{"id":8194,"date":"2016-04-04T07:00:52","date_gmt":"2016-04-04T11:00:52","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/?p=8194"},"modified":"2016-08-09T21:27:18","modified_gmt":"2016-08-09T21:27:18","slug":"benchmarking-proteomics-a-dynamic-range-metric","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/","title":{"rendered":"Benchmarking Proteomics: A Dynamic Range Metric"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" style=\"float: left;margin: 10px\" src=\"http:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg\" alt=\"Abstract image of protein. Image: molekuul_be\/Shutterstock.com\" width=\"330\" height=\"330\" \/>Benchmarking instrument performance in a way that transfers across scientific laboratories is a current focus for liquid chromatography\u2013mass spectrometry (LC-MS)-based research. One measure\u00a0unavailable from current metrics is dynamic range. This essential parameter requires research teams to meticulously create an external calibration curve by spiking complex samples with exogenous compounds at decreasing concentrations.<\/p>\n<p>Beri et al. (2015) indicate that a single standard\u00a0to assess dynamic range as well as other critical metrics would ease this burden and allow laboratories to run routine performance-tracking and system evaluation. Toward this end, they developed a single-injection proteomic standard capable of assessing inter-run peptide identification metrics as well as within-run dynamic range.<sup>1<\/sup><\/p>\n<p>The team\u2019s 6 x 5 LC-MS\/MS peptide reference mixture combines six peptides plus five labeled isotopologues each for 30 total peptides. To construct this mixure, the team used a library of human serum peptides between 7 and 15 amino acids in length, selecting against peptides that demonstrated instability (oxidation, isomerization, deamidation) or that they believed to pose synthesis or solubilization challenges. They selected the six peptide sequences (VTSGSTSTSR, LASVSVSR, YVYVADVAAK, VVGGLVALR, LLSLGAGEFK and LGFTDLFSK) plus stable isotope\u2013labeled isotopologues and combined these at different concentrations spanning four orders of magnitude.<\/p>\n<p>The team spiked this mixture into complex kidney cell lysate digest for separation using a reverse phase column and applied a <a href=\"http:\/\/www.thermoscientific.com\/en\/product\/q-exactive-plus-hybrid-quadrupole-orbitrap-mass-spectrometer.html\" target=\"_blank\">Q Exactive Plus mass spectrometer<\/a> (Thermo Scientific) for detection. The researchers indicate that they selected peptides that elute across the gradient with a wide range of hydrophobicities (grand average hydropathy, or GRAVY, scores -0.7 to 1.9). On column, the isotopologues ranged from 500 fmol to 0.05 fmol within 0.25 \u03bcg of lysate.<\/p>\n<p>When calculating linear dynamic range, the team generated peaks for each of the 30 reference peptides and, using the average peak area from three injections for each reference peptide, plotted log<sub>10<\/sub> peak area against log<sub>10<\/sub> concentration. They report that the least abundant isotopologue for each peptide was frequently undetectable or outside the linear range, indicating an intra-scan linear dynamic range of at least three orders of dynamic range but less than four. Using variance analysis, the team found no systematic trend for mass measurement accuracy\u00a0as a function of abundance.<\/p>\n<p>To evaluate the stability of the peptide reference mixture, the team conducted 44 injections over one week. They found five of the six peptides were stable, with coefficients of variation ranging from 12.09% to 17.27%. After the 40th injection, the most hydrophilic peptide (peptide I) became undetectable. However, when the team applied a fresh column to the LC system, the signal for this peptide returned, confirming this peptide as a sensitive indicator of reverse phase column performance specific to hydrophilic peptides.<\/p>\n<p>The researchers also obtained peak areas for all isotopologues of peptide IV and used<span class=\"thread\"> these<\/span>\u00a0values to determine precision of quantitation across time. Combining three measures (visualization in log space, CV and percent error), they report three orders of linear dynamic range and a 500 amol limit of quantitation.<\/p>\n<p>Finally, the team assessed performance differences between MS1 quantitation and targeted MS2 (parallel reaction monitoring, PRM). They report that the fifth isotopologue was undetectable using MS1 but could be detected above the noise threshold via PRM scans. Targeted MS\/MS also showed a more linear dynamic range across four orders of magnitude for peptides II, IV and V when compared with MS1.<\/p>\n<p>Overall, Beri et al. offer this proteomic standard as a tool for intra-instrument performance monitoring and inter-instrument comparison. Additional applications include technology development like assessing novel sample preparation protocols and LC-MS techniques.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Reference<\/strong><\/p>\n<p>1. Beri, J., et al. (2015) &#8220;<a href=\"http:\/\/www.ncbi.nlm.nih.gov\/pubmed\/26537636\" target=\"_blank\">Reagent for evaluating liquid chromatography\u2212tandem mass spectrometry (LC-MS\/MS) performance in bottom-up proteomic experiments<\/a>,&#8221;\u00a0Analytical Chemistry 87(23) (pp. 11635\u221211640). doi: 10.1021\/acs.analchem.5b04121<\/p>\n<p><i>Post Author: Melissa J. Mayer. Melissa is a freelance writer who specializes in science journalism. She possesses passion for and experience in the fields of proteomics, cellular\/molecular biology, microbiology, biochemistry, and immunology. Melissa is also bilingual (Spanish) and holds a teaching certificate with a biology endorsement.<\/i><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Benchmarking instrument performance in a way that transfers across scientific laboratories is a current focus for liquid chromatography\u2013mass spectrometry (LC-MS)-based research. One measure\u00a0unavailable from current metrics is dynamic range. This essential parameter requires research teams to meticulously create an external calibration curve by spiking complex samples with exogenous compounds at decreasing concentrations. Beri et al.<\/p>\n","protected":false},"author":16,"featured_media":8193,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[12],"tags":[890,258],"division":[],"class_list":["post-8194","post","type-post","status-publish","format-standard","has-post-thumbnail","category-methods","tag-featured","tag-instrument-evaluation","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Benchmarking Proteomics: A Dynamic Range Metric<\/title>\n<meta name=\"description\" content=\"A recent paper outlines development of a proteomic reference standard as a tool to measure dynamic range and other metrics for instrument performance and comparison.