Thermo Scientific™

Sarasota Gas Density Meters--FD900, ID900 and PD900

Catalog number: 14195
Thermo Scientific™

Sarasota Gas Density Meters--FD900, ID900 and PD900

Catalog number: 14195
Reliably measure density or density related variables in the oil and gas, petrochemical and power industries with Thermo Scientific™ Sarasota Gas Density Meters. These meters offer near real-time control signal availability and ensure plant efficiency and vitality.
 
Catalog Number
14195
Unit Size
Each
Description
Gas Density Meters
Price (USD)
Full specifications
ATEX ConformanceIntrinsically Safe, F option (frequency output): Ex II 1 G EEx ia IIC T6 (-20 °C ≤ Ta ≤+ 60°C), (94/9/EC), H option (headmounted electronics): Ex II 1 G EEx ia IIC T4 (-20°C≤ Ta ≤+ 60°C)
BS EN ISO 15156 / NACE MR0175 ConformanceAvailable as Option
Canadian Standards AssociationExplosion-proof, Class I, Div 1, Groups B, C and D
CE markCompliant;
Certifications/ComplianceCE Marked; ISO 9001:2000
ConnectionsScrew Terminals; Cable Entry: 2 x 0.75 in. NPT
DescriptionGas Density Meters
Electromagnetic CompatibilityCompliant (EN 61326:1997)
Electronics Housing MaterialCopper free aluminum grey epoxy finish; Plate glass window for local display option
Environmental RatingIP65 (NEMA 4X)
Flow RangeSarasota FD900/Sarasota PD900: ideally 4L/min.
Height (English) ShippingSarasota FD900: approx. 14 in.; Sarasota ID900/fixed flange: approx. 14 in.; Sarasota ID900/1 m stem: approx. 9 in.; Sarasota PD900: approx. 15 in.
Height (Metric) ShippingSarasota FD900: approx. 360 mm; Sarasota ID900/fixed flange: approx. 360 mm; Sarasota ID900/1 m stem: approx. 230 mm; Sarasota PD900: approx. 390 mm
Installation PositionIdeally within 15° of vertical, for other orientations consult Thermo Fisher
Length (English) ShippingSarasota FD900: approx. 24 in. ; Sarasota ID900/fixed flange: approx. 24 in.; Sarasota ID900/1 m stem: approx. 52 in.; Sarasota PD900: approx. 29 in.
Length (Metric) ShippingSarasota FD900: approx. 610 mm; Sarasota ID900/fixed flange: approx. 610 mm; Sarasota ID900/1 m stem: approx. 1320 mm; Sarasota PD900: approx. 740 mm
Local Display4.5 Digit 0.3 in. (7.6 mm) 7-Segment LCD Display; Resolution 0.1% or 0.01% Depending on Display Variable
Low Voltage DirectiveCompliant
Material TraceabilityWetted parts traceability to BS EN 10204.3.1.b; Certification available
Max. Operating PressureSarasota FD900: 170 bar (2465 psi) or Flange Rating; Sarasota ID900: 150 bar (2175 psi) or Flange Rating; Sarasota PD900: Standard Stainless Steel Pocket: 100 bar (1450 psi); Standard Carbon Steel Pocket: 150 bar (2175 psi); Quick Response Stainless Steel Pocket: 50 bar (725 psi); Quick Response Carbon Steel Pocket: 50 bar (725 psi)
Non-Wetted Parts MaterialStainless Steel (316L/1.4404)
Operating Density RangeSarasota FD900/Sarasota ID900: 0 lb./ cu. ft to 62.4 lb./ cu. ft (0kg/cu. m to 1000kg/cu. m); Sarasota PD900: 0 lb./ cu. ft to 15.6 lb./ cu. ft in. (0kg/cu. m to 250kg/cu. m)
Operating Temperature Range-20°C to +60°C (-4°F to +140°F) ambient
Other Wetted Parts MaterialStainless Steel (316L/1.4404)
OutputsF option (frequency output): frequency related to density on 2-wire current modulated loop 6mA to 18mA; 4-wire PT100; H option (headmounted electronics): analog 4 to 20mA related to density or density derived variable; HART protocol
Pocket MaterialStandard pocket: carbon steel ASTM A350 LF2 or stainless steel 316L/1.4404; Quick response pocket: carbon steel ASTM A350 LF2 or stainless steel 316L/1.4404
Power SupplyF Option (Frequency Output): 13 to 28 VDC 10 mA Average (Peak 18 mA); H Option (Headmounted Electronics): 2 x 13 to 28 VDC 25 mA
