
{"id":9722,"date":"2016-06-28T12:00:59","date_gmt":"2016-06-28T12:00:59","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/mining\/?p=9722"},"modified":"2026-08-19T13:33:05","modified_gmt":"2026-08-19T13:33:05","slug":"phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/","title":{"rendered":"Phytomining: Harvesting Germanium May Provide a New Source of this Metal"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: right;border: 0;margin: 10px\" title=\"Germanium and sunflowers\" src=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg\" alt=\"Germanium and sunflowers\" width=\"400\" height=\"266\" \/>What do sunflowers, corn, and cell phones have in common? The element Germanium (Ge). This semi-metallic element is widely used in semiconductors incorporated into computers, cell phones, and fiber optic cables. Germanium is also used in smart steering systems and parking sensors because it is transparent in infra-red light. And soon it may be sourced from sunflowers, corn, and other crops.<\/p>\n<p>Germanium is abundant but difficult to mine.\u00a0 Most germanium is recovered as a byproduct of zinc ore (sphalerite) processing, and occasionally from\u00a0silver,\u00a0lead, and\u00a0copper\u00a0ores. According to the <a href=\"http:\/\/minerals.usgs.gov\/minerals\/pubs\/commodity\/germanium\/mcs-2016-germa.pdf\">U.S. Geological Survey\u2019s 2016 Germanium Mineral Commodity Summary<\/a>, U.S. reserves of zinc may contain as much as 2,500 tons of germanium, but because zinc concentrates are shipped globally and blended at smelters, the recoverable germanium in zinc reserves cannot be determined. On a global scale, as little as 3% of the germanium contained in zinc concentrates is recovered.<\/p>\n<p>Like <a href=\"http:\/\/admin.acceleratingscience.com\/mining\/can-you-name-all-17-rare-earth-elements\/\">rare earth elements<\/a> (REEs), most germanium is exported from China, and demand for it is expected to grow. Luckily, scientists at Freiburg University of Mining and Technology may have found an alternative source through phytomining, or \u201cmining with plants.\u201d<\/p>\n<p>According to the Reuters article, <a href=\"http:\/\/www.reuters.com\/article\/us-germany-germanium-plants-idUSKCN0R71BY20150907\">Smart phone ingredient found in plant extracts<\/a>, certain crops, including sunflowers, corn, reed canary grass, are able to absorb germanium from the soil. And because these plants are already being processed for use as biogas, extracting the germanium may prove economical. One of the scientists working on the project explains, &#8220;There is zinc ore present here, the ground is very rich in zinc. We have the remains of waste rock piles from mining, which germanium-rich water can drain better through. And when you cultivate plants here and give them that water, they can build up germanium reserves through normal physiological processes. We unlock these reserves through fermentation with the help of bacteria and thus we are able to mobilize the germanium.&#8221;<\/p>\n<p>If it comes to fruition, phytomining will be a vast departure from traditional mining and exploration processes, which may include outcrop and soil analysis, advanced exploration and drilling, core sample analysis, mine mapping, ore trading, grade control, and cuttings analysis for mud logging and reservoir characterization, and oil and gas exploration and production (E&amp;P). Both lab-based and <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/spectroscopy-elemental-isotope-analysis\/portable-analysis-material-id\/portable-mining-exploration-solutions.html\">portable XRF solutions<\/a> are making a critical difference in these mining operations, and the <a href=\"http:\/\/admin.acceleratingscience.com\/mining\/\">Advancing Mining<\/a> blog offers many posts on various applications for these technologies.<\/p>\n<p><em>If you\u2019re more interested in new and emerging or non-traditional mining technologies and developments, we offer the following articles:<\/em><\/p>\n<ul>\n<li><a href=\"http:\/\/admin.acceleratingscience.com\/mining\/3d-printing-in-space-bringing-asteroid-mining-one-step-closer-to-reality\/\">3D Printing in Space: Bringing Asteroid Mining One Step Closer to Reality<\/a><\/li>\n<li><a href=\"http:\/\/admin.acceleratingscience.com\/mining\/minings-industrial-internet-connecting-the-dots\/\">Mining\u2019s Industrial Internet: Connecting the Dots<\/a><\/li>\n<li><a href=\"http:\/\/admin.acceleratingscience.com\/mining\/mining-automation-what-does-the-future-hold\/\">Mining Automation: What Does the Future Hold?<\/a><\/li>\n<li><a href=\"http:\/\/admin.acceleratingscience.com\/mining\/green-mining-can-it-really-happen-part-2\/\">Green Mining: Can It Really Happen? Part 2<\/a><\/li>\n<li><a href=\"http:\/\/admin.acceleratingscience.com\/mining\/from-tailings-to-treasure-a-new-mother-lode\/\">From Tailings to Treasure? A New Mother Lode<\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>What do sunflowers, corn, and cell phones have in common? The element Germanium (Ge). This semi-metallic element is widely used in semiconductors incorporated into computers, cell phones, and fiber optic cables. Germanium is also used in smart steering systems and parking sensors because it is transparent in infra-red light. And soon it may be sourced<\/p>\n","protected":false},"author":70,"featured_media":9786,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[4],"tags":[],"division":[],"class_list":["post-9722","post","type-post","status-publish","format-standard","has-post-thumbnail","category-exploration","entry"],"_selected_authors":[1288],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Phytomining: Harvesting Germanium May Provide a New Source of this Metal - Advancing Mining<\/title>\n<meta name=\"description\" content=\"Explore how phytomining could provide a new source of germanium by using plants to extract this valuable metal from soil and support future supply needs.