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Benchmarking Proteomics: A Dynamic Range Metric\" \/>\n<meta property=\"og:description\" content=\"A recent paper outlines development of a proteomic reference standard as a tool to measure dynamic range and other metrics for instrument performance and comparison.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/\" \/>\n<meta property=\"og:site_name\" content=\"Accelerating Proteomics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-04-04T11:00:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-08-09T21:27:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"500\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Melissa J. Mayer\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Melissa J. Mayer\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/\"},\"author\":{\"name\":\"Melissa J. Mayer\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/98b44a934f33109965e66778575442de\"},\"headline\":\"Benchmarking Proteomics: A Dynamic Range Metric\",\"datePublished\":\"2016-04-04T11:00:52+00:00\",\"dateModified\":\"2016-08-09T21:27:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/\"},\"wordCount\":655,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/shutterstock_274455926.jpg\",\"keywords\":[\"featured\",\"instrument evaluation\"],\"articleSection\":[\"Methods\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/\",\"name\":\"Benchmarking Proteomics: A Dynamic Range Metric\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/shutterstock_274455926.jpg\",\"datePublished\":\"2016-04-04T11:00:52+00:00\",\"dateModified\":\"2016-08-09T21:27:18+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/98b44a934f33109965e66778575442de\"},\"description\":\"A recent paper outlines development of a proteomic reference standard as a tool to measure dynamic range and other metrics for instrument performance and comparison.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/shutterstock_274455926.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/04\\\/shutterstock_274455926.jpg\",\"width\":500,\"height\":500,\"caption\":\"Abstract image of protein. Image: molekuul_be\\\/Shutterstock.com\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/benchmarking-proteomics-a-dynamic-range-metric\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Benchmarking Proteomics: A Dynamic Range Metric\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/\",\"name\":\"Accelerating Proteomics\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/98b44a934f33109965e66778575442de\",\"name\":\"Melissa J. Mayer\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g\",\"caption\":\"Melissa J. Mayer\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/melissaj-mayer\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Benchmarking Proteomics: A Dynamic Range Metric","description":"A recent paper outlines development of a proteomic reference standard as a tool to measure dynamic range and other metrics for instrument performance and comparison.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/","og_locale":"en_US","og_type":"article","og_title":"Benchmarking Proteomics: A Dynamic Range Metric","og_description":"A recent paper outlines development of a proteomic reference standard as a tool to measure dynamic range and other metrics for instrument performance and comparison.","og_url":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/","og_site_name":"Accelerating Proteomics","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-04-04T11:00:52+00:00","article_modified_time":"2016-08-09T21:27:18+00:00","og_image":[{"width":500,"height":500,"url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg","type":"image\/jpeg"}],"author":"Melissa J. Mayer","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Melissa J. Mayer","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/"},"author":{"name":"Melissa J. Mayer","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/98b44a934f33109965e66778575442de"},"headline":"Benchmarking Proteomics: A Dynamic Range Metric","datePublished":"2016-04-04T11:00:52+00:00","dateModified":"2016-08-09T21:27:18+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/"},"wordCount":655,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg","keywords":["featured","instrument evaluation"],"articleSection":["Methods"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/","url":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/","name":"Benchmarking Proteomics: A Dynamic Range Metric","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg","datePublished":"2016-04-04T11:00:52+00:00","dateModified":"2016-08-09T21:27:18+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/98b44a934f33109965e66778575442de"},"description":"A recent paper outlines development of a proteomic reference standard as a tool to measure dynamic range and other metrics for instrument performance and comparison.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg","width":500,"height":500,"caption":"Abstract image of protein. Image: molekuul_be\/Shutterstock.com"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/benchmarking-proteomics-a-dynamic-range-metric\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/proteomics\/"},{"@type":"ListItem","position":2,"name":"Benchmarking Proteomics: A Dynamic Range Metric"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#website","url":"https:\/\/admin.acceleratingscience.com\/proteomics\/","name":"Accelerating Proteomics","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/proteomics\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/98b44a934f33109965e66778575442de","name":"Melissa J. Mayer","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6b805ef3b273db73b1406b8cd48731f1f3160c02c0ff9b3ca848301947b14dc3?s=96&d=mm&r=g","caption":"Melissa J. Mayer"},"url":"https:\/\/admin.acceleratingscience.com\/author\/melissaj-mayer\/"}]}},"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/04\/shutterstock_274455926.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts\/8194","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/comments?post=8194"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts\/8194\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/media\/8193"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/media?parent=8194"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/categories?post=8194"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/tags?post=8194"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/division?post=8194"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}