
{"id":9975,"date":"2016-12-06T13:01:03","date_gmt":"2016-12-06T13:01:03","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/mining\/?p=9975"},"modified":"2026-01-06T20:50:10","modified_gmt":"2026-01-06T20:50:10","slug":"question-about-limestone-and-clay-blending-in-cement-production","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/","title":{"rendered":"Question About Limestone and Clay Blending in Cement Production"},"content":{"rendered":"<p><span style=\"font-size: 12pt\">We recently received an inquiry from one of our readers regarding the blog post\u00a0<em><a href=\"http:\/\/admin.acceleratingscience.com\/mining\/pgnaa-improves-process-and-quality-control-in-cement-production\/\" target=\"_blank\" rel=\"noopener noreferrer\">PGNAA Improves Process and Quality Control in Cement Production<\/a>\u00a0<\/em>in regard to using a <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/CBOMNIFUSION\" target=\"_blank\" rel=\"noopener noreferrer\">CrossBelt online analyzer<\/a>\u00a0for process control.\u00a0Here&#8217;s the question:<\/span><\/p>\n<p><span style=\"font-size: 12pt\"><img loading=\"lazy\" decoding=\"async\" style=\"float: right;border: 0;margin: 10px\" title=\"cement production worker\" src=\"http:\/\/www.thermofisher.com\/blog\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg\" alt=\"cement production worker\" width=\"500\" height=\"233\" \/><span style=\"font-size: 14pt\">Question: \u00a0<\/span><\/span><\/p>\n<p><span style=\"font-size: 12pt\">If\u00a0we blend with two types of materials, such as limestone and clay, what parameter is used for control in the pile? \u00a0<\/span><\/p>\n<p><span style=\"font-size: 14pt\">Answer:<\/span><\/p>\n<p><span style=\"font-size: 12pt\">If you have only two distinct materials available, without much chemistry variation within those two material types, then in general terms, a single quality control parameter, such as Lime Saturation Factor (LSF) or an estimate of Alite (tricalcium silicate) using the Bogue equation for Ca<sub>3<\/sub>SiO<sub>2<\/sub> (C3S), could be used to control the quality of the pile. \u00a0If however, the two raw materials you have available actually have chemistry variations such that the limestone and clay can be considered multiple different types of limestone and multiple different types of clay, then in reality there would be more than two materials available for control. Here are some examples:<\/span><\/p>\n<ol>\n<li><span style=\"font-size: 12pt\">High Grade Limestone<\/span><\/li>\n<li><span style=\"font-size: 12pt\">Low Grade Limestone<\/span><\/li>\n<li><span style=\"font-size: 12pt\">Low Silica\/High Alumina Clay<\/span><\/li>\n<li><span style=\"font-size: 12pt\">High Silica\/Low Alumina Clay<\/span><\/li>\n<li><span style=\"font-size: 12pt\">High Iron Clay<\/span><\/li>\n<li><span style=\"font-size: 12pt\">etc.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-size: 12pt\">This is usually the case within a quarry as typically there are fairly significant chemistry variations across an entire quarry with multiple differing grades of material on different mine benches.<\/span><\/p>\n<p><span style=\"font-size: 12pt\">In general terms, the number of quality control parameters that can be controlled and met, given different materials, follows the function \u201c<strong><em>N-1<\/em><\/strong>\u201d where <strong><em>N =<\/em><\/strong> the number of materials available with different chemistry.\u00a0 So, if only one type of clay is available and one type of limestone is available (two materials) then only one control parameter can be met and controlled.\u00a0<\/span><\/p>\n<p><span style=\"font-size: 12pt\">However, if there are really different types of clay and different types of limestone, then there would really be different materials available and multiple quality control parameters could be met.\u00a0 In an example case where there is:<\/span><\/p>\n<ol>\n<li><span style=\"font-size: 12pt\">High Grade Limestone,<\/span><\/li>\n<li><span style=\"font-size: 12pt\">Low Grade Limestone,<\/span><\/li>\n<li><span style=\"font-size: 12pt\">High Silica\/Low Alumina Clay, and <\/span><\/li>\n<li><span style=\"font-size: 12pt\">High Alumina\/Low Silica Clay <\/span><\/li>\n<\/ol>\n<p><span style=\"font-size: 12pt\">there would actually be four different materials.\u00a0 These four different materials would allow the control of up to three quality control parameters such as:<\/span><\/p>\n<ol>\n<li><span style=\"font-size: 12pt\">Lime Saturation Factor (LSF), <\/span><\/li>\n<li><span style=\"font-size: 12pt\">Silica Modulus (SM) and <\/span><\/li>\n<li><span style=\"font-size: 12pt\">Iron Modulus (IM). <\/span><\/li>\n<\/ol>\n<p><span style=\"font-size: 12pt\">Or, conversely, using Bogue equations:<\/span><\/p>\n<ol>\n<li><span style=\"font-size: 12pt\">C3S, <\/span><\/li>\n<li><span style=\"font-size: 12pt\">C2S and <\/span><\/li>\n<li><span style=\"font-size: 12pt\">C4AF .<\/span><\/li>\n<\/ol>\n<p><span style=\"font-size: 12pt\">The different materials with different chemistry composition could be from different benches in your quarry.\u00a0<\/span><\/p>\n<p><span style=\"font-size: 12pt\">Consistent stockpile and raw mix chemistry is the key to ensuring smooth kiln operation and flexible, controlled quarry operations. An <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/10130687\" target=\"_blank\" rel=\"noopener noreferrer\">online elemental analyzer<\/a> monitors, in real time, the elemental composition of bulk materials along the entire material stream to troubleshoot issues in pre-blending stockpile control\/quarry management, raw mix proportioning control and material sorting. The result is precise control of the raw mix, chemical uniformity of kiln feed, increased kiln efficiency and ultimately superior performance cement.