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Phytomining: Harvesting Germanium May Provide a New Source of this Metal\" \/>\n<meta property=\"og:description\" content=\"Explore how phytomining could provide a new source of germanium by using plants to extract this valuable metal from soil and support future supply needs.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-28T12:00:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-19T13:33:05+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1698\" \/>\n\t<meta property=\"og:image:height\" content=\"1131\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Chris Calam\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Chris Calam\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/\"},\"author\":{\"name\":\"Chris Calam\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/5b7849d9c50120c808cb077b65fe9a52\"},\"headline\":\"Phytomining: Harvesting Germanium May Provide a New Source of this Metal\",\"datePublished\":\"2016-06-28T12:00:59+00:00\",\"dateModified\":\"2026-08-19T13:33:05+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/\"},\"wordCount\":472,\"commentCount\":6,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/06\\\/istock_000073705729_sunflowers-2.jpg\",\"articleSection\":[\"Exploration\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/\",\"name\":\"Phytomining: Harvesting Germanium May Provide a New Source of this Metal - Advancing Mining\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/06\\\/istock_000073705729_sunflowers-2.jpg\",\"datePublished\":\"2016-06-28T12:00:59+00:00\",\"dateModified\":\"2026-08-19T13:33:05+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/5b7849d9c50120c808cb077b65fe9a52\"},\"description\":\"Explore how phytomining could provide a new source of germanium by using plants to extract this valuable metal from soil and support future supply needs.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/06\\\/istock_000073705729_sunflowers-2.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/06\\\/istock_000073705729_sunflowers-2.jpg\",\"width\":1698,\"height\":1131,\"caption\":\"Germanium and sunflowers\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Phytomining: Harvesting Germanium May Provide a New Source of this Metal\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/5b7849d9c50120c808cb077b65fe9a52\",\"name\":\"Chris Calam\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g\",\"caption\":\"Chris Calam\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/chris-calamthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Phytomining: Harvesting Germanium May Provide a New Source of this Metal - Advancing Mining","description":"Explore how phytomining could provide a new source of germanium by using plants to extract this valuable metal from soil and support future supply needs.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/","og_locale":"en_US","og_type":"article","og_title":"Phytomining: Harvesting Germanium May Provide a New Source of this Metal","og_description":"Explore how phytomining could provide a new source of germanium by using plants to extract this valuable metal from soil and support future supply needs.","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-06-28T12:00:59+00:00","article_modified_time":"2026-08-19T13:33:05+00:00","og_image":[{"width":1698,"height":1131,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg","type":"image\/jpeg"}],"author":"Chris Calam","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Chris Calam","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/"},"author":{"name":"Chris Calam","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/5b7849d9c50120c808cb077b65fe9a52"},"headline":"Phytomining: Harvesting Germanium May Provide a New Source of this Metal","datePublished":"2016-06-28T12:00:59+00:00","dateModified":"2026-08-19T13:33:05+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/"},"wordCount":472,"commentCount":6,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg","articleSection":["Exploration"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/","name":"Phytomining: Harvesting Germanium May Provide a New Source of this Metal - Advancing Mining","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg","datePublished":"2016-06-28T12:00:59+00:00","dateModified":"2026-08-19T13:33:05+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/5b7849d9c50120c808cb077b65fe9a52"},"description":"Explore how phytomining could provide a new source of germanium by using plants to extract this valuable metal from soil and support future supply needs.