Pressure Equipment DirectiveSEP (sound engineering practice)
Process Temperature-200°C to +200°C (-328°F to +392°F)
Quality AssuranceISO 9001:2000
Repeatability±0.01% Span
Safe Area UseAs Standard
Spool MaterialNi-Span C or FV520B
Temperature Effect0.001kg/cu. m/°C (0.000035 lb./ cu. ft/°F) note: correction coefficients applied (brackets with NiSpan C sensor)
Temperature MeasurementHigh Accuracy 1/3 DIN Integral 4-wire PT100
Transducer Calibration Accuracy0.125 lb./ cu. ft and above: ±0.1% reading; Below 0.125 lb./ cu. ft: ±0.000125 lb./ cu. Ft
Weight (English) ShippingSarasota FD900/flanged: typically 15 lb. ; Sarasota ID900/fixed flange: typically 33 lb.; Sarasota ID900/1 m stem: typically 18 lb.; Sarasota PD900: typically 19 lb.
Weight (Metric) ShippingSarasota FD900/flanged: typically 7 kg; Sarasota ID900/fixed flange: typically 15 kg; Sarasota ID900/1 m stem: typically 8 kg; Sarasota PD900: typically 8.5 kg
Width (English) ShippingSarasota FD900: approx. 14 in.; Sarasota ID900/fixed flange: approx. 14 in.; Sarasota ID900/1 m stem: approx. 9 in.; Sarasota PD900: approx. 13 in.
Width (Metric) ShippingSarasota FD900: approx. 360 mm; Sarasota ID900/fixed flange: approx . 360 mm; Sarasota ID900/1 m stem: approx. 230 mm; Sarasota PD900: approx. 320 mm
Item DescriptionSarasota gas density meters
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
14195Full specifications
EachGas Density MetersRequest A Quote
ATEX ConformanceIntrinsically Safe, F option (frequency output): Ex II 1 G EEx ia IIC T6 (-20 °C ≤ Ta ≤+ 60°C), (94/9/EC), H option (headmounted electronics): Ex II 1 G EEx ia IIC T4 (-20°C≤ Ta ≤+ 60°C)
BS EN ISO 15156 / NACE MR0175 ConformanceAvailable as Option
Canadian Standards AssociationExplosion-proof, Class I, Div 1, Groups B, C and D
CE markCompliant;
Certifications/ComplianceCE Marked; ISO 9001:2000
ConnectionsScrew Terminals; Cable Entry: 2 x 0.75 in. NPT
DescriptionGas Density Meters
Electromagnetic CompatibilityCompliant (EN 61326:1997)
Electronics Housing MaterialCopper free aluminum grey epoxy finish; Plate glass window for local display option
Environmental RatingIP65 (NEMA 4X)
Flow RangeSarasota FD900/Sarasota PD900: ideally 4L/min.
Height (English) ShippingSarasota FD900: approx. 14 in.; Sarasota ID900/fixed flange: approx. 14 in.; Sarasota ID900/1 m stem: approx. 9 in.; Sarasota PD900: approx. 15 in.
Height (Metric) ShippingSarasota FD900: approx. 360 mm; Sarasota ID900/fixed flange: approx. 360 mm; Sarasota ID900/1 m stem: approx. 230 mm; Sarasota PD900: approx. 390 mm
Installation PositionIdeally within 15° of vertical, for other orientations consult Thermo Fisher
Length (English) ShippingSarasota FD900: approx. 24 in. ; Sarasota ID900/fixed flange: approx. 24 in.; Sarasota ID900/1 m stem: approx. 52 in.; Sarasota PD900: approx. 29 in.
Length (Metric) ShippingSarasota FD900: approx. 610 mm; Sarasota ID900/fixed flange: approx. 610 mm; Sarasota ID900/1 m stem: approx. 1320 mm; Sarasota PD900: approx. 740 mm
Local Display4.5 Digit 0.3 in. (7.6 mm) 7-Segment LCD Display; Resolution 0.1% or 0.01% Depending on Display Variable
Low Voltage DirectiveCompliant
Material TraceabilityWetted parts traceability to BS EN 10204.3.1.b; Certification available
Max. Operating PressureSarasota FD900: 170 bar (2465 psi) or Flange Rating; Sarasota ID900: 150 bar (2175 psi) or Flange Rating; Sarasota PD900: Standard Stainless Steel Pocket: 100 bar (1450 psi); Standard Carbon Steel Pocket: 150 bar (2175 psi); Quick Response Stainless Steel Pocket: 50 bar (725 psi); Quick Response Carbon Steel Pocket: 50 bar (725 psi)
