RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector

Catalog number: 4250812

RadEye™ SPRD-GN Spectroscopic Personal Radiation Detector

Catalog number: 4250812
Get RIID capability in the palm of your hand. The Thermo Scientific™ RadEye™ SPRD-GN Personal Radiation Detector is the first pager-sized PRD that significantly exceeds the original ANSI N42-48 2008 standards for neutron alarms. With outstanding neutron performance and reliable gamma IDs, the RadEye SPRD-GN Personal Radiation Detector may be the only radiation detection tool you will need.
 
Catalog Number
4250812
Unit Size
Each
Description
RadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra download
Price (USD)
Full specifications
Battery Life∽120 hr.
Battery TypeAAA x 2
DescriptionRadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra download
Radiation TypeGamma Neutron
Sensitivity(cps per µSv/h (662 keV)) 110
Thermal neutron sensitivity (cps/nv) 4
Weight (English)0.385 lb. (including batteries and rubber sleeve)
Weight (Metric)0.175 kg (including batteries and rubber sleeve)
Measurement RangesDose Rate Range: 1 μR/h to 25 mR/h (10 nSv/h to 250 μSv/h)
BackgroundNBR (Natural Background Rejection): Advanced with 6 Energy Windows
Certifications/ComplianceIP65
Energy Range(+/- 30%) 60keV - 3 MeV
Response TimeTypical ID-time @ 1µSv/h (100µR/h) ∼5 min
Alarm NotificationDisplay, LED, Sounder, Vibe
CommunicationsWireless communications BT4 optional
Wired communications USB to IR
Neutron Pager AlarmNeutron Alarm Response: ANSI N42.48-2008: Yes (< 2 s)
Neutron verification: thermal neutrons & fast neutrons
Drop Distance to Concrete1.5m
Detector TypeCLYC (Cs2LiYCl6)
Unit SizeEach
Showing 1 of 1
Catalog NumberSpecificationsUnit SizeDescriptionPrice (USD)
4250812Full specifications
EachRadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra downloadRequest A Quote
Battery Life∽120 hr.
Battery TypeAAA x 2
DescriptionRadEye SPRD-GN Personal Radiation Detector, includes software for configuring RadEye and Spectra download
Radiation TypeGamma Neutron
Sensitivity(cps per µSv/h (662 keV)) 110
Thermal neutron sensitivity (cps/nv) 4
Weight (English)0.385 lb. (including batteries and rubber sleeve)
Weight (Metric)0.175 kg (including batteries and rubber sleeve)
Measurement RangesDose Rate Range: 1 μR/h to 25 mR/h (10 nSv/h to 250 μSv/h)
BackgroundNBR (Natural Background Rejection): Advanced with 6 Energy Windows
Certifications/ComplianceIP65
Energy Range(+/- 30%) 60keV - 3 MeV
Response TimeTypical ID-time @ 1µSv/h (100µR/h) ∼5 min
Alarm NotificationDisplay, LED, Sounder, Vibe
CommunicationsWireless communications BT4 optional
Wired communications USB to IR
Neutron Pager AlarmNeutron Alarm Response: ANSI N42.48-2008: Yes (< 2 s)
Neutron verification: thermal neutrons & fast neutrons
Drop Distance to Concrete1.5m
Detector TypeCLYC (Cs2LiYCl6)
Unit SizeEach
Showing 1 of 1
  • Unprecedented size for gamma detection, gamma ID, and neutron detection
  • Single detector enables less complex design, superior field reliability, and reduced size & weight
  • Neutron alarms in <2 seconds and low false alarms exceeding ANSI specifications as well as lithium and He-3 based units
  • Patent pending source-less routines for ID stabilization and outstanding neutron sensitivity
  • Advanced NBR identifies artificial radiation while minimizing false alarms

Figures