
{"id":14189,"date":"2026-11-03T08:00:00","date_gmt":"2026-11-03T08:00:00","guid":{"rendered":"https:\/\/www.thermofisher.com\/blog\/mining\/?p=14189"},"modified":"2026-10-30T19:48:50","modified_gmt":"2026-10-30T19:48:50","slug":"understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","title":{"rendered":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition"},"content":{"rendered":"\n<div class=\"wp-block-tf-blocks-intro-summary\">\n<h2 class=\"wp-block-heading\" id=\"h-article-summary\">Article Summary<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals.html?cid=fl-mining\" target=\"_blank\" rel=\"noreferrer noopener\">mining<\/a> operations increasingly need to process lower-grade ores with more variable chemical compositions. <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/spectroscopy-elemental-isotope-analysis-learning-center\/elemental-analysis-information\/xrf-technology\/xrf-technology.html?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">Handheld X-ray fluorescenc<\/a>e (XRF) provides a fast, non-destructive method for measuring multiple elements directly at mining and production sites. When combined with proper sample preparation, a <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/NITONXL5PLUS?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">handheld XRF analyzer<\/a> can help mining teams rapidly evaluate ore quality, identify potentially problematic elements, and make more informed operational decisions.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-definition-block\">\n<h2 class=\"wp-block-heading\" id=\"h-why-is-rapid-phosphate-ore-analysis-important\">Why Is Rapid Phosphate Ore Analysis Important?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Phosphate deposits can vary substantially in both mineral composition and chemistry. The primary phosphate mineral is apatite, but phosphate ores can also contain silica, carbonates, aluminum-bearing minerals, iron oxides, magnesium, sodium, potassium, sulfur, chlorine, and various trace elements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Understanding this elemental composition is important throughout phosphate <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals\/solutions.html?icid=CAD_blog_mining_2026Nov#exploration\" target=\"_blank\" rel=\"noreferrer noopener\">exploration<\/a>, extraction, processing, and fertilizer production.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Two trace elements deserve particular attention: cadmium (Cd) and uranium (U). These are often considered penalty elements because elevated concentrations can create environmental, regulatory, processing, and product-quality concerns. Their presence may reduce the marketability of phosphate materials in markets with strict limits, while removing unwanted elements can increase processing costs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Rapid elemental analysis therefore gives mining operations information that can support grade control, process optimization, environmental monitoring, and ore management.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Does Handheld XRF Analyze Phosphate Ore?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/spectroscopy-elemental-isotope-analysis-learning-center\/elemental-analysis-information\/xrf-technology\/xrf-technology.html\" target=\"_blank\" rel=\"noreferrer noopener\">Handheld XRF<\/a> uses X-rays to excite atoms within a sample. The resulting X-ray fluorescence provides information about the elements present and their concentrations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For phosphate mining, this technology has an important practical advantage: multi-element measurements can be performed directly in the field or at the production site without waiting for conventional laboratory turnaround. Results can support decisions involving exploration, extraction, stockpile management, quality control, and environmental monitoring.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Handheld XRF should not be viewed as a universal replacement for laboratory certification. Instead, it provides rapid compositional information that can complement laboratory testing and help teams make faster decisions between formal laboratory analyses.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Direct Rock Testing vs. Prepared Samples<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">There are two primary approaches to handheld XRF analysis of phosphate ores.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The first is direct testing of an exposed rock surface, sometimes called <strong>point-and-shoot analysis<\/strong>. This approach is useful when speed is the priority, such as rapidly locating areas containing higher-grade material. However, measurements taken directly from heterogeneous rock surfaces generally provide lower accuracy and analytical sensitivity than properly prepared samples.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The second approach involves <strong>sample preparation<\/strong>. Material is collected, ground, and homogenized to create a representative powder. Samples with high moisture levels may also need to be dried before grinding. The prepared powder can then be placed into a sample cup for analysis.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This additional preparation improves measurement consistency and enables longer analyses, producing results that can be more comparable with laboratory methods.