
{"id":7971,"date":"2016-03-22T08:00:55","date_gmt":"2016-03-22T12:00:55","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=7971"},"modified":"2026-02-06T21:34:00","modified_gmt":"2026-02-06T21:34:00","slug":"is-your-coal-retaining-moisture","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/","title":{"rendered":"Is Your Coal Retaining Moisture?"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right;border: 0;margin: 10px\" title=\"Is Your Coal Retaining Moisture\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2016\/03\/istock_000003681293_medium-1.jpg\" alt=\"Is Your Coal Retaining Moisture\" width=\"400\" height=\"266\" \/>Coal begins as peat, which consists of loosely consolidated layers of various mixtures of plant and mineral matter that has accumulated in wetlands.\u00a0 The <a href=\"http:\/\/pubs.usgs.gov\/circ\/c1143\/html\/text.html\">U.S. Geological Survey<\/a> (USGS) describes the origin of coal as follows: \u201cMillions of years, burial, compression by overlying inorganic sediments, and the effects of heat (from depth in the earth or proximity to volcanic sources) cause peat to change to coal. The resultant coal is an extremely complex, mostly organic, generally well bedded sedimentary rock.\u201d<\/p>\n<p>Because that coal originated in wetlands, it can contain little or lots of moisture by the time it is mined.\u00a0 And the amount of moisture present in the coal dictates how the coal will be used.\u00a0 A USGS example explains that lignite is soft, dusty, and can ignite spontaneously under the appropriate conditions, whereas anthracite is quite hard, clean to the touch, and must reach a temperature of about 925\u00b0F before it will ignite. Lignite contains more moisture and oxygen and less fixed carbon than anthracite. Subbituminous and high-volatile bituminous C coals have oxygen and moisture content and calorific values that range between those of lignite and anthracite.<\/p>\n<p>The <a href=\"https:\/\/lignite.com\/\">Lignite Energy Council<\/a> reports that \u201cAbout 79 percent of lignite coal is used to generate electricity, 13.5 percent is used to generate synthetic natural gas, and 7.5 percent is used to produce fertilizer products (anhydrous ammonia &amp; ammonium sulfate). A very small percentage is used as home heating fuel, for use as fertilizer and for use as oil well drilling mud.\u201d \u00a0Anthracite coal, on the other hand, is a hard, glossy black coal that is used for home heating and steel making.<\/p>\n<p>Mining companies know that moisture content is critical to the coal\u2019s application, which is paramount to meeting customer requirements.\u00a0 For example, <a href=\"http:\/\/www.thermoscientific.com\/content\/dam\/tfs\/ATG\/CAD\/CAD%20Documents\/Product%20Manuals%20&amp;%20Specifications\/Online%20Process%20Analyzers\/Gas%20Moisture%20and%20Sulfur%20Analyzers\/D02419~.pdf\">moisture analysis for mining applications<\/a> is needed for:<\/p>\n<ul>\n<li>Dust reduction by preconditioning bulk minerals with water addition. The key challenge is to add just enough water to achieve dust extinction but not so much that the ore becomes sticky and clogs chutes and blinds screens.<\/li>\n<li>Transportable Moisture Limit (TML) for shipment, both for the customers and the shipping operators.<\/li>\n<li>Feed forward control in critical drying or calcining applications.<\/li>\n<li>Moisture compensation for accurate metallurgical accounting.<\/li>\n<li>Control of critical moisture levels in pelletizing and sintering applications.<\/li>\n<li>Moisture specification monitoring in thermal power applications.<\/li>\n<li>Control of filter presses and centrifuges in dewatering applications.<\/li>\n<\/ul>\n<p><a href=\"http:\/\/www.thermoscientific.com\/en\/product\/lfm-sub-3-sub-moisture-analyzer.html\">Microwave moisture analyzers<\/a> work on the principle that water has a very high dielectric constant compared to most other materials. When microwaves intersect with water molecules within the material they slow down (and hence change phase) and weaken (attenuate) as the energy is transferred to the material. A <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/lfm-sub-3-sub-moisture-analyzer.html\">Low Frequency Microwave (LFM<sub>3<\/sub>) moisture analyzer<\/a> has a low profile antenna, which transmits a low frequency signal through the material on the conveyor belt. The signal is received by a receiver antenna located below the conveyor belt. The received signal is compared to the transmitted signal for phase and amplitude change. This helps ensure accurate measurement of all material between antenna pair in difficult applications where vertical material segregation occurs. The first microwave based moisture content analyzers used only one characteristic of the microwave \u2013 the attenuation. Nowadays, most free moisture content analyzers use both attenuation and phase shift techniques.