{"id":326,"date":"2025-08-29T05:11:59","date_gmt":"2025-08-29T05:11:59","guid":{"rendered":"https:\/\/admin.acceleratingscience.com\/semiconductors\/?p=326"},"modified":"2025-08-29T05:12:03","modified_gmt":"2025-08-29T05:12:03","slug":"fib-sem-sample-preparation","status":"publish","type":"post","link":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/","title":{"rendered":"Removing Large Volumes of Material Fast with FIB-SEMs"},"content":{"rendered":"<p>Focused ion beam scanning electron microscopes (FIB-SEMs) are essential tools for preparing high-quality semiconductor samples for failure analysis and metrology. As semiconductors become more complex with 3D structures, packaged dies, novel materials, and higher circuit density, obtaining statistically relevant data with sub-nanometer accuracy is crucial for identifying defects and out-of-tolerance process steps.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Why is High-Quality Sample Preparation Critical for Semiconductor Analysis?<\/strong><\/h2>\n<p>A high-quality sample devoid of damage and artifacts is required for various analytical tasks:<\/p>\n<ul>\n<li>Removing large volumes of material to locate nanometer-scale defects in large areas<\/li>\n<li>Removing small volumes of materials for site-specific analysis<\/li>\n<li>Preparing lamellae for transmission electron microscopy (TEM) analysis<\/li>\n<\/ul>\n<p>Each of these applications presents unique challenges that can affect sample quality. This article focuses on high-speed, large-volume material removal and the characteristics needed in FIB-SEM systems to address these challenges.<\/p>\n<h2 style=\"font-size: 100%\"><strong>What Challenges Arise When Removing Large Volumes of Material?<\/strong><\/h2>\n<p>When performing large-volume material removal across semiconductor samples, three primary challenges emerge:<\/p>\n<ol>\n<li>Curtaining effects<\/li>\n<li>Sample damage<\/li>\n<li>Handling dissimilar materials<\/li>\n<\/ol>\n<p>The correct FIB-SEM system can help mitigate these challenges and deliver high-quality samples for analysis.<\/p>\n<h2 style=\"font-size: 100%\"><strong>How Do Curtaining Effects Impact Large-Volume Material Removal?<\/strong><\/h2>\n<p>Curtaining occurs when milling with variable milling rates through samples that contain different materials. This interaction creates variations in topography that appear as scratches or striations on the milled face, potentially making detailed analysis difficult or impossible.<\/p>\n<p>While curtaining can affect both small-volume and large-volume sample preparation, it propagates more rapidly with dissimilar materials and large cross-sections. To address this issue, look for instruments that support capabilities such as rocking polish.<\/p>\n<h2 style=\"font-size: 100%\"><strong>What is Spin Mill and How Does it Help?<\/strong><\/h2>\n<p>For uniform large-area planar milling, the spin mill technique is valuable. This process removes a thin layer from the sample surface at a nearly glancing angle while periodically rotating the stage to pre-defined milling sites. This efficiently removes material over a large planar area, providing a smooth surface for imaging, nanoprobing, or additional cross-sectioning work.<\/p>\n<p>Both the Thermo Scientific Helios 5 PFIB-SEM and the Helios 5 Laser PFIB-SEM offer cross-sectioning and spin mill capabilities for large-volume material removal.<\/p>\n<h2 style=\"font-size: 100%\"><strong>How Do Different Laser Types Affect Sample Quality?<\/strong><\/h2>\n<p>When quickly removing large volumes of material over large areas, lasers offer unparalleled speed. While a plasma FIB (PFIB) enables material removal at approximately 10^6 \u03bcm\u00b3\/hr, a laser can remove approximately 10 mm\u00b3\/hr. However, not all lasers provide the same milling characteristics.<\/p>\n<p>&#8220;Nanosecond&#8221; lasers can effectively remove material by ablation but may cause unwanted damage to surrounding areas. Microcracking can form in a large heat-affected zone due to thermal stresses, shock waves, and material melting and cooling.<\/p>\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"483\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Long-vs-Short-Pulse-laser-1024x483-1.png\" alt=\"Diagram showing large heat-affected zone from nanosecond laser pulse versus minimal thermal impact from femtosecond laser pulse.\" class=\"wp-image-852\" title=\"Diagram showing large heat-affected zone from nanosecond laser pulse versus minimal thermal impact from femtosecond laser pulse.\" srcset=\"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Long-vs-Short-Pulse-laser-1024x483-1.png 1024w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Long-vs-Short-Pulse-laser-1024x483-1-300x142.png 300w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Long-vs-Short-Pulse-laser-1024x483-1-768x362.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Comparison of heat impact zones from nanosecond and femtosecond laser pulses.