{"id":8033,"date":"2016-04-05T08:00:23","date_gmt":"2016-04-05T12:00:23","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=7983"},"modified":"2016-05-11T12:19:26","modified_gmt":"2016-05-11T12:19:26","slug":"how-moist-is-your-blast-furnace-additives","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/","title":{"rendered":"How Moist Are Your Blast Furnace Additives?"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right; border: 0; margin: 10px;\" title=\"coke oven steel mill -\" src=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/istock_000012976904_medium.jpg\" alt=\"coke oven steel mill -\" width=\"300\" height=\"444\" \/>Did you know that a piece of steel relies on a piece of coal which must have the right moisture content?<\/p>\n<p>Anthracite coal is a hard, glossy black coal that is used in steelmaking.\u00a0 According to the <a href=\"https:\/\/www.steel.org\/making-steel\/how-its-made\/processes\/processes-info\/coal-utilization-in-the-steel-industry.aspx?siteLocation=88e232e1-d52b-4048-9b8a-f687fbd5cdcb\">American Iron and Steel Institute<\/a>:<\/p>\n<p style=\"padding-left: 30px;\">\u201cThe largest single use of coal in the steel industry is as a fuel for the blast furnace, either for the production of metallurgical coke or for injection with the hot blast. Other less commonly thought of uses of coal is for making steam and electricity, as sources of carbon addition in steel making processes, and in direct smelting of iron processes. Furthermore, electricity purchased from outside sources is largely generated from pulverized coal combustion and therefore has an indirect influence on steel making operations.\u201d<\/p>\n<p>The basic materials used for the manufacture of pig iron \u2013 which is used in steelmaking &#8212; are iron ore, coke, and limestone.\u00a0 Coke, which is blackish-gray and has a metallic luster, is the hard, porous residue left after the destructive distillation of coal.<\/p>\n<p>In blast furnace operations, like foundries, coke is the most important raw material because it has an effect on the blast furnace operation, which then has an effect on the hot metal quality. Coke is derived from coal that has been heated to a high temperature and goes through carbonization.\u00a0 However, before carbonization, the supply of coal probably originated from various mines, and was then combined, pulverized, blended and oiled for proper bulk density control.\u00a0 There is a primer by a scientist named Hardarshan S. Valia that does a great job describing <a href=\"http:\/\/www.accci.org\/Steel.pdf\">coke production for blast furnace ironmaking<\/a>.<\/p>\n<p>In his paper, he writes: \u201cA high quality coke should be able to support a smooth descent of the blast furnace burden with as little degradation as possible while providing the lowest amount of impurities, highest thermal energy, highest metal reduction, and optimum permeability for the flow of gaseous and molten products. Introduction of high quality coke to a blast furnace will result in lower coke rate, higher productivity and lower hot metal cost.\u201d<\/p>\n<p>However, even something as harmless as water could affect the integrity of the coke. One of the most important properties of high quality coke is moisture. The wrong amount of moisture can have adverse effects on energy requirements, blast furnace operation, hot metal quality, and\/or refractory lining.<\/p>\n<p>To take the guesswork out of moisture content, mining operators and mineral processors use moisture analyzers that can provide accurate, real time, and cost effective measurements throughout the processing and bulk handling of ore and minerals. Specifically, <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/lfm-sub-3-sub-moisture-analyzer.html\">Low Frequency Microwave (LFM<sub>3<\/sub>) moisture analyzers<\/a> work on the principle that water has a very high dielectric constant compared to most other materials. When microwaves intersect with water molecules within the material they slow down (and hence change phase) and weaken (attenuate) as the energy is transferred to the material.<\/p>\n<p>The resonance frequency of the microwave field is detuned and dampened depending on the water content of the material. The changes in the microwave frequency is measured by the receiver antenna and this signal is then evaluated by the microprocessor based control unit. With the measurement of the above parameters and their evaluation, it is possible to determine moisture content and material density separately. You can read more about this subject in our Advancing Mining article <a href=\"http:\/\/http:\/\/admin.acceleratingscience.com\/mining\/is-your-coal-retaining-moisture\/%20\" target=\"_blank\"><em>Is Your Coal Retaining Moisture?<\/em><\/a><\/p>\n<p>Metal producers have to ensure that the coke they are using in their plants contains the right amount of moisture or it could affect their product, their reputation, and their bottom line.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Did you know that a piece of steel relies on a piece of coal which must have the right moisture content? Anthracite coal is a hard, glossy black coal that is used in steelmaking.