{"id":9635,"date":"2017-12-12T13:00:49","date_gmt":"2017-12-12T13:00:49","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/metals\/?p=9635"},"modified":"2023-01-25T22:17:33","modified_gmt":"2023-01-25T22:17:33","slug":"brush-up-on-your-stainless-steels","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/","title":{"rendered":"Brush Up on Your Stainless Steels"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right;border: 0;margin: 10px\" title=\"Brush Up on Your Stainless Steels\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/4\/2017\/12\/stainless20steel.jpg\" alt=\"Brush Up on Your Stainless Steels\" width=\"300\" height=\"272\" \/>There are more than 100 different grades of stainless steel, used in everything from surgical equipment to washing machines, to turbine blades. \u201cStainless\u201d steel is actually a generic term referring to a variety of steel types, including <a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/infographic-austenitic-stainless-steels\/?icid=CAD_blog_metals_2018Jan\">Austenitic<\/a>, <a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/infographic-ferritic-stainless-steels\/?icid=CAD_blog_metals_2018Jan\">Ferritic<\/a>, and <a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/infographic-martensitic-stainless-steels\/?icid=CAD_blog_metals_2018Jan\">Martensitic<\/a>. Stainless steel is made by adding varying amounts of chromium (Cr) and other alloying elements such as nickel (Ni) to iron and carbon to create a corrosion-resistant product. The types of alloys used depend on the final use of the product.\u00a0 Does it need to be high and low temperature resistant? Flexible? Easily fabricated? Strong and durable? Easily cleaned and maintained?\u00a0 Long lasting, with a low lifecycle cost? Aesthetically attractive? Environmentally friendly and recyclable?<\/p>\n<p>The strength and hardness of stainless steel is an advantage in many applications, but the downside of adding strengthening alloys is poor machinability, meaning the material is difficult to cut and wears down the tooling. Processing the material through a <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10144030?icid=CAD_blog_metals_2018Jan\">cold rolling mill<\/a> helps reduce thickness, increase strength and improve the surface finish. <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/SIPRO?icid=CAD_blog_metals_2018Jan\">Hot rolling of steel<\/a> occurs at very high temperatures, above the recrystallization temperature of the material, producing malleable sheets that can be formed in a variety of shapes. The process produces sheets that can be extremely long, which are then rolled into coils.<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/measurement-control-systems\/metals-coating-weight-thickness-measurement-gauges.html?icid=CAD_blog_metals_2018Jan\">X-ray based metal coating weight and thickness sensors<\/a> are used for accurate, real-time measurements to ensure the stainless steel is on spec, whether the steel is being hot or cold rolled.<\/p>\n<p>Want to learn more about stainless steels?\u00a0 We have compiled a list of our most-read articles about stainless steel and listed them below so you can access them all from one location.<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/what-is-stainless-steel-part-i\/?icid=CAD_blog_metals_2018Jan\">What Is Stainless Steel? Part I<\/a><br \/>\nRead this introduction to the world\u2019s most popular metal. Learn what it is made of, how it is used, and what the word \u2018stainless\u2019 really means when referring to a variety of steel types.<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/what-is-stainless-steel-part-ii\/?icid=CAD_blog_metals_2018Jan\">What is Stainless Steel? Part II: The Stainless Steel Extended Family<\/a><br \/>\nThe multitude of stainless steel grades are grouped into five primary classifications. Find out which is the most widely used type of stainless steel, which has better corrosion, heat, and cracking resistance, and which is very hard and strong, though not as resistant to corrosion.<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/what-do-stainless-steel-and-garlic-have-in-common\/?icid=CAD_blog_metals_2018Jan\">What Do Stainless Steel and Garlic Have in Common?<\/a><br \/>\nTellurium is a metalloid, meaning it possesses the properties of both metals and nonmetals. It has a silvery-white appearance, and exhibits a metallic luster when pure. It\u2019s an additive to steel, but can lead to a garlic odor on the breath upon human exposure.<\/p>\n<p><a href=\"http:\/\/bit.ly\/2AAVsXy\" target=\"_blank\" rel=\"noopener\">PMI Testing of 347 Stainless Steel: As-Delivered vs. As-Welded<\/a>In a competitive industrial climate, manufacturers must be vigilant about maintaining the quality of their products.\u00a0 Even the smallest deviation from specifications of items like raw materials,\u00a0<a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/xrf-provides-quality-assurance-of-critical-fasteners\/?icid=CAD_blog_metals_2018Jan\">fasteners<\/a>, and welds can affect the quality of the product and the reputation of the company.