{"id":9857,"date":"2018-05-08T12:00:42","date_gmt":"2018-05-08T12:00:42","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/metals\/?p=9857"},"modified":"2026-07-28T20:21:37","modified_gmt":"2026-07-28T20:21:37","slug":"adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/","title":{"rendered":"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg\" style=\"float: right;border: 0;margin: 10px\" alt=\"rolled aluminum coils\" title=\"rolled aluminum coils\" width=\"450\" height=\"300\" \/>Sheet metal is thin steel, aluminum, or other alloyed metal that is used in both manufacturing and construction. It has strength and flexibility, and is the ideal material for industrial and consumer applications, like buildings, cars, transport vehicles, heating and air conditioning systems, power generation, medical devices, siding, signs, etc.<\/p>\n<p>Because it is used in so many different products and industries, sheet metal endures cutting, bending,<span>&nbsp; <\/span>drilling of holes for screws and bolts, welding, riveting, and soldering.<span>&nbsp; <\/span>Not only does the &lsquo;recipe&rsquo; of the material need to be correct, but the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/measurement-control-systems\/metals-coating-weight-thickness-measurement-gauges.html?icid=CAD_blog_metals_2018May\">thickness of the metal<\/a> strip must be exact as well.<\/p>\n<p>Many believe that metal strip quality begins in the meltshop, and that is not far from the truth. Controlling the chemistry and thermal history of the steel not only assures the grade produced will meet the mechanical properties desired of the final product, but that the strip will handle the tons of pressure and tensions of the high speed rolling process.<\/p>\n<p>According to <a href=\"http:\/\/www.businessdictionary.com\/definition\/cold-rolling.html\">BusinessDictionary,<\/a> cold-rolled steel is a metal forming process in which &ldquo;the shape and structure of steel is altered through drawing, extruding, hammering, pressing, rolling, spinning, and\/or stretching at temperatures below the steel&#8217;s recrystalization point (usually room temperature). These operations cause changes in the metal&#8217;s composition which permanently increase its hardness and tensile strength, and enhance surface finish, but decrease ductility and impact resistance.&rdquo;<\/p>\n<p>In roughing mills, equipment is used to reduce the thickness of the steel while at the same time extending the overall length, to form the metal to roughly the final thickness. The Hot Finish mill forms the strip to the final dimension.<span>&nbsp; <\/span>Not only does temperature plays a crucial part in these processes as it dictates the quality of the surface finish and sheet thickness, but so does speed.<span>&nbsp; <\/span>As I mentioned, the metal is subjected to tons of pressure and tensions of the high speed rolling process.<\/p>\n<p style=\"text-align: left\">The following table summarizes the typical thicknesses and rolling speeds for each mill type. Not surprisingly, as the material gets thinner, the speeds increase dramatically.<\/p>\n<p style=\"text-align: center\">&nbsp;<\/p>\n<table style=\"height: 227px;margin-left: auto;margin-right: auto\" width=\"594\">\n<tbody>\n<tr>\n<td>\n<p>&nbsp;<\/p>\n<\/td>\n<td>\n<p><strong>Hot Roughing Mill <\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Hot Finish Mill <\/strong><\/p>\n<\/td>\n<td>\n<p><strong>Cold Rolling Mill<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Maximum Thickness<\/span><\/p>\n<\/td>\n<td>\n<p><span>&gt; 400 mm<\/span><\/p>\n<\/td>\n<td>\n<p style=\"text-align: left\"><span>20-50 mm<\/span><\/p>\n<\/td>\n<td>\n<p><span>3-20 mm<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Minimum Thickness<\/span><\/p>\n<\/td>\n<td>\n<p><span>20-50 mm<\/span><\/p>\n<\/td>\n<td>\n<p><span>3-20 mm<\/span><\/p>\n<\/td>\n<td>\n<p><span>0.100 mm<\/span><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><span>Rolling speeds (meters per min)<\/span><\/p>\n<\/td>\n<td>\n<p><span>~ 100<\/span><\/p>\n<\/td>\n<td>\n<p><span>~1000<\/span><\/p>\n<\/td>\n<td>\n<p><span>~2000<\/span><\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center\">&nbsp;<\/p>\n<p><span>Automatic Gauge Control (AGC) is an essential component of modern rolling mills. Comprehensive AGC algorithms incorporate readings from dozens of sensors around the mill to control thickness to high tolerances..<\/span><\/p>\n<p><span>Some of the key AGC input parameters are speed and tension. Conservation of mass dictates that the mass per unit time entering the mill must equal the mass per unit time exiting the mill. So as the material is rolled thinner, the speeds must increase. If the drive motors are off, even by a few centimeters per minute, the strip may break or cobble with catastrophic results. There is a delicate balance between the reduction caused by the mill force, and the reduction caused by drawing (extruding) the material through the gap.