{"id":30,"date":"2025-06-18T20:33:20","date_gmt":"2025-06-18T20:33:20","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/semiconductors\/2021\/07\/13\/physical-electrical-failure-analysis-power-semiconductor-devices\/"},"modified":"2026-03-02T22:25:47","modified_gmt":"2026-03-02T22:25:47","slug":"physical-electrical-failure-analysis-power-semiconductor-devices","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/","title":{"rendered":"Physical and Electrical Failure Analysis of Power Semiconductor Devices"},"content":{"rendered":"<p>World energy consumption is expected to grow by nearly 50% between 2018 and 2050. As much of our power shifts over to electricity, higher-efficiency, compact power semiconductor devices, such as diodes, IGBTs, MOSFETs and HEMTs are needed to run everything from smart phones and electric vehicles to industrial robots.<\/p>\n<p>Today, the semiconductor industry is moving beyond silicon to develop the next generation of power devices. <a href=\"https:\/\/ter.li\/ta1ehk\">Wide bandgap power devices<\/a> make it possible to build higher performance, more reliable components that improve power efficiency and operate at higher temperatures. Unfortunately, these materials can introduce new failure modes\u2014and using traditional electrical failure analysis to identify root cause can be challenging, potentially impacting operational reliability and manufacturing yields.<\/p>\n<p>Take silicon metal-oxide semiconductor field-effect transistors (MOSFETs), for example. These transistors, designed to handle high power requirements, are the workhorse for a majority of switching power applications. Yet as higher voltages and frequencies are packaged into ever smaller form factors, the performance of these power MOSFETs is reaching its limit.<\/p>\n<p>By redesigning power MOSFETs using new semiconductor materials such as silicon carbide and gallium nitride, engineers can develop cost-effective solutions for power switching that meet the needs for highly efficient and compact power semiconductor devices.<\/p>\n<h2 style=\"font-size: 100%\"><strong>The limits of traditional <\/strong><strong>electrical failure analysis methods<\/strong><\/h2>\n<p>As engineers design these devices, the main challenge is eliminating circuit shorts. Unlike integrated circuits made up of billions of tiny transistors connected by layers of thin wires, power devices are composed of one transistor with one thin wire that\u2019s completely covered by a single sheet of metal. This design makes it difficult to isolate and characterize small leakage paths\u2014and requires different electrical failure analysis methodologies than were used in the past.<\/p>\n<p>Emission microscopy and optical beam induced resistivity change (OBIRCH) are the traditional methods for pinpointing power MOSFET failure modes. Yet these methods are hampered by the thick sheet of metal covering the surface. To overcome this limitation, engineers sometimes use reactive ions or wet chemicals to open windows into the metal to better access the failure. The downside of this method is reproducibility is low and the likelihood of completely disabling the device is high.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-12040 size-large\" title=\"Thermo Fisher Scientific electrical failure analysis to physical failure analysis workflow\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/EFA2PFA-workflow-1024x325.png\" alt=\"Thermo Fisher Scientific electrical failure analysis to physical failure analysis workflow\" width=\"760\" height=\"241\" \/><\/p>\n<p style=\"text-align: center\"><em>New methods are needed as engineers work to design state-of-the-art power devices that include wide bandgap materials<\/em><\/p>\n<h2 style=\"font-size: 100%\"><strong>A robust workflow for next-generation power semiconductor devices<\/strong><\/h2>\n<p>To address these issues, Thermo Fisher Scientific <a href=\"https:\/\/ter.li\/khuvx8\">developed a robust workflow<\/a> that combines electrical failure analysis (EFA) to isolate faults and physical failure analysis (PFA) to characterize the microstructure\u2014helping engineers to pinpoint anomalous electrical behavior at the microstructural level. Not only is this workflow faster and more accurate, but it generates repeatable results with little to no destruction of the device.<\/p>\n<hr \/>\n<p><em>Read our latest application note: <\/em><strong><em><a href=\"https:\/\/ter.li\/ta1ehk\" target=\"_blank\" rel=\"noopener\">Transforming failure analysis of wide bandgap power MOS devices &gt;&gt;<\/a><br \/>\n<\/em><\/strong><\/p>\n<hr \/>\n<p>The workflow involves the following steps:<\/p>\n<h2 style=\"font-size: 100%\"><strong>Electrical failure analysis of power semiconductor devices<\/strong><\/h2>\n<ul>\n<li><em>Localizing the region of interest: <\/em>The <a href=\"https:\/\/ter.li\/802im8\">Thermo Scientific ELITE System<\/a> is used to coarsely isolate the fault by detecting heat emitted anywhere on the device, regardless of the presence of the sheet of metal covering the surface. What makes ELITE unique is the ability to lock in the detector to a ramped bias and acquire separate amplitude and phase signals. Amplitude is the same signal as a basic thermal microscope, and it generally provides a misleading failure location. The ELITE\u2019s phase signal overcomes this problem with its increased sensitivity to the source of the heat, rather than where the heat accumulates.