
{"id":7320,"date":"2016-02-18T08:00:18","date_gmt":"2016-02-18T13:00:18","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=7320"},"modified":"2025-08-21T15:54:24","modified_gmt":"2025-08-21T15:54:24","slug":"what-should-a-coal-analyzer-measure-and-why","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/","title":{"rendered":"What Should a Coal Analyzer Measure? And Why?"},"content":{"rendered":"<p><a href=\"http:\/\/www.thermoscientific.com\/content\/dam\/tfs\/ATG\/CAD\/CAD%20Documents\/Product%20Manuals%20&amp;%20Specifications\/Cement,%20Coal,%20Minerals%20Sampling%20and%20Online%20Analysis\/Coal%20Online%20Elemental%20Analyzers\/TS-ECA-2-spec-sheet.pdf\"><img loading=\"lazy\" decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2016\/02\/coalanalyzer.jpg\" style=\"float: right;border: 0;margin: 10px\" alt=\"coalanalyzer\" title=\"coalanalyzer\" width=\"350\" height=\"193\" \/>Elemental crossbelt analyzers<\/a> provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control. With a elemental analyzer, one can control quality, make pro-active control decisions and improve the efficiency of the operation.<\/p>\n<p>An elemental <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/cqm-flex-coal-analyzer.html\">coal analyzer<\/a> is a specialized analyzer that is utilized by coal-fired power plants and coal producers to help proactively address process variations and ensure more consistent coal blends and improved fuel quality.&nbsp; In the coal blending process, different quality coals are mixed after they are mined to meet the specifications needed for the intended application. It is important that the blended coal meet quality specifications because blending decisions impact the total amount of each product that a mine site is able to sell, and the quality attributes of a product can impact the final sale value of the product, and the satisfaction of the customer.<\/p>\n<p>According to the <a href=\"https:\/\/www.worldcoal.org\/coal\/what-coal\">World Coal Association,<\/a> coal (which is a fossile fuel), is a<\/p>\n<p style=\"padding-left: 30px\">&ldquo;combustible, sedimentary, organic rock, which is composed mainly of carbon, hydrogen and oxygen. It is formed from vegetation, which has been consolidated between other rock strata and altered by the combined effects of pressure and heat over millions of years to form coal seams&#8230;.<\/p>\n<p style=\"padding-left: 30px\">The quality of each coal deposit is determined by:<\/p>\n<ul style=\"padding-left: 30px\">\n<ul>\n<li>Types of vegetation from which the coal originated<\/li>\n<li>Depths of burial<\/li>\n<li>Temperatures and pressures at those depths<\/li>\n<li>Length of time the coal has been forming in the deposit<\/li>\n<\/ul>\n<\/ul>\n<p style=\"padding-left: 30px\">In addition to carbon, coals contain hydrogen, oxygen, nitrogen and varying amounts of sulphur. High-rank coals are high in carbon and therefore heat value, but low in hydrogen and oxygen. Low-rank coals are low in carbon but high in hydrogen and oxygen content. Different types of coal also have different uses&#8230;. [including] electricity generation, steel production, cement manufacturing, and other industrial processes, and as a liquid fuel.&rdquo;<\/p>\n<p>The analyzer usually incorporates either <a href=\"http:\/\/admin.acceleratingscience.com\/mining\/pgnaa-improves-process-and-quality-control-in-cement-production\/\">Prompt Gamma Neutron Activation (PGNAA)<\/a> or Pulsed Fast Thermal Neutron Activation (PFTNA) technology, and is designed to mount around an existing conveyor belt or inline with a sampling system, and analyze the composition of the coal in real-time. The sample stream analyzer should be designed to accept feed from a sample system, control the flow through the analyzer and measure the major coal quality parameters of interest to coal producers and coal-fired power generators.<\/p>\n<p>In addition to carbon and oxygen, there are a dozen other major items of interest that should be measured and reported upon as the coal moves along the conveyor.&nbsp; They include these items as well:<\/p>\n<p><img decoding=\"async\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2016\/02\/coalelements.jpg\" style=\"margin-left: auto;margin-right: auto\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Besides analyzing the coal, a coal quality manager system should automatically calculate:<\/p>\n<ul>\n<li>Heating Value (kcal\/kg, kJ\/kg or BTU\/lb)<\/li>\n<li>Lbs SO2 per million BTU<\/li>\n<li>Volatile Matter<\/li>\n<li>Fixed Carbon<\/li>\n<li>Ash Fusion Temperature (based on customer specific empirical relations)<\/li>\n<\/ul>\n<p>Knowing these measurements in real-time enables coal producers to control sorting and blending of coals to maximize coal resources, meet quality specifications, reduce shipment variability, control ash fusion, and control preparation plant performance. Having this information is especially important to the coal producers and utilities where real-time knowledge of coal quality is critical, including applications such as load outs, truck and rail receipted coal using auger samplers, and at power plants for &ldquo;as received&rdquo; and &ldquo;as fired&rdquo; applications.