Thermo Scientific™

Dionex™ ERS™ 500e Electrolytically Regenerated Suppressor

Catalog number: 302661CMD
Thermo Scientific™

Dionex™ ERS™ 500e Electrolytically Regenerated Suppressor

Catalog number: 302661CMD

With high-capacity, low noise, high backpressure resiliency, and fast startup, this new generation suppressor was designed for new demands in IC. The Thermo Scientific™ Dionex™ ERS™ 500e Electrolytically Regenerated Suppressor for external water mode applications minimizes peak dispersion and improves peak efficiency, particularly when coupled with 4µm columns. This suppressors was developed in concert with the high efficiency 4µm ion-exchange columns, which use higher flow rates to achieve faster separations while retaining optimal resolution, or equivalent flow rates to achieve higher resolutions while retaining sample throughput.

 
Catalog Number
302661CMD
Unit Size
Each
Description
Dionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Price (USD)
Price: 1,300.00
Your Price:
Availability
-
Full specifications
Quantity
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeAnion Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in)
Flow RateMaximum Eluent Flow Rate: 3 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsRecommended Backpressure: 30 to 150 psi
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage500 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 50 µL
DescriptionDionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Dionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Price (USD)
Price: 1,300.00
Your Price:
Availability
-
Full specifications
Quantity
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeCation Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in.)
Flow RateMaximum Eluent Flow Rate: 0.75 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsExternal Water Mode Up to 40%
Methanol, Ethanol, Acetonitrile, Isopropanol
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage110 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 15 µL
DescriptionDionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Dionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Price (USD)
Price: 1,300.00
Your Price:
Availability
-
Full specifications
Quantity
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeCation Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in)
Flow RateMaximum Eluent Flow Rate: 3 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsExternal Water Mode Up to 40%
Methanol, Ethanol, Acetonitrile, Isopropanol
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage300 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 50 µL
DescriptionDionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Unit SizeEach
Catalog Number
Unit Size
Each
Description
Dionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Price (USD)
Price: 1,300.00
Your Price:
Availability
-
Full specifications
Quantity
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeAnion Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in)
Flow RateMaximum Eluent Flow Rate: 0.75 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsExternal Water Mode Up to 40%
Methanol, Ethanol, Acetonitrile, Isopropanol
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage150 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 15 µL
DescriptionDionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)AvailabilityQuantity
302661CMDFull specifications
EachDionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Price: 1,300.00
Your Price:
-
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeAnion Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in)
Flow RateMaximum Eluent Flow Rate: 3 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsRecommended Backpressure: 30 to 150 psi
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage500 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 50 µL
DescriptionDionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Unit SizeEach
302664CMDFull specifications
EachDionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Price: 1,300.00
Your Price:
-
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeCation Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in.)
Flow RateMaximum Eluent Flow Rate: 0.75 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsExternal Water Mode Up to 40%
Methanol, Ethanol, Acetonitrile, Isopropanol
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage110 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 15 µL
DescriptionDionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Unit SizeEach
302663CMDFull specifications
EachDionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Price: 1,300.00
Your Price:
-
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeCation Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in)
Flow RateMaximum Eluent Flow Rate: 3 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsExternal Water Mode Up to 40%
Methanol, Ethanol, Acetonitrile, Isopropanol
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage300 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 50 µL
DescriptionDionex CERS 500e Cation Electrolytically Regenerated Suppressor for External Water Mode (4 mm), consumables monitoring disabled
Unit SizeEach
302662CMDFull specifications
EachDionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Price: 1,300.00
Your Price:
-
For Use WithModes of Operation Supported: External Water Mode for Eluents Containing up to 40% Solvent; Chemical Regeneration Mode for Eluents Containing up to 100% Solvent; Recycled Eluent Mode for Aqueous Eluents Without Solvent; MPIC (Mobile Phase Ion Chromatography) Mode for Ion-Pairing Eluents
TypeAnion Electrolytically Regenerated Suppressor
Diameter4.8 cm (1.9 in)
Flow RateMaximum Eluent Flow Rate: 0.75 mL/min
PressureRecommended Backpressure: 30 to 150 psi
SolventsExternal Water Mode Up to 40%
Methanol, Ethanol, Acetonitrile, Isopropanol
OperationDesigned with high capacity, low noise, high backpressure resiliency, and fast startup.
Weight (English)0.65 lb.
Weight (Metric)295 g
Width (Metric)4.5 cm
Amperage150 mA
Temperature RangeOperational Temperature Range: 15°C to 40°C
When installed outside the heated column enclosure, suppressors can support applications up to 60°C
Shipping Temperature Range: 0°C to 70°C
Short-term only; do not store or operate suppressors above 40°C for extended lengths of time.
Void VolumeLess than 15 µL
DescriptionDionex AERS 500e Anion Electrolytically Regenerated Suppressor for External Water Mode (2 mm), consumables monitoring disabled
Unit SizeEach
Showing 4 of 4

This high-capacity suppressor serves virtually all analytical scale IC applications, for both anions and cations, and is available in 2mm and 4mm formats. The Dionex ERS 500e Suppressor accommodates isocratic or gradient use with carbonate (isocratic only) hydroxide, methanesulfonic acid, or sulfuric acid eluents in both the standard bore (4 mm) and microbore (2 mm) format.

Next-Generation Suppressor—Built for New Demands in IC Applications
  • Improved compatibility with hyphenated detection techniques, particularly mass spectrometry, because of its higher backpressure tolerance (leak free up to 900 psi, operates up to 200 psi)
  • Higher temperature tolerance (up to 80°C in transit and storage, 40°C for operation)
  • Full electrolytic regeneration without reagents allowing easier recoveries after operation without current due to its planar packed-bed suppression chamber
  • Low peak dispersion preserves peak shape efficiency of 4µm columns
  • High suppression capacity produces stable peak area values immediately after restart without the need for chemical regeneration
  • Low noise makes the suppressor suitable for trace analysis
Built for External Water Mode Applications
  • Reduced regenerant chamber backpressure for easy implementation of pressurized reservoir delivery.
  • Parallel regenerant flow to maximize regenerant sweep out for borate eluents and eluents containing solvents (up to 40%).
  • Can be used in the Chemical Regenerant Mode.
Improves Sensitivity for More Reliable Quantitation

When used with the Thermo Scientific™ Dionex™ CRD 300 Carbonate Removal Device, the Dionex ERS 500e Suppressor reduces background conductivity and noise, enhances analyte response, and improves sensitivity for more reliable quantitation with carbonate eluents.

Fundamental to Enabling Reagent-Free™ IC (RFIC™) Operation
  • Full regeneration without reagents

The Dionex ERS 500e suppressor is a direct replacements for the Thermo Scientific™ Dionex™ SRS™ 300 Self-Regenerating Suppressor.

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for six (6) months thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.

Figures

Documents & Downloads

Certificates

    Frequently asked questions (FAQs)

    Citations & References

    Search citations by name, author, journal title or abstract text