
{"id":11961,"date":"2020-07-14T12:00:32","date_gmt":"2020-07-14T12:00:32","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/mining\/?p=11961"},"modified":"2026-01-13T21:30:32","modified_gmt":"2026-01-13T21:30:32","slug":"how-to-optimize-coal-fired-power-plants","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/","title":{"rendered":"How to Optimize Coal-Fired Power Plants"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/www.thermofisher.com\/blog\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg\" style=\"float: right;border: 0;margin: 10px\" alt=\"How to Optimize Coal-Fired Power Plants\" title=\"How to Optimize Coal-Fired Power Plants\" width=\"450\" height=\"257\" class=\"alignright\" \/>The <a href=\"https:\/\/www.iea.org\/reports\/tracking-power-2020\/coal-fired-power#abstract\">International Energy Agency<\/a> recently reported that after three years of increase, coal-based generation dropped 3% in 2019 as electricity demand growth slowed. However, &ldquo;It remains the primary energy source for electricity generation worldwide&hellip;with a share of 36% due to its widespread use in Asian economies&hellip; Making the existing coal power plant fleet more flexible and efficient is a priority.&rdquo;<\/p>\n<p>According to the <a href=\"https:\/\/www.eia.gov\/todayinenergy\/detail.php?id=43675\">U.S. Energy Information Administration<\/a>, &ldquo;Although coal at U.S. power plants has cost less than natural gas, for coal to be competitive, its delivered cost must be at least 30% lower to make up for the differences in efficiency between a typical coal-fired plant and a typical natural gas-fired plant. These differences are even larger for more efficient natural gas-fired combined-cycle plants. Coal plants must also offset higher costs for emission control equipment and other operations.&rdquo;<\/p>\n<p>As a result of these factors, globally, the <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/coal-fired-power-plant-generation.html?icid=CAD_blog_mining_2020July\">coal-fired power plant<\/a> faces the increasing demands of cost saving, process optimization, and cleaner gas emission. The good news is that there is already technology that can help optimize raw material handling, analyze coal quality, monitor emissions and air quality, and assess the structural integrity of pipelines.<span>&nbsp; <\/span><\/p>\n<p>Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants:<\/p>\n<ul>\n<li><span><span><span><\/span><\/span><\/span><strong>Raw Material Handling:<\/strong> There is raw material handling equipment for each stage of the process, including belt scale systems to monitor the weight of goods received, tramp metal detectors to protect the crusher and other expensive equipment, and conveyor protection switches to stop the conveyor if any unexpected accident happens. There are also specialty process control instruments to ensure precise feeding of process materials, control inventory, and maintain product quality. Learn more about <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/coal-fired-power-plant-generation\/coal-raw-material-handling.html?icid=CAD_blog_mining_2020July\">raw material handling equipment<\/a>. <\/li>\n<li><span><span><span><\/span><\/span><\/span><strong>Online Coal Quality Analysis:<\/strong><span>&nbsp; <\/span>Online elemental coal analyzers and blending software measure the composition of coal in real-time and proactively address process variations to ensure more consistent coal blends. The latest analyzers use either Prompt Gamma Neutron Activation (PGNAA) or Pulsed Fast Thermal Neutron Activation (PFTNA) technology to help provide coal producers with accurate, reliable data to control coal blends and ensure on-spec batches. <span>&nbsp;<\/span>Learn more about&nbsp;<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/coal-mining-coal-power-generation.html?icid=CAD_blog_mining_2020July\">online coal quality analysis<\/a> products. <\/li>\n<li><span><span><span><\/span><\/span><\/span><strong>Positive Material Identification:<\/strong> The structural integrity of pipelines and plant assets is key for safety. Material mix-ups in metal production can have profound effects on the final product, so today&rsquo;s best practice is to analyze 100% of critical materials. Using handheld XRF and LIBS analyzers, operators can perform positive material identification (PMI) to analyze piping material and get results in minutes to ensure that no incorrect or out of specification metal alloys enter the manufacturing process. Learn more about <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-metal-manufacturing-inspection-recycling-solutions\/positive-material-identification-oil-gas.html?icid=CAD_blog_mining_2020July\">handheld instruments for PMI<\/a>. <\/li>\n<li><span><span><span><\/span><\/span><\/span><strong>Continuous Emissions Monitoring Systems:<\/strong> There are a variety of products help customers with regulatory compliance and process control. Some specialty Continuous Emissions Monitoring Systems (CEMS) include Particulate Matter (PM) CEMS and Mercury (Hg) CEMS. These probes are installed in stack and transfer gas to PM and Hg analyzers in the shelter, helping customers to comply with local PM and Hg emission regulation and optimal process performance. Learn more about <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/environmental\/air-quality-analysis\/source-gas-monitoring-emissions-monitoring\/continuous-emissions-monitoring-systems.html?icid=CAD_blog_mining_2020July\">Continuous Emissions Monitoring Systems<\/a>.  <\/li>\n<li><span><span><span><\/span><\/span><\/span><strong>Air Quality Monitoring Systems: <\/strong>Air quality monitoring systems measure air quality, low and high levels of criteria pollutants, as well as other gases and toxins. These instruments help ensure ambient air quality complies with local environmental regulations (SOx, NOx, CO, Ozone, PM 2.5\/ PM10). Learn more about <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/environmental\/air-quality-analysis\/ambient-gas-monitoring.html\">ambient gas monitors<\/a>.<\/li>\n<\/ul>\n<p>You can even see how all these instruments fit into the basic workflow of a power generation plant. Visit our website and access the interactive app: <a href=\"http:\/\/apps.thermoscientific.com\/media\/CAD\/CFPP\/index.html?icid=CAD_blog_mining_2020July\">Coal-fired Power Plant Interactive Workflow<\/a>.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The International Energy Agency recently reported that after three years of increase, coal-based generation dropped 3% in 2019 as electricity demand growth slowed. However, &ldquo;It remains the primary energy source for electricity generation worldwide&hellip;with a share of 36% due to its widespread use in Asian economies&hellip; Making the existing coal power plant fleet more flexible<\/p>\n","protected":false},"author":788,"featured_media":11971,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[9],"tags":[],"division":[],"class_list":{"0":"post-11961","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-coal","8":"entry"},"_selected_authors":[1230],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>How to Optimize Coal-Fired Power Plants<\/title>\n<meta name=\"description\" content=\"Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Optimize Coal-Fired Power Plants\" \/>\n<meta property=\"og:description\" content=\"Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-07-14T12:00:32+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T21:30:32+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"782\" \/>\n\t<meta property=\"og:image:height\" content=\"446\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chien-Chin Chuang\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chien-Chin Chuang\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/\"},\"author\":{\"name\":\"Chien-Chin Chuang\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/46a428c53f3fa6d5d259552b757d0d34\"},\"headline\":\"How to Optimize Coal-Fired Power Plants\",\"datePublished\":\"2020-07-14T12:00:32+00:00\",\"dateModified\":\"2026-01-13T21:30:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/\"},\"wordCount\":619,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2020\\\/07\\\/istock-522622526_coalpowerplant.jpg\",\"articleSection\":[\"Coal\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/\",\"name\":\"How to Optimize Coal-Fired Power Plants\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2020\\\/07\\\/istock-522622526_coalpowerplant.jpg\",\"datePublished\":\"2020-07-14T12:00:32+00:00\",\"dateModified\":\"2026-01-13T21:30:32+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/46a428c53f3fa6d5d259552b757d0d34\"},\"description\":\"Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2020\\\/07\\\/istock-522622526_coalpowerplant.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2020\\\/07\\\/istock-522622526_coalpowerplant.jpg\",\"width\":782,\"height\":446,\"caption\":\"How to Optimize Coal-Fired Power Plants\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/how-to-optimize-coal-fired-power-plants\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Optimize Coal-Fired Power Plants\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/46a428c53f3fa6d5d259552b757d0d34\",\"name\":\"Chien-Chin Chuang\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/23c044aa87ab0357cd9333e328776f282f5d68187af2c49620f1cde0521d3e17?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/23c044aa87ab0357cd9333e328776f282f5d68187af2c49620f1cde0521d3e17?