<br><strong>Randolph, Steven &amp; Filevich, Jorge &amp; Botman, Aurelien et al. (2018). In situ femtosecond pulse laser ablation for large volume 3D analysis in scanning electron microscope systems. Journal of Vacuum Science &amp; Technology B. 36. 06JB01. 10.1116\/1.5047806.<\/strong><\/figcaption><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>Why Are Femtosecond Lasers Preferred?<\/strong><\/h2>\n<p>Femtosecond (fs) lasers propagate energy in short pulses with greater instantaneous intensity. This quickly accelerates local ablation, preventing thermal energy transfer to surrounding material. Most of the absorbed energy gasifies the solid phase into plasma, minimizing thermal damage.<\/p>\n<p>For optimal results, solutions that utilize an integrated femtosecond laser in a single chamber, such as the Thermo Scientific Helios 5 Laser PFIB-SEM, are recommended. This integration eliminates navigation misalignments and potential sample contamination that can occur with two-chamber systems or <em>ex situ<\/em> lasers.<\/p>\n<h2 style=\"font-size: 100%\"><strong>What Challenges Arise When Preparing Samples with Dissimilar Materials?<\/strong><\/h2>\n<p>Preparing samples with multiple types of stacked material is increasingly common, especially in 2.5D and 3D packages. These structures contain several hierarchal packaging levels with single or multiple dies, resulting in packages containing disparate materials, some soft and some hard like silicon carbide (SiC).<\/p>\n<p>Stacked materials with different sputter rates can cause extreme curtaining and introduce unwanted thermal behaviors, potentially damaging the sample and hindering proper analysis.<\/p>\n<h2 style=\"font-size: 100%\"><strong>How Do Ion Species and Beam Angle Affect Material Removal?<\/strong><\/h2>\n<p>Two factors significantly impact the ability to remove large volumes of material and produce high-quality samples with dissimilar materials:<\/p>\n<ol>\n<li>Ion species<\/li>\n<li>Angle of incidence of the beam to the sample<\/li>\n<\/ol>\n<p>Different ion species mill more uniformly for different substrate types:<\/p>\n<ul>\n<li>Xenon (Xe) and argon (Ar) are non-interactive ion species ideal for cross-sectioning<\/li>\n<li>Oxygen (O) interacts both chemically and physically during milling, making it extremely effective for hard materials like silicon carbide (SiC), diamond, and other carbon-containing materials<\/li>\n<\/ul>\n\n\n<figure class=\"wp-block-image aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"447\" src=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Hydra-Xe-vs-Ar-image-1024x483-1.png\" alt=\"Side-by-side microscope images showing differences in surface quality and milling time between xenon-prepared (1:42 at 2.5 \u03bcA) and argon-prepared (58 s at 3.7 \u03bcA) silicon samples.\" class=\"wp-image-856\" title=\"Side-by-side microscope images showing differences in surface quality and milling time between xenon-prepared (1:42 at 2.5 \u03bcA) and argon-prepared (58 s at 3.7 \u03bcA) silicon samples.\" srcset=\"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Hydra-Xe-vs-Ar-image-1024x483-1.png 1024w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Hydra-Xe-vs-Ar-image-1024x483-1-300x131.png 300w, https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Hydra-Xe-vs-Ar-image-1024x483-1-768x335.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><figcaption class=\"wp-element-caption\">Comparison of monocrystalline silicon samples prepared with Xe+ and Ar+ ions.<\/figcaption><\/figure>\n\n\n<p>For samples containing multiple material types, the flexibility to switch between ion beam species in minutes is essential. The Thermo Scientific Helios 5 Hydra DualBeam offers this capability, making it invaluable for preparing and analyzing complex samples.<\/p>\n<h2 style=\"font-size: 100%\"><strong>Comparison of FIB-SEM Technologies for Large-Volume Material Removal<\/strong><\/h2>\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>Technology<\/strong><\/td><td><strong>Material Removal Rate<\/strong><\/td><td><strong>Best Applications<\/strong><\/td><td><strong>Key Advantages<\/strong><\/td><\/tr><tr><td>Plasma FIB<\/td><td>~10^6 \u03bcm\u00b3\/hr<\/td><td>Large-area cross-sectioning, spin mill<\/td><td>Balanced speed and precision<\/td><\/tr><tr><td>Laser PFIB<\/td><td>~10 mm\u00b3\/hr<\/td><td>Very large volume removal<\/td><td>Fastest material removal, integrated workflow<\/td><\/tr><tr><td>Multi-Ion Hydra<\/td><td>Varies by ion species<\/td><td>Samples with dissimilar materials<\/td><td>Flexibility to optimize for different materials<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<h2 style=\"font-size: 100%\"><strong>Summary<\/strong><\/h2>\n<p>Modern semiconductor sample preparation requires solutions for a wide variety of applications. When performing large-volume material removal, challenges such as curtaining, sample damage, and handling dissimilar materials can be mitigated with the appropriate FIB-SEM technology:<\/p>\n<ul>\n<li>Curtaining effects can be addressed with techniques like rocking polish and spin mill<\/li>\n<li>Femtosecond lasers minimize thermal damage when removing large volumes of material<\/li>\n<li>Different ion species (Xe, Ar, O) provide optimal milling for different material types<\/li>\n<li>Integrated systems eliminate navigation misalignments and sample contamination<\/li>\n<\/ul>\n<p>The Thermo Scientific Helios 5 DualBeam family, including the PFIB, Laser PFIB, and Hydra systems, offers solutions tailored to these challenges, enabling high-quality sample preparation for advanced semiconductor analysis.