{"id":1033,"date":"2013-08-20T08:00:00","date_gmt":"2013-08-20T12:00:00","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=1033"},"modified":"2026-01-21T18:53:47","modified_gmt":"2026-01-21T18:53:47","slug":"can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/","title":{"rendered":"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?"},"content":{"rendered":"<p>Elemental <a href=\"http:\/\/www.thermoscientific.com\/ecomm\/servlet\/techresource?resourceId=95841&amp;storeId=11152&amp;from=search\">analysis of mined ore<\/a>, its concentrates and re\ufb01ned products is an important part of any mining and metal re\ufb01ning operation. X-ray Fluorescence (XRF) spectrometry has proven to be a very reliable and cost-effective elemental analysis technique. As shown by this <a title=\"Applications of High Performance XRF\" href=\"http:\/\/ow.ly\/ogMo4\" target=\"_blank\" rel=\"noopener\">scientific poster<\/a> high performance wavelength-dispersive X-ray fluorescence (WD-XRF) has multiple applications in mining laboratories. \u00a0But what about energy-dispersive X-ray fluorescence (EDXRF)? \u00a0Is this technique suitable to handle a common application such as the determination of zinc (Zn), lead (Pb), barium (Ba), iron (Fe) and silicon (Si) in a variety of sul\ufb01de ores?<\/p>\n<p><span style=\"font-size: revert;color: initial\">We took this challenge to an <\/span><a style=\"font-size: revert\" href=\"http:\/\/www.thermoscientific.com\/ecomm\/servlet\/productsdetail?productId=11961756&amp;groupType=PRODUCT&amp;searchType=0&amp;storeId=11152&amp;from=search\">EDXRF spectrometer<\/a><span style=\"font-size: revert;color: initial\">. The \u00a0EDXRF spectrometer we used for the testing combines a low-power X-ray tube and a single highly sensitive Si(Li) detector to generate and measure the emission lines of all elements from Sodium (Na, Z=11) to Uranium (U, Z=92).\u00a0 While EDXRF has increasingly limited sensitivity to lighter elements and is rarely used to measure Sodium (Na) or Magnesium (Mg) at concentrations below 1 %, medium to heavy element sensitivity can easily compete with more expensive WDXRF spectrometers, in some cases even outperforming it. In EDXRF, primary beam filters allow for targeted excitation to \ufb02uoresce only the elements of interest assuring the necessary sensitivity and precision. An instrument with more \ufb02exibility and control over the excitation efficiency and background suppression typically shows better performance. In this case, three spectra were collected off each ore sample, for a total counting time of 3 minutes in a low vacuum atmosphere. The analytical settings are shown below.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" style=\"margin-left: auto;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2013\/08\/sulfides11.jpg\" alt=\"\" \/><\/p>\n<p><span style=\"font-size: revert;color: initial\">Each spectrum is acquired with a different filter\/excitation voltage combination, optimizing for different analytes. <\/span><span style=\"font-size: revert;color: initial\">\u00a0The results reported below were obtained using multivariate regression analysis based on 14 secondary standards with nominal values obtained by Inductively Coupled Plasma spectroscopy (ICP). This table shows the Standard Error of Estimate (SEE) for the analytes of interest. The SEE is the average difference between the nominal and calculated concentrations of a given analyte and is a measure of the accuracy of the calculated concentrations.<\/span><\/p>\n<p><img decoding=\"async\" class=\"aligncenter\" style=\"margin-left: auto;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2013\/08\/sulfide21.jpg\" alt=\"\" \/><\/p>\n<p><span style=\"font-size: revert;color: initial\">Repeatability tests were also performed to show the precision achieved for the 3-minute total counting time. Below are the results for one of the analyzed samples showing the repeatability values (1-Sigma). <\/span><img decoding=\"async\" class=\"aligncenter\" style=\"margin-left: auto;margin-right: auto\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2013\/08\/sulfide31.jpg\" alt=\"\" \/><\/p>\n<p><span style=\"font-size: revert;color: initial\">The EDXRF spectrometer successfully analyzed a variety of elements in mining ore. All it takes is a simple three-minute analysis under vacuum to achieve a precision of less than 1 % relative standard deviation (RSD) for all major components. Needless to say an EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in a variety of sul\ufb01de ores, and avoids the difficulty, expense and delays associated with traditional wet chemical analysis.\u00a0 <\/span><\/p>\n<p><span style=\"font-size: revert;color: initial\">You can read the more detailed application note <\/span><a style=\"font-size: revert\" href=\"https:\/\/static.thermoscientific.com\/images\/D01596~.pdf\">here<\/a><span style=\"font-size: revert;color: initial\">.