{"id":18,"date":"2021-06-02T13:24:44","date_gmt":"2021-06-02T13:24:44","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/semiconductors\/2021\/06\/02\/environmental-interference-in-semiconductor-failure-analysis\/"},"modified":"2026-03-03T00:22:35","modified_gmt":"2026-03-03T00:22:35","slug":"environmental-interference-in-semiconductor-failure-analysis","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/","title":{"rendered":"How to Mitigate Environmental Interference During Semiconductor Failure Analysis"},"content":{"rendered":"<p>During the last year, the importance of semiconductors and the fragile balance between supply and demand became clear. Chip shortages are propelling manufacturers to make new investments in the semiconductor failure analysis process, so they can accelerate yield learnings and process improvements, and better meet demand.<\/p>\n<p>As companies install new instruments and technologies in their labs and fabs, it is important they also <a href=\"https:\/\/ter.li\/rodkup\" target=\"_blank\" rel=\"noopener\">minimize environmental interference<\/a> and other factors that may result in suboptimal instrument performance.<\/p>\n<p>Vibration, created by internal and external sources can stem from HVAC equipment, construction, or even foot traffic. Acoustic noise sources can include air handling systems and people talking. EMI can find its way into \u00a0systems from transformers, subways, and other electric sources in the area.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Case study: when environmental interference causes image distortion<\/strong><\/h2>\n<p>While many companies consider the implications of floor vibrations in the site preparation process, it is also important to consider acoustics, electromagnetic interference (EMI) and other vibration sources.<\/p>\n<p>Environmental factors can negatively impact semiconductor failure analysis productivity, as outlined in a real-world case study from Thermo Fisher Scientific.<\/p>\n<p>Approximately five years ago, while working with customers at our NanoPort in Hillsboro, Oregon, we noticed significant image distortions in our Helios 4 FX DualBeam system.<\/p>\n<p>In fact, the images were of such poor quality that we were unable to perform accurate analysis, and it forced us to suspend the work we were doing with our customer.<\/p>\n<p>This major inconvenience caused a full investigation to get to the root cause of the issue.<\/p>\n<div id=\"attachment_11878\" style=\"width: 510px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11878\" class=\"wp-image-11878\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/efactors-vibration1.jpg\" alt=\"Environmental interference causing image vibration\" width=\"500\" height=\"337\" \/><p id=\"caption-attachment-11878\" class=\"wp-caption-text\">Helios 4 FX Small DualBeam exhibiting image vibration in the STEM mode<\/p><\/div>\n<p>Working with our Site Preparation Services team, we initiated a comprehensive site survey of our NanoPort and the surrounding area.<\/p>\n<p>We performed vibration, acoustic and electromagnetic interference (EMI) measurements, as well as a beam analysis to match the frequencies to their source and quickly determined it was a vibration issue.<\/p>\n<p>Our investigation led us here, where we identified the source as environmental interference:<\/p>\n<div id=\"attachment_11887\" style=\"width: 610px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11887\" class=\"wp-image-11887\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-1-scaled.jpg\" alt=\"Construction project near Hillsboro NanoPort\" width=\"600\" height=\"450\" \/><p id=\"caption-attachment-11887\" class=\"wp-caption-text\">Large, construction project located 1,000 feet from the Thermo Fisher NanoPort in Hillsboro, Oregon. Five years later, construction continues!<\/p><\/div>\n<p>&nbsp;<\/p>\n<h2 style=\"font-size: 100%\"><strong>Mitigation solutions to enhance the semiconductor failure analysis process<\/strong><\/h2>\n<p>Since we couldn\u2019t stop the construction, nor could we move our lab, we focused on targeted mitigation steps to allow us to resume our work.<\/p>\n<p>First, we performed our work during \u201coff\u201d hours. In conducting our site preparation survey, we discovered the construction work ended each day at 5:00 p.m. and the vibration issues disappeared. Employing this step allowed us to resume work while we planned our long-term fix.<\/p>\n<p>Then, we engaged with TMC, a global supplier of vibration isolation products, to develop a custom, active vibration isolation platform \u2014the TMC SEM-Base LP for Thermo Fisher. \u00a0Once installed, the vibration issue was resolved, and we were able to quickly get our system back in action.<\/p>\n<div id=\"attachment_11883\" style=\"width: 508px\" class=\"wp-caption aligncenter\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-11883\" class=\"wp-image-11883 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/efactors-novibration.jpg\" alt=\"Mitigating environmental factors affecting semiconductor instruments\" width=\"498\" height=\"527\" \/><p id=\"caption-attachment-11883\" class=\"wp-caption-text\">Helios 4 FX Small DualBeam vibration free image after solution implementation<\/p><\/div>\n<h2 style=\"font-size: 100%\"><strong>Planning ahead for environmental interference <\/strong><\/h2>\n<p>Vibration, acoustics, and EMI can all affect semiconductor failure analysis instrument performance.<\/p>\n<p>These environmental interference sources can cause a variety of negative effects on the semiconductor failure analysis process, including image distortion, a loss of resolution and data, and zero loss peak instability\u2014making it virtually impossible to perform critical failure analysis work. System downtime can negatively impact failure analysis, yield learning and process monitoring work.