{"id":3239,"date":"2014-10-17T07:00:42","date_gmt":"2014-10-17T11:00:42","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=3239"},"modified":"2016-04-29T16:52:01","modified_gmt":"2016-04-29T16:52:01","slug":"new-microarray-assay-for-ebola-diagnosis","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/","title":{"rendered":"New Microarray Assay for Ebola Diagnosis"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" style=\"float: left;margin: 10px\" src=\"http:\/\/admin.acceleratingscience.com\/wp-content\/uploads\/2014\/10\/ebola_-_more_than_one.jpg\" alt=\"Ebola Vireons\" width=\"330\" height=\"220\" \/>Filovirus hemorrhagic fever features\u00a0a rapid onset, high level of infectiousness, and staggering mortality rates of up to 90%.\u00a0Because\u00a0no clinically licensed therapeutic treatments or vaccines exist at this point in time, filovirus outbreaks\u2014including the\u00a0Ebola and Marburg viruses\u2014are a significant concern for both public\u00a0health and biodefense. For these reasons, the need for reliable, sensitive diagnostics is acute.<\/p>\n<p>Recently, Kamata et al., working out of the U.S. Army Medical Research Institute for Infectious Diseases, developed a protein microarray-based assay capable of detecting all members of the Filoviridae family: the Marburg virus (<em>Marburg marburgvirus<\/em>) and the Ebola viruses (<em>Sudan ebolavirus, Zaire ebolavirus, Reston ebolavirus, Bundibugyo ebolavirus <\/em>and<em> Ta\u00ef Forest ebolavirus<\/em>).<sup><span style=\"font-size: xx-small\">1<\/span><\/sup><\/p>\n<p>To compose the assay, the research team took full-length genes for nucleoprotein (NP), virion protein 40 (VP40) and the glycoprotein mucin-like domain fragment (GP-mucin) for each virus species and cloned these into a pENTR\/TEV\/D-TOPO vector (Life Technologies, a\u00a0Thermo Fisher Scientific brand). Then they used LR Clonase II (Life Technologies) to shuttle entry vector clones into destination His-tagged expression vectors. The team\u00a0expressed and spotted a total of 34 purified recombinant proteins before microarray processing.<\/p>\n<p>The team used anti-His antibody and a panel of purified filovirus antibodies to validate the assay, confirming that the microarray performed as designed. They determined that all His-tagged proteins were successfully spotted. Most of the antibodies bound with their targets with a high degree of specificity (anti-Marburg-VP40, anti-Marburg-GP, anti-Sudan-VP40, anti-Sudan-GP, anti-Zaire-VP40, anti-Zaire-NP, and anti-Zaire-GP), while some displayed minor cross-reactivity.<\/p>\n<p>The researchers also evaluated the assay using serum samples from rhesus macaques vaccinated with trivalent virus-like particles (VLPs) prior to challenge with <em>Marburg marburgvirus<\/em> (MARV) or <em>Zaire ebolavirus<\/em> (ZEBOV). They collected three samples from each primate: naive, post-immunization, and post-challenge. The team applied the serum samples to their microarray, detecting bound IgG using fluorescently labeled antibodies.<\/p>\n<p>For both MARV and ZEBOV, the scientists\u00a0report a significant increase in antibody response in immunized versus naive samples and an even greater increase in challenged samples. They reported cross-reactivity among Ebola NPs and VP40s, but highly specific GP responses. Secondary evaluation of <em>Escherichia coli<\/em>-expressed GP-mucins indicated similar antibody recognition, as compared to multi-domain GPs from eukaryotic cells, confirming the GP-mucin domain as a reliable serological marker. In addition to detecting IgG responses, they also reported measurement of relative levels of IgM antibodies. The team notes that the significant increase in ZEBOV- and MARV-specific IgG after challenge indicates that VLP vaccination did not confer sterilizing immunity.<\/p>\n<p>Overall, Kamata et al. report their protein microarray assay to be highly sensitive while requiring minimal sample volume (1\u20132 microliters).\u00a0Although the team evaluated only two filovirus strains in this study, they posit that their assay could assist clinicians in multiplexed analysis involving all strains. Furthermore, they indicate that, given the limited resources available in most outbreak settings, a low-cost, point-of-care assay could expedite diagnosis and allow for serological surveillance. Considering the aggressive and virulent nature of filovirus infection, an epidemiological surveillance system\u2014including for\u00a0outbreaks of both human and zoonotic infections\u2014is imperative for adequate epidemic response.<br \/>\n<strong>Reference<\/strong><\/p>\n<p>1. Kamata, T., et al. (2014, September)\u00a0&#8220;<a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/25230936\" target=\"_blank\">Determination of Specific Antibody Responses to the Six Species of Ebola and Marburg Viruses by Multiplexed Protein Microarrays<\/a>,&#8221; Clinical\u00a0and Vaccine Immunology, doi: 10.1128\/CVI.00484-14 [e-pub ahead of print].<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><i>Post Author: Melissa J. Mayer. Melissa is a freelance writer who specializes in science journalism. She possesses passion for and experience in the fields of proteomics, cellular\/molecular biology, microbiology, biochemistry, and immunology. Melissa is also bilingual (Spanish) and holds a teaching certificate with a biology endorsement.<\/i><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Filovirus hemorrhagic fever features\u00a0a rapid onset, high level of infectiousness, and staggering mortality rates of up to 90%.\u00a0Because\u00a0no clinically licensed therapeutic treatments or vaccines exist at this point in time, filovirus outbreaks\u2014including the\u00a0Ebola and Marburg viruses\u2014are a significant concern for both public\u00a0health and biodefense. For these reasons, the need for reliable, sensitive diagnostics is acute.<\/p>\n","protected":false},"author":16,"featured_media":3238,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[17],"tags":[14,58,67],"division":[],"class_list":["post-3239","post","type-post","status-publish","format-standard","has-post-thumbnail","category-virology","tag-ebola","tag-ebola-virus","tag-ebov","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Ebola: Diagnostic Filovirus Microarray Assay<\/title>\n<meta name=\"description\" content=\"Diagnostic filovirus microarray-based assay for ebola and marburg, suitable for multiplexed diagnosis and serological surveillance.