<\/span><\/p>\n<p><span style=\"font-size: 12pt\">If you would like us to take a look at your raw materials and process for a more detailed analysis of what might be able to be accomplished with an online analyzer, please comment below.<\/span><\/p>\n<p><span style=\"font-size: 12pt\">Here&#8217;s some additional reading about online analyzers:<\/span><\/p>\n<ul>\n<li><span style=\"font-size: 12pt\">Scroll down on this page:\u00a0<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html\" target=\"_blank\" rel=\"noopener noreferrer\">Cement Production<\/a>\u00a0to access:<\/span>\n<ul>\n<li><span style=\"font-size: 12pt\">VIDEO: See how an\u00a0Online Elemental Analyzer can help companies achieve high-efficiency cement production through continuous online analysis.<\/span><\/li>\n<li><span style=\"font-size: 12pt\">WEBINAR: \u00a0Watch this recorded webinar\u00a0for a complete overview of how Prompt Gamma Neutron Activation Analysis (PGNAA) and X-ray fluorescence (XRF)\u00a0can work together to provide consistent kiln feed, greater throughput, streamlined processes, and more comprehensive analysis.<\/span>&nbsp;<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n<p><span style=\"font-size: 12pt\">Thank you to our reader and if anyone else has any questions, note it below int the comment section.<\/span><\/p>\n<h2>Visit the<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?cid=cad_cad_vm_cement_sig_blog\"> Cement Production center<\/a> on our website, with free resources to help you optimize your cement making process.<br \/>\n<a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/industrial\/cement-coal-minerals\/cement-production.html?cid=cad_cad_vm_cement_sig_blog\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-11424\" src=\"https:\/\/www.thermofisher.com\/blog\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125.jpg\" alt=\"\" width=\"600\" height=\"125\" srcset=\"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125.jpg 600w, https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2015\/08\/CAD-Cement-E-Signature-Banner-600x125-300x63.jpg 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/a><\/h2>\n","protected":false},"excerpt":{"rendered":"<p>We recently received an inquiry from one of our readers regarding the blog post\u00a0PGNAA Improves Process and Quality Control in Cement Production\u00a0in regard to using a CrossBelt online analyzer\u00a0for process control.\u00a0Here&#8217;s the question: Question: \u00a0 If\u00a0we blend with two types of materials, such as limestone and clay, what parameter is used for control in the<\/p>\n","protected":false},"author":142,"featured_media":10027,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[225],"tags":[],"division":[],"class_list":{"0":"post-9975","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-general","8":"entry"},"_selected_authors":[1211],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Question About Limestone and Clay Blending for Cement Production<\/title>\n<meta name=\"description\" content=\"Question: If we blend with 2 types of materials such as limestone and clay, what parameter is used to control in pile? Here&#039;s the answer...\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Question About Limestone and Clay Blending in Cement Production\" \/>\n<meta property=\"og:description\" content=\"Question: If we blend with 2 types of materials such as limestone and clay, what parameter is used to control in pile? Here&#039;s the answer...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/\" \/>\n<meta property=\"og:site_name\" content=\"Advancing Mining\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-12-06T13:01:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-06T20:50:10+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2028\" \/>\n\t<meta property=\"og:image:height\" content=\"946\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Darrell Leetham\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Darrell Leetham\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/\"},\"author\":{\"name\":\"Darrell Leetham\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/084f4ad87b938d6a238a48082bf2475f\"},\"headline\":\"Question About Limestone and Clay Blending in Cement Production\",\"datePublished\":\"2016-12-06T13:01:03+00:00\",\"dateModified\":\"2026-01-06T20:50:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/\"},\"wordCount\":627,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/12\\\/cementworker.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/\",\"name\":\"Question About Limestone and Clay Blending for Cement Production\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/12\\\/cementworker.jpg\",\"datePublished\":\"2016-12-06T13:01:03+00:00\",\"dateModified\":\"2026-01-06T20:50:10+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/084f4ad87b938d6a238a48082bf2475f\"},\"description\":\"Question: If we blend with 2 types of materials such as limestone and clay, what parameter is used to control in pile? Here's the answer...\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/12\\\/cementworker.