<\/p>\n<p>For those building new or redesigning existing labs and fabs, the best time to mitigate environmental interference is before the build or redesign of a lab or fab, or before the installation of an instrument. Conducting a thorough site preparation survey can identify several actions you can take to mitigate the impact of environmental factors before they disrupt operations.<\/p>\n<p><em>Visit our Site Preparation Services <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/services\/site-preparation-package.html\">webpage<\/a> for additional information.<\/em><\/p>\n<p><a href=\"https:\/\/ter.li\/rke9vg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-518 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172.jpg\" alt=\"Subscribe to Thermo Fisher Scientific's semiconductor updates and resources\" width=\"1000\" height=\"172\" srcset=\"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172.jpg 1000w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172-768x132.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>During the last year, the importance of semiconductors and the fragile balance between supply and demand became clear. Chip shortages are propelling manufacturers to make new investments in the semiconductor failure analysis process, so they can accelerate yield learnings and process improvements, and better meet demand. As companies install new instruments and technologies in their<\/p>\n","protected":false},"author":905,"featured_media":22,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[17,20,19],"tags":[16],"division":[],"class_list":["post-18","post","type-post","status-publish","format-standard","has-post-thumbnail","category-dualbeam-fib-sem","category-failure-analysis","category-semiconductor","tag-electronics-semiconductors","entry"],"_selected_authors":[1292,1442],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Semiconductor Failure Analysis- Environmental Interference - Illuminating Semiconductors<\/title>\n<meta name=\"description\" content=\"Environmental interference can negatively impact failure analysis of semiconductor devices. Learn how to reduce environmental interference.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Mitigate Environmental Interference During Semiconductor Failure Analysis\" \/>\n<meta property=\"og:description\" content=\"Environmental interference can negatively impact failure analysis of semiconductor devices. Learn how to reduce environmental interference.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/\" \/>\n<meta property=\"og:site_name\" content=\"Illuminating Semiconductors\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2021-06-02T13:24:44+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-03T00:22:35+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Alex Ilitchev\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Alex Ilitchev\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/\"},\"author\":{\"name\":\"Alex Ilitchev\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/fc75f1f9783064c82dbb5b234bd2820b\"},\"headline\":\"How to Mitigate Environmental Interference During Semiconductor Failure Analysis\",\"datePublished\":\"2021-06-02T13:24:44+00:00\",\"dateModified\":\"2026-03-03T00:22:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/\"},\"wordCount\":646,\"commentCount\":1,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Hillsboro-nanoport-2-scaled-1.jpg\",\"keywords\":[\"Electronics\\\/Semiconductors\"],\"articleSection\":[\"DualBeam (FIB-SEM)\",\"Failure Analysis\",\"Semiconductor\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/\",\"name\":\"Semiconductor Failure Analysis- Environmental Interference - Illuminating Semiconductors\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Hillsboro-nanoport-2-scaled-1.jpg\",\"datePublished\":\"2021-06-02T13:24:44+00:00\",\"dateModified\":\"2026-03-03T00:22:35+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/fc75f1f9783064c82dbb5b234bd2820b\"},\"description\":\"Environmental interference can negatively impact failure analysis of semiconductor devices. Learn how to reduce environmental interference.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Hillsboro-nanoport-2-scaled-1.jpg\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Hillsboro-nanoport-2-scaled-1.jpg\",\"width\":2560,\"height\":1440,\"caption\":\"Environmental interference from construction causing image distortion\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/environmental-interference-in-semiconductor-failure-analysis\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Mitigate Environmental Interference During Semiconductor Failure Analysis\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\",\"name\":\"Illuminating Semiconductors\",\"description\":\"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/fc75f1f9783064c82dbb5b234bd2820b\",\"name\":\"Alex Ilitchev\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/54cef1351cde5037d69bb7709c905d8c8159926c7a8c061899c34f746bb02e6f?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/54cef1351cde5037d69bb7709c905d8c8159926c7a8c061899c34f746bb02e6f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/54cef1351cde5037d69bb7709c905d8c8159926c7a8c061899c34f746bb02e6f?s=96&d=mm&r=g\",\"caption\":\"Alex Ilitchev\"},\"description\":\"Alex Ilitchev, PhD, is a science writer at Thermo Fisher Scientific. They have a background in biophysical chemistry, with a focus on protein misfolding, aggregation, as well as mass spectrometry. Alex supports writing efforts across a variety of analytical instruments and software from Thermo Fisher Scientific, including electron microscopy in the life and materials sciences.