\u00a0\u00a0<\/span><\/p>\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Elemental analysis of mined ore, its concentrates and re\ufb01ned products is an important part of any mining and metal re\ufb01ning operation. X-ray Fluorescence (XRF) spectrometry has proven to be a very reliable and cost-effective elemental analysis technique. As shown by this scientific poster high performance wavelength-dispersive X-ray fluorescence (WD-XRF) has multiple applications in mining laboratories.<\/p>\n","protected":false},"author":42,"featured_media":1030,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[6,12],"tags":[73,16,85,159],"division":[],"class_list":{"0":"post-1033","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-elemental-geochemical-analysis","8":"category-laboratory-analysis","9":"tag-edxrf","10":"tag-mining-2","11":"tag-spectrometer","12":"tag-sulfide-ores","13":"entry"},"_selected_authors":[771],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Can XRF Spectrometer Accurately Measure elements in Sul\ufb01de Ores?<\/title>\n<meta name=\"description\" content=\"EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in sul\ufb01de ores &amp; avoids the difficulty, expense and delays of wet chemical analysis.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul\ufb01de-ores\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?\" \/>\n<meta property=\"og:description\" content=\"EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in sul\ufb01de ores &amp; avoids the difficulty, expense and delays of wet chemical analysis.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul\ufb01de-ores\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2013-08-20T12:00:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-21T18:53:47+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"354\" \/>\n\t<meta property=\"og:image:height\" content=\"129\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Pascal Lemberge\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Pascal Lemberge\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/\"},\"author\":{\"name\":\"Pascal Lemberge\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/3f5303684ff2330e3dd813cf7fa60877\"},\"headline\":\"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?\",\"datePublished\":\"2013-08-20T12:00:00+00:00\",\"dateModified\":\"2026-01-21T18:53:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/\"},\"wordCount\":465,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2013\\\/08\\\/sulfides1.jpg\",\"keywords\":[\"edxrf\",\"mining\",\"spectrometer\",\"sulfide ores\"],\"articleSection\":[\"Elemental\\\/Geochemical Analysis\",\"Laboratory Analysis\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/\",\"name\":\"Can XRF Spectrometer Accurately Measure elements in Sul\ufb01de Ores?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2013\\\/08\\\/sulfides1.jpg\",\"datePublished\":\"2013-08-20T12:00:00+00:00\",\"dateModified\":\"2026-01-21T18:53:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/3f5303684ff2330e3dd813cf7fa60877\"},\"description\":\"EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in sul\ufb01de ores & avoids the difficulty, expense and delays of wet chemical analysis.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2013\\\/08\\\/sulfides1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2013\\\/08\\\/sulfides1.jpg\",\"width\":354,\"height\":129},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/3f5303684ff2330e3dd813cf7fa60877\",\"name\":\"Pascal Lemberge\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g\",\"caption\":\"Pascal Lemberge\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/pascal-lembergethermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Can XRF Spectrometer Accurately Measure elements in Sul\ufb01de Ores?","description":"EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in sul\ufb01de ores & avoids the difficulty, expense and delays of wet chemical analysis.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul\ufb01de-ores\/","og_locale":"en_US","og_type":"article","og_title":"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?","og_description":"EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in sul\ufb01de ores & avoids the difficulty, expense and delays of wet chemical analysis.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul\ufb01de-ores\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2013-08-20T12:00:00+00:00","article_modified_time":"2026-01-21T18:53:47+00:00","og_image":[{"width":354,"height":129,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg","type":"image\/jpeg"}],"author":"Pascal Lemberge","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Pascal Lemberge","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/"},"author":{"name":"Pascal Lemberge","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/3f5303684ff2330e3dd813cf7fa60877"},"headline":"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?","datePublished":"2013-08-20T12:00:00+00:00","dateModified":"2026-01-21T18:53:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/"},"wordCount":465,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg","keywords":["edxrf","mining","spectrometer","sulfide ores"],"articleSection":["Elemental\/Geochemical Analysis","Laboratory Analysis"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/","name":"Can XRF Spectrometer Accurately Measure elements in Sul\ufb01de Ores?