{"id":9921,"date":"2018-06-19T12:00:20","date_gmt":"2018-06-19T12:00:20","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/metals\/?p=9921"},"modified":"2026-08-07T21:01:27","modified_gmt":"2026-08-07T21:01:27","slug":"metallic-glass-can-be-created-using-3d-printing","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/","title":{"rendered":"Metallic Glass Can Be Created Using 3D Printing"},"content":{"rendered":"<p><a href=\"https:\/\/www.ien.com\/product-development\/news\/20998573\/metallic-glass-alloys-made-with-3d-printing\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" style=\"float: right;border: 0;margin: 10px\" title=\"metallic glass\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg\" width=\"350\" height=\"233\" \/>Industrial Equipment News<\/a> reports that amorphous metal, or metallic glass alloys, can be made using 3D printing technology. The discovery may lead to a variety of applications, such as more efficient electric motors, better wear-resistant materials, higher strength materials, and lighter weight structures.<\/p>\n<p>Making metallic glass requires rapid cooling to prevent the crystalline structure from forming. Historically, that meant researchers could only cast metallic glasses into small thicknesses, called an alloy&#8217;s critical casting thickness.<\/p>\n<p>The technique works by applying a laser to a layer of metal powder, melting the powder into a solid layer that is only 20 microns thick. The &#8220;build platform&#8221; then descends 20 microns, more powder is spread onto the surface, and the process repeats itself. Because the alloy is formed a little at a time, it cools quickly &#8211; retaining its amorphous qualities. However, the end result is a solid, metallic glass object &#8211; not an object made of laminated, discrete layers of the alloy.<\/p>\n<p>Zaynab Mahbooba, first author of a paper on the work and a Ph.D. student in North Carolina State University&#8217;s Department of Materials Science and Engineering, said, &#8220;It will take some trial and error to find the alloy compositions that have the best combination of properties for any given application. For instance, you want to make sure you not only have the desirable electromagnetic properties, but that the alloy isn&#8217;t too brittle for practical use.&#8221;<\/p>\n<p>The researchers\u2019 work is presented in a paper titled <em>Additive manufacturing of an iron-based bulk metallic glass larger than the critical casting thickness<\/em>.<\/p>\n<h3>Alloys for 3D and traditional manufacturing<\/h3>\n<p>3D-printed metal alloys offer the advantages of design flexibility with less material waste and cost. Metal powders tailored to specific 3D printing technologies are emerging rapidly to meet the many applications in the aerospace, automotive\u00a0 and other industries. Formulations include various grades of stainless steel, low alloy steels, nickel and cobalt alloys, titanium alloys, or other metal alloys.<\/p>\n<p><a href=\"http:\/\/bit.ly\/2wIyIIc\" target=\"_blank\" rel=\"noopener\">Metal alloy composition<\/a> is an important aspect of both 3D and traditional manufacturing. In either case, metal alloys are made from designated percentages of different elements to have the appropriate properties for specific applications, and in either case, wrong or out-of-specification alloys can lead to performance issues and part failures.<\/p>\n<p>In traditional manufacturing processes, <a href=\"http:\/\/bit.ly\/2KoCOar\" target=\"_blank\" rel=\"noopener\">X-ray fluorescence (XRF)<\/a>\u00a0is a proven technology for the elemental analysis of specialty alloys to ensure the correct alloys are combined in the right percentages and the finished material meets precise manufacturing specifications.\u00a0XRF is a nondestructive technique that can determine the elemental composition of a sample within seconds, helping to ensure that no incorrect or out-of-specification metal alloys caused by material mix-ups, lost traceability, incorrect weld chemistry and dilution, or even counterfeit materials enter the manufacturing process.<\/p>\n<p><a href=\"http:\/\/bit.ly\/2GggfC6\" target=\"_blank\" rel=\"noopener\">Portable XRF analyzers<\/a>\u00a0are indispensable tools for performing PMI of incoming raw materials, work in progress, and final quality assurance of finished parts because they can determine the elemental composition of a sample within seconds.