\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/alexilitchev\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Semiconductor Failure Analysis- Environmental Interference - Illuminating Semiconductors","description":"Environmental interference can negatively impact failure analysis of semiconductor devices. Learn how to reduce environmental interference.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/","og_locale":"en_US","og_type":"article","og_title":"How to Mitigate Environmental Interference During Semiconductor Failure Analysis","og_description":"Environmental interference can negatively impact failure analysis of semiconductor devices. Learn how to reduce environmental interference.","og_url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/","og_site_name":"Illuminating Semiconductors","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2021-06-02T13:24:44+00:00","article_modified_time":"2026-03-03T00:22:35+00:00","og_image":[{"width":2560,"height":1440,"url":"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg","type":"image\/jpeg"}],"author":"Alex Ilitchev","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Alex Ilitchev","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/"},"author":{"name":"Alex Ilitchev","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/fc75f1f9783064c82dbb5b234bd2820b"},"headline":"How to Mitigate Environmental Interference During Semiconductor Failure Analysis","datePublished":"2021-06-02T13:24:44+00:00","dateModified":"2026-03-03T00:22:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/"},"wordCount":646,"commentCount":1,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg","keywords":["Electronics\/Semiconductors"],"articleSection":["DualBeam (FIB-SEM)","Failure Analysis","Semiconductor"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/","url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/","name":"Semiconductor Failure Analysis- Environmental Interference - Illuminating Semiconductors","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg","datePublished":"2021-06-02T13:24:44+00:00","dateModified":"2026-03-03T00:22:35+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/fc75f1f9783064c82dbb5b234bd2820b"},"description":"Environmental interference can negatively impact failure analysis of semiconductor devices. Learn how to reduce environmental interference.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg","contentUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg","width":2560,"height":1440,"caption":"Environmental interference from construction causing image distortion"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/environmental-interference-in-semiconductor-failure-analysis\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/semiconductors\/"},{"@type":"ListItem","position":2,"name":"How to Mitigate Environmental Interference During Semiconductor Failure Analysis"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/","name":"Illuminating Semiconductors","description":"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/semiconductors\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/fc75f1f9783064c82dbb5b234bd2820b","name":"Alex Ilitchev","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/54cef1351cde5037d69bb7709c905d8c8159926c7a8c061899c34f746bb02e6f?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/54cef1351cde5037d69bb7709c905d8c8159926c7a8c061899c34f746bb02e6f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/54cef1351cde5037d69bb7709c905d8c8159926c7a8c061899c34f746bb02e6f?s=96&d=mm&r=g","caption":"Alex Ilitchev"},"description":"Alex Ilitchev, PhD, is a science writer at Thermo Fisher Scientific. They have a background in biophysical chemistry, with a focus on protein misfolding, aggregation, as well as mass spectrometry. Alex supports writing efforts across a variety of analytical instruments and software from Thermo Fisher Scientific, including electron microscopy in the life and materials sciences.","url":"https:\/\/admin.acceleratingscience.com\/author\/alexilitchev\/"}]}},"taxonomy_info":{"category":[{"value":17,"label":"DualBeam (FIB-SEM)"},{"value":20,"label":"Failure Analysis"},{"value":19,"label":"Semiconductor"}],"post_tag":[{"value":16,"label":"Electronics\/Semiconductors"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1-1024x576.jpg",760,428,true],"author_info":{"display_name":"Alex Ilitchev","author_link":"https:\/\/admin.acceleratingscience.com\/author\/alexilitchev\/"},"comment_info":1,"category_info":[{"term_id":17,"name":"DualBeam (FIB-SEM)","slug":"dualbeam-fib-sem","term_group":0,"term_taxonomy_id":17,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":17,"category_count":14,"category_description":"","cat_name":"DualBeam (FIB-SEM)","category_nicename":"dualbeam-fib-sem","category_parent":0},{"term_id":20,"name":"Failure Analysis","slug":"failure-analysis","term_group":0,"term_taxonomy_id":20,"taxonomy":"category","description":"","parent":0,"count":17,"filter":"raw","meta":[],"cat_ID":20,"category_count":17,"category_description":"","cat_name":"Failure Analysis","category_nicename":"failure-analysis","category_parent":0},{"term_id":19,"name":"Semiconductor","slug":"semiconductor","term_group":0,"term_taxonomy_id":19,"taxonomy":"category","description":"","parent":0,"count":31,"filter":"raw","meta":[],"cat_ID":19,"category_count":31,"category_description":"","cat_name":"Semiconductor","category_nicename":"semiconductor","category_parent":0}],"tag_info":[{"term_id":16,"name":"Electronics\/Semiconductors","slug":"electronics-semiconductors","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":25,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":1079,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/supporting-advanced-packaging-with-integrated-semiconductor-failure-analysis-workflows\/","url_meta":{"origin":18,"position":0},"title":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows","author":"Vinay