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"New Microarray Assay for Ebola Diagnosis\" \/>\n<meta property=\"og:description\" content=\"Diagnostic filovirus microarray-based assay for ebola and marburg, suitable for multiplexed diagnosis and serological surveillance.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/\" \/>\n<meta property=\"og:site_name\" content=\"Accelerating Proteomics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2014-10-17T11:00:42+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-04-29T16:52:01+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"334\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Melissa J. Mayer\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Melissa J. Mayer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/\"},\"author\":{\"name\":\"Melissa J. Mayer\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/98b44a934f33109965e66778575442de\"},\"headline\":\"New Microarray Assay for Ebola Diagnosis\",\"datePublished\":\"2014-10-17T11:00:42+00:00\",\"dateModified\":\"2016-04-29T16:52:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/\"},\"wordCount\":597,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2014\\\/10\\\/ebola_-_more_than_one.jpg\",\"keywords\":[\"ebola\",\"Ebola Virus\",\"EBOV\"],\"articleSection\":[\"Virology\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/\",\"name\":\"Ebola: Diagnostic Filovirus Microarray Assay\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2014\\\/10\\\/ebola_-_more_than_one.jpg\",\"datePublished\":\"2014-10-17T11:00:42+00:00\",\"dateModified\":\"2016-04-29T16:52:01+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/98b44a934f33109965e66778575442de\"},\"description\":\"Diagnostic filovirus microarray-based assay for ebola and marburg, suitable for multiplexed diagnosis and serological surveillance.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2014\\\/10\\\/ebola_-_more_than_one.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2014\\\/10\\\/ebola_-_more_than_one.jpg\",\"width\":500,\"height\":334,\"caption\":\"Ebola Vireons\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/new-microarray-assay-for-ebola-diagnosis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"New Microarray Assay for Ebola Diagnosis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/\",\"name\":\"Accelerating Proteomics\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/98b44a934f33109965e66778575442de\",\"name\":\"Melissa J. Mayer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g\",\"caption\":\"Melissa J. Mayer\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/melissaj-mayer\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ebola: Diagnostic Filovirus Microarray Assay","description":"Diagnostic filovirus microarray-based assay for ebola and marburg, suitable for multiplexed diagnosis and serological surveillance.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/","og_locale":"en_US","og_type":"article","og_title":"New Microarray Assay for Ebola Diagnosis","og_description":"Diagnostic filovirus microarray-based assay for ebola and marburg, suitable for multiplexed diagnosis and serological surveillance.","og_url":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/","og_site_name":"Accelerating Proteomics","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2014-10-17T11:00:42+00:00","article_modified_time":"2016-04-29T16:52:01+00:00","og_image":[{"width":500,"height":334,"url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg","type":"image\/jpeg"}],"author":"Melissa J. Mayer","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Melissa J. Mayer","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/"},"author":{"name":"Melissa J. Mayer","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/98b44a934f33109965e66778575442de"},"headline":"New Microarray Assay for Ebola Diagnosis","datePublished":"2014-10-17T11:00:42+00:00","dateModified":"2016-04-29T16:52:01+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/"},"wordCount":597,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg","keywords":["ebola","Ebola Virus","EBOV"],"articleSection":["Virology"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/","url":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/","name":"Ebola: Diagnostic Filovirus Microarray Assay","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg","datePublished":"2014-10-17T11:00:42+00:00","dateModified":"2016-04-29T16:52:01+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/98b44a934f33109965e66778575442de"},"description":"Diagnostic filovirus microarray-based assay for ebola and marburg, suitable for multiplexed diagnosis and serological surveillance.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg","width":500,"height":334,"caption":"Ebola Vireons"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/new-microarray-assay-for-ebola-diagnosis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/proteomics\/"},{"@type":"ListItem","position":2,"name":"New Microarray Assay for Ebola Diagnosis"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#website","url":"https:\/\/admin.acceleratingscience.com\/proteomics\/","name":"Accelerating Proteomics","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/proteomics\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/98b44a934f33109965e66778575442de","name":"Melissa J. Mayer","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g","caption":"Melissa J. Mayer"},"url":"https:\/\/admin.acceleratingscience.com\/author\/melissaj-mayer\/"}]}},"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2014\/10\/ebola_-_more_than_one.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts\/3239","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/comments?post=3239"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts\/3239\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/media\/3238"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/media?parent=3239"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/categories?post=3239"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/tags?post=3239"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/division?post=3239"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}