<\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/blog\/metals\/why-surface-analysis-is-the-key-to-optimum-stainless-steel-performance\/?icid=CAD_blog_metals_2018Jan\">Why Surface Analysis Is the Key to Optimum Stainless Steel Performance<\/a><br \/>\nEnsuring a surface is free from contaminants is extremely important in guaranteeing that materials such as steel meet their desired performance specifications. Learn about an experiment and results using an XPS instrument to acquire elemental maps to identify the spatial distribution and chemical nature of the contamination on a stainless steel sample.<\/p>\n<p>And if you want to take a look at a piece of stainless steel, just walk into your kitchen.\u00a0 Most cutlery, knife blades, kitchen accessories, and cookware are made of this strong, corrosion resistant metal.<\/p>\n<p><em>Additional Resources:<\/em><\/p>\n<ul>\n<li>Download our free <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/steel-manufacturing-ebook-registration-form.html?icid=CAD_blog_metals_2023\">eBook: A Practical Guide to Improving Steel Manufacturing Processes and Production Methods<\/a><\/li>\n<li><em>Visit our center for <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/steel-manufacturing.html?icid=CAD_blog_metals_bottomsteelresourcelink\">Improving Steel Manufacturing Processes and Production<\/a><\/em><\/li>\n<\/ul>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/steel-manufacturing.html?icid=CAD_blog_metals_bottomsteelbanner\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-12003 size-full aligncenter\" src=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/01\/steelbanner.jpg\" alt=\"visit our improving steel processes center\" width=\"1415\" height=\"291\" srcset=\"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/01\/steelbanner.jpg 1415w, https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/01\/steelbanner-300x62.jpg 300w, https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/01\/steelbanner-1024x211.jpg 1024w, https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2023\/01\/steelbanner-768x158.jpg 768w\" sizes=\"auto, (max-width: 1415px) 100vw, 1415px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>There are more than 100 different grades of stainless steel, used in everything from surgical equipment to washing machines, to turbine blades. \u201cStainless\u201d steel is actually a generic term referring to a variety of steel types, including Austenitic, Ferritic, and Martensitic. Stainless steel is made by adding varying amounts of chromium (Cr) and other alloying<\/p>\n","protected":false},"author":38,"featured_media":9704,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[154,7,206],"tags":[22,39,40,41,83,25,26],"division":[],"class_list":{"0":"post-9635","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general-industry-metals","8":"category-metals-and-alloys","9":"category-steel","10":"tag-alloys","11":"tag-manufacturing","12":"tag-metal","13":"tag-metal-alloys","14":"tag-positive-material-identification-2","15":"tag-stainless-steel","16":"tag-steel","17":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Brush Up on Your Stainless Steels - Analyzing Metals<\/title>\n<meta name=\"description\" content=\"Learn about the technologies used to verify metals and alloys to help ensure they meet quality and customer specifications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Brush Up on Your Stainless Steels\" \/>\n<meta property=\"og:description\" content=\"Learn about the technologies used to verify metals and alloys to help ensure they meet quality and customer specifications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2017-12-12T13:00:49+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-01-25T22:17:33+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"801\" \/>\n\t<meta property=\"og:image:height\" content=\"414\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marlene Gasdia-Cochrane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marlene Gasdia-Cochrane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/\"},\"author\":{\"name\":\"Marlene Gasdia-Cochrane\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/11bbcaf39c3abda3e0648991cb0f5ea8\"},\"headline\":\"Brush Up on Your Stainless Steels\",\"datePublished\":\"2017-12-12T13:00:49+00:00\",\"dateModified\":\"2023-01-25T22:17:33+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/\"},\"wordCount\":606,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2017\\\/12\\\/stainlesssteelthumb.jpg\",\"keywords\":[\"alloys\",\"manufacturing\",\"metal\",\"metal alloys\",\"positive material identification\",\"stainless steel\",\"steel\"],\"articleSection\":[\"General\\\/Industry\",\"Metals &amp; Alloys\",\"Steel\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/\",\"name\":\"Brush Up on Your Stainless Steels - Analyzing Metals\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2017\\\/12\\\/stainlesssteelthumb.jpg\",\"datePublished\":\"2017-12-12T13:00:49+00:00\",\"dateModified\":\"2023-01-25T22:17:33+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/11bbcaf39c3abda3e0648991cb0f5ea8\"},\"description\":\"Learn about the technologies used to verify metals and alloys to help ensure they meet quality and customer specifications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2017\\\/12\\\/stainlesssteelthumb.