<\/p>","protected":false},"excerpt":{"rendered":"<p>Focused ion beam scanning electron microscopes (FIB-SEMs) are essential tools for preparing high-quality semiconductor samples for failure analysis and metrology. As semiconductors become more complex with 3D structures, packaged dies, novel materials, and higher circuit density, obtaining statistically relevant data with sub-nanometer accuracy is crucial for identifying defects and out-of-tolerance process steps. Why is High-Quality<\/p>\n","protected":false},"author":1346,"featured_media":847,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_monsterinsights_skip_tracking":false,"_genesis_hide_title":false,"_genesis_hide_breadcrumbs":false,"_genesis_hide_singular_image":false,"_genesis_hide_footer_widgets":false,"_genesis_custom_body_class":"","_genesis_custom_post_class":"","_genesis_layout":"","_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[17,25,19,23],"tags":[28,16,69,92],"division":[],"class_list":["post-326","post","type-post","status-publish","format-standard","has-post-thumbnail","category-dualbeam-fib-sem","category-general","category-semiconductor","category-transmission-electron-microscopy","tag-dualbeam","tag-electronics-semiconductors","tag-failure-analysis","tag-laser-ablation","entry"],"_selected_authors":[],"_selected_reviewers":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v27.8 (Yoast SEO v27.8) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>FIB-SEM - Sample Preparation - Illuminating Semiconductors<\/title>\n<meta name=\"description\" content=\"Sample preparation challenges associated with large volume material removal and the characteristics needed in a FIB-SEM.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Removing Large Volumes of Material Fast with FIB-SEMs\" \/>\n<meta property=\"og:description\" content=\"Sample preparation challenges associated with large volume material removal and the characteristics needed in a FIB-SEM.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/\" \/>\n<meta property=\"og:site_name\" content=\"Illuminating Semiconductors\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/thermofisher\" \/>\n<meta property=\"article:published_time\" content=\"2025-08-29T05:11:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-08-29T05:12:03+00:00\" \/>\n<meta property=\"og:image\" content=\"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"David Akerson\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:site\" content=\"@thermofisher\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"David Akerson\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/\"},\"author\":{\"name\":\"David Akerson\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/7dfc8535eee862bd1f8d905c8b6cb663\"},\"headline\":\"Removing Large Volumes of Material Fast with FIB-SEMs\",\"datePublished\":\"2025-08-29T05:11:59+00:00\",\"dateModified\":\"2025-08-29T05:12:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/\"},\"wordCount\":941,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2025\\\/08\\\/Semi-APJ-4-Blog-Header_1920x450.png\",\"keywords\":[\"DualBeam\",\"Electronics\\\/Semiconductors\",\"Failure Analysis\",\"laser ablation\"],\"articleSection\":[\"DualBeam (FIB-SEM)\",\"General\",\"Semiconductor\",\"Transmission Electron Microscopy\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/\",\"url\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/\",\"name\":\"FIB-SEM - Sample Preparation - Illuminating Semiconductors\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2025\\\/08\\\/Semi-APJ-4-Blog-Header_1920x450.png\",\"datePublished\":\"2025-08-29T05:11:59+00:00\",\"dateModified\":\"2025-08-29T05:12:03+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/7dfc8535eee862bd1f8d905c8b6cb663\"},\"description\":\"Sample preparation challenges associated with large volume material removal and the characteristics needed in a FIB-SEM.