<\/p>\n<p><em><strong>Recommended reading:<\/strong><\/em><\/p>\n<p><a href=\"http:\/\/bit.ly\/2jTOdDP\" target=\"_blank\" rel=\"noopener\">Application Note: Advancements in PMI Tools Bring Accuracy and Convenience to the Work Site<\/a><\/p>\n<p><a href=\"http:\/\/bit.ly\/2jUz3hB\" target=\"_blank\" rel=\"noopener\">Application Note: Analysis of Microalloying Elements in Steel Using the Thermo Scientific Niton XL5<\/a><\/p>\n<p><a href=\"http:\/\/bit.ly\/2Imfeuh\" target=\"_blank\" rel=\"noopener\">Application Note: Conducting Retroactive PMI<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Industrial Equipment News reports that amorphous metal, or metallic glass alloys, can be made using 3D printing technology. The discovery may lead to a variety of applications, such as more efficient electric motors, better wear-resistant materials, higher strength materials, and lighter weight structures. Making metallic glass requires rapid cooling to prevent the crystalline structure from<\/p>\n","protected":false},"author":49,"featured_media":9954,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[154],"tags":[],"division":[],"class_list":["post-9921","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general-industry-metals","entry"],"_selected_authors":[1223],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Metallic Glass Can Be Created Using 3D Printing - Analyzing Metals<\/title>\n<meta name=\"description\" content=\"Discover how 3D printing enables the creation of metallic glass with unique strength, durability, and potential for advanced manufacturing applications.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Metallic Glass Can Be Created Using 3D Printing\" \/>\n<meta property=\"og:description\" content=\"Discover how 3D printing enables the creation of metallic glass with unique strength, durability, and potential for advanced manufacturing applications.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/\" \/>\n<meta property=\"og:site_name\" content=\"Analyzing Metals\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2018-06-19T12:00:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-07T21:01:27+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Mark Lessard\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Mark Lessard\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/\"},\"author\":{\"name\":\"Mark Lessard\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/7264df50acdc9799cfaa1da7d0c2fd91\"},\"headline\":\"Metallic Glass Can Be Created Using 3D Printing\",\"datePublished\":\"2018-06-19T12:00:20+00:00\",\"dateModified\":\"2026-08-07T21:01:27+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/\"},\"wordCount\":532,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/06\\\/metallic20glass.jpg\",\"articleSection\":[\"General\\\/Industry\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/\",\"name\":\"Metallic Glass Can Be Created Using 3D Printing - Analyzing Metals\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/06\\\/metallic20glass.jpg\",\"datePublished\":\"2018-06-19T12:00:20+00:00\",\"dateModified\":\"2026-08-07T21:01:27+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/7264df50acdc9799cfaa1da7d0c2fd91\"},\"description\":\"Discover how 3D printing enables the creation of metallic glass with unique strength, durability, and potential for advanced manufacturing applications.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/06\\\/metallic20glass.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/wp-content\\\/uploads\\\/sites\\\/4\\\/2018\\\/06\\\/metallic20glass.jpg\",\"width\":724,\"height\":483,\"caption\":\"sky view of building made of glass and metal\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/metals\\\/metallic-glass-can-be-created-using-3d-printing\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Metallic Glass Can Be Created Using 3D Printing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/\",\"name\":\"Analyzing Metals\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/metals\\\/#\\\/schema\\\/person\\\/7264df50acdc9799cfaa1da7d0c2fd91\",\"name\":\"Mark Lessard\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/736032608fe65aa1d4aed604da069f0242e7708f5e3e2d15a69d70669b25fb38?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/736032608fe65aa1d4aed604da069f0242e7708f5e3e2d15a69d70669b25fb38?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/736032608fe65aa1d4aed604da069f0242e7708f5e3e2d15a69d70669b25fb38?s=96&d=mm&r=g\",\"caption\":\"Mark Lessard\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mark-lessardthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Metallic Glass Can Be Created Using 3D Printing - Analyzing Metals","description":"Discover how 3D printing enables the creation of metallic glass with unique strength, durability, and potential for advanced manufacturing applications.