{"id":108,"date":"2020-12-02T16:12:28","date_gmt":"2020-12-02T16:12:28","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/semiconductors\/2020\/12\/02\/looking-to-increase-semiconductor-sample-success-rates\/"},"modified":"2023-07-27T20:59:10","modified_gmt":"2023-07-27T20:59:10","slug":"looking-to-increase-semiconductor-sample-success-rates","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/","title":{"rendered":"Looking to Increase Semiconductor Sample Success Rates?"},"content":{"rendered":"<p>In our <a href=\"https:\/\/www.thermofisher.com\/blog\/microscopy\/semiconductor-failure-analysis-takes-daysit-should-take-hours\/\">previous blog<\/a>, we talked about how failure analysis has become a tedious and time-consuming job. FA engineers work with larger sample volumes and more complex device architectures, making it challenging to obtain precise data from every sample. FA engineers demand, fast, repeatable, high-quality milling and imaging to reduce bottlenecks caused by inefficient failure analysis workflows and increase time-to-data. The right instrument for the job is one that automates key workflows with high quality imaging to collect data from every sample.<\/p>\n<h2 style=\"color: white;font-size: 50%\">Failure analysis of semiconductor samples with the Helios 5 PFIB DualBeam<\/h2>\n<p>Our new Thermo Fisher Scientific <strong>Helios 5 PFIB DualBeam FIB-SEM<\/strong> provides unique, site-specific, delayering and failure analysis workflows for advanced logic, 3D NAND, and 2.5\/3D packaging. It also provides high speed, large area cross-sectioning, high-resolution TEM sample preparation, sub-nanometer low energy SEM performance, and automated deprocessing with end pointing for the shortest time to nanoscale information.<\/p>\n<div style=\"width: 528px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" style=\"vertical-align: middle;margin: 10px\" title=\"High resolution, top down view of deprocessed 3D NAND\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png\" alt=\"High resolution image of 3D NAND\" width=\"518\" height=\"446\" \/><p class=\"wp-caption-text\">High resolution, top down view of deprocessed 3D NAND<\/p><\/div>\n<p>We also understand efficient sample analysis relies on optimum tool alignment to provide the highest performance under any circumstances. The SmartAlign feature included in the Helios 5 PFIB simplifies the process and eliminates the need to micro-monitor SEM alignments for automated delayering, TEM prep and slice and view cross-sectioning<\/p>\n<p>Both automation and high-throughput, high-resolution analysis are crucial for time-strapped FA engineers and lab managers. The advanced capabilities of the Helios 5 PFIB speeds up time-to-data and increases productivity. Our <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/about-us\/events\/industrial\/helios-5-pfib-webinar.html\">webinar<\/a> includes more details on how the Helios 5 PFIB enables higher sample throughput and better automation for semiconductor failure analysis, reducing your time-to-data to <strong>hours instead of days or weeks<\/strong>.<\/p>\n<p><a href=\"https:\/\/ter.li\/rke9vg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-518 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172.jpg\" alt=\"Subscribe to Thermo Fisher Scientific's semiconductor updates and resources\" width=\"1000\" height=\"172\" srcset=\"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172.jpg 1000w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172-768x132.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><\/p>\n<p><em>David Akerson is a Senior Global Market Development Manager for semiconductors at Thermo Fisher Scientific.<\/em><\/p>\n<p>\/\/\/<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In our previous blog, we talked about how failure analysis has become a tedious and time-consuming job. FA engineers work with larger sample volumes and more complex device architectures, making it challenging to obtain precise data from every sample. FA engineers demand, fast, repeatable, high-quality milling and imaging to reduce bottlenecks caused by inefficient failure<\/p>\n","protected":false},"author":1346,"featured_media":110,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[25],"tags":[],"division":[],"class_list":["post-108","post","type-post","status-publish","format-standard","has-post-thumbnail","category-general","entry"],"_selected_authors":"","_selected_reviewers":"","acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Semiconductor Sample - Failure Analysis - Illuminating Semiconductors<\/title>\n<meta name=\"description\" content=\"Semiconductor failure analysis supported by our Helios 5 PFIB DualBeam with fast, repeatable, high-quality milling and imaging to reduce bottlenecks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Looking to Increase Semiconductor Sample Success Rates?\" \/>\n<meta property=\"og:description\" content=\"Semiconductor failure analysis supported by our Helios 5 PFIB DualBeam with fast, repeatable, high-quality milling and imaging to reduce bottlenecks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/\" \/>\n<meta property=\"og:site_name\" content=\"Illuminating Semiconductors\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2020-12-02T16:12:28+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-07-27T20:59:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png\" \/>\n\t<meta property=\"og:image:width\" content=\"518\" \/>\n\t<meta property=\"og:image:height\" content=\"446\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"David Akerson\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"David Akerson\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/\"},\"author\":{\"name\":\"David Akerson\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/7dfc8535eee862bd1f8d905c8b6cb663\"},\"headline\":\"Looking to Increase Semiconductor Sample Success Rates?