<\/li>\n<li><em>Opening a window through the metal sheet:<\/em> The <a href=\"https:\/\/www.thermofisher.com\/us\/en\/home\/electron-microscopy\/products\/dualbeam-fib-sem-microscopes\/helios-5-pfib-dualbeam.html\">Thermo Scientific Helios 5 PFIB DualBeam<\/a> uses a fine beam of inert gas ions to open a window in the metal sheet at the location indicated by the ELITE. A gas is flowed over the sample to produce a uniformly flat-bottomed opening over the device. The electron microscope in the DualBeam is used to stop the ion milling process precisely at an appropriate layer within the device. In some cases, the \u201cdelayering\u201d stops when the metal sheet is removed, and the source contacts are just exposed. In other cases, the device is delayered further into the gate electrode. Under this sample preparation protocol, the power semiconductor device remains fully functional, with the behavior of the original part unchanged.<\/li>\n<li><em>Nanoprobing to further localize the defect:<\/em> If the defect isn\u2019t exposed during the PFIB delayering step, nanoprobing is applied to further localize the fault. Scanning electron microscope (SEM) nanoprobing using the <a href=\"https:\/\/ter.li\/zgojc9\">Thermo Scientific nProber IV System,<\/a> or atomic-force probing using the <a href=\"https:\/\/ter.li\/csewbg\">Thermo Scientific Hyperion System<\/a> positions fine probes in discrete locations of the region of interest to extract current-voltage curves. Anomalies in the current-voltage curve reveal the location of the fault and indicate the volume of material that must be examined to find the defect using physical fault analysis.<\/li>\n<\/ul>\n<h2 style=\"font-size: 100%\"><strong>Physical failure analysis of power semiconductor devices<\/strong><\/h2>\n<ul>\n<li><em>Characterizing the microstructure responsible for the failure:<\/em> The Helios 5 PFIB DualBeam is used to prepare the sample using two possible approaches:<\/li>\n<li><em>Slice and view:<\/em> This technique involves making a series of FIB cuts followed by SEM imaging as cuts are made through the material until the defect is found. If more detailed imaging is required to characterize the defect, a thin sample can be prepared and imaged using a scanning transmission electron microscope (STEM) such as the <a href=\"https:\/\/ter.li\/ylxe2d\">Thermo Scientific Talos Transmission Electron Microscope (TEM)<\/a>.<\/li>\n<li><em>Direct to the Talos TEM:<\/em> The alternative sample prep approach is to extract a piece of the material up to a few microns thick using the Helios PFIB DualBeam and move the sample directly into the Talos TEM. This is the fastest approach, but thicker samples may require additional thinning and analysis to conclusively characterize the defect.<\/li>\n<\/ul>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-large wp-image-12041\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Picture1-1024x308.jpg\" alt=\"Dopant revealed in a Silicon Carbide IGBT\" width=\"760\" height=\"229\" \/><\/p>\n<p style=\"text-align: center\"><em>Dopant revealed in a Silicon Carbide IGBT<\/em><\/p>\n<p>As engineers design state-of-the-art power management solutions, they need new failure analysis methods that help them to precisely isolate and characterize faults. Thermo Fisher\u2019s EFA to PFA workflow offers a fast and accurate way to improve power device quality\u2014paving the way for the next generation of power devices needed to power our global economy.<\/p>\n<p><a href=\"https:\/\/ter.li\/rke9vg\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-518 size-full\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172.jpg\" alt=\"Subscribe to Thermo Fisher Scientific's semiconductor updates and resources\" width=\"1000\" height=\"172\" srcset=\"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172.jpg 1000w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172-300x52.jpg 300w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2023\/07\/Opt-in-Banner_1000x172-768x132.jpg 768w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/a><\/p>\n<p>\/\/<\/p>\n<p><em>Written in collaboration with Roger Alvis, lead product specialist at Thermo Fisher Scientific. <\/em><\/p>\n","protected":false},"excerpt":{"rendered":"<p>World energy consumption is expected to grow by nearly 50% between 2018 and 2050. As much of our power shifts over to electricity, higher-efficiency, compact power semiconductor devices, such as diodes, IGBTs, MOSFETs and HEMTs are needed to run everything from smart phones and electric vehicles to industrial robots. Today, the semiconductor industry is moving<\/p>\n","protected":false},"author":1484,"featured_media":38,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[17,20,19,23],"tags":[16],"division":[],"class_list":["post-30","post","type-post","status-publish","format-standard","has-post-thumbnail","category-dualbeam-fib-sem","category-failure-analysis","category-semiconductor","category-transmission-electron-microscopy","tag-electronics-semiconductors","entry"],"_selected_authors":[1442],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.9 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Power Semiconductor Devices - Electrical Failure Analysis - Illuminating Semiconductors<\/title>\n<meta name=\"description\" content=\"Power semiconductor devices can use physical and electrical failure analysis for fast and accurate defect pinpointing.