Thermo Scientific™

SAHARA S21 Stainless-Steel Heated Bath Circulators

Catalog number: 156-1211
Thermo Scientific™

SAHARA S21 Stainless-Steel Heated Bath Circulators

Catalog number: 156-1211

Perfect for internal or external circulation. Thermo Scientific™ SAHARA S21 stainless-steel baths are offered in a wide selection for efficient heating from ambient 13° to 200°C, with maximum bath volume of 19 liters. The SAHARA series of heated bath circulators are available with a wide variety of work area dimensions to meet your internal or external circulation requirements. A selection of eight different controllers will create the perfect fit for your application. Rugged and corrosion-resistant for high temperature applications up to 300°C.

 
Catalog Number
156-1211
Unit Size
Each
Controller Type
AC200
Temperature Range
Ambient +13° to 200°C
Voltage
230 V
Frequency
50 Hz
Price (USD)
Full specifications
Controller TypeAC200
DescriptionAC200-S21; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Condenser TypeWater-cooled
Flow Rate20 L/min.
Temperature RangeAmbient +13° to 200°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
SC100
Temperature Range
Ambient +13° to 100°C
Voltage
230 V
Frequency
50 Hz
Price (USD)
Full specifications
Controller TypeSC100
DescriptionSC100-S21; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 100°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
SC100
Temperature Range
Ambient +13° to 100°C
Voltage
100 V
Frequency
50/60 Hz
Price (USD)
Full specifications
Controller TypeSC100
DescriptionSC100-S21 heating circulator; Ambient +13 to 100°C; 100V/50-60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Condenser TypeWater-cooled
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 100°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements100 V 50/60 Hz
Voltage100 V
Frequency50/60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
SC100
Temperature Range
Ambient +13° to 100°C
Voltage
115 V
Frequency
60 Hz
Price (USD)
Full specifications
Controller TypeSC100
DescriptionSC100-S21 heating circulator; Ambient +13 to 100°C; 115V/60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 100°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
SC150
Temperature Range
Ambient +13° to 150°C
Voltage
230 V
Frequency
50 Hz
Price (USD)
Full specifications
Controller TypeSC150
DescriptionSC150-S21; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
CommunicationsRS232, RS485, Ethernet/LAN, Analog I/O
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
SC150
Temperature Range
Ambient +13° to 150°C
Voltage
100 V
Frequency
50/60 Hz
Price (USD)
Full specifications
Controller TypeSC150
DescriptionSC150-S21 heating circulator; Ambient +13 to 150°C; 100V/50-60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
CommunicationsRS232, RS485, Ethernet/LAN, Analog I/O
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements100 V 50/60 Hz
Voltage100 V
Frequency50/60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
SC150
Temperature Range
Ambient +13° to 150°C
Voltage
115 V
Frequency
60 Hz
Price (USD)
Full specifications
Controller TypeSC150
DescriptionSC150-S21 heating circulator; Ambient +13 to 150°C; 115V/60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
CommunicationsRS232, RS485, Ethernet/LAN, Analog I/O
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
AC150
Temperature Range
Ambient +13° to 150°C
Voltage
230 V
Frequency
50 Hz
Price (USD)
Full specifications
Controller TypeAC150
DescriptionAC150-S21 heating circulator; Ambient +13 to 150°C; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate20 L/min.
Pump TypeForce Pump, Suction Pump
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
AC150
Temperature Range
Ambient +13° to 150°C
Voltage
100 V
Frequency
50/60 Hz
Price (USD)
Full specifications
Controller TypeAC150
DescriptionAC150-S21 heating circulator; Ambient +13 to 150°C; 100V/50-60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate20 L/min.
Pump TypeForce Pump, Suction Pump
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements100 V 50/60 Hz
Voltage100 V
Frequency50/60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Controller Type
AC150
Temperature Range
Ambient +13° to 150°C
Voltage
115 V
Frequency
60 Hz
Price (USD)
Full specifications
Controller TypeAC150
DescriptionAC150-S21 heating circulator; Ambient +13 to 150°C; 115V/60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate20 L/min.
Pump TypeForce Pump, Suction Pump
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Showing 10 of 12Show more
Catalog NumberSpecificationsUnit SizeController TypeTemperature RangeVoltageFrequencyPrice (USD)
156-1211Full specifications
EachAC200Ambient +13° to 200°C230 V50 HzRequest A Quote
Controller TypeAC200