<\/span><\/p>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/manufacturing-processing\/measurement-control-systems\/metals-coating-weight-thickness-measurement-gauges.html?icid=CAD_blog_metals_2018May\"><span>Metals coating weight and thickness measurement gauges<\/span><\/a><span> provide precise, real-time measurements that help meet specifications of various applications while maximizing raw material use. <\/span><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10144030?icid=CAD_blog_metals_2018May\"><span>Thickness gauges<\/span><\/a><span> are primarily used to look for dramatic deviations in thickness &ndash; which could affect the mechanical properties of the finished product. Small changes can be corrected by slight adjustments in speed and tension, as the motor power can be controlled very quickly. Larger changes can be compensated by the hydraulic cylinders in the mill stand, which can react in a matter of milliseconds.<\/span><\/p>\n<p><span><a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/117628?\">X-ray gauges<\/a>&nbsp;<\/span><span>are the optimal thickness gauge technology to provide the speed and accuracy required to operate a cold rolling mill. X-ray based sensor systems provide extremely accurate high speed\/low noise measurements, permitting producers to realize material savings and quality improvements.<\/span><\/p>\n<p><span>&nbsp;<\/span><\/p>\n<p><em><span>NOTE: To read additional details about High Speed X-ray Thickness Gauges, including illustrations, read the white paper, <\/span><\/em><a href=\"http:\/\/tools.thermofisher.com\/content\/sfs\/brochures\/Optimization-of-a-Cold-Rolling-Mill.pdf?icid=CAD_blog_metals_2018May\"><em><span>Optimization of a Cold Rolling Mill with a High Speed X-ray Thickness Gauge<\/span><\/em><\/a><em><span>.<\/span><\/em><\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Sheet metal is thin steel, aluminum, or other alloyed metal that is used in both manufacturing and construction. It has strength and flexibility, and is the ideal material for industrial and consumer applications, like buildings, cars, transport vehicles, heating and air conditioning systems, power generation, medical devices, siding, signs, etc. Because it is used in<\/p>\n","protected":false},"author":38,"featured_media":9912,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[3,7,105,206],"tags":[],"division":[],"class_list":["post-9857","post","type-post","status-publish","format-standard","has-post-thumbnail","category-manufacturing-quality-assurance","category-metals-and-alloys","category-metals-measurement","category-steel","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality - Analyzing Metals<\/title>\n<meta name=\"description\" content=\"Learn how adjusting rolling speed and strip thickness improves metal strip quality, reduces defects, and enhances process control in rolling mill operations.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality\" \/>\n<meta property=\"og:description\" content=\"Learn how adjusting rolling speed and strip thickness improves metal strip quality, reduces defects, and enhances process control in rolling mill operations.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2018-05-08T12:00:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-07-28T20:21:37+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marlene Gasdia-Cochrane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marlene Gasdia-Cochrane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/\"},\"author\":{\"name\":\"Marlene Gasdia-Cochrane\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\"},\"headline\":\"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality\",\"datePublished\":\"2018-05-08T12:00:42+00:00\",\"dateModified\":\"2026-07-28T20:21:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/\"},\"wordCount\":679,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/05\\\/istock-676500062_alumcoils.jpg\",\"articleSection\":[\"Manufacturing Quality Assurance\",\"Metals &amp; Alloys\",\"Metals Measurement\",\"Steel\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/\",\"name\":\"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality - Analyzing Metals\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/05\\\/istock-676500062_alumcoils.jpg\",\"datePublished\":\"2018-05-08T12:00:42+00:00\",\"dateModified\":\"2026-07-28T20:21:37+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\"},\"description\":\"Learn how adjusting rolling speed and strip thickness improves metal strip quality, reduces defects, and enhances process control in rolling mill operations.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/05\\\/istock-676500062_alumcoils.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/05\\\/istock-676500062_alumcoils.jpg\",\"width\":724,\"height\":483,\"caption\":\"rolled aluminum coils\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\",\"name\":\"Marlene Gasdia-Cochrane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"caption\":\"Marlene Gasdia-Cochrane\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mgasdiacochrane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality - Analyzing Metals","description":"Learn how adjusting rolling speed and strip thickness improves metal strip quality, reduces defects, and enhances process control in rolling mill operations.