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Physical and Electrical Failure Analysis of Power Semiconductor Devices\" \/>\n<meta property=\"og:description\" content=\"Power semiconductor devices can use physical and electrical failure analysis for fast and accurate defect pinpointing.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/\" \/>\n<meta property=\"og:site_name\" content=\"Illuminating Semiconductors\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2025-06-18T20:33:20+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-03-02T22:25:47+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Roger Alvis\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Roger Alvis\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/\"},\"author\":{\"name\":\"Roger Alvis\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/05b4d92fe459c82f767f4f809091539c\"},\"headline\":\"Physical and Electrical Failure Analysis of Power Semiconductor Devices\",\"datePublished\":\"2025-06-18T20:33:20+00:00\",\"dateModified\":\"2026-03-02T22:25:47+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/\"},\"wordCount\":1021,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Untitled-design-7.png\",\"keywords\":[\"Electronics\\\/Semiconductors\"],\"articleSection\":[\"DualBeam (FIB-SEM)\",\"Failure Analysis\",\"Semiconductor\",\"Transmission Electron Microscopy\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/\",\"name\":\"Power Semiconductor Devices - Electrical Failure Analysis - Illuminating Semiconductors\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Untitled-design-7.png\",\"datePublished\":\"2025-06-18T20:33:20+00:00\",\"dateModified\":\"2026-03-02T22:25:47+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/05b4d92fe459c82f767f4f809091539c\"},\"description\":\"Power semiconductor devices can use physical and electrical failure analysis for fast and accurate defect pinpointing.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Untitled-design-7.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2022\\\/04\\\/Untitled-design-7.png\",\"width\":1200,\"height\":630,\"caption\":\"Physical and electrical failure analysis for power devices\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/physical-electrical-failure-analysis-power-semiconductor-devices\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Physical and Electrical Failure Analysis of Power Semiconductor Devices\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\",\"name\":\"Illuminating Semiconductors\",\"description\":\"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/05b4d92fe459c82f767f4f809091539c\",\"name\":\"Roger Alvis\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d9a34621fe7a15d99f6c85f4176f870c76c3418c9ccd445957424328adeed661?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d9a34621fe7a15d99f6c85f4176f870c76c3418c9ccd445957424328adeed661?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/d9a34621fe7a15d99f6c85f4176f870c76c3418c9ccd445957424328adeed661?s=96&d=mm&r=g\",\"caption\":\"Roger Alvis\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/rogeralvis\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Power Semiconductor Devices - Electrical Failure Analysis - Illuminating Semiconductors","description":"Power semiconductor devices can use physical and electrical failure analysis for fast and accurate defect pinpointing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/","og_locale":"en_US","og_type":"article","og_title":"Physical and Electrical Failure Analysis of Power Semiconductor Devices","og_description":"Power semiconductor devices can use physical and electrical failure analysis for fast and accurate defect pinpointing.","og_url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/","og_site_name":"Illuminating Semiconductors","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2025-06-18T20:33:20+00:00","article_modified_time":"2026-03-02T22:25:47+00:00","og_image":[{"width":1200,"height":630,"url":"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png","type":"image\/png"}],"author":"Roger Alvis","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"Roger Alvis","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/"},"author":{"name":"Roger Alvis","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/05b4d92fe459c82f767f4f809091539c"},"headline":"Physical and Electrical Failure Analysis of Power Semiconductor