Dionex™ ICS-Series PDA Photodiode Array Detector
Dionex™ ICS-Series PDA Photodiode Array Detector
Thermo Scientific™

Dionex™ ICS-Series PDA Photodiode Array Detector

Maximize optical absorbance information with high-resolution, full UV-Vis spectra, highly flexible multiple wavelength signals and referencing capabilities.

Have Questions?
Catalog NumberWavelength Range
074114190 to 800 nm
Catalog number 074114
Price (USD)
-
Wavelength Range:
190 to 800 nm

Maximize optical absorbance information with the Thermo Scientific™ Dionex™ ICS-Series PDA Photodiode Array Detector. You will get excellent, high-resolution performance from its full UV-vis spectra, along with an ultraquiet optical bench. A variety of flow cells compatible with ion chromatography are available.

High-Performance UV-Vis Detection

  • Outstanding wavelength resolution from a 1024-element photodiode array
  • Broad wavelength range from 190 to 800 nm
  • Low noise and high intensity over the full spectral range from the deuterium and tungsten lamps
  • Simple installation and data collection via USB
  • Alternate data collection via four analog outputs
  • Excellent reliability and reproducibility with low baseline drift

Excellent Ease of Use

  • Easy verification of wavelength accuracy with built-in holmium oxide filter
  • Simplified routine maintenance with front access to prealigned cells and lamps
  • Convenient quick view of detector status on five front-panel LEDs
  • Powerful full control and data collection through Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System software
  • User-friendly software panels for operation in multiwavelength mode
  • Limited stand-alone operation without software control for simplified troubleshooting or temporary operation without a computer
Specifications
Analog OutputsFour: 0-3 Å, 1000 mV Range
Drift<500 μÅ/h
Flow Cell Max. Pressure<2 MPa (300 psi) PEEK
<3 MPa (500 psi) SST
Flow Cell Volume13 μL
For Use With (Application)Ion Chromatography
Height (Metric)17.4 cm
LampTungsten and deuterium
Length (Metric)50.3 cm
Linearity>2 Å
Noise Level±10 μÅ at 254 nm (flowing water, 2-s rise time)
±15 μÅ at 520 nm (flowing water, 2-s rise time)
Pixel Resolution0.7 nm
Wavelength Accuracy±1 nm, self-calibration with deuterium lines, verification with built-in holmium oxide filter
Wavelength Range190 to 800 nm
Width (Metric)44.4 cm
Detection ModeWavelength Resolution/UV-Visibility
Detector TypeUV-Visibility
Flow Cell MaterialsPEEK, Fused Silica, SST
For Use With (Equipment)Dionex Chromeleon Chromatography Data System Software
TypePhotodiode Array
Unit SizeEach