\u00a0 According to the American Iron and Steel Institute: \u201cThe largest single use of coal in the steel industry is as a<\/p>\n","protected":false},"author":72,"featured_media":8439,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[3],"tags":[],"division":[],"class_list":{"0":"post-8033","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-manufacturing-quality-assurance","8":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How Moist Is Your Blast Furnace Additives?<\/title>\n<meta name=\"description\" content=\"Metal producers have to ensure that the coke they use in their plants contains the right amount of moisture or it could affect their product and their bottom line.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How Moist Are Your Blast Furnace Additives?\" \/>\n<meta property=\"og:description\" content=\"Metal producers have to ensure that the coke they use in their plants contains the right amount of moisture or it could affect their product and their bottom line.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-04-05T12:00:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-05-11T12:19:26+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"665\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Stephan Nel\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Stephan Nel\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/\"},\"author\":{\"name\":\"Stephan Nel\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/99e4091470d700b494a237af009d20f2\"},\"headline\":\"How Moist Are Your Blast Furnace Additives?\",\"datePublished\":\"2016-04-05T12:00:23+00:00\",\"dateModified\":\"2016-05-11T12:19:26+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/\"},\"wordCount\":598,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/04\\\/casting-part-of-steel-production-at-a-steel-mill.jpg\",\"articleSection\":[\"Manufacturing Quality Assurance\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/\",\"name\":\"How Moist Is Your Blast Furnace Additives?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/04\\\/casting-part-of-steel-production-at-a-steel-mill.jpg\",\"datePublished\":\"2016-04-05T12:00:23+00:00\",\"dateModified\":\"2016-05-11T12:19:26+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/99e4091470d700b494a237af009d20f2\"},\"description\":\"Metal producers have to ensure that the coke they use in their plants contains the right amount of moisture or it could affect their product and their bottom line.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/04\\\/casting-part-of-steel-production-at-a-steel-mill.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2016\\\/04\\\/casting-part-of-steel-production-at-a-steel-mill.jpg\",\"width\":1000,\"height\":665,\"caption\":\"casting, part of steel production at a steel mill\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/how-moist-is-your-blast-furnace-additives\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How Moist Are Your Blast Furnace Additives?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/99e4091470d700b494a237af009d20f2\",\"name\":\"Stephan Nel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g\",\"caption\":\"Stephan Nel\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/stephan-nelthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How Moist Is Your Blast Furnace Additives?","description":"Metal producers have to ensure that the coke they use in their plants contains the right amount of moisture or it could affect their product and their bottom line.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/","og_locale":"en_US","og_type":"article","og_title":"How Moist Are Your Blast Furnace Additives?","og_description":"Metal producers have to ensure that the coke they use in their plants contains the right amount of moisture or it could affect their product and their bottom line.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-04-05T12:00:23+00:00","article_modified_time":"2016-05-11T12:19:26+00:00","og_image":[{"width":1000,"height":665,"url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg","type":"image\/jpeg"}],"author":"Stephan Nel","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Stephan Nel","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/"},"author":{"name":"Stephan Nel","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/99e4091470d700b494a237af009d20f2"},"headline":"How Moist Are Your Blast Furnace Additives?","datePublished":"2016-04-05T12:00:23+00:00","dateModified":"2016-05-11T12:19:26+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/"},"wordCount":598,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg","articleSection":["Manufacturing Quality Assurance"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/","name":"How Moist Is Your Blast Furnace Additives?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg","datePublished":"2016-04-05T12:00:23+00:00","dateModified":"2016-05-11T12:19:26+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/99e4091470d700b494a237af009d20f2"},"description":"Metal producers have to ensure that the coke they use in their plants contains the right amount of moisture or it could affect their product and their bottom line.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg","width":1000,"height":665,"caption":"casting, part of steel production at a steel mill"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/how-moist-is-your-blast-furnace-additives\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"How Moist Are Your Blast Furnace Additives?