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#primaryimage\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2025\\\/08\\\/Semi-APJ-4-Blog-Header_1920x450.png\",\"contentUrl\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/wp-content\\\/uploads\\\/sites\\\/23\\\/2025\\\/08\\\/Semi-APJ-4-Blog-Header_1920x450.png\",\"width\":1920,\"height\":450,\"caption\":\"Removing Large Volumes of Material Fast with FIB-SEMs\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.thermofisher.com\\\/blog\\\/semiconductors\\\/fib-sem-sample-preparation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Removing Large Volumes of Material Fast with FIB-SEMs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#website\",\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/\",\"name\":\"Illuminating Semiconductors\",\"description\":\"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/semiconductors\\\/#\\\/schema\\\/person\\\/7dfc8535eee862bd1f8d905c8b6cb663\",\"name\":\"David Akerson\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g\",\"caption\":\"David Akerson\"},\"url\":\"https:\\\/\\\/admin.acceleratingscience.com\\\/author\\\/davidakerson\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"FIB-SEM - Sample Preparation - Illuminating Semiconductors","description":"Sample preparation challenges associated with large volume material removal and the characteristics needed in a FIB-SEM.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/","og_locale":"en_US","og_type":"article","og_title":"Removing Large Volumes of Material Fast with FIB-SEMs","og_description":"Sample preparation challenges associated with large volume material removal and the characteristics needed in a FIB-SEM.","og_url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/","og_site_name":"Illuminating Semiconductors","article_publisher":"https:\/\/www.facebook.com\/thermofisher","article_published_time":"2025-08-29T05:11:59+00:00","article_modified_time":"2025-08-29T05:12:03+00:00","og_image":[{"width":1920,"height":450,"url":"http:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png","type":"image\/png"}],"author":"David Akerson","twitter_card":"summary_large_image","twitter_creator":"@thermofisher","twitter_site":"@thermofisher","twitter_misc":{"Written by":"David Akerson","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#article","isPartOf":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/"},"author":{"name":"David Akerson","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/7dfc8535eee862bd1f8d905c8b6cb663"},"headline":"Removing Large Volumes of Material Fast with FIB-SEMs","datePublished":"2025-08-29T05:11:59+00:00","dateModified":"2025-08-29T05:12:03+00:00","mainEntityOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/"},"wordCount":941,"commentCount":0,"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png","keywords":["DualBeam","Electronics\/Semiconductors","Failure Analysis","laser ablation"],"articleSection":["DualBeam (FIB-SEM)","General","Semiconductor","Transmission Electron Microscopy"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/","url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/","name":"FIB-SEM - Sample Preparation - Illuminating Semiconductors","isPartOf":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#primaryimage"},"image":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#primaryimage"},"thumbnailUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png","datePublished":"2025-08-29T05:11:59+00:00","dateModified":"2025-08-29T05:12:03+00:00","author":{"@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/7dfc8535eee862bd1f8d905c8b6cb663"},"description":"Sample preparation challenges associated with large volume material removal and the characteristics needed in a FIB-SEM.","breadcrumb":{"@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#primaryimage","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png","contentUrl":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png","width":1920,"height":450,"caption":"Removing Large Volumes of Material Fast with FIB-SEMs"},{"@type":"BreadcrumbList","@id":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-sample-preparation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/admin.acceleratingscience.com\/semiconductors\/"},{"@type":"ListItem","position":2,"name":"Removing Large Volumes of Material Fast with FIB-SEMs"}]},{"@type":"WebSite","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#website","url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/","name":"Illuminating Semiconductors","description":"Semiconductor manufacturing stories and solutions about a more connected, more autonomous, and smarter world","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/admin.acceleratingscience.com\/semiconductors\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/admin.acceleratingscience.com\/semiconductors\/#\/schema\/person\/7dfc8535eee862bd1f8d905c8b6cb663","name":"David Akerson","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/39d597a7fc85d84d2828cb36c1542420e027f9e79f81ac612d1291be2df9eedd?s=96&d=mm&r=g","caption":"David Akerson"},"url":"https:\/\/admin.acceleratingscience.com\/author\/davidakerson\/"}]}},"taxonomy_info":{"category":[{"value":17,"label":"DualBeam (FIB-SEM)"},{"value":25,"label":"General"},{"value":19,"label":"Semiconductor"},{"value":23,"label":"Transmission Electron Microscopy"}],"post_tag":[{"value":28,"label":"DualBeam"},{"value":16,"label":"Electronics\/Semiconductors"},{"value":69,"label":"Failure Analysis"},{"value":92,"label":"laser