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Why Sample Preparation Matters for XRF Accuracy<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A phosphate rock is rarely chemically uniform. Measuring only one location on an unprepared sample can therefore produce a result that does not adequately represent the bulk material.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Grinding and homogenizing the material reduces this variability. Proper preparation becomes particularly important when the objective is quantitative analysis or the detection of impurities at relatively low concentrations.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In a <a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/field-analysis-of-phosphate-ores-an1912-en.pdf?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">reported study<\/a>, nine finely ground certified phosphate reference materials were analyzed. Approximately eight grams of each material were placed in sample cups, and each sample was measured for a total of 120 seconds using four analytical conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">This methodology was designed to evaluate how closely field-capable XRF measurements could agree with certified reference concentrations.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Accurate Is Handheld XRF for Phosphate Ore?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The study reported strong agreement between handheld XRF measurements and certified values for three important major elements: phosphorus (P), calcium (Ca), and silicon (Si) and one penalty element (U).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The reported coefficients of determination (R\u00b2) were approximately:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Phosphorus:<\/strong> 0.9965<\/li>\n\n\n\n<li><strong>Calcium:<\/strong> 0.9995<\/li>\n\n\n\n<li><strong>Silicon:<\/strong> 0.9914<\/li>\n\n\n\n<li><strong>Uranium:<\/strong> 0.9981<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">An R\u00b2 value closer to 1 indicates stronger agreement between measured and certified concentrations. These results therefore demonstrate a strong correlation across the certified materials evaluated in the study.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Importantly, uranium was successfully evaluated at relatively low concentrations, with certified reference concentrations extending down to approximately 20 parts per million (ppm). Cadmium was also detected in most of the samples, although certified cadmium concentrations were available for only a limited portion of the sample set.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">How Can Rapid XRF Analysis Improve Phosphate Mining?<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Fast phosphate ore analysis can shorten the time between sampling and operational decision-making. Instead of relying exclusively on delayed laboratory results, field teams can obtain immediate information that helps them determine where additional sampling or laboratory analysis may be warranted.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Potential applications include exploration screening, ore-grade assessment, extraction guidance, stockpile management, process control, quality monitoring, and screening for penalty elements.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The distinction between <strong>screening <\/strong>and <strong>certification<\/strong> remains important. Direct field measurements prioritize speed, while prepared-sample measurements can provide greater accuracy. Laboratory methods remain necessary when formal certification or other definitive analytical results are required.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-takeaway-summary\">\n<h2 class=\"wp-block-heading\" id=\"h-conclusion\">Conclusion<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Handheld XRF provides a practical method for rapid, multi-element phosphate ore analysis at or near the point of operation. The study demonstrates strong agreement between properly prepared XRF measurements and certified reference values for phosphorus, calcium, silicon, and uranium, while also demonstrating the ability to detect cadmium in phosphate materials.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">For phosphate <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals.html?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">mining<\/a> operations facing increasingly variable ore bodies, combining rapid field screening with appropriate sample preparation and laboratory confirmation can create a more efficient analytical workflow. This approach can support faster ore characterization, improved process control, better management of penalty elements, and more informed decisions throughout phosphate exploration and production.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-tf-blocks-internal-links\">\n<p class=\"wp-block-paragraph\"><em>Further Reading<\/em><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Application Note: <em>Rapid, accurate field analysis of phosphate ores with handheld XRF<\/em>: <a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/field-analysis-of-phosphate-ores-an1912-en.pdf?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/documents.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/field-analysis-of-phosphate-ores-an1912-en.pdf?icid=CAD_blog_mining_2026Nov<\/a><\/li>\n\n\n\n<li>Ebook: <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/ebook-mining-mineral-operations-registration-form.html?