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/wp-content\\\/uploads\\\/sites\\\/3\\\/2016\\\/12\\\/cementworker.jpg\",\"width\":2028,\"height\":946,\"caption\":\"cement production worker\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/mining\\\/question-about-limestone-and-clay-blending-in-cement-production\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Question About Limestone and Clay Blending in Cement Production\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/\",\"name\":\"Advancing Mining\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/mining\\\/#\\\/schema\\\/person\\\/084f4ad87b938d6a238a48082bf2475f\",\"name\":\"Darrell Leetham\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g\",\"caption\":\"Darrell Leetham\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/darrell-leethamthermofisher-com\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Question About Limestone and Clay Blending for Cement Production","description":"Question: If we blend with 2 types of materials such as limestone and clay, what parameter is used to control in pile? Here's the answer...","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/","og_locale":"en_US","og_type":"article","og_title":"Question About Limestone and Clay Blending in Cement Production","og_description":"Question: If we blend with 2 types of materials such as limestone and clay, what parameter is used to control in pile? Here's the answer...","og_url":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/","og_site_name":"Advancing Mining","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-12-06T13:01:03+00:00","article_modified_time":"2026-01-06T20:50:10+00:00","og_image":[{"width":2028,"height":946,"url":"http:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg","type":"image\/jpeg"}],"author":"Darrell Leetham","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Darrell Leetham","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/"},"author":{"name":"Darrell Leetham","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/084f4ad87b938d6a238a48082bf2475f"},"headline":"Question About Limestone and Clay Blending in Cement Production","datePublished":"2016-12-06T13:01:03+00:00","dateModified":"2026-01-06T20:50:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/"},"wordCount":627,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/","url":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/","name":"Question About Limestone and Clay Blending for Cement Production","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg","datePublished":"2016-12-06T13:01:03+00:00","dateModified":"2026-01-06T20:50:10+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/084f4ad87b938d6a238a48082bf2475f"},"description":"Question: If we blend with 2 types of materials such as limestone and clay, what parameter is used to control in pile? Here's the answer...","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg","width":2028,"height":946,"caption":"cement production worker"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/mining\/question-about-limestone-and-clay-blending-in-cement-production\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/mining\/"},{"@type":"ListItem","position":2,"name":"Question About Limestone and Clay Blending in Cement Production"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#website","url":"https:\/\/admin.acceleratingscience.com\/mining\/","name":"Advancing Mining","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/mining\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/mining\/#\/schema\/person\/084f4ad87b938d6a238a48082bf2475f","name":"Darrell Leetham","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/1eee654c9224c5e6e97936d15625cfd1e0ce21cc46addf11e93876b77c284d0e?s=96&d=mm&r=g","caption":"Darrell Leetham"},"url":"https:\/\/admin.acceleratingscience.com\/author\/darrell-leethamthermofisher-com\/"}]}},"taxonomy_info":{"category":[{"value":225,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker-1024x478.jpg",760,355,true],"author_info":{"display_name":"Darrell Leetham","author_link":"https:\/\/admin.acceleratingscience.com\/author\/darrell-leethamthermofisher-com\/"},"comment_info":0,"category_info":[{"term_id":225,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":225,"taxonomy":"category","description":"","parent":0,"count":158,"filter":"raw","meta":[],"cat_ID":225,"category_count":158,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":13544,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/did-you-read-these-mining-and-minerals-articles-yet\/","url_meta":{"origin":9975,"position":0},"title":"Did You Read These Mining and Minerals Articles Yet?","author":"Marlene Gasdia-Cochrane","date":"December 16, 2025","format":false,"excerpt":"According to Google, here are the Top 10 read articles this year from Advancing Mining. Some have been around for quite awhile, but are still as relevant as ever. If you missed any of the latest articles, just click\u00a0here\u00a0to see the most recently published articles. You can even filter by\u2026","rel":"","context":"In &quot;General\/Industry&quot;","block_context":{"text":"General\/Industry","link":"https:\/\/admin.acceleratingscience.com\/mining\/general-industry-mining\/"},"img":{"alt_text":"Top 10, words, isolated on a dark blue background. Alphabet on stone blocks.Rating. Rating concept. Background.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/12\/iStock-1411361298.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1624,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/a-halloween-treat-free-periodic-table\/","url_meta":{"origin":9975,"position":1},"title":"A Halloween Treat &#8211; Free Periodic Table","author":"Marlene Gasdia-Cochrane","date":"October 30, 2025","format":false,"excerpt":"No tricks here. Download this handy periodic table and X-ray energy reference guide to help in analyzing your mining samples. \u00a0It's our treat. Then visit our Mining and Minerals, Cement Production, and Coal Power pages for more goodies. Download Periodic Table.