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/","og_locale":"en_US","og_type":"article","og_title":"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality","og_description":"Learn how adjusting rolling speed and strip thickness improves metal strip quality, reduces defects, and enhances process control in rolling mill operations.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2018-05-08T12:00:42+00:00","article_modified_time":"2026-07-28T20:21:37+00:00","og_image":[{"width":724,"height":483,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg","type":"image\/jpeg"}],"author":"Marlene Gasdia-Cochrane","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Marlene Gasdia-Cochrane","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/"},"author":{"name":"Marlene Gasdia-Cochrane","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8"},"headline":"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality","datePublished":"2018-05-08T12:00:42+00:00","dateModified":"2026-07-28T20:21:37+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/"},"wordCount":679,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg","articleSection":["Manufacturing Quality Assurance","Metals &amp; Alloys","Metals Measurement","Steel"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/","name":"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality - Analyzing Metals","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg","datePublished":"2018-05-08T12:00:42+00:00","dateModified":"2026-07-28T20:21:37+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8"},"description":"Learn how adjusting rolling speed and strip thickness improves metal strip quality, reduces defects, and enhances process control in rolling mill operations.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg","width":724,"height":483,"caption":"rolled aluminum coils"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/adjusting-rolling-speed-and-thickness-to-help-ensure-metal-strip-quality\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"Adjusting Rolling Speed and Thickness to Help Ensure Metal Strip Quality"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8","name":"Marlene Gasdia-Cochrane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","caption":"Marlene Gasdia-Cochrane"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"}]}},"taxonomy_info":{"category":[{"value":3,"label":"Manufacturing Quality Assurance"},{"value":7,"label":"Metals &amp; Alloys"},{"value":105,"label":"Metals Measurement"},{"value":206,"label":"Steel"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg",724,483,false],"author_info":{"display_name":"Marlene Gasdia-Cochrane","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"},"comment_info":0,"category_info":[{"term_id":3,"name":"Manufacturing Quality Assurance","slug":"manufacturing-quality-assurance","term_group":0,"term_taxonomy_id":3,"taxonomy":"category","description":"","parent":0,"count":156,"filter":"raw","meta":[],"cat_ID":3,"category_count":156,"category_description":"","cat_name":"Manufacturing Quality Assurance","category_nicename":"manufacturing-quality-assurance","category_parent":0},{"term_id":7,"name":"Metals &amp; Alloys","slug":"metals-and-alloys","term_group":0,"term_taxonomy_id":7,"taxonomy":"category","description":"","parent":0,"count":225,"filter":"raw","meta":[],"cat_ID":7,"category_count":225,"category_description":"","cat_name":"Metals &amp; Alloys","category_nicename":"metals-and-alloys","category_parent":0},{"term_id":105,"name":"Metals Measurement","slug":"metals-measurement","term_group":0,"term_taxonomy_id":105,"taxonomy":"category","description":"","parent":0,"count":20,"filter":"raw","meta":[],"cat_ID":105,"category_count":20,"category_description":"","cat_name":"Metals Measurement","category_nicename":"metals-measurement","category_parent":0},{"term_id":206,"name":"Steel","slug":"steel","term_group":0,"term_taxonomy_id":206,"taxonomy":"category","description":"steel manufacturing","parent":0,"count":187,"filter":"raw","meta":[],"cat_ID":206,"category_count":187,"category_description":"steel manufacturing","cat_name":"Steel","category_nicename":"steel","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13964,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/why-accurate-metal-and-alloy-fabrication-matters-take-the-quiz\/","url_meta":{"origin":9857,"position":0},"title":"Why Accurate Metal and Alloy Fabrication Matters; Take the Quiz","author":"Marlene Gasdia-Cochrane","date":"November 10, 2026","format":false,"excerpt":"Article Summary Accurate metal and alloy fabrication is essential for producing reliable, safe, and high-performance components across industries such as aerospace, automotive, construction, energy, and medical manufacturing. Fabrication accuracy involves selecting the correct materials, verifying chemical composition, maintaining dimensional tolerances, and controlling manufacturing processes. Even small deviations can compromise structural\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"Cnc milling machine. Processing and laser cutting for metal in the industrial. Motion blur. Industrial exhibition of machine tools.