
{"id":3934,"date":"2024-02-21T08:00:12","date_gmt":"2024-02-21T08:00:12","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=3934"},"modified":"2026-02-09T14:18:59","modified_gmt":"2026-02-09T14:18:59","slug":"technology-focus-x-ray-fluorescence-xrf-in-mining","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/","title":{"rendered":"Technology Focus: X-ray Fluorescence (XRF) in Mining"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"border: 0;float: right;margin: 10px\" title=\"Handheld XRF diagram\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2015\/04\/gun-diagram.jpg\" alt=\"Handheld XRF diagram\" width=\"350\" height=\"349\" \/>This blog often discusses the advantages of utilizing portable<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/spectroscopy-elemental-isotope-analysis-learning-center\/elemental-analysis-information\/xrf-technology.html?icid=CAD_blog_mining_2024Feb\"> X-ray Fluorescence (XRF) technology<\/a> for providing immediate, actionable data for <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals.html?icid=CAD_blog_mining_2024Feb\">mining and exploration<\/a>. But what is XRF, and how does it work?<\/p>\n<p>XRF is a non-destructive analytical technique used to determine the elemental composition of materials.<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id.html?icid=CAD_blog_mining_2024Feb\"> XRF analyzers<\/a> determine the chemistry of a sample by measuring the fluorescent (or secondary) X-ray emitted from a sample when it is excited by a primary X-ray source. Because this fluorescence is unique to the elemental composition of the sample, XRF is an excellent technology for qualitative and quantitative analysis of the material composition. To the right is an illustration of how a handheld XRF instrument works.<\/p>\n<h2><span style=\"font-size: 18pt\">The X-ray Fluorescence Process<\/span><\/h2>\n<ol>\n<li>A solid or a liquid sample is irradiated with high energy X-rays from a controlled X-ray tube.<\/li>\n<li>When an atom in the sample is struck with an X-ray of sufficient energy (greater than the atom\u2019s K or L shell binding energy), an electron from one of the atom\u2019s inner orbital shells is dislodged.<\/li>\n<li>The atom regains stability, filling the vacancy left in the inner orbital shell with an electron from one of the atom\u2019s higher energy orbital shells.<\/li>\n<li>The electron drops to the lower energy state by releasing a fluorescent X-ray. The energy of this X-ray is equal to the specific difference in energy between two quantum states of the electron. The measurement of this energy is the basis of XRF analysis.<\/li>\n<\/ol>\n<h2><span style=\"font-size: 18pt\">Interpretation of XRF Spectra<\/span><\/h2>\n<p>Each of the elements present in a sample produces a set of characteristic fluorescent X-rays that is unique for that specific element, which is why XRF spectroscopy is especially useful for elemental analysis. This elemental \u201cfingerprint\u201d is best illustrated by examining the X-ray energy spectrum and its \u201cscattering peaks.\u201d Most atoms have several electron orbitals (K shell, L shell, M shell, for example). When X-ray energy causes electrons to transfer in and out of these shell levels, XRF peaks with varying intensities are created and will be present in the spectrum. The peak energy identifies the element, and the peak height \/ intensity is generally indicative of its concentration.<\/p>\n<h2><span style=\"font-size: 18pt\">Considerations<\/span><\/h2>\n<p>Phenomena that can influence the results of XRF analysis include scattering, which occurs when incoming X-rays do not produce fluorescence, but rather \u201ccollide\u201d with the atoms of the sample which results in a change in the direction of motion of a particle. Spectral effects occur when elements have lines that overlap other elements. Matrix effects include enhancement effects, which occur when some fluorescent X-rays have more energy than the binding energy of other elements present in the sample, and absorption effects, which occur when a fluorescent X-ray does not reach the detector as it is scattered or absorbed by other elements present in the sample.<\/p>\n<h2><span style=\"font-size: 18pt\">XRF Applications in Mining<\/span><\/h2>\n<p><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals\/solutions.html?icid=CAD_blog_mining_2024Feb#exploration\">Handheld XRF analyzers<\/a> are a reliable method to analyze ore samples in open pits and underground mines \u2013 achieving the accuracy required to provide defensible information for process oversight, quality assurance, and various other operational decisions (such as grade control). Portable XRF technology can help ascertain the viability of lower grade resources and find localized high-grade enrichments,\u00a0delineate ore from waste boundaries to reduce the randomness of digging, and obtain defensible data and minimize the need to send samples to external testing labs.<\/p>\n<p>Sample analysis with <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals\/solutions.html?icid=CAD_blog_mining_2024Feb#exploration\">handheld XRF analyzers<\/a> offers a substantial advantage in mining operations by providing immediate feedback for quick decision making on site:<\/p>\n<ul>\n<li>Whether to stop or continue drilling<\/li>\n<li>When to make equipment relocation decisions<\/li>\n<li>Where to focus on the grid<\/li>\n<li>When to select a sample for laboratory analysis.<\/li>\n<\/ul>\n<p>Real-time analysis with handheld XRF analyzers is also a good way to prequalify samples for off-site lab analysis to ensure only the best samples are evaluated. Portable handheld analyzers can be operated virtually anywhere on site and easily accommodate a wide variation of samples, with little or no sample preparation. XRF analyzers also quickly deliver exploration data for quantitative geochemical analysis of metal concentrations for geochemical mapping. If you want a quick read, but more information, about Handheld XRF and how it works, download our free ebook: <em><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/xrf-ebook-download-request.html?icid=CAD_blog_mining_2024Feb\" target=\"_blank\" rel=\"noopener\">Portable XRF Technology for the Non-Scientist<\/a>.