ablation"}]},"featured_image_src_large":["https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450-1024x240.png",760,178,true],"author_info":{"display_name":"David Akerson","author_link":"https:\/\/admin.acceleratingscience.com\/author\/davidakerson\/"},"comment_info":34,"category_info":[{"term_id":17,"name":"DualBeam (FIB-SEM)","slug":"dualbeam-fib-sem","term_group":0,"term_taxonomy_id":17,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":17,"category_count":14,"category_description":"","cat_name":"DualBeam (FIB-SEM)","category_nicename":"dualbeam-fib-sem","category_parent":0},{"term_id":25,"name":"General","slug":"general","term_group":0,"term_taxonomy_id":25,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":25,"category_count":14,"category_description":"","cat_name":"General","category_nicename":"general","category_parent":0},{"term_id":19,"name":"Semiconductor","slug":"semiconductor","term_group":0,"term_taxonomy_id":19,"taxonomy":"category","description":"","parent":0,"count":31,"filter":"raw","meta":[],"cat_ID":19,"category_count":31,"category_description":"","cat_name":"Semiconductor","category_nicename":"semiconductor","category_parent":0},{"term_id":23,"name":"Transmission Electron Microscopy","slug":"transmission-electron-microscopy","term_group":0,"term_taxonomy_id":23,"taxonomy":"category","description":"","parent":0,"count":14,"filter":"raw","meta":[],"cat_ID":23,"category_count":14,"category_description":"","cat_name":"Transmission Electron Microscopy","category_nicename":"transmission-electron-microscopy","category_parent":0}],"tag_info":[{"term_id":28,"name":"DualBeam","slug":"dualbeam","term_group":0,"term_taxonomy_id":28,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw","meta":[]},{"term_id":16,"name":"Electronics\/Semiconductors","slug":"electronics-semiconductors","term_group":0,"term_taxonomy_id":16,"taxonomy":"post_tag","description":"","parent":0,"count":25,"filter":"raw","meta":[]},{"term_id":69,"name":"Failure Analysis","slug":"failure-analysis","term_group":0,"term_taxonomy_id":69,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw","meta":[]},{"term_id":92,"name":"laser ablation","slug":"laser-ablation","term_group":0,"term_taxonomy_id":92,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw","meta":[]}],"jetpack-related-posts":[{"id":1079,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/supporting-advanced-packaging-with-integrated-semiconductor-failure-analysis-workflows\/","url_meta":{"origin":326,"position":0},"title":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows","author":"Vinay S","date":"October 22, 2026","format":false,"excerpt":"Key takeaways Semiconductor failure analysis of advanced packaging technologies requires the connection of electrical and physical evidence across multiple length scales to identify root cause. Non-destructive methods such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography can be used to localize defects for subsequent targeted investigation. Focused ion\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"Supporting Advanced Packaging with Integrated Semiconductor Failure Analysis Workflows.","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/10\/from-fault-localization-header-image-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1150,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/electron-microscopy-ai-semiconductor-manufacturing\/","url_meta":{"origin":326,"position":1},"title":"Where Electron Microscopy Fits in the AI Ecosystem","author":"Swarnim Rawat","date":"November 16, 2026","format":false,"excerpt":"Artificial intelligence is often discussed in terms of algorithms, models, and compute performance. Headlines focus on GPUs, large-scale training clusters, and new model capabilities. But beneath that visible layer lies a complex ecosystem, one that spans chip design, fabrication, packaging, and data storage. What ultimately determines the pace of AI\u2026","rel":"","context":"In &quot;DualBeam (FIB-SEM)&quot;","block_context":{"text":"DualBeam (FIB-SEM)","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/dualbeam-fib-sem\/"},"img":{"alt_text":"Abstract of an AI chip and crystal lattice","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/BLG-16771908_Blog-Mohan-POV-on-AI-Social-Preview-1200x630-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":1108,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/fib-sem-semiconductor-characterization\/","url_meta":{"origin":326,"position":2},"title":"From Manual Control to Automated Insights: Versatile FIB-SEM Workflows for Semiconductor Research","author":"Claudia Bernal","date":"November 11, 2026","format":false,"excerpt":"As semiconductor devices become increasingly complex and three-dimensional, researchers need more than one way to access and understand the structures hidden beneath the surface. Some investigations begin with hands-on FIB-SEM operation, where researchers need the freedom to explore an unfamiliar device, locate a region of interest, and optimize the preparation\u2026","rel":"","context":"In &quot;Focused Ion Beam&quot;","block_context":{"text":"Focused Ion Beam","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/focused-ion-beam\/"},"img":{"alt_text":"","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/fib-sem-semiconductor-characterization-header-1920x450-1.jpg?