Thermo Scientific™

Dionex™ ICS-Series VWD Variable Wavelength Detectors

Catalog number: 069116
Thermo Scientific™

Dionex™ ICS-Series VWD Variable Wavelength Detectors

Catalog number: 069116
Get outstanding sensitivity for routine ion chromatography applications with dual-lamp Thermo Scientific™ Dionex™ ICS-Series VWD Variable Wavelength Detectors in single- or four-channel wavelength configurations. Work free from worry of metal contamination with available all Thermo Scientific™ PEEK™ flow cells. You can get results from up to four different wavelengths simultaneously using the detector’s multiple wavelength monitoring capability.
 
Catalog Number
069116
Unit Size
Each
Detector Type
Variable Wavelength (VWD)
Price (USD)
Full specifications
TypeVariable Wavelength (VWD)
Detector TypeVariable Wavelength (VWD)
Data Collection RateUp to 10 Hz
Drift<0.1 mAU/hr
Noise Level< ±2.5 μAU (at 254 nm)
Flow Cell Volume11 μL
Flow Cell MaterialsPEEK
Wavelength Accuracy±1 nm
Wavelength Range190 to 900 nm
LampSimultaneous Tungsten and Deuterium
Flow CellPEEK, 11 μL volume, 10 mm path length (analytical); 2.5 μL, 7 mm path length (semimicro)
Linearityup to 2.5 AU
PC ConnectionUSB
Wavelength Bandwidth6 nm (at 254 nm)
Height (Metric)15.2 cm
Height (English)6.0 in.
Voltage85 to 265 VAC
Width (English)17.5 in.
Width (Metric)44.4 cm
Electrical Requirements85 to 265 VAC 47/63 Hz
DescriptionSingle wavelength
Frequency47/63 Hz
Analog OutputsTwo: absorbance, 20-bit resolution, 0-1 V and 0-10 V
Unit SizeEach
Catalog Number
Unit Size
Each
Detector Type
Variable Wavelength (VWD)
Price (USD)
Full specifications
TypeVariable Wavelength (VWD)
Detector TypeVariable Wavelength (VWD)
Data Collection RateUp to 100 Hz
Drift<0.1 mAU/hr
Noise Level< ±2.5 μAU (at 254 nm)
Flow Cell Volume11 μL
Flow Cell MaterialsPEEK
Wavelength Accuracy±1 nm
Wavelength Range190 to 900 nm
LampSimultaneous Tungsten and Deuterium
Flow CellPEEK, 11 μL volume, 10 mm path length (analytical); 2.5 μL, 7 mm path length (semimicro)
Linearityup to 2.5 AU
PC ConnectionUSB
Wavelength Bandwidth6 nm (at 254 nm)
Height (Metric)15.2 cm
Height (English)6.0 in.
Voltage85 to 265 VAC
Width (English)17.5 in.
Width (Metric)44.4 cm
Electrical Requirements85 to 265 VAC 47/63 Hz
DescriptionMultiple (4 channel) wavelength
Frequency47/63 Hz
Analog OutputsTwo: absorbance, 20-bit resolution, 0-1 V and 0-10 V
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeDetector TypePrice (USD)
069116Full specifications
EachVariable Wavelength (VWD)Request A Quote
TypeVariable Wavelength (VWD)
Detector TypeVariable Wavelength (VWD)
Data Collection RateUp to 10 Hz
Drift<0.1 mAU/hr
Noise Level< ±2.5 μAU (at 254 nm)
Flow Cell Volume11 μL
Flow Cell MaterialsPEEK
Wavelength Accuracy±1 nm
Wavelength Range190 to 900 nm
LampSimultaneous Tungsten and Deuterium
Flow CellPEEK, 11 μL volume, 10 mm path length (analytical); 2.5 μL, 7 mm path length (semimicro)
Linearityup to 2.5 AU
PC ConnectionUSB
Wavelength Bandwidth6 nm (at 254 nm)
Height (Metric)15.2 cm
Height (English)6.0 in.
Voltage85 to 265 VAC
Width (English)17.5 in.
Width (Metric)44.4 cm
Electrical Requirements85 to 265 VAC 47/63 Hz
DescriptionSingle wavelength
Frequency47/63 Hz
Analog OutputsTwo: absorbance, 20-bit resolution, 0-1 V and 0-10 V
Unit SizeEach
069117Full specifications
EachVariable Wavelength (VWD)Request A Quote
TypeVariable Wavelength (VWD)
Detector TypeVariable Wavelength (VWD)
Data Collection RateUp to 100 Hz
Drift<0.1 mAU/hr
Noise Level< ±2.5 μAU (at 254 nm)
Flow Cell Volume11 μL
Flow Cell MaterialsPEEK
Wavelength Accuracy±1 nm
Wavelength Range190 to 900 nm
LampSimultaneous Tungsten and Deuterium
Flow CellPEEK, 11 μL volume, 10 mm path length (analytical); 2.5 μL, 7 mm path length (semimicro)
Linearityup to 2.5 AU
PC ConnectionUSB
Wavelength Bandwidth6 nm (at 254 nm)
Height (Metric)15.2 cm
Height (English)6.0 in.
Voltage85 to 265 VAC
Width (English)17.5 in.
Width (Metric)44.4 cm
Electrical Requirements85 to 265 VAC 47/63 Hz
DescriptionMultiple (4 channel) wavelength
Frequency47/63 Hz
Analog OutputsTwo: absorbance, 20-bit resolution, 0-1 V and 0-10 V
Unit SizeEach
Showing 2 of 2
Economical High Performance for Routine Chromatography
  • Excellent sensitivity with low baseline drift and high signal-to-noise ratio
  • Low noise and high intensity over the full spectral range with deuterium and tungsten lamps
  • Thermal stability with low backpressure from the integrated flow cell heat exchanger
  • Easy verification of wavelength accuracy with built-in holmium oxide filter
  • Excellent resolution that yields high linearity
  • Lamp lifetime monitor to prevent downtime
  • Simple installation and data collection via USB
Flexible Applications
  • Data collection rates up to 100Hz
  • Broad wavelength range of 190–900nm
  • Powerful, user-friendly control and data collection through Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System software

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text