DescriptionAC200-S21; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Condenser TypeWater-cooled
Flow Rate20 L/min.
Temperature RangeAmbient +13° to 200°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
152-1211Full specifications
EachSC100Ambient +13° to 100°C230 V50 HzRequest A Quote
Controller TypeSC100
DescriptionSC100-S21; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 100°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
152-1216Full specifications
EachSC100Ambient +13° to 100°C100 V50/60 HzRequest A Quote
Controller TypeSC100
DescriptionSC100-S21 heating circulator; Ambient +13 to 100°C; 100V/50-60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Condenser TypeWater-cooled
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 100°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements100 V 50/60 Hz
Voltage100 V
Frequency50/60 Hz
Unit SizeEach
152-1218Full specifications
EachSC100Ambient +13° to 100°C115 V60 HzRequest A Quote
Controller TypeSC100
DescriptionSC100-S21 heating circulator; Ambient +13 to 100°C; 115V/60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 100°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
153-1211Full specifications
EachSC150Ambient +13° to 150°C230 V50 HzRequest A Quote
Controller TypeSC150
DescriptionSC150-S21; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
CommunicationsRS232, RS485, Ethernet/LAN, Analog I/O
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
153-1216Full specifications
EachSC150Ambient +13° to 150°C100 V50/60 HzRequest A Quote
Controller TypeSC150
DescriptionSC150-S21 heating circulator; Ambient +13 to 150°C; 100V/50-60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
CommunicationsRS232, RS485, Ethernet/LAN, Analog I/O
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements100 V 50/60 Hz
Voltage100 V
Frequency50/60 Hz
Unit SizeEach
153-1218Full specifications
EachSC150Ambient +13° to 150°C115 V60 HzRequest A Quote
Controller TypeSC150
DescriptionSC150-S21 heating circulator; Ambient +13 to 150°C; 115V/60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
CommunicationsRS232, RS485, Ethernet/LAN, Analog I/O
Flow Rate17 L/min.
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
155-1211Full specifications
EachAC150Ambient +13° to 150°C230 V50 HzRequest A Quote
Controller TypeAC150
DescriptionAC150-S21 heating circulator; Ambient +13 to 150°C; 230V/50Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate20 L/min.
Pump TypeForce Pump, Suction Pump
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements230 V 50 Hz
Voltage230 V
Frequency50 Hz
Unit SizeEach
155-1216Full specifications
EachAC150Ambient +13° to 150°C100 V50/60 HzRequest A Quote
Controller TypeAC150
DescriptionAC150-S21 heating circulator; Ambient +13 to 150°C; 100V/50-60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate20 L/min.
Pump TypeForce Pump, Suction Pump
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements100 V 50/60 Hz
Voltage100 V
Frequency50/60 Hz
Unit SizeEach
155-1218Full specifications
EachAC150Ambient +13° to 150°C115 V60 HzRequest A Quote
Controller TypeAC150
DescriptionAC150-S21 heating circulator; Ambient +13 to 150°C; 115V/60Hz; 19L
Capacity (Metric)19 L
Certifications/ComplianceCE/ROHS/WEEE
Flow Rate20 L/min.
Pump TypeForce Pump, Suction Pump
Temperature RangeAmbient +13° to 150°C
Dimensions (L x W x H)24.7 x 15 x 16.1 in. (62.8 x 38.1 x 40.9 cm)
Length (English)24.7 in.
Length (Metric)62.8 cm
Width (English)15 in.
Width (Metric)38.1 cm
Height (English)16.1 in.
Height (Metric)40.9 cm
Weight (English)31.2 lb.
Weight (Metric)14.2 kg
Electrical Requirements115 V 60 Hz
Voltage115 V
Frequency60 Hz
Unit SizeEach
Showing 10 of 12Show more

Environmentally Friendly Design

  • Save up to 80% on energy costs and thousands of kilowatt hours during the life of the system
  • Lead- and mercury-free
  • All units are RoHS-compliant (lead- and mercury-free) and use recycled packaging

Safe Operation

  • All units are UL/CSA compliant, assuring safe operation in the unlikely event of a fault condition

Easy to Use

  • All thermostats feature an intuitive user interface with bright display to view critical readings
  • Thermostat can be turned and positioned on all four sides on the bath for easy viewing
  • Each system comes with a quick-start guide for simple setup and operation

Note:

  • 115/60 Hz units are UL listed or recognized
  • IQ/OQ compliance is optional

Includes:

Communication cables, bridge with gasket and thumbscrews, fittings, clamps, pump plug for external circulation, 6ft. power cord

Recommended for:

  • Viscometers
  • Spectrophotometers
  • Refractometers
  • Metrology
  • Warranty varies by country, please contact us for details

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text