
{"id":4949,"date":"2015-07-21T08:00:14","date_gmt":"2015-07-21T12:00:14","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=4949"},"modified":"2026-02-20T23:26:02","modified_gmt":"2026-02-20T23:26:02","slug":"correlating-yield-stress-with-pumpability-of-mining-tailings","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/","title":{"rendered":"Correlating Yield Stress with Pumpability of Mining Tailings"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2015\/07\/istock_000007415705_medium.jpg\" style=\"float: right;border: 0;margin: 10px\" alt=\"mine tailings pond\" title=\"mine tailings pond\" width=\"350\" height=\"232\" \/>In a previous article,&nbsp;<a href=\"http:\/\/admin.acceleratingscience.com\/mining\/determining-the-rheological-properties-of-mine-tailings\" target=\"_blank\"><em>Determining the Rheological Properties of Mine Tailings<\/em><\/a>,we discussed the fact that the composition of tailings depends on the composition of the ore and the extraction process used to obtain the ore.&nbsp;Tailings are the materials left over after the process of separating the valuable fraction from the uneconomic fraction (gangue) of an ore. Tailings are distinct from overburden, which is the waste rock or materials overlying an ore or mineral body that are displaced during mining without being processed.<\/p>\n<p>The extraction of minerals from ore can be done two ways: placer mining, which uses water and gravity to extract the valuable minerals, or hard rock mining, which uses pulverization of rock, then chemicals. In the latter, the extraction of minerals from ore requires that the ore be ground into fine particles, so tailings are typically small and range from the size of a grain of sand to a few micrometres. Mine tailings are usually produced from the mill in slurry form (a mixture of fine mineral particles and water). The composition of tailings is directly dependent on the composition of the ore and the process of mineral extraction used on the ore. Usually, the major quantity of a tailings product consists of rock, mainly ground to a fine size ranging from coarse sands down to powder consistency. Many tailings may also contain small quantities of different metals that are found in the host ore as well as added components used in the extraction process.*<\/p>\n<p>Usually tailings are stored in tailing ponds. Tailing ponds are areas where the waterborne refuse material is pumped into a pond to allow the sedimentation of solid particles from the water. Tailings ponds are instrumental in storing the waste coming from separating minerals from rocks, or the slurry produced from tar sands mining. Often, tailings are mixed with other materials like bentonite to slow down the release of impacted water to the environment. However, no matter which composition the tailing has, it needs to be pumped from the mine to the pond. In order to understand if a (modified) tailing can be pumped with the existing pumping equipment, not just the viscosity needs to be determined but also the yield stress. The yield stress describes the amount of energy needed to overcome elastic behaviour for a given fluid and enter sustainable flow.<\/p>\n<p>This yield stress value&nbsp;is strongly dependent on solid content of the slurry.&nbsp;Rheological measurements such as viscosity, elasticity, processability, temperature-related mechanical change, and the yield stress value of mining tailings can be extracted easily from a simple measurement using a <a href=\"http:\/\/www.thermoscientific.com\/en\/products\/rheometers.html\" target=\"_blank\">rheometer<\/a>. Those values can then be easily correlated with the pumpability of a specific tailing formulation with given solids mass fraction.<\/p>\n<p>Our next article will summarize the procedure and results of rheological tests conducted to evaluate the pumpability of specific tailings.<\/p>\n<p>&nbsp;<\/p>\n<p><em>* Note: &nbsp;References used:<\/em><\/p>\n<ul>\n<li><em>Wikipedia, Tailings, http:\/\/en. wikipedia\/wiki\/Tailings (as of July 13, 2014, 16:50 CET) <\/em><\/li>\n<li><em>US EPA. (1994). Technical Report: Design and Eva- luation of Tailinfs Dams.<\/em><\/li>\n<li><em>Martin T.E., Davies M.P. (2000). Trends in the stewardship of tailings dams. 1996, Essen <\/em><\/li>\n<li><em>Dzuy N.Q., Boger D.V. (1985). Direct yield stress measu- rement with the vane method. J Rheol 29:335-47.<\/em><\/li>\n<\/ul>\n<p><em>&nbsp; &nbsp; &nbsp; For specifics, see&nbsp;<a href=\"http:\/\/www.thermoscientific.com\/content\/dam\/tfs\/ATG\/CAD\/CAD%20Documents\/Application%20&amp;%20Technical%20Notes\/Material%20Characterization%20and%20Testing\/Rheometers\/Rotational%20Rheometers\/V277-e%20Correlating%20yield%20stress%20with%20pumpability%20of%20mining%20tailings%20.pdf\" target=\"_blank\">Correlating Yield Stress with Pumpability of Mining Tailings<\/a><\/em><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In a previous article,&nbsp;Determining the Rheological Properties of Mine Tailings,we discussed the fact that the composition of tailings depends on the composition of the ore and the extraction process used to obtain the ore.&nbsp;Tailings are the materials left over after the process of separating the valuable fraction from the uneconomic fraction (gangue) of an ore.<\/p>\n","protected":false},"author":61,"featured_media":9117,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[10],"tags":[],"division":[],"class_list":["post-4949","post","type-post","status-publish","format-standard","has-post-thumbnail","category-mineral-processing","entry"],"_selected_authors":[1410],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Correlating Yield Stress with Pumpability of Mining Tailings<\/title>\n<meta name=\"description\" content=\"To determine if tailings can be pumped with the existing pumping equipment, the viscosity and the yield stress need to be measured with rheometers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Correlating Yield Stress with Pumpability of Mining Tailings\" \/>\n<meta property=\"og:description\" content=\"To determine if tailings can be pumped with the existing pumping equipment, the viscosity and the yield stress need to be measured with rheometers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2015-07-21T12:00:14+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-20T23:26:02+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium-1024x680.