Thermo Scientific™

1300 Series Class II, Type B2 Biological Safety Cabinet, 4 ft.., 115V

Catalog number: 1310TS1
Thermo Scientific™

1300 Series Class II, Type B2 Biological Safety Cabinet, 4 ft.., 115V

Catalog number: 1310TS1
Protect workers and samples during work with gases and volatile chemicals. Thermo Scientific™ 1300 Series Class II, Type B2 Biological Safety Cabinets are designed to meet the stringent safety requirements of working with toxic chemicals and trace amounts of radionuclides required in microbiological studies.
 
Catalog Number
1310TS1
also known as 1310
Unit Size
Each
Price (JPY)
Availability
***
Full specifications
Certifications/ComplianceNSF/ANSI 49, ETL, ETL, CE
Energy Consumption (Operating Set Point)0.28 kw
Model1300 Series
Noise Level65dBA
Outlets2 duplex, US
Ports2 on each side
Power Consumption0.28kW
ReceptaclesTwo Duplex, GFI
Sash Opening21.75 in. (Max), 8 in.
Sash Opening (Metric)203.2 mm (Max), 8 mm
TypeB2
Volume (Metric) Exhaust1130m³/hr.
Filter Efficiency99.99% at 0.3µm
Filter TypeHEPA
Item Description48 in.; 2 duplex, US
LightingNot included
Sash Opening (English)8 in. (21.75 in. max)
Worksurface Area854 sq. in. (0.55m²)
Width (English) Exterior54.3 in.
Width (English) Interior48 in.
Width (Metric) Exterior1379 mm
Width (Metric) Interior123.2cm
Height (English)25.7 in. to 29.2 in. (Interior), 71.5 in. (Exterior)
Height (Metric)1816 mm (Exterior), 653 mm to 742 mm (Interior)
Height (English) Interior653 to 742cm
Depth (Metric) Interior65.8cm
Net Weight (Metric)247kg
Electrical Requirements115V 50/60Hz
Voltage115V
Hertz50/60Hz
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizePrice (JPY)Availability
1310TS1
also known as 1310
Full specifications
EachRequest A Quote***
Certifications/ComplianceNSF/ANSI 49, ETL, ETL, CE
Energy Consumption (Operating Set Point)0.28 kw
Model1300 Series
Noise Level65dBA
Outlets2 duplex, US
Ports2 on each side
Power Consumption0.28kW
ReceptaclesTwo Duplex, GFI
Sash Opening21.75 in. (Max), 8 in.
Sash Opening (Metric)203.2 mm (Max), 8 mm
TypeB2
Volume (Metric) Exhaust1130m³/hr.
Filter Efficiency99.99% at 0.3µm
Filter TypeHEPA
Item Description48 in.; 2 duplex, US
LightingNot included
Sash Opening (English)8 in. (21.75 in. max)
Worksurface Area854 sq. in. (0.55m²)
Width (English) Exterior54.3 in.
Width (English) Interior48 in.
Width (Metric) Exterior1379 mm
Width (Metric) Interior123.2cm
Height (English)25.7 in. to 29.2 in. (Interior), 71.5 in. (Exterior)
Height (Metric)1816 mm (Exterior), 653 mm to 742 mm (Interior)
Height (English) Interior653 to 742cm
Depth (Metric) Interior65.8cm
Net Weight (Metric)247kg
Electrical Requirements115V 50/60Hz
Voltage115V
Hertz50/60Hz
Unit SizeEach
Showing 1 of 1

Features:

  • Contaminated air from the external environment is “totally exhausted,” eliminating the risk of sample or user exposure to harmful chemicals.
  • Auto compensation allows the safe use of optional inflow air prefilters.
  • Timed UV light option reduces risk of sample contamination and lowers bulb replacement costs.
  • 10° sloped window for ergonomic posture reduces strain and fatigue associated with long working hours.
  • Convenient display shows when the cabinet is operating safely and when it may require service.

Certifications:

  • NSF/ANSI™ 49, ETL, CE

Ordering Information:

Available in North America and Asia Pacific only. Canopy exhaust connections available separately.

Requires:

Exhaust system capable of drawing 665cfm for the 4′ wide unit and 998cfm for the 6′ wide unit against a negative static pressure of 1.5″ w.g. when the exhaust HEPA filter is new, and 2″. w.g. when loaded prior to replacement. Exhaust flow must be adjustable to allow for variation over the life of the exhaust HEPA filter.