{"id":8670,"date":"2016-06-16T11:00:03","date_gmt":"2016-06-16T11:00:03","guid":{"rendered":"http:\/\/admin.acceleratingscience.com\/proteomics\/?p=8670"},"modified":"2016-06-29T13:15:29","modified_gmt":"2016-06-29T13:15:29","slug":"combining-the-power-of-mass-spectrometry-and-protein-crystallography","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/","title":{"rendered":"Combining the Power of Mass Spectrometry and Protein Crystallography"},"content":{"rendered":"<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft\" style=\"float: left;\" src=\"http:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg\" alt=\"Monoclonal antibody. Image: molekuul_be\/Shutterstock.com\" width=\"330\" height=\"274\" \/>Monoclonal antibody (mAb) therapies are growing exponentially, but they often get held up at the approval stage due to a lack of sequence information.<\/p>\n<p><span class=\"thread\">Using mass spectrometry (MS) in combination with protein crystallograph<\/span>y, Bogdanoff et al.\u00a0show how it is possible to determine the amino acid sequence, the glycosylation pattern and the structure of the antigen-binding fragment (Fab) of an mAb.<sup>1<\/sup> This information can then be used to engineer a recombinant antibody single-chain variable fragment (scFv) that has the same specificity as the parent mAb.<\/p>\n<p>Bogdanoff et al. looked at an mAb that is capable of neutralizing human astrovirus (HAstV), which is a leading cause of diarrhea in children and immunocompromised individuals. No vaccines or antiretrovirals currently exist for HAstV infections, but evidence suggests that antibodies produced by the adaptive immune response could be capable of being used as therapeutics to fight off the infection.<\/p>\n<p>The team looked at mAb PL-2, which has previously been shown able to neutralize the HAstV serotype 2 (HAstV-2). The amino acid sequence of this antibody was initially unknown.<\/p>\n<p>Unfortunately, the hybridoma cells that originally produced mAb PL-2 were no longer available. Using limited quantities of the antibody purified by Protein A affinity chromatography<span class=\"thread\"> from mouse ascites<\/span>, Bogdanoff et al. were able to crystallize and perform de novo sequencing by MS of the antigen-binding fragment of the mAb.<\/p>\n<p>From\u00a0the structural and sequence information, the team was able to \u201cresurrect\u201d the antibody by engineering a recombinant scFV that they found binds specifically to the HAstV-2 capsid protein.<\/p>\n<p>The scientists <span class=\"thread\">obtained\u00a0<\/span>the majority of the amino acid sequence (approximately 90%) directly from the crystallographic structure, due to <span class=\"thread\">it<\/span> being of such high resolution (1.9 \u200e\u00c5). To obtain complete sequencing, the team then turned to de novo protein sequencing by MS.<\/p>\n<p>The scientists used four different protease digestions and performed high-resolution tandem MS on 0.1 \u03bcg of the intact and 0.1 \u03bcg of the reduced Fab PL-2. It was loaded onto a ProSwift RP-4H monolithic column mounted on an <a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/LC120?ICID=search-product\" target=\"_blank\">EASY nLC-1000<\/a> nano ultra-high-performance liquid chromatograph coupled to a Thermo Scientific\u00a0<a href=\"https:\/\/www.thermofisher.com\/order\/catalog\/product\/IQLAAEGAAPFADBMBHQ?ICID=search-product\" target=\"_blank\">Orbitrap Fusion mass spectrometer.<\/a>The proteomics search software Byonics was used for amino acid sequence determination. During this process some mass differences were noted, later found to be due to an unexpected N-linked glycosylation site on the heavy chain.<\/p>\n<p>Using the combined MS and crystallography information, the team was able to deduce the remaining 10% of the amino acid sequence and determine the full Fab PL-2 sequence with no uncertainties.<\/p>\n<p>Having the unambiguous Fab PL-2 heavy and light chain sequences allowed Bogdanoff et al. to engineer a recombinant antibody construct comprising a scFV of the PL-2 antibody, which was found to bind to the HAstV-2 capsid protein. The scVF construct is a fusion protein of the variable regions of the heavy and light chains, connected by a flexible 20 amino acid linker region.<\/p>\n<p>The team hopes that its research will encourage other infectious disease researchers to embrace de novo protein sequencing in combination with crystallography. Advancements in de novo protein sequencing and recombinant antibody engineering means many more clinically useful mAbs can now be developed.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Reference<\/strong><\/p>\n<p>1. Bogdanoff, W.A., et al. (2016) \u201c<a href=\"http:\/\/pubs.acs.org\/doi\/abs\/10.1021\/acsinfecdis.6b00026\" target=\"_blank\">De novo sequencing and resurrection of a human astrovirus-neutralizing antibody<\/a>,\u201d ACS Infectious Diseases, 2(5) (pp. 313\u2013321). doi: 10.1021\/acsinfecdis.6b00026.