Cell Volume | 13 μL |
Description | MWD-3000 RS Rapid Separation Multiple Wavelength Detector, without flow cell |
Data Collection Rate | 200 Hz |
Detection Mode | UV-vis Detection (8 Channels) |
Detector Type | Single-Beam |
Type | Multiple Wavelength Detector |
Display | LCD Monitor |
Drift | <1 mAU/hr |
Flow Cell Volume | 13 μL |
GLP Features | Automatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips. |
Lamp | Deuterium Lamp, Tungsten Lamp |
Linearity | <3%RSD |
Noise | <±8 µAU |
PC Connection | USB |
Pixel Resolution | <1.0 nm |
Response | 2 Sec. |
Slit Width | Variable |
Wavelength Accuracy | ±1.0 nm |
Wavelength Range | 190 to 800 nm |
Voltage | 85 to 260 V |
Unit Size | Each |
Cell Volume | 13 μL |
Description | MWD-3000 Multiple Wavelength Detector, without flow cell |
Data Collection Rate | 100 Hz |
Detection Mode | UV-vis Detection (8 Channels) |
Detector Type | Single-Beam |
Type | Multiple Wavelength Detector |
Display | LCD Monitor |
Drift | <1 mAU/hr |
Flow Cell Volume | 13 μL |
GLP Features | Automatic Instrument Qualification (AutoQ), System Wellness and Qualification Monitoring with Chromeleon Software, Lamp and Cell ID Chips. |
Lamp | Deuterium Lamp, Tungsten Lamp |
Linearity | <3%RSD |
Noise | <±8 µAU |
PC Connection | USB |
Pixel Resolution | <1.0 nm |
Response | 2 Sec. |
Slit Width | Fixed |
Wavelength Accuracy | ±1.0 nm |
Wavelength Range | 190 to 800 nm |
Voltage | 85 to 260 V |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Detection Mode | Data Collection Rate | Price (USD) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5082.0040 | Each | MWD-3000 RS Rapid Separation Multiple Wavelength Detector, without flow cell | UV-vis Detection (8 Channels) | 200 Hz | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
5082.0030 | Each | MWD-3000 Multiple Wavelength Detector, without flow cell | UV-vis Detection (8 Channels) | 100 Hz | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The UltiMate 3000 Multiple Wavelength Detector is recommended for laboratories employing either conventional or RSLC in routine analyses and method development. A standard version (MWD-3000) with a data rate of up to 100Hz is also available for use with Thermo™ Scientific™ Dionex™ UltiMate™ 3000 Standard LC systems.
Features
Monitor Gradients On Line
The Thermo Scientific™ Dionex™ UltiMate™ 3000 PCM-3000 pH and Conductivity Monitor is an upgrade for accurate pH and conductivity on-line monitoring with the MWD-3000 Series detectors. This unit is typically used to monitor the gradient formation in salt- or pH-gradient-based ion-exchange chromatography (IEC) in biopharmaceutical analysis.
The PCM-3000 pH and Conductivity Monitor supports all modes of chromatography and provides verification of the elution conditions, the retention behavior of the sample, and the precision and repeatability of the instrumentation.