary Accurate gold analysis is essential for jewelry verification, precious metals trading, refining, and quality control. One of the most widely used methods for determining gold content is X-ray fluorescence (XRF) analysis, a non-destructive testing technique that quickly evaluates metal composition. However, rhodium plating\u2014a common surface treatment used on white\u2026","rel":"","context":"In &quot;Metals &amp; Alloys&quot;","block_context":{"text":"Metals &amp; Alloys","link":"https:\/\/admin.acceleratingscience.com\/metals\/metals-and-alloys\/"},"img":{"alt_text":"Banner of a cube symbolizing element number 45 of the periodic table. Rhodium. (Rh)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/07\/iStock-2281505711.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":10286,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/a-valentines-special-best-metal-elements-for-a-sturdy-piece-of-jewelry\/","url_meta":{"origin":5696,"position":5},"title":"A Valentine\u2019s Special: Best Metal Elements for a Sturdy Piece of Jewelry","author":"Mark Lessard","date":"February 10, 2026","format":false,"excerpt":"A Pleasant Garden article noted that \"from a global perspective, nearly 6 million couples get engaged on February 14th.\"\u00a0It\u2019s no surprise that many of those who \u2018pop the question\u2019 choose to do it on the day known for its message of love and affection. Those who have bought an engagement\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"ring in box with Valentine heart decorations","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2015\/09\/opticsdigram.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/5696","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=5696"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/5696\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/5694"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=5696"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=5696"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=5696"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=5696"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}