<\/p>\n<p><i>Post Author: Kathryn Loydall. Kathryn is a science and medical writer with a background in protein chemistry, biochemistry and applied biology. She enjoys making science accessible to a lay audience through writing, illustrations and media. Originally from the UK, she moved to Vancouver Island in 2008 to complete her PhD focussed on sepsis research and x-ray crystallography of monoclonal antibodies. In 2012, Kathryn left the lab behind to start freelancing as a science and medical writer and editor, and hasn&#8217;t looked back since. <\/i><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Monoclonal antibody (mAb) therapies are growing exponentially, but they often get held up at the approval stage due to a lack of sequence information. Using mass spectrometry (MS) in combination with protein crystallography, Bogdanoff et al.\u00a0show how it is possible to determine the amino acid sequence, the glycosylation pattern and the structure of the antigen-binding<\/p>\n","protected":false},"author":244,"featured_media":8669,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_memberships_contains_paid_content":false,"footnotes":""},"categories":[12],"tags":[266],"division":[],"class_list":{"0":"post-8670","1":"post","2":"type-post","3":"status-publish","4":"format-standard","5":"has-post-thumbnail","7":"category-methods","8":"tag-monoclonal-antibodies","9":"entry"},"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Combining the Power of Mass Spectrometry and Protein Crystallography<\/title>\n<meta name=\"description\" content=\"Scientists use mass spectrometry and protein crystallography to determine the amino acid sequence, glycosylation pattern, and structure of monoclonal antibodies.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Combining the Power of Mass Spectrometry and Protein Crystallography\" \/>\n<meta property=\"og:description\" content=\"Scientists use mass spectrometry and protein crystallography to determine the amino acid sequence, glycosylation pattern, and structure of monoclonal antibodies.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/\" \/>\n<meta property=\"og:site_name\" content=\"Accelerating Proteomics\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2016-06-16T11:00:03+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2016-06-29T13:15:29+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"500\" \/>\n\t<meta property=\"og:image:height\" content=\"415\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Kathryn Loydall\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Kathryn Loydall\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/\"},\"author\":{\"name\":\"Kathryn Loydall\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/e85a3fa5ab0bae77354306f2f8e06475\"},\"headline\":\"Combining the Power of Mass Spectrometry and Protein Crystallography\",\"datePublished\":\"2016-06-16T11:00:03+00:00\",\"dateModified\":\"2016-06-29T13:15:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/\"},\"wordCount\":626,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/06\\\/shutterstock_155132699.jpg\",\"keywords\":[\"monoclonal antibodies\"],\"articleSection\":[\"Methods\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/\",\"name\":\"Combining the Power of Mass Spectrometry and Protein Crystallography\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/06\\\/shutterstock_155132699.jpg\",\"datePublished\":\"2016-06-16T11:00:03+00:00\",\"dateModified\":\"2016-06-29T13:15:29+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/e85a3fa5ab0bae77354306f2f8e06475\"},\"description\":\"Scientists use mass spectrometry and protein crystallography to determine the amino acid sequence, glycosylation pattern, and structure of monoclonal antibodies.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/06\\\/shutterstock_155132699.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/wp-content\\\/uploads\\\/sites\\\/2\\\/2016\\\/06\\\/shutterstock_155132699.jpg\",\"width\":500,\"height\":415,\"caption\":\"Monoclonal antibody. Image: molekuul_be\\\/Shutterstock.com\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/proteomics\\\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Combining the Power of Mass Spectrometry and Protein Crystallography\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/\",\"name\":\"Accelerating Proteomics\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/proteomics\\\/#\\\/schema\\\/person\\\/e85a3fa5ab0bae77354306f2f8e06475\",\"name\":\"Kathryn Loydall\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b56f51f22d343784c12e747fb98e48e0b720f229eee6e556b326b85abcddc2b2?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b56f51f22d343784c12e747fb98e48e0b720f229eee6e556b326b85abcddc2b2?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/b56f51f22d343784c12e747fb98e48e0b720f229eee6e556b326b85abcddc2b2?s=96&d=mm&r=g\",\"caption\":\"Kathryn Loydall\"},\"description\":\"Kathryn is a science and medical writer with a background in protein chemistry, biochemistry and applied biology. She enjoys making science accessible to a lay audience through writing, illustrations and media. Originally from the UK, she moved to Vancouver Island in 2008 to complete her PhD focussed on sepsis research and x-ray crystallography of monoclonal antibodies. In 2012, Kathryn left the lab behind to start freelancing as a science and medical writer and editor, and hasn't looked back since.