<\/p>\n<p>Knowing these results can help extend the life of the mine because coal suppliers can mine lower quality coals and then blend coals of varying quality together to meet customer requirements. In fact, quality coal blends that meet specific needs can help the environment and the bottom line.&nbsp; Boiler efficiency can be increased when they are fed a consistent coal blend quality.&nbsp; In addition, coal consumption is reduced, harmful gas emissions are lessened, maintenance is minimized, and unplanned outages are avoided. Those measurements can help coal producers reduce pollutants and help the environment. Most importantly, earth&rsquo;s finite resources are used more efficiently.<\/p>\n<p>You can see how these coal online elemental analyzers control waste, cost, and environmental impact in this <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/cqm-flex-coal-analyzer.html\">6-minute video<\/a> (scroll to the bottom and click on the <em>Discover the CQM Flex Coal Quality Manager<\/em> box.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control. With a elemental analyzer, one can control quality, make pro-active control decisions and improve the efficiency of the operation. An elemental coal analyzer is a specialized analyzer that is utilized by coal-fired power plants and coal<\/p>\n","protected":false},"author":67,"featured_media":9414,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[9],"tags":[],"division":[],"class_list":{"0":"post-7320","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-coal","8":"entry"},"_selected_authors":[768],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>What Should a Coal Analyzer Measure? And Why?<\/title>\n<meta name=\"description\" content=\"Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"What Should a Coal Analyzer Measure? And Why?\" \/>\n<meta property=\"og:description\" content=\"Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-02-18T13:00:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-21T15:54:24+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"288\" \/>\n\t<meta property=\"og:image:height\" content=\"335\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kevin Gordon\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kevin Gordon\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/\"},\"author\":{\"name\":\"Kevin Gordon\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/be5eaada096c7f4069deb122e5572bdb\"},\"headline\":\"What Should a Coal Analyzer Measure? And Why?\",\"datePublished\":\"2016-02-18T13:00:18+00:00\",\"dateModified\":\"2025-08-21T15:54:24+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/\"},\"wordCount\":697,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/coalelements.jpg\",\"articleSection\":[\"Coal\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/\",\"name\":\"What Should a Coal Analyzer Measure? And Why?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/coalelements.jpg\",\"datePublished\":\"2016-02-18T13:00:18+00:00\",\"dateModified\":\"2025-08-21T15:54:24+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/be5eaada096c7f4069deb122e5572bdb\"},\"description\":\"Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/coalelements.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/coalelements.jpg\",\"width\":288,\"height\":335,\"caption\":\"List of elements once can find in coal\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/what-should-a-coal-analyzer-measure-and-why\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Should a Coal Analyzer Measure? And Why?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/be5eaada096c7f4069deb122e5572bdb\",\"name\":\"Kevin Gordon\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/66a7b9e44cfcec673ac389936fa2ee4e44047342acbb761c3bddd0031ec82240?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/66a7b9e44cfcec673ac389936fa2ee4e44047342acbb761c3bddd0031ec82240?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/66a7b9e44cfcec673ac389936fa2ee4e44047342acbb761c3bddd0031ec82240?s=96&d=mm&r=g\",\"caption\":\"Kevin Gordon\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kevin-gordonthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"What Should a Coal Analyzer Measure? And Why?","description":"Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/","og_locale":"en_US","og_type":"article","og_title":"What Should a Coal Analyzer Measure? And Why?","og_description":"Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-02-18T13:00:18+00:00","article_modified_time":"2025-08-21T15:54:24+00:00","og_image":[{"width":288,"height":335,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg","type":"image\/jpeg"}],"author":"Kevin Gordon","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Kevin Gordon","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/"},"author":{"name":"Kevin Gordon","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/be5eaada096c7f4069deb122e5572bdb"},"headline":"What Should a Coal Analyzer Measure? And Why?","datePublished":"2016-02-18T13:00:18+00:00","dateModified":"2025-08-21T15:54:24+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/"},"wordCount":697,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg","articleSection":["Coal"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/","name":"What Should a Coal Analyzer Measure? And Why?