<\/p>\n<p>The key to providing customers with the right amount of free moisture is getting an accurate analysis of the free moisture in the coal. When you are processing coal, too much liquid can cause safety hazards, machinery breakage, and loss of customers.<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Coal begins as peat, which consists of loosely consolidated layers of various mixtures of plant and mineral matter that has accumulated in wetlands.\u00a0 The U.S. Geological Survey (USGS) describes the origin of coal as follows: \u201cMillions of years, burial, compression by overlying inorganic sediments, and the effects of heat (from depth in the earth or<\/p>\n","protected":false},"author":72,"featured_media":9456,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[9],"tags":[],"division":[],"class_list":["post-7971","post","type-post","status-publish","format-standard","has-post-thumbnail","category-coal","entry"],"_selected_authors":[1355],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Is Your Coal Retaining Moisture?<\/title>\n<meta name=\"description\" content=\"Microwave moisture analyzers work on the principle that water has a very high dielectric constant compared to most other materials. Read how it affects coal.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Is Your Coal Retaining Moisture?\" \/>\n<meta property=\"og:description\" content=\"Microwave moisture analyzers work on the principle that water has a very high dielectric constant compared to most other materials. Read how it affects coal.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-22T12:00:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-02-06T21:34:00+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1700\" \/>\n\t<meta property=\"og:image:height\" content=\"1129\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Stephan Nel\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Stephan Nel\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/\"},\"author\":{\"name\":\"Stephan Nel\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/a1c2a080dd67b7e154c3d681537c0d27\"},\"headline\":\"Is Your Coal Retaining Moisture?\",\"datePublished\":\"2016-03-22T12:00:55+00:00\",\"dateModified\":\"2026-02-06T21:34:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/\"},\"wordCount\":585,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000003681293_medium-1.jpg\",\"articleSection\":[\"Coal\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/\",\"name\":\"Is Your Coal Retaining Moisture?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000003681293_medium-1.jpg\",\"datePublished\":\"2016-03-22T12:00:55+00:00\",\"dateModified\":\"2026-02-06T21:34:00+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/a1c2a080dd67b7e154c3d681537c0d27\"},\"description\":\"Microwave moisture analyzers work on the principle that water has a very high dielectric constant compared to most other materials. Read how it affects coal.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000003681293_medium-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/04\\\/istock_000003681293_medium-1.jpg\",\"width\":1700,\"height\":1129,\"caption\":\"Is Your Coal Retaining Moisture\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/is-your-coal-retaining-moisture\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Is Your Coal Retaining Moisture?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/a1c2a080dd67b7e154c3d681537c0d27\",\"name\":\"Stephan Nel\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g\",\"caption\":\"Stephan Nel\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/stephan-nelthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Is Your Coal Retaining Moisture?","description":"Microwave moisture analyzers work on the principle that water has a very high dielectric constant compared to most other materials. Read how it affects coal.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/","og_locale":"en_US","og_type":"article","og_title":"Is Your Coal Retaining Moisture?","og_description":"Microwave moisture analyzers work on the principle that water has a very high dielectric constant compared to most other materials. Read how it affects coal.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-03-22T12:00:55+00:00","article_modified_time":"2026-02-06T21:34:00+00:00","og_image":[{"width":1700,"height":1129,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg","type":"image\/jpeg"}],"author":"Stephan Nel","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Stephan Nel","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/"},"author":{"name":"Stephan Nel","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/a1c2a080dd67b7e154c3d681537c0d27"},"headline":"Is Your Coal Retaining Moisture?","datePublished":"2016-03-22T12:00:55+00:00","dateModified":"2026-02-06T21:34:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/"},"wordCount":585,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg","articleSection":["Coal"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/","name":"Is Your Coal Retaining Moisture?","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg","datePublished":"2016-03-22T12:00:55+00:00","dateModified":"2026-02-06T21:34:00+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/a1c2a080dd67b7e154c3d681537c0d27"},"description":"Microwave moisture analyzers work on the principle that water has a very high dielectric constant compared to most other materials. Read how it affects coal.