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">A Practical Guide to Improving Mining and Mineral Operations<\/a><\/li>\n\n\n\n<li>Ebook: <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals\/resources.html?icid=CAD_blog_mining_2026Nov\" target=\"_blank\" rel=\"noreferrer noopener\">XRF Technology for Non-Scientists<\/a><\/li>\n<\/ul>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-frequently-asked-questions\">Frequently Asked Questions<\/h2>\n\n\n<style>.kt-accordion-id14189_d81a0e-18 .kt-accordion-inner-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:10px;}.kt-accordion-id14189_d81a0e-18 .kt-accordion-panel-inner{border-top:0px solid transparent;border-right:1px solid transparent;border-bottom:1px solid transparent;border-left:1px solid transparent;background:#ffffff;padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-right:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);padding-left:var(--global-kb-spacing-sm, 1.5rem);}.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header{border-top:1px solid #eeeeee;border-right:1px solid #eeeeee;border-bottom:1px solid #eeeeee;border-left:2px solid #eeeeee;border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;background:#ffffff;color:#444444;padding-top:14px;padding-right:16px;padding-bottom:14px;padding-left:16px;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap .kt-blocks-accordion-icon-trigger:before{background:#444444;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-icon-trigger{background:#444444;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-icon-trigger:before{background:#ffffff;}.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header:hover, \n\t\t\t\tbody:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18 .kt-blocks-accordion-header:focus-visible{color:#444444;background:#ffffff;border-top-color:#878787;border-right-color:#878787;border-bottom-color:#878787;border-left-color:#878787;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:before, body:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-blocks-accordion--visible .kt-blocks-accordion-icon-trigger:after, body:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle ) .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger:before{background:#444444;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger, body:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger{background:#444444;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:hover .kt-blocks-accordion-icon-trigger:before, body:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger:after, body:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible .kt-blocks-accordion-icon-trigger:before{background:#ffffff;}.kt-accordion-id14189_d81a0e-18 .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible,\n\t\t\t\t.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active{color:#444444;background:#ffffff;border-top-color:#eeeeee;border-right-color:#eeeeee;border-bottom-color:#eeeeee;border-left-color:#0e9cd1;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basiccircle ):not( .kt-accodion-icon-style-xclosecircle ):not( .kt-accodion-icon-style-arrowcircle )  > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:before{background:#444444;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger{background:#444444;}.kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:after, .kt-accordion-id14189_d81a0e-18:not( .kt-accodion-icon-style-basic ):not( .kt-accodion-icon-style-xclose ):not( .kt-accodion-icon-style-arrow ) .kt-blocks-accordion-header.kt-accordion-panel-active .kt-blocks-accordion-icon-trigger:before{background:#ffffff;}@media all and (max-width: 1024px){.kt-accordion-id14189_d81a0e-18 .kt-accordion-panel-inner{border-top:0px solid transparent;border-right:1px solid transparent;border-bottom:1px solid transparent;border-left:1px solid transparent;}}@media all and (max-width: 1024px){.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header{border-top:1px solid #eeeeee;border-right:1px solid #eeeeee;border-bottom:1px solid #eeeeee;border-left:2px solid #eeeeee;}}@media all and (max-width: 1024px){.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header:hover, \n\t\t\t\tbody:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18 .kt-blocks-accordion-header:focus-visible{border-top-color:#878787;border-right-color:#878787;border-bottom-color:#878787;border-left-color:#878787;}}@media all and (max-width: 1024px){.kt-accordion-id14189_d81a0e-18 .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible,\n\t\t\t\t.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active{border-top-color:#eeeeee;border-right-color:#eeeeee;border-bottom-color:#eeeeee;border-left-color:#0e9cd1;}}@media all and (max-width: 767px){.kt-accordion-id14189_d81a0e-18 .kt-accordion-inner-wrap{display:block;}.kt-accordion-id14189_d81a0e-18 .kt-accordion-inner-wrap .kt-accordion-pane:not(:first-child){margin-top:10px;}.kt-accordion-id14189_d81a0e-18 .kt-accordion-panel-inner{border-top:0px solid transparent;border-right:1px solid transparent;border-bottom:1px solid transparent;border-left:1px solid transparent;}.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header{border-top:1px solid #eeeeee;border-right:1px solid #eeeeee;border-bottom:1px solid #eeeeee;border-left:2px solid #eeeeee;}.