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg","width":1698,"height":1131,"caption":"Germanium and sunflowers"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/phytomining-harvesting-germanium-may-provide-a-new-source-of-this-metal\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Phytomining: Harvesting Germanium May Provide a New Source of this Metal"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/5b7849d9c50120c808cb077b65fe9a52","name":"Chris Calam","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/8f5fd32e65c3e407a57f3bd975091000dfc9275cbb2c44fc4cf24d6417918d18?s=96&d=mm&r=g","caption":"Chris Calam"},"url":"https:\/\/admin.acceleratingscience.com\/author\/chris-calamthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":4,"label":"Exploration"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2-1024x682.jpg",760,506,true],"author_info":{"display_name":"Chris Calam","author_link":"https:\/\/admin.acceleratingscience.com\/author\/chris-calamthermofisher-com\/"},"comment_info":108,"category_info":[{"term_id":4,"name":"Exploration","slug":"exploration","term_group":0,"term_taxonomy_id":4,"taxonomy":"category","description":"","parent":0,"count":151,"filter":"raw","meta":[],"cat_ID":4,"category_count":151,"category_description":"","cat_name":"Exploration","category_nicename":"exploration","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":14189,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/understanding-xrf-testing-for-phosphate-ore-quality-and-elemental-composition\/","url_meta":{"origin":9722,"position":0},"title":"Understanding XRF Testing for Phosphate Ore Quality and Elemental Composition","author":"Marlene Gasdia-Cochrane","date":"November 3, 2026","format":false,"excerpt":"Article Summary Phosphate ore is the primary source of phosphorus used in fertilizers, making reliable phosphate analysis important to global agriculture and food production. As higher-grade deposits become less available, mining operations increasingly need to process lower-grade ores with more variable chemical compositions. Handheld X-ray fluorescence (XRF) provides a fast,\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"An aerial view of an open pit phosphate mine","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-177760247_phosphatemine.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":9722,"position":1},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":9722,"position":2},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13977,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/what-is-in-situ-geochemical-analysis-and-why-it-is-critical-for-modern-field-operations\/","url_meta":{"origin":9722,"position":3},"title":"What Is In Situ Geochemical Analysis \u2014 And Why It Is Critical for Modern Field Operations","author":"Marlene Gasdia-Cochrane","date":"March 13, 2026","format":false,"excerpt":"In situ geochemical analysis has become a cornerstone of modern mineral exploration, mining, and environmental fieldwork. As project timelines tighten and operational costs increase, organizations can no longer afford delays caused by traditional laboratory testing workflows. In situ analysis \u2014 the ability to measure elemental composition directly at the sampling\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Close up of industrial worker holding mineral ore in gloved hands on mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-896157842.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":13986,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/best-practices-for-accurate-in-situ-geochemical-analysis\/","url_meta":{"origin":9722,"position":4},"title":"Best Practices for Accurate In Situ Geochemical Analysis","author":"Marlene Gasdia-Cochrane","date":"March 24, 2026","format":false,"excerpt":"In situ geochemical analysis refers to elemental testing performed directly on geological materials in their natural location, avoiding the delays and costs associated with laboratory testing.\u00a0 While in situ geochemical analysis delivers immediate elemental data, the reliability of those results depends heavily on proper field methodology. Portable analytical technologies used\u2026","rel":"","context":"In &quot;Exploration&quot;","block_context":{"text":"Exploration","link":"https:\/\/admin.acceleratingscience.com\/mining\/exploration\/"},"img":{"alt_text":"Mining truck on a dirt road in the Andes, Chile (near Embalse El Yeso, Caj\u00f3n del Maipo, San Jos\u00e9 de Maipo)","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/03\/iStock-2222354034.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14089,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-real-time-monitoring-is-transforming-refined-fuel-quality-control\/","url_meta":{"origin":9722,"position":5},"title":"Why Real-Time Monitoring Is Transforming Refined Fuel Quality Control","author":"Marlene Gasdia-Cochrane","date":"July 21, 2026","format":false,"excerpt":"Article Summary Refinery operations depend on precise control of fuel properties. Whether producing gasoline, diesel, jet fuel, or base oils, even small variations can impact product performance, regulatory compliance, and profitability. Traditionally, fuel quality has been verified through a combination of laboratory testing and online analyzers. While these methods are\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Aerial view of oil refinery and storage tanks at dusk and night, showcasing energy industry infrastructure, petroleum processing, and industrial landscape.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/06\/istock_000073705729_sunflowers-2.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/9722","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/70"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=9722"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/9722\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/9786"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=9722"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=9722"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=9722"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=9722"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}