<\/em><\/p>\n<h2>Additional Resources<\/h2>\n<ul>\n<li>ebook: <em><a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/global\/forms\/industrial\/xrf-ebook-download-request.html?icid=CAD_blog_mining_2024Feb\" target=\"_blank\" rel=\"noopener\">Portable XRF Technology for the Non-Scientist<\/a><\/em><\/li>\n<li>Online resources for <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/mining-minerals.html?icid=CAD_blog_mining_2024Feb\">Mining &amp; Minerals<\/a><\/li>\n<\/ul>\n<p><em>Editor&#8217;s Note:\u00a0 This article was originally authored by Esa Nummi and published in April 2015, but has been updated and refreshed.<\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>This blog often discusses the advantages of utilizing portable X-ray Fluorescence (XRF) technology for providing immediate, actionable data for mining and exploration. But what is XRF, and how does it work? XRF is a non-destructive analytical technique used to determine the elemental composition of materials. XRF analyzers determine the chemistry of a sample by measuring<\/p>\n","protected":false},"author":38,"featured_media":13029,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[6,4,225,11],"tags":[335,336,337,196,338,339],"division":[],"class_list":["post-3934","post","type-post","status-publish","format-standard","has-post-thumbnail","category-elemental-geochemical-analysis","category-exploration","category-general","category-portable-xrf","tag-mineral-identification","tag-mining-analyzer","tag-mining-elemental-analysis","tag-mining-xrf","tag-portable-xrf-analysis","tag-xrf-technology","entry"],"_selected_authors":[754],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Technology Focus: X-ray Fluorescence (XRF) in Mining<\/title>\n<meta name=\"description\" content=\"Learn about Portable XRF technology, and how it is used for qualitative and quantitative analysis of mining materials during exploration.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Technology Focus: X-ray Fluorescence (XRF) in Mining\" \/>\n<meta property=\"og:description\" content=\"Learn about Portable XRF technology, and how it is used for qualitative and quantitative analysis of mining materials during exploration.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-21T08:00:12+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-09T14:18:59+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2119\" \/>\n\t<meta property=\"og:image:height\" content=\"1415\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Marlene Gasdia-Cochrane\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marlene Gasdia-Cochrane\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/\"},\"author\":{\"name\":\"Marlene Gasdia-Cochrane\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\"},\"headline\":\"Technology Focus: X-ray Fluorescence (XRF) in Mining\",\"datePublished\":\"2024-02-21T08:00:12+00:00\",\"dateModified\":\"2026-02-09T14:18:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/\"},\"wordCount\":730,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2024\\\/02\\\/iStock-533571686.jpg\",\"keywords\":[\"mineral identification\",\"mining analyzer\",\"mining elemental analysis\",\"mining xrf\",\"portable xrf analysis\",\"xrf technology\"],\"articleSection\":[\"Elemental\\\/Geochemical Analysis\",\"Exploration\",\"General\",\"Portable XRF\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/\",\"name\":\"Technology Focus: X-ray Fluorescence (XRF) in Mining\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2024\\\/02\\\/iStock-533571686.jpg\",\"datePublished\":\"2024-02-21T08:00:12+00:00\",\"dateModified\":\"2026-02-09T14:18:59+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\"},\"description\":\"Learn about Portable XRF technology, and how it is used for qualitative and quantitative analysis of mining materials during exploration.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2024\\\/02\\\/iStock-533571686.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2024\\\/02\\\/iStock-533571686.jpg\",\"width\":2119,\"height\":1415,\"caption\":\"copper ore placed on periodic table\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/technology-focus-x-ray-fluorescence-xrf-in-mining\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Technology Focus: X-ray Fluorescence (XRF) in Mining\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/fb6befa44b6a83c9a215be75d33bb8e8\",\"name\":\"Marlene Gasdia-Cochrane\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g\",\"caption\":\"Marlene Gasdia-Cochrane\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/mgasdiacochrane\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Technology Focus: X-ray Fluorescence (XRF) in Mining","description":"Learn about Portable XRF technology, and how it is used for qualitative and quantitative analysis of mining materials during exploration.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/","og_locale":"en_US","og_type":"article","og_title":"Technology Focus: X-ray Fluorescence (XRF) in Mining","og_description":"Learn about Portable XRF technology, and how it is used for qualitative and quantitative analysis of mining materials during exploration.