\",\"datePublished\":\"2020-12-02T16:12:28+00:00\",\"dateModified\":\"2023-07-27T20:59:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/\"},\"wordCount\":291,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/3d20nand20deprocessing.png\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/\",\"name\":\"Semiconductor Sample - Failure Analysis - Illuminating Semiconductors\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/3d20nand20deprocessing.png\",\"datePublished\":\"2020-12-02T16:12:28+00:00\",\"dateModified\":\"2023-07-27T20:59:10+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/7dfc8535eee862bd1f8d905c8b6cb663\"},\"description\":\"Semiconductor failure analysis supported by our Helios 5 PFIB DualBeam with fast, repeatable, high-quality milling and imaging to reduce bottlenecks.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/3d20nand20deprocessing.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/3d20nand20deprocessing.png\",\"width\":518,\"height\":446},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/looking-to-increase-semiconductor-sample-success-rates\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Looking to Increase Semiconductor Sample Success Rates?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\",\"name\":\"Illuminating Semiconductors\",\"description\":\"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/7dfc8535eee862bd1f8d905c8b6cb663\",\"name\":\"David Akerson\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g\",\"caption\":\"David Akerson\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/davidakerson\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Semiconductor Sample - Failure Analysis - Illuminating Semiconductors","description":"Semiconductor failure analysis supported by our Helios 5 PFIB DualBeam with fast, repeatable, high-quality milling and imaging to reduce bottlenecks.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/","og_locale":"en_US","og_type":"article","og_title":"Looking to Increase Semiconductor Sample Success Rates?","og_description":"Semiconductor failure analysis supported by our Helios 5 PFIB DualBeam with fast, repeatable, high-quality milling and imaging to reduce bottlenecks.","og_url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/","og_site_name":"Illuminating Semiconductors","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2020-12-02T16:12:28+00:00","article_modified_time":"2023-07-27T20:59:10+00:00","og_image":[{"width":518,"height":446,"url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png","type":"image\/png"}],"author":"David Akerson","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"David Akerson","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/"},"author":{"name":"David Akerson","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/7dfc8535eee862bd1f8d905c8b6cb663"},"headline":"Looking to Increase Semiconductor Sample Success Rates?","datePublished":"2020-12-02T16:12:28+00:00","dateModified":"2023-07-27T20:59:10+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/"},"wordCount":291,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/","url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/","name":"Semiconductor Sample - Failure Analysis - Illuminating Semiconductors","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png","datePublished":"2020-12-02T16:12:28+00:00","dateModified":"2023-07-27T20:59:10+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/7dfc8535eee862bd1f8d905c8b6cb663"},"description":"Semiconductor failure analysis supported by our Helios 5 PFIB DualBeam with fast, repeatable, high-quality milling and imaging to reduce bottlenecks.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png","width":518,"height":446},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/looking-to-increase-semiconductor-sample-success-rates\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/semiconductors\/"},{"@type":"ListItem","position":2,"name":"Looking to Increase Semiconductor Sample Success Rates?"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/","name":"Illuminating Semiconductors","description":"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/semiconductors\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/7dfc8535eee862bd1f8d905c8b6cb663","name":"David Akerson","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g","caption":"David Akerson"},"url":"https:\/\/admin.acceleratingscience.com\/author\/davidakerson\/"}]}},"taxonomy_info":{"category":[{"value":25,"label":"General"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png",518,446,false],"author_info":{"display_name":"David Akerson","author_link":"https:\/\/admin.acceleratingscience.com\/author\/davidakerson\/"},"comment_info":0,"category_info":[{"term_id":25,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":25,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":25,"category_count":14,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0}],"tag_info":false,"jetpack-related-posts":[{"id":1079,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/supporting-advanced-packaging-with-integrated-semiconductor-failure-analysis-workflows\/","url_meta":{"origin":108,"position":0},"title":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows","author":"Vinay S","date":"October 22, 2026","format":false,"excerpt":"Key takeaways Semiconductor failure analysis of advanced