\u00a0 \u00a0","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"halloween scene with plastic pumpkin and candy","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/No-Tricks-.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":13488,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/the-role-of-edxrf-spectrometers-in-the-extraction-of-copper-from-ore\/","url_meta":{"origin":9975,"position":2},"title":"The Role of EDXRF Spectrometers in the Extraction of Copper from Ore","author":"Marlene Gasdia-Cochrane","date":"November 4, 2025","format":false,"excerpt":"Copper extraction is a complex process requiring precise control to ensure high purity. Energy Dispersive X-ray Fluorescence (EDXRF) spectrometers play a vital role by providing fast, non-destructive elemental analysis of ores, concentrates, and intermediate products. This enables mining operations to optimize extraction efficiency, maintain quality assurance, and meet stringent industry\u2026","rel":"","context":"In &quot;Elemental\/Geochemical Analysis&quot;","block_context":{"text":"Elemental\/Geochemical Analysis","link":"https:\/\/admin.acceleratingscience.com\/mining\/elemental-geochemical-analysis\/"},"img":{"alt_text":"a rock showing signs of copper and gold.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2025\/10\/iStock-1309478061.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14155,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/how-process-mass-spectrometry-based-on-line-gas-analysis-supports-compressed-biogas-quality-and-process-monitoring\/","url_meta":{"origin":9975,"position":3},"title":"How Process Mass Spectrometry-based On-line Gas Analysis Supports Compressed Biogas Quality and Process Monitoring","author":"Marlene Gasdia-Cochrane","date":"October 6, 2026","format":false,"excerpt":"Article Summary Compressed biogas (CBG) production requires continuous monitoring of gas composition from raw biogas through upgrading to final biomethane quality. Online gas analysis using process mass spectrometry provides real-time, multicomponent measurements that can help operators monitor methane, carbon dioxide, moisture, sulfur compounds and methane slip while improving visibility into\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Biogas production, biogas plant, bio power","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/10\/iStock-2167149558_biogas.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":2707,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/potash-a-look-at-the-worlds-most-popular-fertilizer\/","url_meta":{"origin":9975,"position":4},"title":"Potash: A Look at the World\u2019s Most Popular Fertilizer","author":"Ali Somarin","date":"April 8, 2026","format":false,"excerpt":"Potash Explained Potash is one of the most essential fertilizers in modern agriculture, supplying potassium\u2014an irreplaceable nutrient that supports plant growth, crop yield, and overall food production. According to the U.S. Geological Survey (USGS), about 85% of potash is used in fertilizers, underscoring its critical role in global farming systems.\u2026","rel":"","context":"In &quot;Data Management\/Lab Automation&quot;","block_context":{"text":"Data Management\/Lab Automation","link":"https:\/\/admin.acceleratingscience.com\/mining\/data-management-lab-automation\/"},"img":{"alt_text":"potash evaporation ponds at mining site","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2014\/06\/iStock-1362567340.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":14089,"url":"https:\/\/www.thermofisher.com\/blog\/mining\/why-real-time-monitoring-is-transforming-refined-fuel-quality-control\/","url_meta":{"origin":9975,"position":5},"title":"Why Real-Time Monitoring Is Transforming Refined Fuel Quality Control","author":"Marlene Gasdia-Cochrane","date":"July 21, 2026","format":false,"excerpt":"Article Summary Refinery operations depend on precise control of fuel properties. Whether producing gasoline, diesel, jet fuel, or base oils, even small variations can impact product performance, regulatory compliance, and profitability. Traditionally, fuel quality has been verified through a combination of laboratory testing and online analyzers. While these methods are\u2026","rel":"","context":"In &quot;Oil and Gas&quot;","block_context":{"text":"Oil and Gas","link":"https:\/\/admin.acceleratingscience.com\/mining\/oil-and-gas\/"},"img":{"alt_text":"Aerial view of oil refinery and storage tanks at dusk and night, showcasing energy industry infrastructure, petroleum processing, and industrial landscape.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2026\/07\/iStock-2274125977-scaled.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/mining\/wp-content\/uploads\/sites\/3\/2016\/12\/cementworker.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/9975","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/comments?post=9975"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/posts\/9975\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media\/10027"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/media?parent=9975"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/categories?post=9975"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/tags?post=9975"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/mining\/wp-json\/wp\/v2\/division?post=9975"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}