Note, order lookup is only supported in the following countries: United States, Canada.
If you are outside one of those countries please reach out to One Lambda Customer Support to submit an order status inquiry.
Molecular Assessment of Rejection in Pediatric Heart Transplantation: A Complement to Histopathology
Watch this webinar to hear Drs. Magnetta and Arva discuss MMDx Heart, a tool that combines histopathology with molecular techniques to provide a more accurate diagnosis for organ transplant rejection.
PubSummary | The Molecular Microscope Diagnostic System (MMDx) Interpretation of Solid Organ Allograft Biopsies: Restoring the Perspective
MMDx Kidney helps refine the histopathologist’s findings that is not possible through light microscopy and support ABMR diagnosis where C4d or DSA results are either unavailable or negative.
The Value of MMDx in Diagnostic Uncertainty for Patients with Heart Transplantation: A Case-Based Presentation
In this presentation, Dr. Guha explores heart transplant patient cases in which clinical presentation and pathological diagnosis on biopsy are discrepant and gene expression profiling was used.
How Emerging Technologies Are Filling The Gaps And Positively Impacting Post-Transplant Care
Join Drs. Rajeev Sharma and Jamil Azzi to learn how new molecular solutions can provide clinical utility and enhance the patient experience. Valen Keefer provides a unique perspective to consider.
Novel Technology Has Made It Possible To Diagnose A New Clinical Phenotype Of Rejection Called Early Antibody Mediated Rejection, With Significant Therapeutic Implications For Renal Allograft Survival
Discover how MMDx Kidney can diagnose antibody-mediated rejection (AMBR) when histopathology is discordant with the clinical scenario. While there is still no FDA-approved treatment for ABMR. It is suggested that identifying early ABMR could lead to intervention and the prevention of graft loss due to chronic active ABMR.
US payer budget impact of a microarray assay with machine learning to evaluate kidney transplant rejection in for-cause biopsies
Dr. Chris Lawrence explores how a US payer budget model demonstrates that MMDx® Kidney is a cost-effective intervention despite the cost of the assay and the higher treatment costs associated with identifying more rejection.
Using Molecular Diagnostics for Kidney Transplants: Getting There! | Gaurav Gupta
Explore how molecular diagnostics can be used in clinical practice, including how the test can complement traditional histology as well as how the results can be incorporated into patient management.
Case Study | A Challenging Diagnosis in Kidney Transplantation: MMDx Kidney
In a case where a highly sensitized patient received abnormal biopsy results after transplantation, gene expression profiling provided the treating clinician with confirmatory results for diagnosis.
PubSummary | A 2020 Banff Antibody Mediated Injury Working Group examination of international practices for diagnosing antibody mediated rejection in kidney transplantation
Biopsy data is accompanied by DSA data in +/- 30% of cases, suggesting urgent action to improve the accessibility of DSA information is needed.
PubSummary | Revisiting the changes in the Banff Classification for antibody‐mediated rejection after kidney transplantation
In the search for potential treatments and personalized prognostication, a clear definition of antibody mediated rejection (ABMR) is an indispensable prerequisite.
Discovering novel injury features in kidney transplant biopsies associated with TCMR and donor aging
We previously characterized the molecular changes in acute kidney injury (AKI) and chronic kidney disease (CKD) in kidney transplant biopsies, but parenchymal changes selective for specific types ...
The Molecular Microscope Diagnostic System: Precision and Accuracy in Transplant Diagnostics | Philip Halloran
Dr. Phil Halloran discusses the unmet need for precision and accuracy in pathological biopsy assessment and reviews the applications of the actionable data generated in MMDx reports.
Please sign in to access your account. Customers must log in to access some content, recorded webinars, training materials, documents, and software.
Incorrect username or password
Need Help? Call website support Toll Free: +1 800 822 8824 option 2 or Email support team
Don’t have a profile?
Register Now
Registration
Please provide the following to setup your user account. If you do not know your center ID, please leave the center ID field blank.
This email may already be in use. Please reset your password or feel free to contact 1lambda-techsupport@thermofisher.com. Thank you.
Thank you for registering, please expect an email confirming your account registration status. For support please reach out to 1lambda-techsupport@thermofisher.com
Thank you for registering, please expect an email confirming your account registration status. For support please reach out to 1lambda-techsupport@thermofisher.com
Thank you for registering, please expect an email confirming your account registration status. For support please reach out to 1lambda-techsupport@thermofisher.com
Thank you for registering. Our team will verify your account and you will receive an email within 1-2 business days to confirm your registration status. For immediate support, please reach out to 1lambda-techsupport@thermofisher.com