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/99e4091470d700b494a237af009d20f2","name":"Stephan Nel","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g","caption":"Stephan Nel"},"url":"https:\/\/admin.acceleratingscience.com\/author\/stephan-nelthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":3,"label":"Manufacturing Quality Assurance"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg",760,505,false],"author_info":{"display_name":"Stephan Nel","author_link":"https:\/\/admin.acceleratingscience.com\/author\/stephan-nelthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":3,"name":"Manufacturing Quality Assurance","slug":"manufacturing-quality-assurance","term_group":0,"term_taxonomy_id":3,"taxonomy":"category","description":"","parent":0,"count":155,"filter":"raw","meta":[],"cat_ID":3,"category_count":155,"category_description":"","cat_name":"Manufacturing Quality Assurance","category_nicename":"manufacturing-quality-assurance","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13557,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-improve-inspection-of-small-metal-parts\/","url_meta":{"origin":8033,"position":0},"title":"How to Improve Inspection of Small Metal Parts","author":"Marlene Gasdia-Cochrane","date":"May 26, 2026","format":false,"excerpt":"Article Summary Manufacturers, quality control teams, and field inspectors face a growing challenge when verifying the composition of small metal parts. Components such as fasteners, weld wire, tubing, bolts, and machined pieces are often difficult to analyze accurately. These parts are critical to operational safety and product integrity, yet their\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"small metal fasteners","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1733,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/heres-a-free-periodic-table-for-your-halloween-goody-bag\/","url_meta":{"origin":8033,"position":1},"title":"Here&#8217;s a Free Periodic Table for Your Halloween Goody-Bag","author":"Marlene Gasdia-Cochrane, Editor","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your metals samples. \u00a0It's our treat. Then visit our Steel Manufacturing and Precious Metals Analysis\u00a0 pages for more goodies. Download Periodic Table.\u00a0","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Halloween pumpkin with goodies","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":13404,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/indonesia-investigates-caesium-137-contamination-in-shrimp-linked-to-scrap-metal-imports\/","url_meta":{"origin":8033,"position":2},"title":"Indonesia Investigates Caesium 137 Contamination in Shrimp Linked to Scrap Metal Imports","author":"Marlene Gasdia-Cochrane","date":"March 11, 2026","format":false,"excerpt":"Indonesia has no nuclear weapons or nuclear power plants, so how did Caesium 137, a radioactive isotope, enter Indonesia and contaminate a batch of shrimp, which ended up in the United States, possibly through scrap metal. The Issue: Radiation Contamination of a Food Supply Last Fall, it was reported by\u2026","rel":"","context":"In &quot;Scrap Metal Recycling&quot;","block_context":{"text":"Scrap Metal Recycling","link":"https:\/\/admin.acceleratingscience.com\/metals\/scrap-metal-recycling\/"},"img":{"alt_text":"Caesium, Cesium, on periodic table of the elements. Alkali metal named after Latin caesius, sky-blue. Symbol Cs, atomic number 55. Fission product caesium-137 is extracted from nuclear reactor waste.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":8033,"position":3},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":10286,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/a-valentines-special-best-metal-elements-for-a-sturdy-piece-of-jewelry\/","url_meta":{"origin":8033,"position":4},"title":"A Valentine\u2019s Special: Best Metal Elements for a Sturdy Piece of Jewelry","author":"Mark Lessard","date":"February 10, 2026","format":false,"excerpt":"A Pleasant Garden article noted that \"from a global perspective, nearly 6 million couples get engaged on February 14th.\"\u00a0It\u2019s no surprise that many of those who \u2018pop the question\u2019 choose to do it on the day known for its message of love and affection. Those who have bought an engagement\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"ring in box with Valentine heart decorations","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":8033,"position":5},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2016\/04\/casting-part-of-steel-production-at-a-steel-mill.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/8033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/72"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=8033"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/8033\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/8439"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=8033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=8033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=8033"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=8033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}