{"id":3601,"date":"2015-01-13T08:27:38","date_gmt":"2015-01-13T13:27:38","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=3601"},"modified":"2019-08-05T20:02:56","modified_gmt":"2019-08-05T20:02:56","slug":"slurry-analysis-is-a-critical-part-of-oil-well-operations-2","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/","title":{"rendered":"Slurry Analysis Is a Critical Part of Oil Well Operations"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright\" style=\"float: right;border: 0;margin: 10px\" title=\"Ideal Cement Slurry\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2015\/01\/bestchoiceslurry.jpg\" alt=\"Ideal Cement Slurry\" width=\"527\" height=\"233\" \/>Oil well construction is a complex, multi-step process. Once the well is drilled, steel pipes, called casing, are run down the length of the hole and cemented into place.<\/p>\n<p>Cementing the casing is a critical part of well construction; cement seals the space between the well casing and the drill hole to hold the casing in place, stabilizes the well, and prevents oil and gas from leaking into the groundwater. View the infographic, <a href=\"http:\/\/www.api.org\/~\/media\/Files\/News\/Infographics\/Cementing_A_Seal_For_Safety.pdf\">Cementing: A Seal for Safety <\/a>from the American Petroleum Institute (API) for a snapshot of this process.<\/p>\n<p>Different<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?icid=CAD_blog_mining_2015\"> cements<\/a> are used for wells than for road or building construction because oil-well cement must be able to withstand a greater range of pressures and temperatures. There are eight different API classes of cement used in oil well construction designed to meet varying requirements for depth and temperature. To make well cement, a dry API grade consisting of primarily Portland cement is mixed with water to create wet cement, called slurry, which is pumped into the well. Slurry composition is critical to the cementing operation.<\/p>\n<p>Cement slurry design is a careful process of mixing multiple additives to modify the <a href=\"http:\/\/www.thermoscientific.com\/en\/search-results.html?keyword=cement&amp;matchDim=Y\" target=\"_blank\" rel=\"noopener noreferrer\">cement <\/a>properties and to mitigate or enhance the effects of other additives. Slurry performance properties include thickening time, compressive strength, density, viscosity, rheology, free fluid, and stability and are measured by observing the physical qualities of the slurry after the additives are incorporated. The <a href=\"http:\/\/petrowiki.org\/Cement_slurry_design\">Society of Petroleum Engineers PetroWiki site<\/a> offers the following guidelines for slurry design.<\/p>\n<p style=\"padding-left: 30px\">In formulating a cement slurry, the designer must consider not only the temperature but also the other downhole conditions, such as permeability and water-sensitive formations. A slurry should be designed for its specific application, with good properties to allow placement in a normal period. The ideal cement slurry should:<\/p>\n<ul style=\"padding-left: 30px\">\n<li style=\"list-style-type: none\">\n<ul>\n<li>Have no measurable free water<\/li>\n<li>Provide adequate fluid-loss control<\/li>\n<li>Contain adequate retarder to help ensure proper placement<\/li>\n<li>Maintain a stable density to ensure hydrostatic control<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p style=\"padding-left: 30px\">Slurry design is affected by the following criteria:<\/p>\n<ul style=\"padding-left: 30px\">\n<li style=\"list-style-type: none\">\n<ul>\n<li>Well depth<\/li>\n<li>Quality of mix water<\/li>\n<li>Bottomhole circulating temperature (BHCT)<\/li>\n<li>Fluid-loss control<\/li>\n<li>Bottomhole static temperature\u00a0(BHST)<\/li>\n<li>Flow regime<\/li>\n<li>Drilling fluid\u2019s hydrostatic pressure<\/li>\n<li>Settling and free water<\/li>\n<li>Type of drilling fluid<\/li>\n<li>Quality of cement<\/li>\n<li>Slurry density<\/li>\n<li>Dry or liquid additives<\/li>\n<li>Lost circulation<\/li>\n<li>Strength development<\/li>\n<li>Gas-migration potential<\/li>\n<li>Quality of the cement testing<\/li>\n<li>Pumping time<\/li>\n<li>Laboratory and equipment<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p>Cement slurry must be monitored constantly for variations in slurry density and proppant concentration to allow for immediate corrective action. \u00a0<a href=\"http:\/\/www.thermoscientific.com\/en\/product\/sgd-o-density-gauge-fracturing-cementing.html ?icid=CAD_blog_mining_2015\">Density gauges<\/a> have been designed to provide, accurate, real-time measurement of fluid density including PPG, PPA and SGU. These non-contacting density gauges are engineered to endure high shock and vibration as well as withstand the extreme moisture and high humidity of oilfield environments. Learn about other current and emerging technologies for <a href=\"http:\/\/www.thermoscientific.com\/en\/products\/cross-belt-analyzers.html ?icid=CAD_blog_mining_2015\">cement analysis<\/a>.<\/p>\n<h2>Update: Visit the<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?cid=cad_cad_vm_cement_sig_blog\">\u00a0Cement Production center<\/a>\u00a0on our website, with free resources to help you optimize your cement making process.<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?cid=cad_cad_vm_cement_sig_blog\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-11424\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125.jpg\" alt=\"\" width=\"600\" height=\"125\" srcset=\"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125.jpg 600w, https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125-300x63.