Thermo Scientific™

UltiMate™ 3000 Fluorescence Detectors

Catalog number: 5078.0025
Thermo Scientific™

UltiMate™ 3000 Fluorescence Detectors

Catalog number: 5078.0025
Develop highly selective methods for trace analytes or novel molecules with sensitivity three to six orders of magnitude greater than UV detection. The Thermo Scientific™ Dionex™ UltiMate™ 3000 Fluorescence Detectors offer four channel acquisition at up to 200Hz so you can optimize quantification on the most sensitive channel and single-channel detection at up to 100Hz. 2D or 3D synchro, excitation, emission scans, zero order mode, or multichannel acquisition offer flexibility for method development or routine sample characterization. A variable emission filter allows real-time, compound-related sensitivity optimization.
 
Catalog Number
5078.0025
Unit Size
Each
Description
FLD-3400 RS Rapid Separation Fluorescence Detector with Dual-PMT, four channels, without flow cell
Detection Mode
4 Channels
Price (USD)
Full specifications
DescriptionFLD-3400 RS Rapid Separation Fluorescence Detector with Dual-PMT, four channels, without flow cell
Data Collection Rate200 Hz
Detection Mode4 Channels
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterVariable
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
Flow RateAnalytical to Semi-Prep
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels4
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 880 nm
Wavelength Repeatability±0.2 nm
Wavelength Switching Time<250 ms
Weight (Metric)18 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
FLD-3400 RS Rapid Separation Fluorescence Detector, four channels, without flow cell
Detection Mode
4 Channels
Price (USD)
Full specifications
DescriptionFLD-3400 RS Rapid Separation Fluorescence Detector, four channels, without flow cell
Data Collection Rate200 Hz
Detection Mode4 Channels
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterVariable
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
Flow RateAnalytical to Semi-Prep
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels4
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 630 nm
Weight (Metric)18 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
FLD-3100 Fluorescence Detector with Dual-PMT, one channel, without flow cell
Detection Mode
Single Channel
Price (USD)
Full specifications
DescriptionFLD-3100 Fluorescence Detector with Dual-PMT, one channel, without flow cell
Data Collection Rate100 Hz
Detection ModeSingle Channel
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterFixed
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels1
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 880 nm
Weight (Metric)18 kg
Unit SizeEach
Catalog Number
Unit Size
Each
Description
FLD-3100 Fluorescence Detector, one channel, without flow cell
Detection Mode
Single Channel
Price (USD)
Full specifications
DescriptionFLD-3100 Fluorescence Detector, one channel, without flow cell
Data Collection Rate100 Hz
Detection ModeSingle Channel
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterFixed
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels1
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 630 nm
Weight (Metric)18 kg
Unit SizeEach
Showing 4 of 4
Catalog NumberSpecificationsUnit SizeDescriptionDetection ModePrice (USD)
5078.0025Full specifications
EachFLD-3400 RS Rapid Separation Fluorescence Detector with Dual-PMT, four channels, without flow cell4 ChannelsRequest A Quote
DescriptionFLD-3400 RS Rapid Separation Fluorescence Detector with Dual-PMT, four channels, without flow cell
Data Collection Rate200 Hz
Detection Mode4 Channels
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterVariable
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
Flow RateAnalytical to Semi-Prep
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels4
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 880 nm
Wavelength Repeatability±0.2 nm
Wavelength Switching Time<250 ms
Weight (Metric)18 kg
Unit SizeEach
5078.0020Full specifications
EachFLD-3400 RS Rapid Separation Fluorescence Detector, four channels, without flow cell4 ChannelsRequest A Quote
DescriptionFLD-3400 RS Rapid Separation Fluorescence Detector, four channels, without flow cell
Data Collection Rate200 Hz
Detection Mode4 Channels
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterVariable
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
Flow RateAnalytical to Semi-Prep
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels4
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 630 nm
Weight (Metric)18 kg
Unit SizeEach
5078.0015Full specifications
EachFLD-3100 Fluorescence Detector with Dual-PMT, one channel, without flow cellSingle ChannelRequest A Quote
DescriptionFLD-3100 Fluorescence Detector with Dual-PMT, one channel, without flow cell
Data Collection Rate100 Hz
Detection ModeSingle Channel
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterFixed
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels1
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 880 nm
Weight (Metric)18 kg
Unit SizeEach
5078.0010Full specifications
EachFLD-3100 Fluorescence Detector, one channel, without flow cellSingle ChannelRequest A Quote
DescriptionFLD-3100 Fluorescence Detector, one channel, without flow cell
Data Collection Rate100 Hz
Detection ModeSingle Channel
Detector TypeHigh-Sensitivity Fluorescence
TypeFluorescence Detector
DisplayLCD Monitor
FilterFixed
Flow Cell Max. Pressure290 psi
Flow Cell Thermostatting15°C Above Ambient -50°C
Flow Cell Volume8 μL
GLP FeaturesAutomatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips.
LampXenon Flash Lamp
Lamp Pulse Frequency300 Hz
No. of Channels1
PC ConnectionUSB
Sensitivity>550 ASTM
Spectral Bandwidth20 nm
Temperature ControlYes
Wavelength Accuracy±2 nm
Wavelength Range200 to 630 nm
Weight (Metric)18 kg
Unit SizeEach
Showing 4 of 4
Recommended Use

The Thermo Scientific™ UltiMate 3000 Rapid Separation Fluorescence Detector FLD-3400 is recommended for method development labs that need flexibility in detecting novel compounds that don’t absorb in the UV-vis region of the spectrum. It is ideal for the analysis of carbohydrates, glycans, and polyaromatic hydrocarbons (PAHs) in combination with any Thermo Scientific™ Dionex™ UltiMate 3000 system. The ability to cleave and derivitize glycans from intact proteins or monoclonal antibodies eliminates interferences from coeluting matrix peptides.

Sensitive Fluorescence Performance

  • Data rates at up to 200Hz detect the narrowest peaks in UHPLC separations.
  • Maximum stray light suppression provides excellent sensitivity.
  • Low limits of detection are possible with a Raman S/N: >550 ASTM (>2100 using dark signal as noise reference).
  • Active flow cell temperature control ensures stable fluorophore activity independent of ambient temperature.
  • Long-life xenon flash lamp delivers the highest sensitivity and long-term operation.
  • Optional second photomultiplier (PMT) for Dual-PMT operation extends the wavelength range up to 900nm without sacrificing sensitivity in the standard wavelength range.

Easy-to-Use Fluorescence Detector

  • Large front panel display allows easy monitoring of detector status.
  • Flow cell syringe injection kit enables cost-effective off-line measurements.
  • Flow cell optimized for trace analysis with narrow-bore UHPLC and conventional HPLC columns.
  • Automate qualification monitoring and tracking of flow cells for regulatory compliance.
  • Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System software offers performance optimization and instrument wellness monitoring for ease of use and maximum uptime.

Figures