packaging technologies requires the connection of electrical and physical evidence across multiple length scales to identify root cause. Non-destructive methods such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography can be used to localize defects for subsequent targeted investigation. Focused ion\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1047,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/non-destructive-semiconductor-defect-detection-advanced-packaging-technology\/","url_meta":{"origin":108,"position":1},"title":"Non-Destructive Semiconductor Defect Detection\u00a0in\u00a0Advanced Packaging\u00a0Technology","author":"Swarnim Rawat","date":"July 1, 2026","format":false,"excerpt":"Key highlights Compared to conventional package designs, semiconductor defect detection\u00a0is\u00a0more difficult\u00a0for\u00a0advanced packaging\u00a0because failure sites are smaller,\u00a0more deeply embedded, and\u00a0are\u00a0distributed across more material interfaces\u00a0 Non-destructive techniques such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography provide critical information on advanced\u00a0packages\u00a0that can\u00a0facilitate\u00a0higher-resolution analysis with destructive techniques\u00a0 A full workflow that\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced packaging","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1025,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/advanced-packaging-failure-mechanisms-in-the-ai-era-why-reliability-is-shifting-in-2-5d-and-3d-designs\/","url_meta":{"origin":108,"position":2},"title":"Advanced Packaging Failure Mechanisms in the AI Era: Why Reliability Is Shifting in 2.5D and 3D Designs","author":"Vinay S","date":"May 4, 2026","format":false,"excerpt":"Artificial intelligence (AI) is reshaping semiconductor design. As transistor scaling slows, performance gains are increasingly driven by advanced packaging, especially 2.5D interposers, 3D stacking, hybrid bonding, and high-bandwidth memory (HBM) integration. But this shift is doing more than increasing compute density. This move towards advanced packaging is also fundamentally changing\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced Packaging Failure Mechanisms in the AI Era: Why Reliability Is Shifting in 2.5D and 3D Designs","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1136,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/tem-sample-preparation-automation\/","url_meta":{"origin":108,"position":3},"title":"TEM Sample Preparation Automation: Matching the Level to the Workflow\u00a0","author":"Swarnim Rawat","date":"November 17, 2026","format":false,"excerpt":"In most labs, TEM sample capacity depends on the availability of experienced operators who can reliably navigate to the region of interest, perform lift-out, precisely execute thinning and endpointing, recover from interruptions, and train new users to do the same.\u00a0 Automation can reduce that constraint, but not every sample requires\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"Helios Family Blog","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1108,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-semiconductor-characterization\/","url_meta":{"origin":108,"position":4},"title":"From Manual Control to Automated Insights: Versatile FIB-SEM Workflows for Semiconductor Research","author":"Claudia Bernal","date":"November 11, 2026","format":false,"excerpt":"As semiconductor devices become increasingly complex and three-dimensional, researchers need more than one way to access and understand the structures hidden beneath the surface. Some investigations begin with hands-on FIB-SEM operation, where researchers need the freedom to explore an unfamiliar device, locate a region of interest, and optimize the preparation\u2026","rel":"","context":"In &quot;Focused Ion Beam&quot;","block_context":{"text":"Focused Ion Beam","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/focused-ion-beam\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1150,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/electron-microscopy-ai-semiconductor-manufacturing\/","url_meta":{"origin":108,"position":5},"title":"Where Electron Microscopy Fits in the AI Ecosystem","author":"Swarnim Rawat","date":"November 16, 2026","format":false,"excerpt":"Artificial intelligence is often discussed in terms of algorithms, models, and compute performance. Headlines focus on GPUs, large-scale training clusters, and new model capabilities. But beneath that visible layer lies a complex ecosystem, one that spans chip design, fabrication, packaging, and data storage. What ultimately determines the pace of AI\u2026","rel":"","context":"In &quot;DualBeam (FIB-SEM)&quot;","block_context":{"text":"DualBeam (FIB-SEM)","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/dualbeam-fib-sem\/"},"img":{"alt_text":"Abstract of an AI chip and crystal lattice","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/3d20nand20deprocessing.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/108","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/users\/1346"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/comments?post=108"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/108\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media\/110"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media?parent=108"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/categories?post=108"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/tags?post=108"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/division?post=108"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}