{"id":4886,"date":"2015-06-23T08:00:09","date_gmt":"2015-06-23T12:00:09","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=4886"},"modified":"2026-01-13T16:41:54","modified_gmt":"2026-01-13T16:41:54","slug":"going-to-the-source-x-ray-tubes","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/","title":{"rendered":"Going to the Source: X-ray Tubes"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right;border: 0;margin: 10px\" title=\"x-ray source\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2015\/06\/xraysource3.jpg\" alt=\"x-ray source\" width=\"500\" height=\"327\" \/>X-ray fluorescence (XRF) technology is a powerful technique for elemental analysis. The XRF process starts with irradiating a solid or liquid sample with high energy x-rays from a controlled X-ray source. In handheld and portable Energy-dispersive X-ray Fluorescence (EDXRF) instruments, the X-ray source is typically an X-ray tube, which has several advantages over radioisotopes including less stringent licensing issues and the fact that X-ray emissions from tubes can be easily modified for specific analytical applications. In this blog, we\u2019ll explain how an X-ray tube works. The major X-ray tube components are the cathode, anode, the tube envelope, the tube housing, and the window.<\/p>\n<p><a href=\"http:\/\/radiopaedia.org\/articles\/cathode-1\"><strong>Cathode<\/strong><\/a><\/p>\n<p>The cathode serves to expel the electrons from the circuit and focus them in a beam on the focal spot of the anode. It is a controlled source of electrons for the generation of X-ray beams. The electrons are produced by heating the filament, i.e., a coil of wire made from tungsten, placed within a highly polished nickel focusing cup providing electrostatic focusing of the beam on the anode. Heat is used to expel the electrons from the cathode.<\/p>\n<p><a href=\"http:\/\/radiopaedia.org\/articles\/anode-1\"><strong>Anode<\/strong><\/a><\/p>\n<p>The anode\u00a0represents the component in which the x-rays are produced. It is a piece of metal, shaped in the form of a beveled disk, connected to the positive side of electrical circuit. The anode converts the energy of the electrons into X-rays and dissipates the heat, considered the byproduct.<\/p>\n<p><strong>Envelope<\/strong><\/p>\n<p>An airtight enclosure that houses the cathode and anode. It is often made from metal and ceramic because these materials are able to withstand the tremendous amount of heat generated during X-ray production, but they can also be made of glass.<\/p>\n<p><strong>Housing<\/strong><\/p>\n<p>Provides protection and absorbs excess radiation.<\/p>\n<p><strong>Window<\/strong><\/p>\n<p>The X-ray tube window typically is made from beryllium because it allows X-rays to pass through but has sufficient strength to hold the vacuum required for the X-ray tube to operate. When an electrical current is passed through the cathode, the electrons generated by the cathode are accelerated by high voltage towards a metal target, or anode. X-rays known as Bremsstrahlung (\u201cbraking radiation\u201d) are produced when the electrons are suddenly decelerated upon collision with the anode. When an atom in the sample is struck with an X-ray of sufficient energy (greater than the atom\u2019s K or L shell binding energy), an electron from one of the atom\u2019s inner orbital shells is dislodged. The atom regains stability, filling the vacancy left in the inner orbital shell with an electron from one of the atom\u2019s higher energy orbital shells. The electron drops to the lower energy state by releasing a fluorescent X-ray. The energy of this X-ray is equal to the specific difference in energy between two quantum states of the electron. These X-rays all have sufficient energy to pass through the X-ray tube window and reach the sample. The measurement of this energy is the basis of <a href=\"http:\/\/admin.acceleratingscience.com\/mining\/technology-focus-x-ray-fluorescence-xrf-in-mining\/\">XRF analysis<\/a>.<\/p>\n<p><strong>Requirements for Handheld X-ray Tube Based XRF Analyzers<\/strong> In the United States devices with X-ray tubes as the signal source are regulated by state, often the same state agency that controls radioactive material when the state is an\u00a0<a href=\"http:\/\/nrc-stp.ornl.gov\/rulemaking.html\">agreement state<\/a>. In almost all states, a registration, but not a license, is required.\u00a0Usually, the registration form provides the state with information about the device, its purpose, and your company.\u00a0Many states charge an annual registration fee. In a few states, there are more strict requirements such as an on-site device inspection and certification by a local radiation safety consultant as a prerequisite to obtaining the registration and authorization to use the device.<\/p>\n<p>Contact your\u00a0state regulator for further information, particularly prior to transporting or operating an XRF analyzer in another state.<\/p>\n<p>To learn more about XRF technology, handheld and portable XRF analyzers, and their many applications in the mining industry, download the free eBook, <a href=\"http:\/\/info3.thermoscientific.com\/LP=415?wt.mc_id=cad_xrf_eBook_banner_blog_1014_mining\" target=\"_blank\" rel=\"noopener\">XRF in the Field: Technology for the Non-Scientist<\/a>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>X-ray fluorescence (XRF) technology is a powerful technique for elemental analysis. The XRF process starts with irradiating a solid or liquid sample with high energy x-rays from a controlled X-ray source. In handheld and portable Energy-dispersive X-ray Fluorescence (EDXRF) instruments, the X-ray source is typically an X-ray tube, which has several advantages over radioisotopes including<\/p>\n","protected":false},"author":55,"featured_media":9104,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[225],"tags":[],"division":[],"class_list":["post-4886","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","entry"],"_selected_authors":[1047],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Going to the Source: X-ray Tubes<\/title>\n<meta name=\"description\" content=\"Requirements for Handheld X-ray Tube Based XRF Analyzers. Learn about x-ray tube and source technology.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Going to the Source: X-ray Tubes\" \/>\n<meta property=\"og:description\" content=\"Requirements for Handheld X-ray Tube Based XRF Analyzers. Learn about x-ray tube and source technology.