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2017\\\/12\\\/stainlesssteelthumb.jpg\",\"width\":801,\"height\":414},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/brush-up-on-your-stainless-steels\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Brush Up on Your Stainless Steels\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/11bbcaf39c3abda3e0648991cb0f5ea8\",\"name\":\"Marlene Gasdia-Cochrane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"caption\":\"Marlene Gasdia-Cochrane\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mgasdiacochrane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Brush Up on Your Stainless Steels - Analyzing Metals","description":"Learn about the technologies used to verify metals and alloys to help ensure they meet quality and customer specifications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/","og_locale":"en_US","og_type":"article","og_title":"Brush Up on Your Stainless Steels","og_description":"Learn about the technologies used to verify metals and alloys to help ensure they meet quality and customer specifications.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2017-12-12T13:00:49+00:00","article_modified_time":"2023-01-25T22:17:33+00:00","og_image":[{"width":801,"height":414,"url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg","type":"image\/jpeg"}],"author":"Marlene Gasdia-Cochrane","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Marlene Gasdia-Cochrane","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/"},"author":{"name":"Marlene Gasdia-Cochrane","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/11bbcaf39c3abda3e0648991cb0f5ea8"},"headline":"Brush Up on Your Stainless Steels","datePublished":"2017-12-12T13:00:49+00:00","dateModified":"2023-01-25T22:17:33+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/"},"wordCount":606,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg","keywords":["alloys","manufacturing","metal","metal alloys","positive material identification","stainless steel","steel"],"articleSection":["General\/Industry","Metals &amp; Alloys","Steel"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/","name":"Brush Up on Your Stainless Steels - Analyzing Metals","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg","datePublished":"2017-12-12T13:00:49+00:00","dateModified":"2023-01-25T22:17:33+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/11bbcaf39c3abda3e0648991cb0f5ea8"},"description":"Learn about the technologies used to verify metals and alloys to help ensure they meet quality and customer specifications.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg","width":801,"height":414},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/brush-up-on-your-stainless-steels\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"Brush Up on Your Stainless Steels"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/11bbcaf39c3abda3e0648991cb0f5ea8","name":"Marlene Gasdia-Cochrane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","caption":"Marlene Gasdia-Cochrane"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"}]}},"taxonomy_info":{"category":[{"value":154,"label":"General\/Industry"},{"value":7,"label":"Metals &amp; Alloys"},{"value":206,"label":"Steel"}],"post_tag":[{"value":22,"label":"alloys"},{"value":39,"label":"manufacturing"},{"value":40,"label":"metal"},{"value":41,"label":"metal alloys"},{"value":83,"label":"positive material identification"},{"value":25,"label":"stainless steel"},{"value":26,"label":"steel"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg",760,393,false],"author_info":{"display_name":"Marlene Gasdia-Cochrane","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"},"comment_info":0,"category_info":[{"term_id":154,"name":"General\/Industry","slug":"general-industry-metals","term_group":0,"term_taxonomy_id":154,"taxonomy":"category","description":"","parent":0,"count":182,"filter":"raw","meta":[],"cat_ID":154,"category_count":182,"category_description":"","cat_name":"General\/Industry","category_nicename":"general-industry-metals","category_parent":0},{"term_id":7,"name":"Metals &amp; Alloys","slug":"metals-and-alloys","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":224,"filter":"raw","meta":[],"cat_ID":7,"category_count":224,"category_description":"","cat_name":"Metals &amp; Alloys","category_nicename":"metals-and-alloys","category_parent":0},{"term_id":206,"name":"Steel","slug":"steel","term_group":0,"term_taxonomy_id":206,"taxonomy":"category","description":"steel manufacturing","parent":0,"count":187,"filter":"raw","meta":[],"cat_ID":206,"category_count":187,"category_description":"steel