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/","og_locale":"en_US","og_type":"article","og_title":"Metallic Glass Can Be Created Using 3D Printing","og_description":"Discover how 3D printing enables the creation of metallic glass with unique strength, durability, and potential for advanced manufacturing applications.","og_url":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/","og_site_name":"Analyzing Metals","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2018-06-19T12:00:20+00:00","article_modified_time":"2026-08-07T21:01:27+00:00","og_image":[{"width":724,"height":483,"url":"http:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg","type":"image\/jpeg"}],"author":"Mark Lessard","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Mark Lessard","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/"},"author":{"name":"Mark Lessard","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/7264df50acdc9799cfaa1da7d0c2fd91"},"headline":"Metallic Glass Can Be Created Using 3D Printing","datePublished":"2018-06-19T12:00:20+00:00","dateModified":"2026-08-07T21:01:27+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/"},"wordCount":532,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg","articleSection":["General\/Industry"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/","url":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/","name":"Metallic Glass Can Be Created Using 3D Printing - Analyzing Metals","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg","datePublished":"2018-06-19T12:00:20+00:00","dateModified":"2026-08-07T21:01:27+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/7264df50acdc9799cfaa1da7d0c2fd91"},"description":"Discover how 3D printing enables the creation of metallic glass with unique strength, durability, and potential for advanced manufacturing applications.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg","width":724,"height":483,"caption":"sky view of building made of glass and metal"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/metals\/metallic-glass-can-be-created-using-3d-printing\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/metals\/"},{"@type":"ListItem","position":2,"name":"Metallic Glass Can Be Created Using 3D Printing"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#website","url":"https:\/\/admin.acceleratingscience.com\/metals\/","name":"Analyzing Metals","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/metals\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/metals\/#\/schema\/person\/7264df50acdc9799cfaa1da7d0c2fd91","name":"Mark Lessard","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/736032608fe65aa1d4aed604da069f0242e7708f5e3e2d15a69d70669b25fb38?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/736032608fe65aa1d4aed604da069f0242e7708f5e3e2d15a69d70669b25fb38?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/736032608fe65aa1d4aed604da069f0242e7708f5e3e2d15a69d70669b25fb38?s=96&d=mm&r=g","caption":"Mark Lessard"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mark-lessardthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":154,"label":"General\/Industry"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg",724,483,false],"author_info":{"display_name":"Mark Lessard","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mark-lessardthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":154,"name":"General\/Industry","slug":"general-industry-metals","term_group":0,"term_taxonomy_id":154,"taxonomy":"category","description":"","parent":0,"count":182,"filter":"raw","meta":[],"cat_ID":154,"category_count":182,"category_description":"","cat_name":"General\/Industry","category_nicename":"general-industry-metals","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13429,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-identify-aluminum-in-a-scrap-metal-recycling-yard\/","url_meta":{"origin":9921,"position":0},"title":"How to Identify Aluminum in a Scrap Metal Recycling Yard","author":"Marlene Gasdia-Cochrane","date":"May 5, 2026","format":false,"excerpt":"Identifying aluminum in a scrap metal recycling yard is more challenging than it might seem. While aluminum is one of the most widely used and recycled metals, its physical similarities to other materials, combined with the complexity of aluminum alloys, make accurate identification difficult. This challenge has significant implications for\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Scrap metal pieces laying in a pile","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-133993685_scrapaluminum.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13568,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-handheld-xrf-technology-exposed-counterfeit-silver-coins-sold-online\/","url_meta":{"origin":9921,"position":1},"title":"How Handheld XRF Technology Exposed Counterfeit Silver Coins Sold Online","author":"Marlene Gasdia-Cochrane","date":"May 28, 2026","format":false,"excerpt":"Summary Counterfeit silver coins are becoming a growing problem in online marketplaces, putting coin collectors, precious metal investors, pawn shops, and bullion buyers at financial risk. A recent \u00a0NBC Connecticut investigation uncovered fake American Eagle silver bullion coins being sold online at prices far below market value. Although the coins\u2026","rel":"","context":"In &quot;Precious Metals&quot;","block_context":{"text":"Precious Metals","link":"https:\/\/admin.acceleratingscience.com\/metals\/precious-metals\/"},"img":{"alt_text":"Silver coins and silver bullion","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-482324309.