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-06-23T12:00:09+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-13T16:41:54+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"813\" \/>\n\t<meta property=\"og:image:height\" content=\"531\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Esa Nummi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Esa Nummi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/\"},\"author\":{\"name\":\"Esa Nummi\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/8f024d1aa22410c9f92ebdac919e8925\"},\"headline\":\"Going to the Source: X-ray Tubes\",\"datePublished\":\"2015-06-23T12:00:09+00:00\",\"dateModified\":\"2026-01-13T16:41:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/\"},\"wordCount\":655,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/xraysource3.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/\",\"name\":\"Going to the Source: X-ray Tubes\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/xraysource3.jpg\",\"datePublished\":\"2015-06-23T12:00:09+00:00\",\"dateModified\":\"2026-01-13T16:41:54+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/8f024d1aa22410c9f92ebdac919e8925\"},\"description\":\"Requirements for Handheld X-ray Tube Based XRF Analyzers. Learn about x-ray tube and source technology.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/xraysource3.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/xraysource3.jpg\",\"width\":813,\"height\":531,\"caption\":\"x-ray source\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/going-to-the-source-x-ray-tubes\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Going to the Source: X-ray Tubes\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/8f024d1aa22410c9f92ebdac919e8925\",\"name\":\"Esa Nummi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/612d84861406b7e913bb50763a7ce6995f9f2bde4a6ae8fd8f182c64e09b834e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/612d84861406b7e913bb50763a7ce6995f9f2bde4a6ae8fd8f182c64e09b834e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/612d84861406b7e913bb50763a7ce6995f9f2bde4a6ae8fd8f182c64e09b834e?s=96&d=mm&r=g\",\"caption\":\"Esa Nummi\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/esa-nummithermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Going to the Source: X-ray Tubes","description":"Requirements for Handheld X-ray Tube Based XRF Analyzers. Learn about x-ray tube and source technology.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/","og_locale":"en_US","og_type":"article","og_title":"Going to the Source: X-ray Tubes","og_description":"Requirements for Handheld X-ray Tube Based XRF Analyzers. Learn about x-ray tube and source technology.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-06-23T12:00:09+00:00","article_modified_time":"2026-01-13T16:41:54+00:00","og_image":[{"width":813,"height":531,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg","type":"image\/jpeg"}],"author":"Esa Nummi","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Esa Nummi","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/"},"author":{"name":"Esa Nummi","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/8f024d1aa22410c9f92ebdac919e8925"},"headline":"Going to the Source: X-ray Tubes","datePublished":"2015-06-23T12:00:09+00:00","dateModified":"2026-01-13T16:41:54+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/"},"wordCount":655,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/","name":"Going to the Source: X-ray Tubes","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg","datePublished":"2015-06-23T12:00:09+00:00","dateModified":"2026-01-13T16:41:54+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/8f024d1aa22410c9f92ebdac919e8925"},"description":"Requirements for Handheld X-ray Tube Based XRF Analyzers. Learn about x-ray tube and source technology.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg","width":813,"height":531,"caption":"x-ray source"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/going-to-the-source-x-ray-tubes\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Going to the Source: X-ray Tubes"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/8f024d1aa22410c9f92ebdac919e8925","name":"Esa Nummi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/612d84861406b7e913bb50763a7ce6995f9f2bde4a6ae8fd8f182c64e09b834e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/612d84861406b7e913bb50763a7ce6995f9f2bde4a6ae8fd8f182c64e09b834e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/612d84861406b7e913bb50763a7ce6995f9f2bde4a6ae8fd8f182c64e09b834e?s=96&d=mm&r=g","caption":"Esa Nummi"},"url":"https:\/\/admin.acceleratingscience.com\/author\/esa-nummithermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":225,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg",760,496,false],"author_info":{"display_name":"Esa Nummi","author_link":"https:\/\/admin.acceleratingscience.com\/author\/esa-nummithermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":225,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":225,"taxonomy":"category","description":"","parent":0,"count":160,"filter":"raw","meta":[],"cat_ID":225,"category_count":160,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":4886,"position":0},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":4886,"position":1},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":4886,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14189,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url_meta":{"origin":4886,"position":3},"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","author":"Marlene Gasdia-Cochrane","date":"November 3, 2026","format":false,"excerpt":"Article Summary Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, mining operations increasingly need to process lower-grade ores with more variable chemical compositions. Handheld X-ray fluorescence (XRF) provides a fast,\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"An aerial view of an open pit phosphate mine","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":4886,"position":4},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":4886,"position":5},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/xraysource3.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/4886","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/55"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=4886"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/4886\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/9104"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=4886"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=4886"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=4886"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=4886"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}