Achieve high resolution separations with Thermo Scientific™ Dionex™ CarboPac™ PA20 1 mm columns. The CarboPac PA20 1 mm column is a specialized anion-exchange column designed to be used with high performance anion exchange chromatography with pulsed amperometric detection (HPAE-PAD) for high resolution separations of simple sugars. The Dionex CarboPac PA20 1 mm column is recommended for Dual Eluent Generation Cartridge (Dual EGC) mode applications using a Thermo Scientific™ Dionex™ ICS-6000 HPIC™ System.

 
Catalog Number
303370
Unit Size
Each
Column Type
Guard Column
Length (Metric)
30 mm
Price (USD)
Full specifications
Anion Exchange Capacity1.4 µeq per column
Column ConstructionPEEK
Column TypeGuard Column
DescriptionDionex CarboPac PA20 1 mm Guard column (1 x 30 mm)
Flow RateRecommended flow rate: 1mm: 0.056mL/min
For Use With (Equipment)Dionex CarboPac PA20, 1 x 150 mm (Analytical Column ) and CarboPac PA20, 1 x 30 mm (Guard Column)
Max. Pressure5000 psi at 0.056 mL/min
Solvent CompatibilitypH 0–14, 100% compatible with common HPLC solvents. Potassium hydroxide, potassium methanesulfonate via electrolytic eluent generation.
Resin Composition6 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 240 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked)
Temperature (Metric)Recommended operating temp: 30°C
Temperature (Metric) Max4-60 °C
Length (Metric)30 mm
Diameter (Metric)1 mm
Unit SizeEach
Catalog Number
Unit Size
Each
Column Type
Separator Column
Length (Metric)
150 mm
Price (USD)
Full specifications
Anion Exchange Capacity7.2 µeq per column
Column ConstructionPEEK
Column TypeSeparator Column
DescriptionDionex CarboPac PA20 1 mm Analytical column (1 x 150 mm)
Flow RateRecommended flow rate: 1mm: 0.056mL/min
For Use With (Equipment)Dual EGC
Max. Pressure5000 psi at 0.056mL/min
Solvent CompatibilitypH 0–14, 100% compatible with common HPLC solvents. Potassium hydroxide, potassium methanesulfonate via electrolytic eluent generation
Stationary PhasePA20
Resin Composition5.5 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 240 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked)
Temperature (Metric)Recommended operating temp: 30°C
Temperature (Metric) Max4-60 °C
Length (Metric)150 mm
Diameter (Metric)1 mm
Unit SizeEach
Showing 2 of 2
Catalog NumberSpecificationsUnit SizeColumn TypeLength (Metric)Price (USD)
303370Full specifications
EachGuard Column30 mmContact Us ›
Anion Exchange Capacity1.4 µeq per column
Column ConstructionPEEK
Column TypeGuard Column
DescriptionDionex CarboPac PA20 1 mm Guard column (1 x 30 mm)
Flow RateRecommended flow rate: 1mm: 0.056mL/min
For Use With (Equipment)Dionex CarboPac PA20, 1 x 150 mm (Analytical Column ) and CarboPac PA20, 1 x 30 mm (Guard Column)
Max. Pressure5000 psi at 0.056 mL/min
Solvent CompatibilitypH 0–14, 100% compatible with common HPLC solvents. Potassium hydroxide, potassium methanesulfonate via electrolytic eluent generation.
Resin Composition6 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 240 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked)
Temperature (Metric)Recommended operating temp: 30°C
Temperature (Metric) Max4-60 °C
Length (Metric)30 mm
Diameter (Metric)1 mm
Unit SizeEach
303369Full specifications
EachSeparator Column150 mmContact Us ›
Anion Exchange Capacity7.2 µeq per column
Column ConstructionPEEK
Column TypeSeparator Column
DescriptionDionex CarboPac PA20 1 mm Analytical column (1 x 150 mm)
Flow RateRecommended flow rate: 1mm: 0.056mL/min
For Use With (Equipment)Dual EGC
Max. Pressure5000 psi at 0.056mL/min
Solvent CompatibilitypH 0–14, 100% compatible with common HPLC solvents. Potassium hydroxide, potassium methanesulfonate via electrolytic eluent generation
Stationary PhasePA20
Resin Composition5.5 µm Diameter Substrate (Ethylvinylbenzene 55% Crosslinked with Divinylbenzene) Agglomerated with 240 nm MicroBead Difunctional Quaternary Ammonium Ion (5% Crosslinked)
Temperature (Metric)Recommended operating temp: 30°C
Temperature (Metric) Max4-60 °C
Length (Metric)150 mm
Diameter (Metric)1 mm
Unit SizeEach
Showing 2 of 2

Combined with pulsed amperometric detection (PAD), this anion-exchange column provides efficient, high reslolution separations with no need for derivatization. The Dionex CarboPac PA20 1 mm column is designed high resolution separations of simple sugars

  • Predictable, high-resolution, separation of monosaccharides, disaccharides and some oligosaccharides using electrolytically generated potassium methanesulfonate and potassium hydroxide
  • Rugged all-purpose column to determine monosaccharides and disaccharides in a variety of samples
  • Column chemistry has USP designation L69 and is used in the USP’s Heparin Sodium monograph and General Chapter <210> Monosaccharide Analysis