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg","width":1700,"height":1129,"caption":"Is Your Coal Retaining Moisture"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/is-your-coal-retaining-moisture\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Is Your Coal Retaining Moisture?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/a1c2a080dd67b7e154c3d681537c0d27","name":"Stephan Nel","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c0ba4043c499c8af70212884b7c1bf9af8a121158baabafe6da9bf2a036b99b9?s=96&d=mm&r=g","caption":"Stephan Nel"},"url":"https:\/\/admin.acceleratingscience.com\/author\/stephan-nelthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":9,"label":"Coal"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1-1024x680.jpg",760,505,true],"author_info":{"display_name":"Stephan Nel","author_link":"https:\/\/admin.acceleratingscience.com\/author\/stephan-nelthermofisher-com\/"},"comment_info":1,"category_info":[{"term_id":9,"name":"Coal","slug":"coal","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":78,"filter":"raw","meta":[],"cat_ID":9,"category_count":78,"category_description":"","cat_name":"Coal","category_nicename":"coal","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":14123,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-coal-chemistry-matters-in-coal-fired-power-generation\/","url_meta":{"origin":7971,"position":0},"title":"Why Coal Chemistry Matters in Coal-Fired Power Generation\u00a0","author":"Marlene Gasdia-Cochrane","date":"July 28, 2026","format":false,"excerpt":"Summary For coal manufacturers, product quality extends far beyond tonnage and\u00a0logistics. The chemical characteristics of coal directly influence power plant efficiency, emissions performance, maintenance requirements, and overall operating costs. As utilities continue to focus on fuel optimization and regulatory compliance, understanding coal chemistry has become essential for suppliers\u00a0seeking\u00a0to deliver value\u2026","rel":"","context":"In &quot;Coal&quot;","block_context":{"text":"Coal","link":"https:\/\/admin.acceleratingscience.com\/mining\/coal\/"},"img":{"alt_text":"Stone coal lump in scientist hand","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-1371922462_coallab.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":7971,"position":1},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":7971,"position":2},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14155,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-process-mass-spectrometry-based-on-line-gas-analysis-supports-compressed-biogas-quality-and-process-monitoring\/","url_meta":{"origin":7971,"position":3},"title":"How Process Mass Spectrometry-based On-line Gas Analysis Supports Compressed Biogas Quality and Process Monitoring","author":"Marlene Gasdia-Cochrane","date":"October 6, 2026","format":false,"excerpt":"Article Summary Compressed biogas (CBG) production requires continuous monitoring of gas composition from raw biogas through upgrading to final biomethane quality. Online gas analysis using process mass spectrometry provides real-time, multicomponent measurements that can help operators monitor methane, carbon dioxide, moisture, sulfur compounds and methane slip while improving visibility into\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Biogas production, biogas plant, bio power","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14189,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url_meta":{"origin":7971,"position":4},"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","author":"Marlene Gasdia-Cochrane","date":"November 3, 2026","format":false,"excerpt":"Article Summary Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, mining operations increasingly need to process lower-grade ores with more variable chemical compositions. Handheld X-ray fluorescence (XRF) provides a fast,\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"An aerial view of an open pit phosphate mine","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/04\/istock_000003681293_medium-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/7971","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/72"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=7971"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/7971\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/9456"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=7971"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=7971"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=7971"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=7971"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}