
{"id":10203,"date":"2017-04-04T12:00:51","date_gmt":"2017-04-04T12:00:51","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/mining\/?p=10203"},"modified":"2026-02-03T13:15:23","modified_gmt":"2026-02-03T13:15:23","slug":"tailings-no-longer-trash-an-update-on-reprocessing-technologies","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/","title":{"rendered":"Tailings No Longer Trash? An Update on Reprocessing Technologies"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg\" style=\"float: right;border: 0;margin: 10px\" alt=\"mining tailings\" title=\"mining tailings\" width=\"450\" height=\"300\" \/>Tailings, mineral waste products produced by mining operations, are a well known pollutant requiring remediation. However, in recent years some mining companies have developed novel reprocessing technologies to extract valuable metals from the waste. As we first described in the post, <a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/from-tailings-to-treasure-a-new-mother-lode?icid=CAD_blog_mining_040417\">From Tailings to Treasure? A New Mother Lode<\/a>, very small diamonds can be recovered from the residue of the original diamond-bearing ore, and the <a href=\"http:\/\/www.usgs.gov\/\">U.S. Geological Survey<\/a> found that discarded mine tailings may yield significant amounts of rare earth elements.<\/p>\n<p>An article on the <a href=\"https:\/\/www2.deloitte.com\/za\/en\/pages\/energy-and-resources\/articles\/converting-tailings-dumps-into-mineral-resources.html\">Deloitte web site<\/a> points to several examples where developments in mineral processing technology have made the retreatment of numerous tailings dumps possible&mdash;and profitable. These include the processing of platinum group elements (PGEs) from the UG2 reef in the Bushveld Complex (BC) of South Africa to recover chrome, and the processing of chrome ore in the Lower Group reefs of the BC to recover PGEs. Several commercially profitable enterprises have also been set up to retreat tailings dumps from South Africa&rsquo;s Witwatersrand gold processing operations.&nbsp;The article explains that business need to determine the economic viability of their mineral assets, as well as the the quality of the tailings material, the grade variability, and mineralogy before starting a tailings reprocessing program.<\/p>\n<p>To accurately identify minerals within tailings, geologists may use analytical technologies including both <a href=\"http:\/\/www.thermoscientific.com\/en\/products\/x-ray-fluorescence-xrf.html?icid=CAD_blog_mining_040417\">laboratory and portable X-ray fluorescence (XRF) instruments<\/a>. Portable XRF analyzers provide fast, accurate analysis of tailings to quickly and easily gauge the efficiency of extraction and enrichment processes.&nbsp;The real-time assay data provided by a <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/niton-fxl-field-x-ray-lab.html?icid=CAD_blog_mining_040417\">portable XRF analyzer<\/a>&nbsp;allows for timely process adjustments and productivity improvements.&nbsp;<\/p>\n<p>Another potential advantage to reprocessing mine tailings is described in a recent article on <a href=\"https:\/\/phys.org\/news\/2017-02-metalloid-oxide-bacteria-manitoba-nopiming.html\">Phys.org<\/a>. Researchers from the University of Manitoba tested toxic metalloid-reducing bacteria discovered in highly polluted abandoned gold mine tailings in Manitoba&#8217;s Nopiming Provincial Park. The researchers &nbsp;found that these bacteria, or their enzymes, may be useful for the development of bioremediation technologies, a treatment that uses naturally occurring organisms to break down toxic substances. Dr. Vladimir Yurkov, a professor at the university, explains, &#8220;These bacteria have the ability to convert toxic components that exist as a result of mining activities into less toxic forms and are prevalent in extreme environments.&#8221; The byproducts left over from the abandoned mining operation remain highly polluted with heavy metalloid oxides. The researchers studied aerobic anoxygenic phototrophs (AAPs) from soil samples at four different sites and found that five of the strains could grow under a wide range of temperature, acidity and salt content. All of them were highly resistant to toxic metalloid oxides, and were able to convert toxic tellurite to the less toxic elemental form tellurium, a process which could potentially contribute to decontamination of the tailings. The study was published in the&nbsp;<em>Canadian Journal of Microbiology<\/em>.<\/p>\n<p><span style=\"font-size: 14pt\"><em>Recommended reading:<\/em><\/span><\/p>\n<ul>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/mining-and-the-environment-what-happens-when-a-mine-closes?icid=CAD_blog_mining_040417\">Mining and the Environment: What Happens When A Mine Closes?<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/green-mining-can-it-really-happen-part-1?icid=CAD_blog_mining_040417\">Green Mining: Can It Really Happen? Part 1<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/green-mining-can-it-really-happen-part-2?icid=CAD_blog_mining_040417\">Green Mining: Can It Really Happen? Part 2<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/determining-the-rheological-properties-of-mine-tailings?icid=CAD_blog_mining_040417\">Determining the Rheological Properties of Mine Tailings<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings?icid=CAD_blog_mining_040417\">Correlating Yield Stress with Pumpability of Mining Tailings<\/a><\/li>\n<li><a href=\"https:\/\/www.thermofisher.com\/blog\/mining\/video-integrated-tailings-solutions-in-mineral-beneficiation-plants?icid=CAD_blog_mining_040417\">VIDEO: Integrated Tailings Solutions in Mineral Beneficiation Plants<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>Tailings, mineral waste products produced by mining operations, are a well known pollutant requiring remediation. However, in recent years some mining companies have developed novel reprocessing technologies to extract valuable metals from the waste. As we first described in the post, From Tailings to Treasure? A New Mother Lode, very small diamonds can be recovered<\/p>\n","protected":false},"author":70,"featured_media":10237,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[225],"tags":[],"division":[],"class_list":["post-10203","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","entry"],"_selected_authors":[1288],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Tailings No Longer Trash? An Update on Reprocessing Technologies<\/title>\n<meta name=\"description\" content=\"To accurately identify minerals within tailings, geologists use analytical technologies including laboratory and portable X-ray fluorescence (XRF) instruments\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Tailings No Longer Trash? An Update on Reprocessing Technologies\" \/>\n<meta property=\"og:description\" content=\"To accurately identify minerals within tailings, geologists use analytical technologies including laboratory and portable X-ray fluorescence (XRF) instruments\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2017-04-04T12:00:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-03T13:15:23+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2048\" \/>\n\t<meta property=\"og:image:height\" content=\"1365\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chris Calam\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chris Calam\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/\"},\"author\":{\"name\":\"Chris Calam\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/3d1917c11beba7b7a7830f2ca6900cf5\"},\"headline\":\"Tailings No Longer Trash? An Update on Reprocessing Technologies\",\"datePublished\":\"2017-04-04T12:00:51+00:00\",\"dateModified\":\"2026-02-03T13:15:23+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/\"},\"wordCount\":533,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/04\\\/istock-586717726_tailings.