\",\"sameAs\":[\"https:\\\/\\\/app.kapost.com\\\/profile\\\/kathryn-loydall\"],\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/kathrynloydall\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Combining the Power of Mass Spectrometry and Protein Crystallography","description":"Scientists use mass spectrometry and protein crystallography to determine the amino acid sequence, glycosylation pattern, and structure of monoclonal antibodies.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/","og_locale":"en_US","og_type":"article","og_title":"Combining the Power of Mass Spectrometry and Protein Crystallography","og_description":"Scientists use mass spectrometry and protein crystallography to determine the amino acid sequence, glycosylation pattern, and structure of monoclonal antibodies.","og_url":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/","og_site_name":"Accelerating Proteomics","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2016-06-16T11:00:03+00:00","article_modified_time":"2016-06-29T13:15:29+00:00","og_image":[{"width":500,"height":415,"url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg","type":"image\/jpeg"}],"author":"Kathryn Loydall","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Kathryn Loydall","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/"},"author":{"name":"Kathryn Loydall","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/e85a3fa5ab0bae77354306f2f8e06475"},"headline":"Combining the Power of Mass Spectrometry and Protein Crystallography","datePublished":"2016-06-16T11:00:03+00:00","dateModified":"2016-06-29T13:15:29+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/"},"wordCount":626,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg","keywords":["monoclonal antibodies"],"articleSection":["Methods"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/","url":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/","name":"Combining the Power of Mass Spectrometry and Protein Crystallography","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg","datePublished":"2016-06-16T11:00:03+00:00","dateModified":"2016-06-29T13:15:29+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/e85a3fa5ab0bae77354306f2f8e06475"},"description":"Scientists use mass spectrometry and protein crystallography to determine the amino acid sequence, glycosylation pattern, and structure of monoclonal antibodies.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg","width":500,"height":415,"caption":"Monoclonal antibody. Image: molekuul_be\/Shutterstock.com"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/proteomics\/combining-the-power-of-mass-spectrometry-and-protein-crystallography\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/proteomics\/"},{"@type":"ListItem","position":2,"name":"Combining the Power of Mass Spectrometry and Protein Crystallography"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#website","url":"https:\/\/admin.acceleratingscience.com\/proteomics\/","name":"Accelerating Proteomics","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/proteomics\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/proteomics\/#\/schema\/person\/e85a3fa5ab0bae77354306f2f8e06475","name":"Kathryn Loydall","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/b56f51f22d343784c12e747fb98e48e0b720f229eee6e556b326b85abcddc2b2?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/b56f51f22d343784c12e747fb98e48e0b720f229eee6e556b326b85abcddc2b2?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/b56f51f22d343784c12e747fb98e48e0b720f229eee6e556b326b85abcddc2b2?s=96&d=mm&r=g","caption":"Kathryn Loydall"},"description":"Kathryn is a science and medical writer with a background in protein chemistry, biochemistry and applied biology. She enjoys making science accessible to a lay audience through writing, illustrations and media. Originally from the UK, she moved to Vancouver Island in 2008 to complete her PhD focussed on sepsis research and x-ray crystallography of monoclonal antibodies. In 2012, Kathryn left the lab behind to start freelancing as a science and medical writer and editor, and hasn't looked back since.","sameAs":["https:\/\/app.kapost.com\/profile\/kathryn-loydall"],"url":"https:\/\/admin.acceleratingscience.com\/author\/kathrynloydall\/"}]}},"jetpack-related-posts":[],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/proteomics\/wp-content\/uploads\/sites\/2\/2016\/06\/shutterstock_155132699.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts\/8670","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/users\/244"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/comments?post=8670"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/posts\/8670\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/media\/8669"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/media?parent=8670"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/categories?post=8670"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/tags?post=8670"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/proteomics\/wp-json\/wp\/v2\/division?post=8670"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}