Devices","datePublished":"2025-06-18T20:33:20+00:00","dateModified":"2026-03-02T22:25:47+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/"},"wordCount":1021,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png","keywords":["Electronics\/Semiconductors"],"articleSection":["DualBeam (FIB-SEM)","Failure Analysis","Semiconductor","Transmission Electron Microscopy"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/","url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/","name":"Power Semiconductor Devices - Electrical Failure Analysis - Illuminating Semiconductors","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png","datePublished":"2025-06-18T20:33:20+00:00","dateModified":"2026-03-02T22:25:47+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/05b4d92fe459c82f767f4f809091539c"},"description":"Power semiconductor devices can use physical and electrical failure analysis for fast and accurate defect pinpointing.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png","width":1200,"height":630,"caption":"Physical and electrical failure analysis for power devices"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/physical-electrical-failure-analysis-power-semiconductor-devices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/semiconductors\/"},{"@type":"ListItem","position":2,"name":"Physical and Electrical Failure Analysis of Power Semiconductor Devices"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/","name":"Illuminating Semiconductors","description":"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/semiconductors\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/05b4d92fe459c82f767f4f809091539c","name":"Roger Alvis","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/d9a34621fe7a15d99f6c85f4176f870c76c3418c9ccd445957424328adeed661?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/d9a34621fe7a15d99f6c85f4176f870c76c3418c9ccd445957424328adeed661?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d9a34621fe7a15d99f6c85f4176f870c76c3418c9ccd445957424328adeed661?s=96&d=mm&r=g","caption":"Roger Alvis"},"url":"https:\/\/admin.acceleratingscience.com\/author\/rogeralvis\/"}]}},"taxonomy_info":{"category":[{"value":17,"label":"DualBeam (FIB-SEM)"},{"value":20,"label":"Failure Analysis"},{"value":19,"label":"Semiconductor"},{"value":23,"label":"Transmission Electron Microscopy"}],"post_tag":[{"value":16,"label":"Electronics\/Semiconductors"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7-1024x538.png",760,399,true],"author_info":{"display_name":"Roger Alvis","author_link":"https:\/\/admin.acceleratingscience.com\/author\/rogeralvis\/"},"comment_info":0,"category_info":[{"term_id":17,"name":"DualBeam (FIB-SEM)","slug":"dualbeam-fib-sem","term_group":0,"term_taxonomy_id":17,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":17,"category_count":14,"category_description":"","cat_name":"DualBeam (FIB-SEM)","category_nicename":"dualbeam-fib-sem","category_parent":0},{"term_id":20,"name":"Failure Analysis","slug":"failure-analysis","term_group":0,"term_taxonomy_id":20,"taxonomy":"category","description":"","parent":0,"count":17,"filter":"raw","meta":[],"cat_ID":20,"category_count":17,"category_description":"","cat_name":"Failure Analysis","category_nicename":"failure-analysis","category_parent":0},{"term_id":19,"name":"Semiconductor","slug":"semiconductor","term_group":0,"term_taxonomy_id":19,"taxonomy":"category","description":"","parent":0,"count":31,"filter":"raw","meta":[],"cat_ID":19,"category_count":31,"category_description":"","cat_name":"Semiconductor","category_nicename":"semiconductor","category_parent":0},{"term_id":23,"name":"Transmission Electron Microscopy","slug":"transmission-electron-microscopy","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":23,"category_count":14,"category_description":"","cat_name":"Transmission Electron Microscopy","category_nicename":"transmission-electron-microscopy","category_parent":0}],"tag_info":[{"term_id":16,"name":"Electronics\/Semiconductors","slug":"electronics-semiconductors","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":25,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":1079,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/supporting-advanced-packaging-with-integrated-semiconductor-failure-analysis-workflows\/","url_meta":{"origin":30,"position":0},"title":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows","author":"Vinay S","date":"October 22, 2026","format":false,"excerpt":"Key takeaways Semiconductor failure analysis of advanced packaging technologies requires the connection of electrical and physical evidence across multiple length scales to identify root cause. Non-destructive methods such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography can be used to localize defects for subsequent targeted investigation. Focused ion\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1047,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/non-destructive-semiconductor-defect-detection-advanced-packaging-technology\/","url_meta":{"origin":30,"position":1},"title":"Non-Destructive Semiconductor Defect Detection\u00a0in\u00a0Advanced