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header:hover, \n\t\t\t\tbody:not(.hide-focus-outline) .kt-accordion-id14189_d81a0e-18 .kt-blocks-accordion-header:focus-visible{border-top-color:#878787;border-right-color:#878787;border-bottom-color:#878787;border-left-color:#878787;}.kt-accordion-id14189_d81a0e-18 .kt-accordion-header-wrap .kt-blocks-accordion-header:focus-visible,\n\t\t\t\t.kt-accordion-id14189_d81a0e-18 > .kt-accordion-inner-wrap > .wp-block-kadence-pane > .kt-accordion-header-wrap > .kt-blocks-accordion-header.kt-accordion-panel-active{border-top-color:#eeeeee;border-right-color:#eeeeee;border-bottom-color:#eeeeee;border-left-color:#0e9cd1;}}<\/style>\n<div class=\"wp-block-kadence-accordion alignnone\"><div class=\"kt-accordion-wrap kt-accordion-id14189_d81a0e-18 kt-accordion-has-5-panes kt-active-pane-0 kt-accordion-block kt-pane-header-alignment-left kt-accodion-icon-style-arrow kt-accodion-icon-side-right\" style=\"max-width:none\"><div class=\"kt-accordion-inner-wrap\" data-allow-multiple-open=\"false\" data-start-open=\"0\">\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-1 kt-pane14189_7cd2e8-da\"><h2 class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\"><strong>What is handheld XRF used for in phosphate mining?<\/strong><\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/h2><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<ul class=\"wp-block-list\">\n<li>Handheld XRF is used for rapid elemental analysis of phosphate ores. Applications include exploration screening, grade control, stockpile management, process monitoring, and quantifying elements such as phosphorus, calcium, silicon, uranium, and cadmium.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-2 kt-pane14189_468fc2-8c\"><h2 class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\"><strong>Can handheld XRF measure phosphorus in phosphate rock?<\/strong><\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/h2><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<ul class=\"wp-block-list\">\n<li>Yes. A <a href=\"https:\/\/documents.thermofisher.com\/TFS-Assets\/CAD\/Application-Notes\/field-analysis-of-phosphate-ores-an1912-en.pdf?icid=CAD_blog_mining_2026Nov\">study<\/a> found strong agreement between handheld XRF measurements and certified phosphorus concentrations in prepared phosphate reference materials, with a reported R\u00b2 of 0.9965.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-3 kt-pane14189_3c2b49-ac\"><h2 class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\"><strong><strong>Why should phosphate samples be ground before XRF analysis?<\/strong><\/strong><\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/h2><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<ul class=\"wp-block-list\">\n<li>Grinding and homogenization make the sample more representative and reduce variations caused by an uneven rock surface or mineral distribution. This can improve accuracy and sensitivity of elemental determination.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-4 kt-pane14189_4ec070-6c\"><h2 class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\"><strong><strong><strong>Can handheld XRF detect uranium and cadmium in phosphate ore?<\/strong><\/strong><\/strong><\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/h2><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<ul class=\"wp-block-list\">\n<li>Yes. The study demonstrated accurate uranium measurement in reference samples containing concentrations down to about 20 ppm and detected cadmium in most samples tested.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n\n\n\n<div class=\"wp-block-kadence-pane kt-accordion-pane kt-accordion-pane-5 kt-pane14189_5f0d15-90\"><h2 class=\"kt-accordion-header-wrap\"><button class=\"kt-blocks-accordion-header kt-acccordion-button-label-show\" type=\"button\"><span class=\"kt-blocks-accordion-title-wrap\"><span class=\"kt-blocks-accordion-title\"><strong><strong><strong><strong>Does handheld XRF replace laboratory phosphate analysis?<\/strong><\/strong><\/strong><\/strong><\/span><\/span><span class=\"kt-blocks-accordion-icon-trigger\"><\/span><\/button><\/h2><div class=\"kt-accordion-panel kt-accordion-panel-hidden\"><div class=\"kt-accordion-panel-inner\">\n<ul class=\"wp-block-list\">\n<li>Not entirely. Handheld XRF provides rapid field information for screening and operational decisions, while laboratory-grade analysis remains important when certified or definitive results are required.<\/li>\n<\/ul>\n<\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Frequently Asked Questions<\/p>\n","protected":false},"author":38,"featured_media":14290,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[4,225],"tags":[16,535,536,23],"division":[],"class_list":["post-14189","post","type-post","status-publish","format-standard","has-post-thumbnail","category-exploration","category-general","tag-mining-2","tag-phosphate-mining","tag-phosphate-ore","tag-xrf","entry"],"_selected_authors":[787],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition - Advancing Mining<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition\" \/>\n<meta property=\"og:description\" content=\"Frequently Asked Questions\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-03T08:00:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine-1024x683.