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1024\" \/>\n\t<meta property=\"og:image:height\" content=\"680\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Jan Philip Plog\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Jan Philip Plog\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/\"},\"author\":{\"name\":\"Jan Philip Plog\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/10ce0a7e6af566e85e053ef96f578067\"},\"headline\":\"Correlating Yield Stress with Pumpability of Mining Tailings\",\"datePublished\":\"2015-07-21T12:00:14+00:00\",\"dateModified\":\"2026-02-20T23:26:02+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/\"},\"wordCount\":562,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000007415705_medium.jpg\",\"articleSection\":[\"Mineral Processing\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/\",\"name\":\"Correlating Yield Stress with Pumpability of Mining Tailings\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000007415705_medium.jpg\",\"datePublished\":\"2015-07-21T12:00:14+00:00\",\"dateModified\":\"2026-02-20T23:26:02+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/10ce0a7e6af566e85e053ef96f578067\"},\"description\":\"To determine if tailings can be pumped with the existing pumping equipment, the viscosity and the yield stress need to be measured with rheometers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000007415705_medium.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000007415705_medium.jpg\",\"width\":1701,\"height\":1129,\"caption\":\"mine tailings pond\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/correlating-yield-stress-with-pumpability-of-mining-tailings\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Correlating Yield Stress with Pumpability of Mining Tailings\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/10ce0a7e6af566e85e053ef96f578067\",\"name\":\"Jan Philip Plog\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b500e95b2561342a5c83a892f88048ef19445463d04d7dd029d438ce04ff3104?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b500e95b2561342a5c83a892f88048ef19445463d04d7dd029d438ce04ff3104?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b500e95b2561342a5c83a892f88048ef19445463d04d7dd029d438ce04ff3104?s=96&d=mm&r=g\",\"caption\":\"Jan Philip Plog\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/jan-plogthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Correlating Yield Stress with Pumpability of Mining Tailings","description":"To determine if tailings can be pumped with the existing pumping equipment, the viscosity and the yield stress need to be measured with rheometers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/","og_locale":"en_US","og_type":"article","og_title":"Correlating Yield Stress with Pumpability of Mining Tailings","og_description":"To determine if tailings can be pumped with the existing pumping equipment, the viscosity and the yield stress need to be measured with rheometers.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2015-07-21T12:00:14+00:00","article_modified_time":"2026-02-20T23:26:02+00:00","og_image":[{"width":1024,"height":680,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium-1024x680.jpg","type":"image\/jpeg"}],"author":"Jan Philip Plog","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Jan Philip Plog","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/"},"author":{"name":"Jan Philip Plog","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/10ce0a7e6af566e85e053ef96f578067"},"headline":"Correlating Yield Stress with Pumpability of Mining Tailings","datePublished":"2015-07-21T12:00:14+00:00","dateModified":"2026-02-20T23:26:02+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/"},"wordCount":562,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium.jpg","articleSection":["Mineral Processing"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/","name":"Correlating Yield Stress with Pumpability of Mining Tailings","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium.jpg","datePublished":"2015-07-21T12:00:14+00:00","dateModified":"2026-02-20T23:26:02+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/10ce0a7e6af566e85e053ef96f578067"},"description":"To determine if tailings can be pumped with the existing pumping equipment, the viscosity and the yield stress need to be measured with rheometers.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium.jpg","width":1701,"height":1129,"caption":"mine tailings pond"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/correlating-yield-stress-with-pumpability-of-mining-tailings\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Correlating Yield Stress with Pumpability of Mining Tailings"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/10ce0a7e6af566e85e053ef96f578067","name":"Jan Philip Plog","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b500e95b2561342a5c83a892f88048ef19445463d04d7dd029d438ce04ff3104?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b500e95b2561342a5c83a892f88048ef19445463d04d7dd029d438ce04ff3104?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b500e95b2561342a5c83a892f88048ef19445463d04d7dd029d438ce04ff3104?s=96&d=mm&r=g","caption":"Jan Philip Plog"},"url":"https:\/\/admin.acceleratingscience.com\/author\/jan-plogthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":10,"label":"Mineral Processing"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium-1024x680.jpg",760,505,true],"author_info":{"display_name":"Jan Philip Plog","author_link":"https:\/\/admin.acceleratingscience.com\/author\/jan-plogthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":10,"name":"Mineral Processing","slug":"mineral-processing","term_group":0,"term_taxonomy_id":10,"taxonomy":"category","description":"","parent":0,"count":66,"filter":"raw","meta":[],"cat_ID":10,"category_count":66,"category_description":"","cat_name":"Mineral Processing","category_nicename":"mineral-processing","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":4949,"position":0},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14189,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url_meta":{"origin":4949,"position":1},"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","author":"Marlene Gasdia-Cochrane","date":"November 3, 2026","format":false,"excerpt":"Article Summary Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, mining operations increasingly need to process lower-grade ores with more variable chemical compositions. Handheld X-ray fluorescence (XRF) provides a fast,\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"An aerial view of an open pit phosphate mine","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":4949,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":4949,"position":3},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":4949,"position":4},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":4949,"position":5},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000007415705_medium.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/4949","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/61"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=4949"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/4949\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/9117"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=4949"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=4949"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=4949"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=4949"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}