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/23c044aa87ab0357cd9333e328776f282f5d68187af2c49620f1cde0521d3e17?s=96&d=mm&r=g\",\"caption\":\"Chien-Chin Chuang\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/chienchin\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"How to Optimize Coal-Fired Power Plants","description":"Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/","og_locale":"en_US","og_type":"article","og_title":"How to Optimize Coal-Fired Power Plants","og_description":"Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-07-14T12:00:32+00:00","article_modified_time":"2026-01-13T21:30:32+00:00","og_image":[{"width":782,"height":446,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg","type":"image\/jpeg"}],"author":"Chien-Chin Chuang","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Chien-Chin Chuang","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/"},"author":{"name":"Chien-Chin Chuang","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/46a428c53f3fa6d5d259552b757d0d34"},"headline":"How to Optimize Coal-Fired Power Plants","datePublished":"2020-07-14T12:00:32+00:00","dateModified":"2026-01-13T21:30:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/"},"wordCount":619,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg","articleSection":["Coal"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/","name":"How to Optimize Coal-Fired Power Plants","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg","datePublished":"2020-07-14T12:00:32+00:00","dateModified":"2026-01-13T21:30:32+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/46a428c53f3fa6d5d259552b757d0d34"},"description":"Here are some of the technologies that coal-fired power generation operators could invest in if they are to reduce costs and optimize their plants.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg","width":782,"height":446,"caption":"How to Optimize Coal-Fired Power Plants"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/how-to-optimize-coal-fired-power-plants\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"How to Optimize Coal-Fired Power Plants"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/46a428c53f3fa6d5d259552b757d0d34","name":"Chien-Chin Chuang","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/23c044aa87ab0357cd9333e328776f282f5d68187af2c49620f1cde0521d3e17?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/23c044aa87ab0357cd9333e328776f282f5d68187af2c49620f1cde0521d3e17?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/23c044aa87ab0357cd9333e328776f282f5d68187af2c49620f1cde0521d3e17?s=96&d=mm&r=g","caption":"Chien-Chin Chuang"},"url":"https:\/\/admin.acceleratingscience.com\/author\/chienchin\/"}]}},"taxonomy_info":{"category":[{"value":9,"label":"Coal"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg",760,433,false],"author_info":{"display_name":"Chien-Chin Chuang","author_link":"https:\/\/admin.acceleratingscience.com\/author\/chienchin\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Coal","slug":"coal","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":78,"filter":"raw","meta":[],"cat_ID":9,"category_count":78,"category_description":"","cat_name":"Coal","category_nicename":"coal","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":14123,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-coal-chemistry-matters-in-coal-fired-power-generation\/","url_meta":{"origin":11961,"position":0},"title":"Why Coal Chemistry Matters in Coal-Fired Power Generation\u00a0","author":"Marlene Gasdia-Cochrane","date":"July 28, 2026","format":false,"excerpt":"Summary For coal manufacturers, product quality extends far beyond tonnage and\u00a0logistics. The chemical characteristics of coal directly influence power plant efficiency, emissions performance, maintenance requirements, and overall operating costs. As utilities continue to focus on fuel optimization and regulatory compliance, understanding coal chemistry has become essential for suppliers\u00a0seeking\u00a0to deliver value\u2026","rel":"","context":"In &quot;Coal&quot;","block_context":{"text":"Coal","link":"https:\/\/admin.acceleratingscience.com\/mining\/coal\/"},"img":{"alt_text":"Stone coal lump in scientist hand","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1624,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/a-halloween-treat-free-periodic-table\/","url_meta":{"origin":11961,"position":1},"title":"A Halloween Treat &#8211; Free Periodic Table","author":"Marlene Gasdia-Cochrane","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your mining samples. \u00a0It's our treat. Then visit our Mining and Minerals, Cement Production, and Coal Power pages for more goodies. Download Periodic Table.\u00a0 \u00a0","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"halloween scene with plastic pumpkin and candy","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":11961,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":11961,"position":3},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":11961,"position":4},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":11961,"position":5},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2020\/07\/istock-522622526_coalpowerplant.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/11961","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/788"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=11961"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/11961\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/11971"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=11961"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=11961"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=11961"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=11961"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}