S","date":"October 22, 2026","format":false,"excerpt":"Key takeaways Semiconductor failure analysis of advanced packaging technologies requires the connection of electrical and physical evidence across multiple length scales to identify root cause. Non-destructive methods such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography can be used to localize defects for subsequent targeted investigation. Focused ion\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1047,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/non-destructive-semiconductor-defect-detection-advanced-packaging-technology\/","url_meta":{"origin":18,"position":1},"title":"Non-Destructive Semiconductor Defect Detection\u00a0in\u00a0Advanced Packaging\u00a0Technology","author":"Swarnim Rawat","date":"July 1, 2026","format":false,"excerpt":"Key highlights Compared to conventional package designs, semiconductor defect detection\u00a0is\u00a0more difficult\u00a0for\u00a0advanced packaging\u00a0because failure sites are smaller,\u00a0more deeply embedded, and\u00a0are\u00a0distributed across more material interfaces\u00a0 Non-destructive techniques such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography provide critical information on advanced\u00a0packages\u00a0that can\u00a0facilitate\u00a0higher-resolution analysis with destructive techniques\u00a0 A full workflow that\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced packaging","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1025,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/advanced-packaging-failure-mechanisms-in-the-ai-era-why-reliability-is-shifting-in-2-5d-and-3d-designs\/","url_meta":{"origin":18,"position":2},"title":"Advanced Packaging Failure Mechanisms in the AI Era: Why Reliability Is Shifting in 2.5D and 3D Designs","author":"Vinay S","date":"May 4, 2026","format":false,"excerpt":"Artificial intelligence (AI) is reshaping semiconductor design. As transistor scaling slows, performance gains are increasingly driven by advanced packaging, especially 2.5D interposers, 3D stacking, hybrid bonding, and high-bandwidth memory (HBM) integration. But this shift is doing more than increasing compute density. This move towards advanced packaging is also fundamentally changing\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced Packaging Failure Mechanisms in the AI Era: Why Reliability Is Shifting in 2.5D and 3D Designs","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1150,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/electron-microscopy-ai-semiconductor-manufacturing\/","url_meta":{"origin":18,"position":3},"title":"Where Electron Microscopy Fits in the AI Ecosystem","author":"Swarnim Rawat","date":"November 16, 2026","format":false,"excerpt":"Artificial intelligence is often discussed in terms of algorithms, models, and compute performance. Headlines focus on GPUs, large-scale training clusters, and new model capabilities. But beneath that visible layer lies a complex ecosystem, one that spans chip design, fabrication, packaging, and data storage. What ultimately determines the pace of AI\u2026","rel":"","context":"In &quot;DualBeam (FIB-SEM)&quot;","block_context":{"text":"DualBeam (FIB-SEM)","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/dualbeam-fib-sem\/"},"img":{"alt_text":"Abstract of an AI chip and crystal lattice","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":625,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/dram-device-dram-fabrication-tem-metrology\/","url_meta":{"origin":18,"position":4},"title":"Enhancing High-Volume DRAM Manufacturing with Automated TEM Metrology and Characterization","author":"Xiaoting Gu","date":"November 6, 2025","format":false,"excerpt":"Dynamic random-access memory (DRAM) plays a crucial role in computing devices, providing fast access to essential data and allowing them to operate at peak performance. For DRAM device manufacturers, scaling is important as it enables lower cost per unit area by enabling reductions in DRAM cell size. However, as DRAM\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"DRAM memory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1108,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-semiconductor-characterization\/","url_meta":{"origin":18,"position":5},"title":"From Manual Control to Automated Insights: Versatile FIB-SEM Workflows for Semiconductor Research","author":"Claudia Bernal","date":"November 11, 2026","format":false,"excerpt":"As semiconductor devices become increasingly complex and three-dimensional, researchers need more than one way to access and understand the structures hidden beneath the surface. Some investigations begin with hands-on FIB-SEM operation, where researchers need the freedom to explore an unfamiliar device, locate a region of interest, and optimize the preparation\u2026","rel":"","context":"In &quot;Focused Ion Beam&quot;","block_context":{"text":"Focused Ion Beam","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/focused-ion-beam\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Hillsboro-nanoport-2-scaled-1.jpg","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/18","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/users\/905"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/comments?post=18"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/18\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media\/22"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media?parent=18"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/categories?post=18"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/tags?post=18"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/division?post=18"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}