{"id":10855,"date":"2018-08-14T12:00:33","date_gmt":"2018-08-14T12:00:33","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/mining\/?p=10855"},"modified":"2026-01-06T20:45:56","modified_gmt":"2026-01-06T20:45:56","slug":"performance-optimization-for-online-cement-analyzers","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/","title":{"rendered":"Performance Optimization for Online Cement Analyzers"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right;border: 0;margin: 10px\" title=\"cement production\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg\" alt=\"cement production\" width=\"450\" height=\"300\" \/>Cement plants strive for consistent material quality with minimal chemistry deviation, whether it\u2019s confirming the quality of the incoming raw material, or ensuring the final cement product meets customer specifications.\u00a0 <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/CBOMNIFUSION?icid=CAD_blog_mining_2018July\">Online elemental cement analyzers<\/a> perform real-time quality control for process optimization. \u00a0By having your online analyzer operating at peak accuracy, the kiln feed will be more consistent, which can lead to greater throughput, fewer BTUs of coal burned per ton of clinker, less electrical cost per ton of clinker and longer brick life.<\/p>\n<p>However, how can you ensure the analyzer is working at optimal performance?<\/p>\n<p>There are innovative <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/ACCULINK?icid=CAD_blog_mining_2018July\">software tools<\/a> for your cement analyzers that provide continuous comparisons with the lab and timely, automatic calibrations. Software can link your XRF laboratory analyzers with online <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-coal-minerals-learning-center\/cement-analysis-production-information\/pgnaa-pftna-technology.html?icid=CAD_blog_mining_2018July\" target=\"_blank\" rel=\"noopener noreferrer\">PGNAA<\/a> elemental cement analyzers and automatically compare data from both systems to ensure peak operational efficiency. It can then compare the results of your <a href=\"http:\/\/bit.ly\/2KiNmfy\" target=\"_blank\" rel=\"noopener noreferrer\">online crossbelt analyzer <\/a>with the site laboratory and provide both a statistical and graphical data analysis, which reduces the time you would have to spend in reviewing analyzer performance.<\/p>\n<p>What types of data can help ensure your analyzers are properly calibrated and are at optimal performance?\u00a0 Here are items that should be watched on a regular basis:<\/p>\n<ul>\n<li>A three-month Bias summary that shows a pair of plots for each of the main quality control parameters (e.g., LSF, silica ratio) and\/or individual oxides (e.g., MgO, CaO). One plot can show the hourly lab vs. analyzer trends for the most recent two to three days, while the second plot can show the bar chart of the average bias between the lab and the analyzer, where each bar represents a calibration period, for the past three months.<\/li>\n<li>A three-month Root Mean Square Deviation (RMSD) summary for quality control with a bar chart of the RMSD for the main quality control parameters of interest.<\/li>\n<li>A three-month bar chart of Root Mean Square Deviation (RMSD) for the main oxides, and an oxide calibration summary that includes two plots (a scatter plot of lab vs. analyzer values for each detector, and a trend plot of the same data, both shown from the chosen calibration interval).<\/li>\n<li>A calibration overview with current calibration constants in use for each detector, along with an indication of any oxide\/detector pair which appears to merit a recalibration at the next calibration interval.<\/li>\n<li>An XRF lab analysis database and an analyzer calibration history trend plot.<\/li>\n<\/ul>\n<p>Your online analysis system is a big investment so you want to make sure it is operating efficiently and accurately.\u00a0 Using available software that provides rigorous, statistical analysis and subsequent automatic implementation of calibrations into your online analyzer system helps facilitate the diagnosis of process-related analysis questions, and help improve your bottom line.<\/p>\n<p><em>For more details, download the Product Specification Sheet: <\/em><a href=\"https:\/\/assets.thermofisher.com\/TFS-Assets\/CAD\/Specification-Sheets\/D20440~.pdf?icid=CAD_blog_mining_2018July\"><em>Performance Optimization Software<\/em><\/a><\/p>\n<h2>Visit the<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?cid=cad_cad_vm_cement_sig_blog\"> Cement Production center<\/a> on our website, with free resources to help you optimize your cement making process.<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?cid=cad_cad_vm_cement_sig_blog\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-11424\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125.jpg\" alt=\"\" width=\"600\" height=\"125\" srcset=\"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125.jpg 600w, https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125-300x63.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>Cement plants strive for consistent material quality with minimal chemistry deviation, whether it\u2019s confirming the quality of the incoming raw material, or ensuring the final cement product meets customer specifications.