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/11\/iStock-1432698628_fabrication-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/11\/iStock-1432698628_fabrication-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/11\/iStock-1432698628_fabrication-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/11\/iStock-1432698628_fabrication-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/11\/iStock-1432698628_fabrication-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/11\/iStock-1432698628_fabrication-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13557,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-improve-inspection-of-small-metal-parts\/","url_meta":{"origin":9857,"position":1},"title":"How to Improve Inspection of Small Metal Parts","author":"Marlene Gasdia-Cochrane","date":"May 26, 2026","format":false,"excerpt":"Article Summary Manufacturers, quality control teams, and field inspectors face a growing challenge when verifying the composition of small metal parts. Components such as fasteners, weld wire, tubing, bolts, and machined pieces are often difficult to analyze accurately. These parts are critical to operational safety and product integrity, yet their\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"small metal fasteners","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":9857,"position":2},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13857,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/eight-reasons-jewelers-should-not-use-acid-to-test-jewelry\/","url_meta":{"origin":9857,"position":3},"title":"Eight Reasons Jewelers Should NOT Use Acid to Test Jewelry","author":"Marlene Gasdia-Cochrane","date":"October 16, 2026","format":false,"excerpt":"Introduction Traditional acid testing can provide a useful initial indication of precious metal purity, but authoritative sources recognize its limitations when more precise analysis is needed. The Convention on the Control and Marking of Articles of Precious Metals describes touch acid testing as providing a \u201cgood early indication of fineness\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Jeweller's workshop","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/10\/iStock-1062676800_jewelryacid.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":10286,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/a-valentines-special-best-metal-elements-for-a-sturdy-piece-of-jewelry\/","url_meta":{"origin":9857,"position":4},"title":"A Valentine\u2019s Special: Best Metal Elements for a Sturdy Piece of Jewelry","author":"Mark Lessard","date":"February 10, 2026","format":false,"excerpt":"A Pleasant Garden article noted that \"from a global perspective, nearly 6 million couples get engaged on February 14th.\"\u00a0It\u2019s no surprise that many of those who \u2018pop the question\u2019 choose to do it on the day known for its message of love and affection. Those who have bought an engagement\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"ring in box with Valentine heart decorations","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2019\/02\/istock-96917265_valentinejewelry.jpg?resize=700%2C400&ssl=1 2x"},"classes":[]},{"id":13545,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-maximize-productivity-in-lightweight-metal-scrap-sorting-at-recycling-facilities\/","url_meta":{"origin":9857,"position":5},"title":"How to Maximize Productivity in Lightweight Metal Scrap Sorting at Recycling Facilities","author":"Marlene Gasdia-Cochrane","date":"May 18, 2026","format":false,"excerpt":"Addressing the Challenge of Lightweight Alloy Identification Lightweight metal scrap sorting\u2014especially for aluminum and magnesium alloys\u2014presents a unique operational challenge. While these materials are essential to modern manufacturing and recycling streams, their similar compositions make them difficult to distinguish quickly and accurately. Traditional sorting methods often force a trade-off between\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Compacted aluminum scraps","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/05\/istock-676500062_alumcoils.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/9857","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/38"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=9857"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/9857\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/9912"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=9857"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=9857"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=9857"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=9857"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}