Gain rate information and totalization function accuracy of ±1% for processes involving non-critical or lower value materials with the Thermo Scientific™ Ramsey™ IDEA Belt Scale System. The belt scale system consists of three major elements: the weighing assembly measures the weight of material on the belt, the belt speed sensor and electronic integrator joins the output signals from the scale module and speed sensor to arrive at a rate of material flow and the total material passed over the scale.
 
Catalog Number
10121998
Unit Size
Each
Description
Ramsey IDEA Belt Scale System
Price (USD)
Full specifications
Analog InputsmV signal from load cell
Analog OutputsQuantity: 1, Type: 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA selectable, Maximum Load: 500 ohm, Resolution: 12 bit; 4,096 divisions, Linearity: 0.1%, Insulation: Galvanic; 1,500 Vrms
Cable6 conductor, shielded, 22 AWG
DescriptionRamsey IDEA Belt Scale System
Digital InputsQuantity: 3, Type: Static; For dry contact or open collector, Insulation: Optical; 2,500 Vrms; UL E67349, Voltage: 14 VDC internal source, Current: 6 mA
Digital OutputsQuantity: 4, Type: Relay; Dry contact; NO, Insulation: Galvanic; 10,000 M-ohm, Max. Voltage: 240 VAC or 48 VDC
Enclosure Size300 x 250 x 16 mm (H x W xD) (11.81 x 9.84 x 6.3 in.)
Enclosure MaterialPolyester
Enclosure ProtectionIP65; NEMA-4
Enclosure Weight4 kg (8.8 lb.)
Environmental ProtectionWeather-tight, epoxy finish, cast aluminum
Excitation10 VDC or VAC
HousingMax. Current: 0.5Å
Input Impendance380 ohm ±10
Load Cell ConstructionWelded bending beam-type load cell
Load CellsWelded bending beam-type load cell
Load Cell Rating3000 d; Meets OIML R60 & NIST HB-44
Load Cell Output2 mV/V ±0.1%
Load Cell Sizes20 kg (44 lb.); 50 kg (110 lb.); 100 kg (220 lb.); 200 kg (441 lb.); 250 kg (551 lb.); 500 kg (1102 lb.)
Max. Gross Load at Rated Capacity80% of load cell capacity
Min. Net Load at Rated Capacity15% of load cell capacity
MountingDirect to 15.88 mm (0.625 in.) diameter stub shaft on tail pulley, bend pulley or return roll
Mounting HardwareSupplied with coupling, restraint arm and restraint spring
Operating Temperature-10°C to +50°C (14°F to 122°F)
Output Impendance350 ohm ±3
Overall Humidity<90%
Overload150% of rated capacity
ProtectionIP65; NEMA-4; Internal fuse
Shipping Weight8 lb.
Storage Temperature-20°C to +70°C (-4°F to +158°F)
Temperature Range-10°C to +50°C (14°F to 122°F)
Voltage110 or 220 VAC selectable standard; +10%-15; at 50-60 Hz; 15 VA
Width (Metric) Belt10-101R-1: 914 mm (36 in.); 10-101R-2: 1,524 mm (60 in.)
TypeDigital, brushless, belt scale
Communication PortsRS 232C for printer
Display TypeDigital
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
10121998Full specifications
EachRamsey IDEA Belt Scale SystemRequest A Quote
Analog InputsmV signal from load cell
Analog OutputsQuantity: 1, Type: 0-20 mA, 4-20 mA, 20-0 mA, 20-4 mA selectable, Maximum Load: 500 ohm, Resolution: 12 bit; 4,096 divisions, Linearity: 0.1%, Insulation: Galvanic; 1,500 Vrms
Cable6 conductor, shielded, 22 AWG
DescriptionRamsey IDEA Belt Scale System
Digital InputsQuantity: 3, Type: Static; For dry contact or open collector, Insulation: Optical; 2,500 Vrms; UL E67349, Voltage: 14 VDC internal source, Current: 6 mA
Digital OutputsQuantity: 4, Type: Relay; Dry contact; NO, Insulation: Galvanic; 10,000 M-ohm, Max. Voltage: 240 VAC or 48 VDC
Enclosure Size300 x 250 x 16 mm (H x W xD) (11.81 x 9.84 x 6.3 in.)
Enclosure MaterialPolyester
Enclosure ProtectionIP65; NEMA-4
Enclosure Weight4 kg (8.8 lb.)
Environmental ProtectionWeather-tight, epoxy finish, cast aluminum
Excitation10 VDC or VAC
HousingMax. Current: 0.5Å
Input Impendance380 ohm ±10
Load Cell ConstructionWelded bending beam-type load cell
Load CellsWelded bending beam-type load cell
Load Cell Rating3000 d; Meets OIML R60 & NIST HB-44
Load Cell Output2 mV/V ±0.1%
Load Cell Sizes20 kg (44 lb.); 50 kg (110 lb.); 100 kg (220 lb.); 200 kg (441 lb.); 250 kg (551 lb.); 500 kg (1102 lb.)
Max. Gross Load at Rated Capacity80% of load cell capacity
Min. Net Load at Rated Capacity15% of load cell capacity
MountingDirect to 15.88 mm (0.625 in.) diameter stub shaft on tail pulley, bend pulley or return roll
Mounting HardwareSupplied with coupling, restraint arm and restraint spring
Operating Temperature-10°C to +50°C (14°F to 122°F)
Output Impendance350 ohm ±3
Overall Humidity<90%
Overload150% of rated capacity
ProtectionIP65; NEMA-4; Internal fuse
Shipping Weight8 lb.
Storage Temperature-20°C to +70°C (-4°F to +158°F)
Temperature Range-10°C to +50°C (14°F to 122°F)
Voltage110 or 220 VAC selectable standard; +10%-15; at 50-60 Hz; 15 VA
Width (Metric) Belt10-101R-1: 914 mm (36 in.); 10-101R-2: 1,524 mm (60 in.)
TypeDigital, brushless, belt scale
Communication PortsRS 232C for printer
Display TypeDigital
Unit SizeEach
Showing 1 of 1
The Ramsey IDEA Belt Scale System Features:
  • Factory-installed and calibrated overload protection
  • Pivotless design with no linkages to introduce errors
  • No moving or wearing parts to cause potential maintenance problems
  • Compact design for easy installation and alignment
  • No place for material to build up and cause measurement errors
  • Identical interchangeable scale modules fit any belt width