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/\",\"name\":\"Tailings No Longer Trash? An Update on Reprocessing Technologies\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/04\\\/istock-586717726_tailings.jpg\",\"datePublished\":\"2017-04-04T12:00:51+00:00\",\"dateModified\":\"2026-02-03T13:15:23+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/3d1917c11beba7b7a7830f2ca6900cf5\"},\"description\":\"To accurately identify minerals within tailings, geologists use analytical technologies including laboratory and portable X-ray fluorescence (XRF) instruments\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/04\\\/istock-586717726_tailings.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2017\\\/04\\\/istock-586717726_tailings.jpg\",\"width\":2048,\"height\":1365,\"caption\":\"mining tailings\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Tailings No Longer Trash? An Update on Reprocessing Technologies\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/3d1917c11beba7b7a7830f2ca6900cf5\",\"name\":\"Chris Calam\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g\",\"caption\":\"Chris Calam\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/chris-calamthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Tailings No Longer Trash? An Update on Reprocessing Technologies","description":"To accurately identify minerals within tailings, geologists use analytical technologies including laboratory and portable X-ray fluorescence (XRF) instruments","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/","og_locale":"en_US","og_type":"article","og_title":"Tailings No Longer Trash? An Update on Reprocessing Technologies","og_description":"To accurately identify minerals within tailings, geologists use analytical technologies including laboratory and portable X-ray fluorescence (XRF) instruments","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2017-04-04T12:00:51+00:00","article_modified_time":"2026-02-03T13:15:23+00:00","og_image":[{"width":2048,"height":1365,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg","type":"image\/jpeg"}],"author":"Chris Calam","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Chris Calam","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/"},"author":{"name":"Chris Calam","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/3d1917c11beba7b7a7830f2ca6900cf5"},"headline":"Tailings No Longer Trash? An Update on Reprocessing Technologies","datePublished":"2017-04-04T12:00:51+00:00","dateModified":"2026-02-03T13:15:23+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/"},"wordCount":533,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/","name":"Tailings No Longer Trash? An Update on Reprocessing Technologies","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg","datePublished":"2017-04-04T12:00:51+00:00","dateModified":"2026-02-03T13:15:23+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/3d1917c11beba7b7a7830f2ca6900cf5"},"description":"To accurately identify minerals within tailings, geologists use analytical technologies including laboratory and portable X-ray fluorescence (XRF) instruments","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg","width":2048,"height":1365,"caption":"mining tailings"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/tailings-no-longer-trash-an-update-on-reprocessing-technologies\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Tailings No Longer Trash? An Update on Reprocessing Technologies"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/3d1917c11beba7b7a7830f2ca6900cf5","name":"Chris Calam","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g","caption":"Chris Calam"},"url":"https:\/\/admin.acceleratingscience.com\/author\/chris-calamthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":225,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings-1024x683.jpg",760,507,true],"author_info":{"display_name":"Chris Calam","author_link":"https:\/\/admin.acceleratingscience.com\/author\/chris-calamthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":225,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":225,"taxonomy":"category","description":"","parent":0,"count":160,"filter":"raw","meta":[],"cat_ID":225,"category_count":160,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":10203,"position":0},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":10203,"position":1},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":10203,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":10203,"position":3},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14164,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-analytical-technologies-support-an-expanding-u-s-power-generation-industry\/","url_meta":{"origin":10203,"position":4},"title":"How Analytical Technologies Support an Expanding U.S. Power Generation Industry","author":"Marlene Gasdia-Cochrane","date":"October 20, 2026","format":false,"excerpt":"Introduction Breaking Energy News (BEN), IIR Intelligence, recently reported that U.S. power-generation projects totaling $16.8 billion were slated to begin construction in September 2026, led by solar, natural gas, and battery storage. The 60 projects represent more than 18 GW of capacity, including roughly 11.4 GW of new generation, reflecting\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Equipment, cables and piping as found inside of a modern industrial power plant\"n","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":10203,"position":5},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2017\/04\/istock-586717726_tailings.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/10203","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/70"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=10203"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/10203\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/10237"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=10203"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=10203"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=10203"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=10203"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}