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13404,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/indonesia-investigates-caesium-137-contamination-in-shrimp-linked-to-scrap-metal-imports\/","url_meta":{"origin":9921,"position":2},"title":"Indonesia Investigates Caesium 137 Contamination in Shrimp Linked to Scrap Metal Imports","author":"Marlene Gasdia-Cochrane","date":"March 11, 2026","format":false,"excerpt":"Indonesia has no nuclear weapons or nuclear power plants, so how did Caesium 137, a radioactive isotope, enter Indonesia and contaminate a batch of shrimp, which ended up in the United States, possibly through scrap metal. The Issue: Radiation Contamination of a Food Supply Last Fall, it was reported by\u2026","rel":"","context":"In &quot;Scrap Metal Recycling&quot;","block_context":{"text":"Scrap Metal Recycling","link":"https:\/\/admin.acceleratingscience.com\/metals\/scrap-metal-recycling\/"},"img":{"alt_text":"Caesium, Cesium, on periodic table of the elements. Alkali metal named after Latin caesius, sky-blue. Symbol Cs, atomic number 55. Fission product caesium-137 is extracted from nuclear reactor waste.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/03\/iStock-1413396579_caesium.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13418,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/buyer-and-seller-beware-how-to-detect-fake-gold-in-current-times\/","url_meta":{"origin":9921,"position":3},"title":"Buyer and Seller Beware: How to Detect Fake Gold in Current Times","author":"Marlene Gasdia-Cochrane","date":"April 7, 2026","format":false,"excerpt":"A Practical Guide for Jewelers and Pawn Shop Owners The rise in gold prices and continued market volatility have made precious metals more attractive\u2014not just to legitimate sellers, but also to increasingly sophisticated counterfeiters. For jewelers, cash-for-gold operators, and pawn shop owners, the ability to accurately verify gold authenticity and\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Clasp on a 14k Gold necklace with markings on a black background","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-1133424222_14k-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13557,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-improve-inspection-of-small-metal-parts\/","url_meta":{"origin":9921,"position":4},"title":"How to Improve Inspection of Small Metal Parts","author":"Marlene Gasdia-Cochrane","date":"May 26, 2026","format":false,"excerpt":"Article Summary Manufacturers, quality control teams, and field inspectors face a growing challenge when verifying the composition of small metal parts. Components such as fasteners, weld wire, tubing, bolts, and machined pieces are often difficult to analyze accurately. These parts are critical to operational safety and product integrity, yet their\u2026","rel":"","context":"In &quot;Manufacturing Quality Assurance&quot;","block_context":{"text":"Manufacturing Quality Assurance","link":"https:\/\/admin.acceleratingscience.com\/metals\/manufacturing-quality-assurance\/"},"img":{"alt_text":"small metal fasteners","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/05\/iStock-1087432242.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13545,"url":"https:\/\/www.thermofisher.com\/blog\/metals\/how-to-maximize-productivity-in-lightweight-metal-scrap-sorting-at-recycling-facilities\/","url_meta":{"origin":9921,"position":5},"title":"How to Maximize Productivity in Lightweight Metal Scrap Sorting at Recycling Facilities","author":"Marlene Gasdia-Cochrane","date":"May 18, 2026","format":false,"excerpt":"Addressing the Challenge of Lightweight Alloy Identification Lightweight metal scrap sorting\u2014especially for aluminum and magnesium alloys\u2014presents a unique operational challenge. While these materials are essential to modern manufacturing and recycling streams, their similar compositions make them difficult to distinguish quickly and accurately. Traditional sorting methods often force a trade-off between\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/metals\/general-industry-metals\/"},"img":{"alt_text":"Compacted aluminum scraps","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2026\/04\/iStock-163265634_alumscrapblocks-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/metals\/wp-content\/uploads\/sites\/4\/2018\/06\/metallic20glass.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/9921","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/users\/49"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/comments?post=9921"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/posts\/9921\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media\/9954"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/media?parent=9921"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/categories?post=9921"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/tags?post=9921"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/metals\/wp-json\/wp\/v2\/division?post=9921"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}