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2024-02-21T08:00:12+00:00","article_modified_time":"2026-02-09T14:18:59+00:00","og_image":[{"width":2119,"height":1415,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg","type":"image\/jpeg"}],"author":"Marlene Gasdia-Cochrane","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Marlene Gasdia-Cochrane","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/"},"author":{"name":"Marlene Gasdia-Cochrane","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8"},"headline":"Technology Focus: X-ray Fluorescence (XRF) in Mining","datePublished":"2024-02-21T08:00:12+00:00","dateModified":"2026-02-09T14:18:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/"},"wordCount":730,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg","keywords":["mineral identification","mining analyzer","mining elemental analysis","mining xrf","portable xrf analysis","xrf technology"],"articleSection":["Elemental\/Geochemical Analysis","Exploration","General","Portable XRF"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/","name":"Technology Focus: X-ray Fluorescence (XRF) in Mining","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg","datePublished":"2024-02-21T08:00:12+00:00","dateModified":"2026-02-09T14:18:59+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8"},"description":"Learn about Portable XRF technology, and how it is used for qualitative and quantitative analysis of mining materials during exploration.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg","width":2119,"height":1415,"caption":"copper ore placed on periodic table"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Technology Focus: X-ray Fluorescence (XRF) in Mining"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/fb6befa44b6a83c9a215be75d33bb8e8","name":"Marlene Gasdia-Cochrane","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d4ecccff16bb946462f4389b39255e116430923ec42d08f298b5633eba2d07dd?s=96&d=mm&r=g","caption":"Marlene Gasdia-Cochrane"},"url":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"}]}},"taxonomy_info":{"category":[{"value":6,"label":"Elemental\/Geochemical Analysis"},{"value":4,"label":"Exploration"},{"value":225,"label":"General"},{"value":11,"label":"Portable XRF"}],"post_tag":[{"value":335,"label":"mineral identification"},{"value":336,"label":"mining analyzer"},{"value":337,"label":"mining elemental analysis"},{"value":196,"label":"mining xrf"},{"value":338,"label":"portable xrf analysis"},{"value":339,"label":"xrf technology"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686-1024x684.jpg",760,508,true],"author_info":{"display_name":"Marlene Gasdia-Cochrane","author_link":"https:\/\/admin.acceleratingscience.com\/author\/mgasdiacochrane\/"},"comment_info":1,"category_info":[{"term_id":6,"name":"Elemental\/Geochemical Analysis","slug":"elemental-geochemical-analysis","term_group":0,"term_taxonomy_id":6,"taxonomy":"category","description":"","parent":0,"count":144,"filter":"raw","meta":[],"cat_ID":6,"category_count":144,"category_description":"","cat_name":"Elemental\/Geochemical Analysis","category_nicename":"elemental-geochemical-analysis","category_parent":0},{"term_id":4,"name":"Exploration","slug":"exploration","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":151,"filter":"raw","meta":[],"cat_ID":4,"category_count":151,"category_description":"","cat_name":"Exploration","category_nicename":"exploration","category_parent":0},{"term_id":225,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":225,"taxonomy":"category","description":"","parent":0,"count":160,"filter":"raw","meta":[],"cat_ID":225,"category_count":160,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":11,"name":"Portable XRF","slug":"portable-xrf","term_group":0,"term_taxonomy_id":11,"taxonomy":"category","description":"","parent":0,"count":76,"filter":"raw","meta":[],"cat_ID":11,"category_count":76,"category_description":"","cat_name":"Portable XRF","category_nicename":"portable-xrf","category_parent":0}],"tag_info":[{"term_id":335,"name":"mineral identification","slug":"mineral-identification","term_group":0,"term_taxonomy_id":335,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":336,"name":"mining analyzer","slug":"mining-analyzer","term_group":0,"term_taxonomy_id":336,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":337,"name":"mining elemental analysis","slug":"mining-elemental-analysis","term_group":0,"term_taxonomy_id":337,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":196,"name":"mining xrf","slug":"mining-xrf","term_group":0,"term_taxonomy_id":196,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw","meta":[]},{"term_id":338,"name":"portable xrf analysis","slug":"portable-xrf-analysis","term_group":0,"term_taxonomy_id":338,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]},{"term_id":339,"name":"xrf technology","slug":"xrf-technology","term_group":0,"term_taxonomy_id":339,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":3934,"position":0},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14189,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url_meta":{"origin":3934,"position":1},"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","author":"Marlene Gasdia-Cochrane","date":"November 3, 2026","format":false,"excerpt":"Article Summary Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, mining operations increasingly need to process lower-grade ores with more variable chemical compositions. Handheld X-ray fluorescence (XRF) provides a fast,\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"An aerial view of an open pit phosphate mine","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":3934,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":3934,"position":3},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":3934,"position":4},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":3934,"position":5},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2024\/02\/iStock-533571686.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/3934","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/38"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=3934"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/3934\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/13029"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=3934"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=3934"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=3934"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=3934"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}