manufacturing","cat_name":"Steel","category_nicename":"steel","category_parent":0}],"tag_info":[{"term_id":22,"name":"alloys","slug":"alloys","term_group":0,"term_taxonomy_id":22,"taxonomy":"post_tag","description":"","parent":0,"count":68,"filter":"raw","meta":[]},{"term_id":39,"name":"manufacturing","slug":"manufacturing","term_group":0,"term_taxonomy_id":39,"taxonomy":"post_tag","description":"","parent":0,"count":54,"filter":"raw","meta":[]},{"term_id":40,"name":"metal","slug":"metal","term_group":0,"term_taxonomy_id":40,"taxonomy":"post_tag","description":"","parent":0,"count":47,"filter":"raw","meta":[]},{"term_id":41,"name":"metal alloys","slug":"metal-alloys","term_group":0,"term_taxonomy_id":41,"taxonomy":"post_tag","description":"","parent":0,"count":68,"filter":"raw","meta":[]},{"term_id":83,"name":"positive material identification","slug":"positive-material-identification-2","term_group":0,"term_taxonomy_id":83,"taxonomy":"post_tag","description":"","parent":0,"count":48,"filter":"raw","meta":[]},{"term_id":25,"name":"stainless steel","slug":"stainless-steel","term_group":0,"term_taxonomy_id":25,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw","meta":[]},{"term_id":26,"name":"steel","slug":"steel","term_group":0,"term_taxonomy_id":26,"taxonomy":"post_tag","description":"","parent":0,"count":67,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":13557,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-improve-inspection-of-small-metal-parts\/","url_meta":{"origin":9635,"position":0},"title":"How to Improve Inspection of Small Metal Parts","author":"Marlene Gasdia-Cochrane","date":"May 26, 2026","format":false,"excerpt":"Article Summary Manufacturers, quality control teams, and field inspectors face a growing challenge when verifying the composition of small metal parts. Components such as fasteners, weld wire, tubing, bolts, and machined pieces are often difficult to analyze accurately. These parts are critical to operational safety and product integrity, yet their\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"small metal fasteners","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":9635,"position":1},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1733,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/heres-a-free-periodic-table-for-your-halloween-goody-bag\/","url_meta":{"origin":9635,"position":2},"title":"Here&#8217;s a Free Periodic Table for Your Halloween Goody-Bag","author":"Marlene Gasdia-Cochrane, Editor","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your metals samples. \u00a0It's our treat. Then visit our Steel Manufacturing and Precious Metals Analysis\u00a0 pages for more goodies. Download Periodic Table.\u00a0","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Halloween pumpkin with goodies","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2025\/10\/MetalsHalloween-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":9635,"position":3},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":10286,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/a-valentines-special-best-metal-elements-for-a-sturdy-piece-of-jewelry\/","url_meta":{"origin":9635,"position":4},"title":"A Valentine\u2019s Special: Best Metal Elements for a Sturdy Piece of Jewelry","author":"Mark Lessard","date":"February 10, 2026","format":false,"excerpt":"A Pleasant Garden article noted that \"from a global perspective, nearly 6 million couples get engaged on February 14th.\"\u00a0It\u2019s no surprise that many of those who \u2018pop the question\u2019 choose to do it on the day known for its message of love and affection. Those who have bought an engagement\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"ring in box with Valentine heart decorations","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":13545,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-maximize-productivity-in-lightweight-metal-scrap-sorting-at-recycling-facilities\/","url_meta":{"origin":9635,"position":5},"title":"How to Maximize Productivity in Lightweight Metal Scrap Sorting at Recycling Facilities","author":"Marlene Gasdia-Cochrane","date":"May 18, 2026","format":false,"excerpt":"Addressing the Challenge of Lightweight Alloy Identification Lightweight metal scrap sorting\u2014especially for aluminum and magnesium alloys\u2014presents a unique operational challenge. While these materials are essential to modern manufacturing and recycling streams, their similar compositions make them difficult to distinguish quickly and accurately. Traditional sorting methods often force a trade-off between\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Compacted aluminum scraps","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2017\/12\/stainlesssteelthumb.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/9635","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/38"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=9635"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/9635\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/9704"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=9635"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=9635"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=9635"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=9635"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}