\u00a0 Online elemental cement analyzers perform real-time quality control for process optimization. \u00a0By having your online analyzer operating at peak accuracy, the kiln feed will be<\/p>\n","protected":false},"author":142,"featured_media":10948,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[6,36,10,38],"tags":[],"division":[],"class_list":["post-10855","post","type-post","status-publish","format-standard","has-post-thumbnail","category-elemental-geochemical-analysis","category-material-handling","category-mineral-processing","category-weighing-and-monitoring","entry"],"_selected_authors":[1211],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Performance Optimization for Online Cement Analyzers<\/title>\n<meta name=\"description\" content=\"How to keep your online cement analyzers operating efficiently and accurately.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Performance Optimization for Online Cement Analyzers\" \/>\n<meta property=\"og:description\" content=\"How to keep your online cement analyzers operating efficiently and accurately.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2018-08-14T12:00:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-06T20:45:56+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"724\" \/>\n\t<meta property=\"og:image:height\" content=\"483\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Darrell Leetham\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Darrell Leetham\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/\"},\"author\":{\"name\":\"Darrell Leetham\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/f0781ecc750e508d9b6e7d9d3c0e9571\"},\"headline\":\"Performance Optimization for Online Cement Analyzers\",\"datePublished\":\"2018-08-14T12:00:33+00:00\",\"dateModified\":\"2026-01-06T20:45:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/\"},\"wordCount\":494,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/istock-149000918_cementplant-1.jpg\",\"articleSection\":[\"Elemental\\\/Geochemical Analysis\",\"Material Handling\",\"Mineral Processing\",\"Weighing and Monitoring\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/\",\"name\":\"Performance Optimization for Online Cement Analyzers\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/istock-149000918_cementplant-1.jpg\",\"datePublished\":\"2018-08-14T12:00:33+00:00\",\"dateModified\":\"2026-01-06T20:45:56+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/f0781ecc750e508d9b6e7d9d3c0e9571\"},\"description\":\"How to keep your online cement analyzers operating efficiently and accurately.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/istock-149000918_cementplant-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2018\\\/08\\\/istock-149000918_cementplant-1.jpg\",\"width\":724,\"height\":483,\"caption\":\"cement production\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/performance-optimization-for-online-cement-analyzers\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Performance Optimization for Online Cement Analyzers\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/f0781ecc750e508d9b6e7d9d3c0e9571\",\"name\":\"Darrell Leetham\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g\",\"caption\":\"Darrell Leetham\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/darrell-leethamthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Performance Optimization for Online Cement Analyzers","description":"How to keep your online cement analyzers operating efficiently and accurately.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/","og_locale":"en_US","og_type":"article","og_title":"Performance Optimization for Online Cement Analyzers","og_description":"How to keep your online cement analyzers operating efficiently and accurately.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2018-08-14T12:00:33+00:00","article_modified_time":"2026-01-06T20:45:56+00:00","og_image":[{"width":724,"height":483,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg","type":"image\/jpeg"}],"author":"Darrell Leetham","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Darrell Leetham","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/"},"author":{"name":"Darrell Leetham","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/f0781ecc750e508d9b6e7d9d3c0e9571"},"headline":"Performance Optimization for Online Cement Analyzers","datePublished":"2018-08-14T12:00:33+00:00","dateModified":"2026-01-06T20:45:56+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/"},"wordCount":494,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg","articleSection":["Elemental\/Geochemical Analysis","Material Handling","Mineral Processing","Weighing and Monitoring"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/","name":"Performance Optimization for Online Cement Analyzers","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg","datePublished":"2018-08-14T12:00:33+00:00","dateModified":"2026-01-06T20:45:56+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/f0781ecc750e508d9b6e7d9d3c0e9571"},"description":"How to keep your online cement analyzers operating efficiently and accurately.