Analog Outputs | Up to 2 Channels (Optional) |
Automated Start-Up Functions | Wavelength Verification |
Conductivity Wetted Parts | PEEK, Quartz Glass, Stainless Steel |
Description | VWD-3400 RS Rapid Separation Variable Wavelength Detector, four channels, without flow cell |
Data Collection Rate | 200 Hz |
Detection Mode | UV-vis Detection (4 Channels) |
Detector Type | Variable Wavelength |
Type | Variable Wavelength Detector |
Display | Front Panel |
Drift | <1 x 10?4 AU/hr |
Filter | Fast Switching Second-Order |
Flow Rate | Nano to Semi-Prep |
Lamp | Deuterium Lamp, Tungsten Lamp |
Linearity | <5%RSD |
Noise | <±3.5 µAU |
Optical Bandwidth | 6 nm |
pH Wetted Parts | PEEK, Quartz Glass, Stainless Steel |
Safety Features | Power-up Diagnostics of Optics, Cooling Fans, Motors, and Electronics Leak Sensor |
Temperature Control | Yes |
Wavelength Accuracy | ±1.0 nm |
Wavelength Range | 190 to 900 nm |
Voltage | 85 to 260 V |
Unit Size | Each |
Analog Outputs | Up to 2 Channels (Optional) |
Automated Start-Up Functions | Wavelength Verification |
Conductivity Wetted Parts | PEEK, Quartz Glass, Stainless Steel |
Description | VWD-3100 Variable Wavelength Detector, one channel, without flow cell |
Data Collection Rate | 100 Hz |
Detection Mode | UV-vis Detection (Single Channel) |
Detector Type | Variable Wavelength |
Type | Variable Wavelength Detector |
Display | Front Panel |
Drift | <1 x 10-44 AU/hr |
Filter | Fast Switching Second-Order |
Lamp | Deuterium Lamp, Tungsten Lamp |
Linearity | <5%RSD |
Noise | <±3.5 µAU |
Optical Bandwidth | 6 nm |
pH Wetted Parts | PEEK, Quartz Glass, Stainless Steel |
Safety Features | Power-up Diagnostics of Optics, Cooling Fans, Motors, and Electronics Leak Sensor |
Temperature Control | Yes |
Wavelength Accuracy | ±1.0 nm |
Wavelength Range | 190 to 900 nm |
Voltage | 85 to 260 V |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Detection Mode | Data Collection Rate | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5074.0010 | Each | VWD-3400 RS Rapid Separation Variable Wavelength Detector, four channels, without flow cell | UV-vis Detection (4 Channels) | 200 Hz | Request A Quote | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5074.0005 | Each | VWD-3100 Variable Wavelength Detector, one channel, without flow cell | UV-vis Detection (Single Channel) | 100 Hz | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The increased sensitivity of variable wavelength detectors make them an excellent choice for applications involving trace analytes. Their wide dynamic range also makes them especially suited for pharmaceutical applications involving multiple compounds at very different concentrations.
The four-channel UltiMate 3000 RS Variable Wavelength Detector VWD-3400RS is ideal for research and more complex methods involving analytes with different absorption maxima. For conventional LC applications, this detector allows data acquisition from up to four UV-vis channels at up to 5Hz (up to 200Hz in single-channel mode).
The UltiMate 3000 Single Channel Variable Wavelength Detector VWD-3100 is ideal for routine methods such as quality control applications employing isocratic separations.
Features
Monitor Gradients On Line
The Thermo Scientific™ Dionex™ UltiMate™ 3000 PCM-3000 pH and Conductivity Monitor is an upgrade for accurate pH and conductivity on-line monitoring with the VWD-3000 Series. This unit is typically used to monitor the gradient formation in salt- or pH-gradient-based ion-exchange chromatography (IEC) in biopharmaceutical analysis.
The PCM-3000 supports all modes of chromatography and provides verification of the elution conditions, the retention behavior of the sample, and the precision and repeatability of the instrumentation.