Packaging\u00a0Technology","author":"Swarnim Rawat","date":"July 1, 2026","format":false,"excerpt":"Key highlights Compared to conventional package designs, semiconductor defect detection\u00a0is\u00a0more difficult\u00a0for\u00a0advanced packaging\u00a0because failure sites are smaller,\u00a0more deeply embedded, and\u00a0are\u00a0distributed across more material interfaces\u00a0 Non-destructive techniques such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography provide critical information on advanced\u00a0packages\u00a0that can\u00a0facilitate\u00a0higher-resolution analysis with destructive techniques\u00a0 A full workflow that\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced packaging","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1025,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/advanced-packaging-failure-mechanisms-in-the-ai-era-why-reliability-is-shifting-in-2-5d-and-3d-designs\/","url_meta":{"origin":30,"position":2},"title":"Advanced Packaging Failure Mechanisms in the AI Era: Why Reliability Is Shifting in 2.5D and 3D Designs","author":"Vinay S","date":"May 4, 2026","format":false,"excerpt":"Artificial intelligence (AI) is reshaping semiconductor design. As transistor scaling slows, performance gains are increasingly driven by advanced packaging, especially 2.5D interposers, 3D stacking, hybrid bonding, and high-bandwidth memory (HBM) integration. But this shift is doing more than increasing compute density. This move towards advanced packaging is also fundamentally changing\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced Packaging Failure Mechanisms in the AI Era: Why Reliability Is Shifting in 2.5D and 3D Designs","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/05\/why-ai-demands-blog-header-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1150,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/electron-microscopy-ai-semiconductor-manufacturing\/","url_meta":{"origin":30,"position":3},"title":"Where Electron Microscopy Fits in the AI Ecosystem","author":"Swarnim Rawat","date":"November 16, 2026","format":false,"excerpt":"Artificial intelligence is often discussed in terms of algorithms, models, and compute performance. Headlines focus on GPUs, large-scale training clusters, and new model capabilities. But beneath that visible layer lies a complex ecosystem, one that spans chip design, fabrication, packaging, and data storage. What ultimately determines the pace of AI\u2026","rel":"","context":"In &quot;DualBeam (FIB-SEM)&quot;","block_context":{"text":"DualBeam (FIB-SEM)","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/dualbeam-fib-sem\/"},"img":{"alt_text":"Abstract of an AI chip and crystal lattice","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1108,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-semiconductor-characterization\/","url_meta":{"origin":30,"position":4},"title":"From Manual Control to Automated Insights: Versatile FIB-SEM Workflows for Semiconductor Research","author":"Claudia Bernal","date":"November 11, 2026","format":false,"excerpt":"As semiconductor devices become increasingly complex and three-dimensional, researchers need more than one way to access and understand the structures hidden beneath the surface. Some investigations begin with hands-on FIB-SEM operation, where researchers need the freedom to explore an unfamiliar device, locate a region of interest, and optimize the preparation\u2026","rel":"","context":"In &quot;Focused Ion Beam&quot;","block_context":{"text":"Focused Ion Beam","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/focused-ion-beam\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":625,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/dram-device-dram-fabrication-tem-metrology\/","url_meta":{"origin":30,"position":5},"title":"Enhancing High-Volume DRAM Manufacturing with Automated TEM Metrology and Characterization","author":"Xiaoting Gu","date":"November 6, 2025","format":false,"excerpt":"Dynamic random-access memory (DRAM) plays a crucial role in computing devices, providing fast access to essential data and allowing them to operate at peak performance. For DRAM device manufacturers, scaling is important as it enables lower cost per unit area by enabling reductions in DRAM cell size. However, as DRAM\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"DRAM memory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2022\/04\/Untitled-design-7.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/30","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/users\/1484"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/comments?post=30"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/30\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media\/38"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media?parent=30"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/categories?post=30"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/tags?post=30"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/division?post=30"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}