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg","datePublished":"2016-02-18T13:00:18+00:00","dateModified":"2025-08-21T15:54:24+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/be5eaada096c7f4069deb122e5572bdb"},"description":"Elemental crossbelt analyzers provide minute-by-minute quality analysis of critical process streams to facilitate sorting, blending and out-of-seam dilution control.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg","width":288,"height":335,"caption":"List of elements once can find in coal"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/what-should-a-coal-analyzer-measure-and-why\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"What Should a Coal Analyzer Measure? And Why?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/be5eaada096c7f4069deb122e5572bdb","name":"Kevin Gordon","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/66a7b9e44cfcec673ac389936fa2ee4e44047342acbb761c3bddd0031ec82240?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/66a7b9e44cfcec673ac389936fa2ee4e44047342acbb761c3bddd0031ec82240?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/66a7b9e44cfcec673ac389936fa2ee4e44047342acbb761c3bddd0031ec82240?s=96&d=mm&r=g","caption":"Kevin Gordon"},"url":"https:\/\/admin.acceleratingscience.com\/author\/kevin-gordonthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":9,"label":"Coal"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg",288,335,false],"author_info":{"display_name":"Kevin Gordon","author_link":"https:\/\/admin.acceleratingscience.com\/author\/kevin-gordonthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Coal","slug":"coal","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":78,"filter":"raw","meta":[],"cat_ID":9,"category_count":78,"category_description":"","cat_name":"Coal","category_nicename":"coal","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":14123,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-coal-chemistry-matters-in-coal-fired-power-generation\/","url_meta":{"origin":7320,"position":0},"title":"Why Coal Chemistry Matters in Coal-Fired Power Generation\u00a0","author":"Marlene Gasdia-Cochrane","date":"July 28, 2026","format":false,"excerpt":"Summary For coal manufacturers, product quality extends far beyond tonnage and\u00a0logistics. The chemical characteristics of coal directly influence power plant efficiency, emissions performance, maintenance requirements, and overall operating costs. As utilities continue to focus on fuel optimization and regulatory compliance, understanding coal chemistry has become essential for suppliers\u00a0seeking\u00a0to deliver value\u2026","rel":"","context":"In &quot;Coal&quot;","block_context":{"text":"Coal","link":"https:\/\/admin.acceleratingscience.com\/mining\/coal\/"},"img":{"alt_text":"Stone coal lump in scientist hand","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":7320,"position":1},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1624,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/a-halloween-treat-free-periodic-table\/","url_meta":{"origin":7320,"position":2},"title":"A Halloween Treat &#8211; Free Periodic Table","author":"Marlene Gasdia-Cochrane","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your mining samples. \u00a0It's our treat. Then visit our Mining and Minerals, Cement Production, and Coal Power pages for more goodies. Download Periodic Table.\u00a0 \u00a0","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"halloween scene with plastic pumpkin and candy","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":7320,"position":3},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14089,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-real-time-monitoring-is-transforming-refined-fuel-quality-control\/","url_meta":{"origin":7320,"position":4},"title":"Why Real-Time Monitoring Is Transforming Refined Fuel Quality Control","author":"Marlene Gasdia-Cochrane","date":"July 21, 2026","format":false,"excerpt":"Article Summary Refinery operations depend on precise control of fuel properties. Whether producing gasoline, diesel, jet fuel, or base oils, even small variations can impact product performance, regulatory compliance, and profitability. Traditionally, fuel quality has been verified through a combination of laboratory testing and online analyzers. While these methods are\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Aerial view of oil refinery and storage tanks at dusk and night, showcasing energy industry infrastructure, petroleum processing, and industrial landscape.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":7320,"position":5},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/coalelements.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/7320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/67"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=7320"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/7320\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/9414"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=7320"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=7320"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=7320"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=7320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}