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>Oil well construction is a complex, multi-step process. Once the well is drilled, steel pipes, called casing, are run down the length of the hole and cemented into place. Cementing the casing is a critical part of well construction; cement seals the space between the well casing and the drill hole to hold the casing<\/p>\n","protected":false},"author":145,"featured_media":3613,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[8,4],"tags":[],"division":[],"class_list":["post-3601","post","type-post","status-publish","format-standard","has-post-thumbnail","category-cement","category-exploration","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Slurry Analysis Is a Critical Part of Oil Well Operations<\/title>\n<meta name=\"description\" content=\"Learn about current and emerging technologies for cement analysis, including density gauges,\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Slurry Analysis Is a Critical Part of Oil Well Operations\" \/>\n<meta property=\"og:description\" content=\"Learn about current and emerging technologies for cement analysis, including density gauges,\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-01-13T13:27:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2019-08-05T20:02:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"527\" \/>\n\t<meta property=\"og:image:height\" content=\"233\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Tony Hart\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tony Hart\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/\"},\"author\":{\"name\":\"Tony Hart\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/e369d146e031bcec86aa9f883db5a5cc\"},\"headline\":\"Slurry Analysis Is a Critical Part of Oil Well Operations\",\"datePublished\":\"2015-01-13T13:27:38+00:00\",\"dateModified\":\"2019-08-05T20:02:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/\"},\"wordCount\":488,\"commentCount\":2,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/01\\\/bestchoiceslurry.jpg\",\"articleSection\":[\"Cement\",\"Exploration\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/\",\"name\":\"Slurry Analysis Is a Critical Part of Oil Well Operations\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/01\\\/bestchoiceslurry.jpg\",\"datePublished\":\"2015-01-13T13:27:38+00:00\",\"dateModified\":\"2019-08-05T20:02:56+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/e369d146e031bcec86aa9f883db5a5cc\"},\"description\":\"Learn about current and emerging technologies for cement analysis, including density gauges,\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/01\\\/bestchoiceslurry.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2015\\\/01\\\/bestchoiceslurry.jpg\",\"width\":527,\"height\":233,\"caption\":\"Ideal Cement Slurry\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Slurry Analysis Is a Critical Part of Oil Well Operations\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/e369d146e031bcec86aa9f883db5a5cc\",\"name\":\"Tony Hart\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e830ceadcbba5c50cbcaecbc84ac3332a393125bd95c6c92e932062840979359?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e830ceadcbba5c50cbcaecbc84ac3332a393125bd95c6c92e932062840979359?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/e830ceadcbba5c50cbcaecbc84ac3332a393125bd95c6c92e932062840979359?s=96&d=mm&r=g\",\"caption\":\"Tony Hart\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/tony-hartthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Slurry Analysis Is a Critical Part of Oil Well Operations","description":"Learn about current and emerging technologies for cement analysis, including density gauges,","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/","og_locale":"en_US","og_type":"article","og_title":"Slurry Analysis Is a Critical Part of Oil Well Operations","og_description":"Learn about current and emerging technologies for cement analysis, including density gauges,","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-01-13T13:27:38+00:00","article_modified_time":"2019-08-05T20:02:56+00:00","og_image":[{"width":527,"height":233,"url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg","type":"image\/jpeg"}],"author":"Tony Hart","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Tony Hart","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/"},"author":{"name":"Tony Hart","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/e369d146e031bcec86aa9f883db5a5cc"},"headline":"Slurry Analysis Is a Critical Part of Oil Well Operations","datePublished":"2015-01-13T13:27:38+00:00","dateModified":"2019-08-05T20:02:56+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/"},"wordCount":488,"commentCount":2,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg","articleSection":["Cement","Exploration"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/","name":"Slurry Analysis Is a Critical Part of Oil Well Operations","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg","datePublished":"2015-01-13T13:27:38+00:00","dateModified":"2019-08-05T20:02:56+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/e369d146e031bcec86aa9f883db5a5cc"},"description":"Learn about current and emerging technologies for cement analysis, including density gauges,","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg","width":527,"height":233,"caption":"Ideal Cement Slurry"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/slurry-analysis-is-a-critical-part-of-oil-well-operations-2\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Slurry Analysis Is a Critical Part of Oil Well Operations"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/e369d146e031bcec86aa9f883db5a5cc","name":"Tony Hart","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/e830ceadcbba5c50cbcaecbc84ac3332a393125bd95c6c92e932062840979359?