Módulos transparentes separables para inmunoanálisis
Módulos transparentes separables para inmunoanálisis
Módulos transparentes separables para inmunoanálisis
Módulos transparentes separables para inmunoanálisis
Módulos transparentes separables para inmunoanálisis
Thermo Scientific™

Módulos transparentes separables para inmunoanálisis

Elija entre cuatro superficies y una gran variedad de pocillos y configuraciones con estos módulos separables para inmunoensayos, que ofrecen una elección óptima de productos para el ensayo específico.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoTratamiento de superficieForma del pocilloN.° por paqueteTipo de producto
446469MaxiSorpRedondo10Placa de tiras
446442PolySorpRedondo5Placa de tiras
446477PolySorpRedondo10Marco
446490MultiSorpRedondo10Marco
446639MaxiSorpRedondo10Tira de microplacas
473539PolySorpRedondo5Tira de microplacas
473768MaxiSorpRedondo5Placa de tiras
95029390Adhesión universal (UB)Redondo50Tira de microplacas
Número de catálogo 446469
Precio (MXN)
-
Tratamiento de superficie:
MaxiSorp
Forma del pocillo:
Redondo
N.° por paquete:
10
Tipo de producto:
Placa de tiras

Elija entre cuatro superficies y una gran variedad de pocillos y configuraciones con los módulos separables para inmunoensayos Thermo Scientific™, que ofrecen fiabilidad, reproducibilidad entre pocillos y la mejor selección de productos para cada ensayo en concreto.

Elija entre módulos LockWell, BreakApart y separables de 1x8 en marco estándar de 96 pocillos.
  • Para ensayos de inmunoanálisis de fase sólida, por ejemplo,
  • Módulos independientes ELISA que son fáciles de manipular
  • Sistema alfanumérico para una orientación sencilla
  • Se adaptan a equipo estándar
  • Alta calidad óptica para unos resultados fiables
  • Poliestireno

Opciones de superficie:

  • Thermo Scientific™ PolySorp™, Immulon™ 1By Universal Binding (UB)  para la adsorción de moléculas hidrófobas.
  • Thermo Scientific™ Medisorp™ e Immulon 2HB son ligeramente hidrófilas y unen una amplia variedad de biomoléculas.
  • Thermo Scientific™ MaxiSorp™, Immulon 4 HBX y Enhanced Binding (EB) son hidrófilas y resultan idóneas para los ensayos de sándwich de anticuerpos.
  • Thermo Scientific™ MultiSorp™ son muy hidrófilas y funcionan muy bien con proteínas solubles en agua y glicanos.
Garantía: 90 días
Exención de responsabilidad de la restricción de uso para investigación interna: Cualquier restricción impuesta al comprador para utilizar el producto o productos únicamente para fines de investigación interna no se aplica al producto o productos que aparecen en las páginas web asociadas a esta declaración.
Especificaciones
Propiedad de uniónHidrófilo
BreakApartTiras separable
Los recipientesSí
DescripciónAlta calidad óptica para unos resultados fiables
Método de detecciónColorimétrico
Para utilizar con (aplicación)Para ensayos de tipo sandwich de anticuerpos
TapaSin tapa
N.º por caja60
N.° por paquete10
Envase10 paq.
Bloqueo de placasNinguno
Tipo de productoPlaca de tiras
Cantidad60/caja
Molécula dianaAnticuerpos (glucoproteínas)
Volumen de trabajo (métrico)250 μl
Diseño del pocilloC8
matriz, red, conjunto8 x 12
ColorTransparente
FormatoPlaca de tiras
MaterialPoliestireno
N.° de pocillos96
EsterilidadNo estéril
Tratamiento de superficieMaxiSorp
Volumen del pocillo (métrico)350 μl
Forma del pocilloRedondo
Unit SizeCase of 60

Preguntas frecuentes

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with LockWell modules?

Due to the locking feature design of the LockWell modules, the 8-Well Strip Caps for Immuno Standard Modules are not compatible with, and will not seal, the LockWell Modules.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.