Thermo Scientific™

Orion™ 1816DO Low-Level Dissolved Oxygen Analyzer

Catalog number: 1816D0
Thermo Scientific™

Orion™ 1816DO Low-Level Dissolved Oxygen Analyzer

Catalog number: 1816D0
Continuously monitor oxygen across a wide variety of low and trace level ppb level applications with the Thermo Scientific™ Orion™ 1816DO Low-Level Dissolved Oxygen Analyzer. Offering highly accurate measurement performance with proven reliability, the 1816DO analyzer provides effective process control you can trust.
 
Catalog Number
1816D0
Unit Size
Each
Description
1816 Trace DO Monitor
Price (USD)
Full specifications
Description1816 Trace DO Monitor
Frequency50/60 Hz
Outputs4 to 20mA or 0 to 20mA, 0 to 5V or 1 to 5VDC, Bi-directional RS232
Voltage115/230 VAC
Temperature (Metric) Operating2°C to 45°C
TypeDissolved Oxygen Analyzer
Accuracy0.1ppb ±2%, whichever is greater
Response Time1 min.
Width (English)10.24 in.
Width (Metric)26 cm
Weight (English)10.8 lb.
Weight (Metric)4.9 kg
CalibrationAutomatic in water saturated air
Regulatory DetailsNEMA 4X/IP65
Relay Details2
Calibration Range0-10ppm oxygen in water saturated air
Measurement Ranges0.1 to 300ppb (dissolved oxygen)
Sample Flow Rate50 to 200mL/min.
Sample Pressure<4 bar (60psi)
Wattage50w
Electrical Requirements115/230VAC 50/60Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
1816 Trace DO Monitor Without Sensor
Price (USD)
Full specifications
Accuracy0.1ppb ±2%, whichever is greater
CalibrationAutomatic in water saturated air
Calibration Range0-10ppm oxygen in water saturated air
Description1816 Trace DO Monitor Without Sensor
Temperature (Metric) Operating2°C to 45°C
TypeDissolved Oxygen Analyzer
Measurement Ranges0.1 to 300ppb (dissolved oxygen)
Outputs4 to 20mA or 0 to 20mA, 0 to 5V or 1 to 5VDC, Bi-directional RS232
Regulatory DetailsNEMA 4X/IP65
Relay Details2
Response Time1 min.
Sample Flow Rate50 to 200
Sample Pressure<4 bar (60psi)
Width (English)10.24 in.
Width (Metric)26 cm
Weight (English)10.8 lb.
Weight (Metric)4.9 kg
Electrical Requirements115/230VAC 50/60Hz
Voltage115/230 VAC
Wattage50w
Frequency50/60 Hz
Unit SizeEach
Catalog Number
Unit Size
Each
Description
1816 Trace DO Fluidics Panel Only
Price (USD)
Full specifications
Description1816 Trace DO Fluidics Panel Only
TypeDissolved Oxygen Analyzer
Unit SizeEach
Showing 3 of 3
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
1816D0Full specifications
Each1816 Trace DO MonitorRequest A Quote
Description1816 Trace DO Monitor
Frequency50/60 Hz
Outputs4 to 20mA or 0 to 20mA, 0 to 5V or 1 to 5VDC, Bi-directional RS232
Voltage115/230 VAC
Temperature (Metric) Operating2°C to 45°C
TypeDissolved Oxygen Analyzer
Accuracy0.1ppb ±2%, whichever is greater
Response Time1 min.
Width (English)10.24 in.
Width (Metric)26 cm
Weight (English)10.8 lb.
Weight (Metric)4.9 kg
CalibrationAutomatic in water saturated air
Regulatory DetailsNEMA 4X/IP65
Relay Details2
Calibration Range0-10ppm oxygen in water saturated air
Measurement Ranges0.1 to 300ppb (dissolved oxygen)
Sample Flow Rate50 to 200mL/min.
Sample Pressure<4 bar (60psi)
Wattage50w
Electrical Requirements115/230VAC 50/60Hz
Unit SizeEach
1816D2Full specifications
Each1816 Trace DO Monitor Without SensorRequest A Quote
Accuracy0.1ppb ±2%, whichever is greater
CalibrationAutomatic in water saturated air
Calibration Range0-10ppm oxygen in water saturated air
Description1816 Trace DO Monitor Without Sensor
Temperature (Metric) Operating2°C to 45°C
TypeDissolved Oxygen Analyzer
Measurement Ranges0.1 to 300ppb (dissolved oxygen)
Outputs4 to 20mA or 0 to 20mA, 0 to 5V or 1 to 5VDC, Bi-directional RS232
Regulatory DetailsNEMA 4X/IP65
Relay Details2
Response Time1 min.
Sample Flow Rate50 to 200
Sample Pressure<4 bar (60psi)
Width (English)10.24 in.
Width (Metric)26 cm
Weight (English)10.8 lb.
Weight (Metric)4.9 kg
Electrical Requirements115/230VAC 50/60Hz
Voltage115/230 VAC
Wattage50w
Frequency50/60 Hz
Unit SizeEach
1816FPFull specifications
Each1816 Trace DO Fluidics Panel OnlyRequest A Quote
Description1816 Trace DO Fluidics Panel Only
TypeDissolved Oxygen Analyzer
Unit SizeEach
Showing 3 of 3
  • PTFE membrane caps for sensor refurbishment in minutes
  • Rugged and sensitive galvanic dissolved oxygen sensor with rapid response
  • Offers high performance results
  • Galvanic dissolved oxygen sensor with unique Guard Ring™ technology; capable of consuming oxygen and associated gases

Figures