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"683\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marlene Gasdia-Cochrane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marlene Gasdia-Cochrane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/\"},\"author\":{\"name\":\"Marlene Gasdia-Cochrane\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\"},\"headline\":\"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition\",\"datePublished\":\"2026-11-03T08:00:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/\"},\"wordCount\":1135,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2026\\\/10\\\/iStock-177760247_phosphatemine.jpg\",\"keywords\":[\"mining\",\"phosphate mining\",\"phosphate ore\",\"xrf\"],\"articleSection\":[\"Exploration\",\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/\",\"name\":\"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition - Advancing Mining\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2026\\\/10\\\/iStock-177760247_phosphatemine.jpg\",\"datePublished\":\"2026-11-03T08:00:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2026\\\/10\\\/iStock-177760247_phosphatemine.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2026\\\/10\\\/iStock-177760247_phosphatemine.jpg\",\"width\":2121,\"height\":1414,\"caption\":\"An aerial view of an open pit phosphate mine\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\",\"name\":\"Marlene Gasdia-Cochrane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"caption\":\"Marlene Gasdia-Cochrane\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mgasdiacochrane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition - Advancing Mining","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","og_locale":"en_US","og_type":"article","og_title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","og_description":"Frequently Asked Questions","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2026-11-03T08:00:00+00:00","og_image":[{"width":1024,"height":683,"url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine-1024x683.jpg","type":"image\/jpeg"}],"author":"Marlene Gasdia-Cochrane","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Marlene Gasdia-Cochrane","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/"},"author":{"name":"Marlene Gasdia-Cochrane","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8"},"headline":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","datePublished":"2026-11-03T08:00:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/"},"wordCount":1135,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg","keywords":["mining","phosphate mining","phosphate ore","xrf"],"articleSection":["Exploration","General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","name":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition - Advancing Mining","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg","datePublished":"2026-11-03T08:00:00+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8"},"breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg","width":2121,"height":1414,"caption":"An aerial view of an open pit phosphate mine"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8","name":"Marlene Gasdia-Cochrane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","caption":"Marlene Gasdia-Cochrane"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"}]}},"taxonomy_info":{"category":[{"value":4,"label":"Exploration"},{"value":225,"label":"General"}],"post_tag":[{"value":16,"label":"mining"},{"value":535,"label":"phosphate mining"},{"value":536,"label":"phosphate ore"},{"value":23,"label":"xrf"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine-1024x683.jpg",760,507,true],"author_info":{"display_name":"Marlene Gasdia-Cochrane","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"},"comment_info":3,"category_info":[{"term_id":4,"name":"Exploration","slug":"exploration","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":151,"filter":"raw","meta":[],"cat_ID":4,"category_count":151,"category_description":"","cat_name":"Exploration","category_nicename":"exploration","category_parent":0},{"term_id":225,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":225,"taxonomy":"category","description":"","parent":0,"count":160,"filter":"raw","meta":[],"cat_ID":225,"category_count":160,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":[{"term_id":16,"name":"mining","slug":"mining-2","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":112,"filter":"raw","meta":[]},{"term_id":535,"name":"phosphate mining","slug":"phosphate-mining","term_group":0,"term_taxonomy_id":535,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":536,"name":"phosphate ore","slug":"phosphate-ore","term_group":0,"term_taxonomy_id":536,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]},{"term_id":23,"name":"xrf","slug":"xrf","term_group":0,"term_taxonomy_id":23,"taxonomy":"post_tag","description":"","parent":0,"count":47,"filter":"raw","meta":[]}],"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/14189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/38"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=14189"}],"version-history":[{"count":3,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/14189\/revisions"}],"predecessor-version":[{"id":14295,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/14189\/revisions\/14295"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/14290"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=14189"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=14189"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=14189"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=14189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}