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg","width":724,"height":483,"caption":"cement production"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/performance-optimization-for-online-cement-analyzers\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Performance Optimization for Online Cement Analyzers"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/f0781ecc750e508d9b6e7d9d3c0e9571","name":"Darrell Leetham","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g","caption":"Darrell Leetham"},"url":"https:\/\/admin.acceleratingscience.com\/author\/darrell-leethamthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":6,"label":"Elemental\/Geochemical Analysis"},{"value":36,"label":"Material Handling"},{"value":10,"label":"Mineral Processing"},{"value":38,"label":"Weighing and Monitoring"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg",724,483,false],"author_info":{"display_name":"Darrell Leetham","author_link":"https:\/\/admin.acceleratingscience.com\/author\/darrell-leethamthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":6,"name":"Elemental\/Geochemical Analysis","slug":"elemental-geochemical-analysis","term_group":0,"term_taxonomy_id":6,"taxonomy":"category","description":"","parent":0,"count":144,"filter":"raw","meta":[],"cat_ID":6,"category_count":144,"category_description":"","cat_name":"Elemental\/Geochemical Analysis","category_nicename":"elemental-geochemical-analysis","category_parent":0},{"term_id":36,"name":"Material Handling","slug":"material-handling","term_group":0,"term_taxonomy_id":36,"taxonomy":"category","description":"","parent":0,"count":56,"filter":"raw","meta":[],"cat_ID":36,"category_count":56,"category_description":"","cat_name":"Material Handling","category_nicename":"material-handling","category_parent":0},{"term_id":10,"name":"Mineral Processing","slug":"mineral-processing","term_group":0,"term_taxonomy_id":10,"taxonomy":"category","description":"","parent":0,"count":66,"filter":"raw","meta":[],"cat_ID":10,"category_count":66,"category_description":"","cat_name":"Mineral Processing","category_nicename":"mineral-processing","category_parent":0},{"term_id":38,"name":"Weighing and Monitoring","slug":"weighing-and-monitoring","term_group":0,"term_taxonomy_id":38,"taxonomy":"category","description":"","parent":0,"count":32,"filter":"raw","meta":[],"cat_ID":38,"category_count":32,"category_description":"","cat_name":"Weighing and Monitoring","category_nicename":"weighing-and-monitoring","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":10855,"position":0},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":10855,"position":1},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14089,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-real-time-monitoring-is-transforming-refined-fuel-quality-control\/","url_meta":{"origin":10855,"position":2},"title":"Why Real-Time Monitoring Is Transforming Refined Fuel Quality Control","author":"Marlene Gasdia-Cochrane","date":"July 21, 2026","format":false,"excerpt":"Article Summary Refinery operations depend on precise control of fuel properties. Whether producing gasoline, diesel, jet fuel, or base oils, even small variations can impact product performance, regulatory compliance, and profitability. Traditionally, fuel quality has been verified through a combination of laboratory testing and online analyzers. While these methods are\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Aerial view of oil refinery and storage tanks at dusk and night, showcasing energy industry infrastructure, petroleum processing, and industrial landscape.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14123,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-coal-chemistry-matters-in-coal-fired-power-generation\/","url_meta":{"origin":10855,"position":3},"title":"Why Coal Chemistry Matters in Coal-Fired Power Generation\u00a0","author":"Marlene Gasdia-Cochrane","date":"July 28, 2026","format":false,"excerpt":"Summary For coal manufacturers, product quality extends far beyond tonnage and\u00a0logistics. The chemical characteristics of coal directly influence power plant efficiency, emissions performance, maintenance requirements, and overall operating costs. As utilities continue to focus on fuel optimization and regulatory compliance, understanding coal chemistry has become essential for suppliers\u00a0seeking\u00a0to deliver value\u2026","rel":"","context":"In &quot;Coal&quot;","block_context":{"text":"Coal","link":"https:\/\/admin.acceleratingscience.com\/mining\/coal\/"},"img":{"alt_text":"Stone coal lump in scientist hand","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14189,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url_meta":{"origin":10855,"position":4},"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","author":"Marlene Gasdia-Cochrane","date":"November 3, 2026","format":false,"excerpt":"Article Summary Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, mining operations increasingly need to process lower-grade ores with more variable chemical compositions. Handheld X-ray fluorescence (XRF) provides a fast,\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"An aerial view of an open pit phosphate mine","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":10855,"position":5},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2018\/08\/istock-149000918_cementplant-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/10855","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=10855"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/10855\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/10948"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=10855"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=10855"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=10855"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=10855"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}