Flow Rate | 0.7 L/min. (standard) |
Inputs | 4 Isolated Voltage Inputs 0 to 10 V, 6 Isolated Analog Voltages Outputs, with 4 Selectable Ranges, 6 Isolated Analog Current Outputs, with 2 Selectable Ranges, 16 Digital Inputs (TTL), 8 Solenoid Driver Outputs, 10 Digital Reed Relay Contact Outputs |
Linearity | ±1% full scale |
Response Time | 80 sec. (10 sec. average time), 110 sec. (60 sec. average time), 320 sec. (300 sec. average time) |
Span Drift | ±1% full scale (24 hr.) |
Temperature (English) Operating | 32°F to 113°F |
Temperature (Metric) Operating | 0°C to 45°C |
Zero Noise | 1 ppm RMS (10 sec. averaging time), 0.5 ppm RMS (60 sec. averaging time), 0.25 ppm RMS (300 sec. averaging time) |
Certifications/Compliance | CE, TUV-SUD Safety |
Communication Ports | 1 RS-232/485 port 1 RS-485 external accessory port 3 Full speed USB ports (one in front, two in rear) 1 Gigabit ethernet port |
Communication Protocols | MODBUS, streaming |
Depth (English) | 24 in. |
Depth (Metric) | 609 mm |
Description | 43iQ High Level Sulfur Dioxide Analyzer |
Detection Limit | 2 ppm (10 second averaging time) 1ppm (60 second averaging time) 0.5 ppm (300 second averaging time) |
Electrical Requirements | 100-240 VAC 50/60 Hz 275W |
Height (English) | 8.72 in. |
Height (Metric) | 221.48 mm |
Interferences | (EPA levels) Less than lower detectable limit except for the following: NO: < 3 ppb, tested at 500 ppb, M-Xylene: tested at 200 ppb, H2O: tested at 2% of reading |
Measurement Range | 0-1000 ppm; 0-3000 mg/m3 Extended Range: 0-10000 ppm; 0-30000 mg/m3 |
Weight (English) | 37.1 lb. |
Weight (Metric) | 16.8 kg |
Width (English) | 16.75 in. |
Width (Metric) | 425.45 mm |
Zero Drift | (24 hour) <1 ppm |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
43IQHL | Each | 43iQ High Level Sulfur Dioxide Analyzer | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Discover the non-stop intelligence of the iQ Series Gas Analyzer now with a two-year warranty. Our next generation platform of gas analyzers includes:
Predictive Diagnostics
Address problems before they occur with improved serviceability and plug and play components. 24/7 access to your analyzer’s information helps minimize troubleshooting time with innovative, interchangeable DMC modules in a highly precise, yet tough solution.
Proactive Communications
Maintain optimum performance through iQ360 and email alerts. When subscribed to iQ360 service, your instrument communicates directly to our technical support team upon alarm activation. Our technical support team develops a corrective plan and emails it to your staff. Eliminate surprises and take control of your day with the iQ Series Gas Analyzers.
Personal Device Connectivity
Real time, continuous remote monitoring is now possible with the iQ companion mobile device app. The iQ app allows for remote monitoring of iQ gas analyzers, simplified ways of getting in touch with us, and instant access to both maintenance alerts and product documentation.