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1136,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/tem-sample-preparation-automation\/","url_meta":{"origin":326,"position":3},"title":"TEM Sample Preparation Automation: Matching the Level to the Workflow\u00a0","author":"Swarnim Rawat","date":"November 17, 2026","format":false,"excerpt":"In most labs, TEM sample capacity depends on the availability of experienced operators who can reliably navigate to the region of interest, perform lift-out, precisely execute thinning and endpointing, recover from interruptions, and train new users to do the same.\u00a0 Automation can reduce that constraint, but not every sample requires\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"Helios Family Blog","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=1050%2C600&ssl=1 3x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/11\/helios-family-blog-hero-1920x450-1.png?resize=1400%2C800&ssl=1 4x"},"classes":[]},{"id":1047,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/non-destructive-semiconductor-defect-detection-advanced-packaging-technology\/","url_meta":{"origin":326,"position":4},"title":"Non-Destructive Semiconductor Defect Detection\u00a0in\u00a0Advanced Packaging\u00a0Technology","author":"Swarnim Rawat","date":"July 1, 2026","format":false,"excerpt":"Key highlights Compared to conventional package designs, semiconductor defect detection\u00a0is\u00a0more difficult\u00a0for\u00a0advanced packaging\u00a0because failure sites are smaller,\u00a0more deeply embedded, and\u00a0are\u00a0distributed across more material interfaces\u00a0 Non-destructive techniques such as X-ray computed tomography, scanning acoustic microscopy, and lock-in thermography provide critical information on advanced\u00a0packages\u00a0that can\u00a0facilitate\u00a0higher-resolution analysis with destructive techniques\u00a0 A full workflow that\u2026","rel":"","context":"In &quot;Advanced Packaging&quot;","block_context":{"text":"Advanced Packaging","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/semiconductor\/advanced-packaging\/"},"img":{"alt_text":"Advanced packaging","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2026\/07\/advanced-packaging-social-1080x1080-1.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]},{"id":625,"url":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/dram-device-dram-fabrication-tem-metrology\/","url_meta":{"origin":326,"position":5},"title":"Enhancing High-Volume DRAM Manufacturing with Automated TEM Metrology and Characterization","author":"Xiaoting Gu","date":"November 6, 2025","format":false,"excerpt":"Dynamic random-access memory (DRAM) plays a crucial role in computing devices, providing fast access to essential data and allowing them to operate at peak performance. For DRAM device manufacturers, scaling is important as it enables lower cost per unit area by enabling reductions in DRAM cell size. However, as DRAM\u2026","rel":"","context":"In &quot;Failure Analysis&quot;","block_context":{"text":"Failure Analysis","link":"https:\/\/admin.acceleratingscience.com\/semiconductors\/failure-analysis\/"},"img":{"alt_text":"DRAM memory","src":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=350%2C200&ssl=1","width":350,"height":200,"srcset":"https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=350%2C200&ssl=1 1x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=525%2C300&ssl=1 1.5x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=700%2C400&ssl=1 2x, https:\/\/i0.wp.com\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2024\/04\/DRAM-TEM-Metrology-Blog-Social_1200x630.jpg?resize=1050%2C600&ssl=1 3x"},"classes":[]}],"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/admin.acceleratingscience.com\/semiconductors\/wp-content\/uploads\/sites\/23\/2025\/08\/Semi-APJ-4-Blog-Header_1920x450.png","_links":{"self":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/326","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/users\/1346"}],"replies":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/comments?post=326"}],"version-history":[{"count":0,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/posts\/326\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media\/847"}],"wp:attachment":[{"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/media?parent=326"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/categories?post=326"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/tags?post=326"},{"taxonomy":"division","embeddable":true,"href":"https:\/\/www.thermofisher.com\/blog\/semiconductors\/wp-json\/wp\/v2\/division?post=326"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}