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/e830ceadcbba5c50cbcaecbc84ac3332a393125bd95c6c92e932062840979359?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e830ceadcbba5c50cbcaecbc84ac3332a393125bd95c6c92e932062840979359?s=96&d=mm&r=g","caption":"Tony Hart"},"url":"https:\/\/admin.acceleratingscience.com\/author\/tony-hartthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":8,"label":"Cement"},{"value":4,"label":"Exploration"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg",527,233,false],"author_info":{"display_name":"Tony Hart","author_link":"https:\/\/admin.acceleratingscience.com\/author\/tony-hartthermofisher-com\/"},"comment_info":2,"category_info":[{"term_id":8,"name":"Cement","slug":"cement","term_group":0,"term_taxonomy_id":8,"taxonomy":"category","description":"","parent":0,"count":67,"filter":"raw","meta":[],"cat_ID":8,"category_count":67,"category_description":"","cat_name":"Cement","category_nicename":"cement","category_parent":0},{"term_id":4,"name":"Exploration","slug":"exploration","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":151,"filter":"raw","meta":[],"cat_ID":4,"category_count":151,"category_description":"","cat_name":"Exploration","category_nicename":"exploration","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":3601,"position":0},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14155,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-process-mass-spectrometry-based-on-line-gas-analysis-supports-compressed-biogas-quality-and-process-monitoring\/","url_meta":{"origin":3601,"position":1},"title":"How Process Mass Spectrometry-based On-line Gas Analysis Supports Compressed Biogas Quality and Process Monitoring","author":"Marlene Gasdia-Cochrane","date":"October 6, 2026","format":false,"excerpt":"Article Summary Compressed biogas (CBG) production requires continuous monitoring of gas composition from raw biogas through upgrading to final biomethane quality. Online gas analysis using process mass spectrometry provides real-time, multicomponent measurements that can help operators monitor methane, carbon dioxide, moisture, sulfur compounds and methane slip while improving visibility into\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Biogas production, biogas plant, bio power","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14164,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-analytical-technologies-support-an-expanding-u-s-power-generation-industry\/","url_meta":{"origin":3601,"position":2},"title":"How Analytical Technologies Support an Expanding U.S. Power Generation Industry","author":"Marlene Gasdia-Cochrane","date":"October 20, 2026","format":false,"excerpt":"Introduction Breaking Energy News (BEN), IIR Intelligence, recently reported that U.S. power-generation projects totaling $16.8 billion were slated to begin construction in September 2026, led by solar, natural gas, and battery storage. The 60 projects represent more than 18 GW of capacity, including roughly 11.4 GW of new generation, reflecting\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Equipment, cables and piping as found inside of a modern industrial power plant\"n","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-917675818_powerplant.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":3601,"position":3},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":3601,"position":4},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14089,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-real-time-monitoring-is-transforming-refined-fuel-quality-control\/","url_meta":{"origin":3601,"position":5},"title":"Why Real-Time Monitoring Is Transforming Refined Fuel Quality Control","author":"Marlene Gasdia-Cochrane","date":"July 21, 2026","format":false,"excerpt":"Article Summary Refinery operations depend on precise control of fuel properties. Whether producing gasoline, diesel, jet fuel, or base oils, even small variations can impact product performance, regulatory compliance, and profitability. Traditionally, fuel quality has been verified through a combination of laboratory testing and online analyzers. While these methods are\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Aerial view of oil refinery and storage tanks at dusk and night, showcasing energy industry infrastructure, petroleum processing, and industrial landscape.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/01\/bestchoiceslurry.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/3601","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/145"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=3601"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/3601\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/3613"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=3601"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=3601"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=3601"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=3601"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}