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg","datePublished":"2013-08-20T12:00:00+00:00","dateModified":"2026-01-21T18:53:47+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/3f5303684ff2330e3dd813cf7fa60877"},"description":"EDXRF spectrometer can accurately measure Zn, Pb, Ba, Fe and Si in sul\ufb01de ores & avoids the difficulty, expense and delays of wet chemical analysis.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg","width":354,"height":129},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/can-an-xrf-spectrometer-accurately-measure-zn-pb-ba-fe-and-si-in-a-variety-of-sul%ef%ac%81de-ores\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Can an XRF Spectrometer Accurately Measure Zn, Pb, Ba, Fe and Si in a Variety of Sul\ufb01de Ores?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/3f5303684ff2330e3dd813cf7fa60877","name":"Pascal Lemberge","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c1de52ece21eea3f24124b9a1ae87a1384f39f8afa5b6816b73a812a159a658a?s=96&d=mm&r=g","caption":"Pascal Lemberge"},"url":"https:\/\/admin.acceleratingscience.com\/author\/pascal-lembergethermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":6,"label":"Elemental\/Geochemical Analysis"},{"value":12,"label":"Laboratory Analysis"}],"post_tag":[{"value":73,"label":"edxrf"},{"value":16,"label":"mining"},{"value":85,"label":"spectrometer"},{"value":159,"label":"sulfide ores"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg",354,129,false],"author_info":{"display_name":"Pascal Lemberge","author_link":"https:\/\/admin.acceleratingscience.com\/author\/pascal-lembergethermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":6,"name":"Elemental\/Geochemical Analysis","slug":"elemental-geochemical-analysis","term_group":0,"term_taxonomy_id":6,"taxonomy":"category","description":"","parent":0,"count":144,"filter":"raw","meta":[],"cat_ID":6,"category_count":144,"category_description":"","cat_name":"Elemental\/Geochemical Analysis","category_nicename":"elemental-geochemical-analysis","category_parent":0},{"term_id":12,"name":"Laboratory Analysis","slug":"laboratory-analysis","term_group":0,"term_taxonomy_id":12,"taxonomy":"category","description":"","parent":0,"count":65,"filter":"raw","meta":[],"cat_ID":12,"category_count":65,"category_description":"","cat_name":"Laboratory Analysis","category_nicename":"laboratory-analysis","category_parent":0}],"tag_info":[{"term_id":73,"name":"edxrf","slug":"edxrf","term_group":0,"term_taxonomy_id":73,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":16,"name":"mining","slug":"mining-2","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":111,"filter":"raw","meta":[]},{"term_id":85,"name":"spectrometer","slug":"spectrometer","term_group":0,"term_taxonomy_id":85,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":159,"name":"sulfide ores","slug":"sulfide-ores","term_group":0,"term_taxonomy_id":159,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":1033,"position":0},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":1033,"position":1},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":1033,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":1033,"position":3},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":1033,"position":4},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1624,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/a-halloween-treat-free-periodic-table\/","url_meta":{"origin":1033,"position":5},"title":"A Halloween Treat &#8211; Free Periodic Table","author":"Marlene Gasdia-Cochrane","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your mining samples. \u00a0It's our treat. Then visit our Mining and Minerals, Cement Production, and Coal Power pages for more goodies. Download Periodic Table.\u00a0 \u00a0","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"halloween scene with plastic pumpkin and candy","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2013\/08\/sulfides1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/1033","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/42"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=1033"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/1033\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/1030"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=1033"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=1033"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=1033"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=1033"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}