Non-Wetted Parts MaterialStainless Steel (316L/1.4404)
Operating Density RangeSarasota FD900/Sarasota ID900: 0 lb./ cu. ft to 62.4 lb./ cu. ft (0kg/cu. m to 1000kg/cu. m); Sarasota PD900: 0 lb./ cu. ft to 15.6 lb./ cu. ft in. (0kg/cu. m to 250kg/cu. m)
Operating Temperature Range-20°C to +60°C (-4°F to +140°F) ambient
Other Wetted Parts MaterialStainless Steel (316L/1.4404)
OutputsF option (frequency output): frequency related to density on 2-wire current modulated loop 6mA to 18mA; 4-wire PT100; H option (headmounted electronics): analog 4 to 20mA related to density or density derived variable; HART protocol
Pocket MaterialStandard pocket: carbon steel ASTM A350 LF2 or stainless steel 316L/1.4404; Quick response pocket: carbon steel ASTM A350 LF2 or stainless steel 316L/1.4404
Power SupplyF Option (Frequency Output): 13 to 28 VDC 10 mA Average (Peak 18 mA); H Option (Headmounted Electronics): 2 x 13 to 28 VDC 25 mA
Pressure Equipment DirectiveSEP (sound engineering practice)
Process Temperature-200°C to +200°C (-328°F to +392°F)
Quality AssuranceISO 9001:2000
Repeatability±0.01% Span
Safe Area UseAs Standard
Spool MaterialNi-Span C or FV520B
Temperature Effect0.001kg/cu. m/°C (0.000035 lb./ cu. ft/°F) note: correction coefficients applied (brackets with NiSpan C sensor)
Temperature MeasurementHigh Accuracy 1/3 DIN Integral 4-wire PT100
Transducer Calibration Accuracy0.125 lb./ cu. ft and above: ±0.1% reading; Below 0.125 lb./ cu. ft: ±0.000125 lb./ cu. Ft
Weight (English) ShippingSarasota FD900/flanged: typically 15 lb. ; Sarasota ID900/fixed flange: typically 33 lb.; Sarasota ID900/1 m stem: typically 18 lb.; Sarasota PD900: typically 19 lb.
Weight (Metric) ShippingSarasota FD900/flanged: typically 7 kg; Sarasota ID900/fixed flange: typically 15 kg; Sarasota ID900/1 m stem: typically 8 kg; Sarasota PD900: typically 8.5 kg
Width (English) ShippingSarasota FD900: approx. 14 in.; Sarasota ID900/fixed flange: approx. 14 in.; Sarasota ID900/1 m stem: approx. 9 in.; Sarasota PD900: approx. 13 in.
Width (Metric) ShippingSarasota FD900: approx. 360 mm; Sarasota ID900/fixed flange: approx . 360 mm; Sarasota ID900/1 m stem: approx. 230 mm; Sarasota PD900: approx. 320 mm
Item DescriptionSarasota gas density meters
Unit SizeEach
Showing 1 of 1
Features:
  • Continuous, online density monitoring
  • Measurement at true process conditions
  • Insertion, sample by-pass and pocket options
  • Compact design
  • Hazardous area approvals
  • Converter electronics to suit application

Sarasota FD900 Density Meter:

  • Provides high accuracy density and density related measurement of gases, liquefied gases and low viscosity fluids
  • Can be installed via sample by-pass or direct in-line
  • Is ideal for analyzer applications

Sarasota ID900 Insertion Density Meter:

  • Gives accurate, continuous density measurement of liquefied gases and low viscosity fluids in true process conditions with direct insertion into the pipeline or vessel by a choice of methods
  • Is ideal for process quality and control

Sarasota PD900 Pocket By-Pass Density Meter:

  • Provides high accuracy measurement of gases specifically
  • Provides continuous on-line density measurement at process conditions by directly mounting the thermowell into the pipeline

Recommended for:

  • Fiscal/custody transfer gas metering
  • Ethane cracking and ethylene production
  • Energy management systems
  • Stack emissions analysis and control
  • LNG metering and control
  • Calorific value estimation
  • Specific gravity measurement

Figures